Denial of storm water damage claim relying on wear and tear and defect exclusions
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Claim
Amount
Determination
Case No: 374618 Determination Page 1 of 9
Case number: 374618 12 June 2015
1 Overview
1.1 Dispute
The Applicant claimed for water damage to her property. She first noticed the
damage after a storm which occurred approximately 11 months prior.
The Financial Services Provider (FSP) denied the Applicant‟s claim on the
grounds of wear, tear and gradual deterioration due to a building defect.
The Applicant disputes the FSP‟s denial of her claim.
1.2 Issue and key findings
Can the FSP deny the Applicant’s claim?
The FSP cannot deny the Applicant‟s claim because:
the Applicant can establish on the balance of probabilities the claim is as a
result of an insured event, namely a storm
the FSP has not established on the balance of probabilities the exclusions
relied on apply.
1.3 Determination
This Determination is in favour of the Applicant.
Pursuant to the terms and conditions of the policy, the FSP is to pay the
Applicant‟s costs in repairing the water damage to her property caused by the
storm event.
The Applicant is to bear the costs to rectify the defect (the cost to properly install
the bifold door) and any additional renovation work she may have had completed.
If required by the FSP, the Applicant is to provide all invoices and receipts for the
relevant repairs, detailing the date payment was made.
The FSP is to also pay interest to the Applicant for the accepted repair costs, in
accordance with section 57 of the Insurance Contracts Act 1984 (Cth) (the Act).
Interest is payable from the date the Applicant paid for the accepted repairs, until
the date payment is made.
Case No: 374618 Determination Page 2 of 9
2 Reasons for Determination
2.1 Can the FSP deny the Applicant’s claim?
Applicant can establish the loss has been caused by an insured event
The onus is on the Applicant to establish on the balance of probabilities that the
damage she claims to the property was caused by a storm in July 2013. If this is
established, the onus shifts to the FSP to establish on the balance of probabilities
the damage was caused by gradual deterioration in order to be entitled to deny or
limit the claim
It is acknowledged the Applicant did not immediately report the damage to the
FSP. She indicates she noticed the water in the vicinity immediately after the
storm and had never seen this prior to or since the storm. She describes a storm
of great ferocity with heavy rain and strong winds that drove the rain almost
horizontal with significant force. She says the severity and volume of rain drove
the rain into the door recess with such force and at such an angle that it
overflowed into the inside of the property.
However, she did not become aware of the extent of the damage until she
appointed a builder to undertake renovations at the property sometime later.
The Applicant provided reports from the builder (QO) detailing the cause and
extent of damage. QO said:
the bifold door was manufactured to Australian standards which takes into
account above average rainfall
however the bifold door was not installed in 2003 to Australian standards
which resulted in the bottom sill to become inundated with water during a
storm or heavy rainfall event
usually, water which entered the sill drained away through drainage holes
which were sufficient to drain a small to moderate amount of water
when there was average rainfall the drainage holes would operate
when he was working at the property on days of moderate to heavy rain the
drainage holes worked and no water came into the property
there is no evidence to show damage to the floorboards was three years old
the damage was caused by a single water inundation event, not through
continual water entry as even during periods of high rainfall the drainage holes
worked, save if there was a significant storm event
QO is a builder qualified to comment about the extent and cause of the damage.
Further not only has he inspected the property to provide a quote to repair the
damage, but he undertook the repairs. Further, the FSP accepted his opinion
about the damage to the balcony and has paid to the Applicant $15,500 for storm
damage to the outside of the house.
Having reviewed his reports, I am persuaded on the balance of probabilities that
the Applicant can establish that although the bifold door was not installed to
Australian standards, it did not allow continued water entry into the house. Rather,
it was only when there was a significant storm event that the drainage holes failed
Case No: 374618 Determination Page 3 of 9
and water entered the house. There was a significant storm event in July 2003
and water entered the house. Therefore, I am satisfied the Applicant can establish
a prima facie claim.
FSP has not established exclusions relied on apply
The onus then shifts to the FSP to establish any exclusions upon which it relies to
limit or deny the Applicant‟s claim.
The FSP‟s e xperts indicated the rot to some of the timber indicated the damage
had been occurring for quite some time. They say the cause of the water entry is a
door which was incorrectly installed. One of the FSP‟s experts (PS) indicates the
damage had occurred over several storm/rain events. He said the damage noted
was consistent with damage which had occurred over a three year period or
greater. However he does not say how he arrived at that view nor has he
addressed the opinion of QO who challenges the damage to the floor boards was
three years old.
I also note PS suggests the cracked tile in the balcony area was also damaged
over a long period of time and that this would cause water to pass “through the
waterproof membrane” of the balcony area. But once QO actu ally dismantled the
balcony there was no evidence that gradual leakage had occurred at the point of
the cracked tile and the FSP paid that part of the claim. On this basis, I consider
his opinion about cause of damage is compromised.
In light of QO‟s advi ce of when the defective door was installed (in 2003), I have
considered PS‟s opinion of the period over which he says the damage occurred. I
cannot reconcile why the damage would have only occurred over the preceding
three year period, if the sole cause of the damage was the defect noted.
Additionally, PS has not made any comment on QO‟s advice about the drain
holes‟ capacity. This aspect is not addressed by him or the FSP‟s other experts.
The photographs provided clearly show the relevant drain holes. PS, however,
insists water has nowhere to go, other than inside the home, because of the
defective design of the door.
The FSP questions the validity of QO‟s observations of these drain holes in action.
That is, it does not accept during heavy rain periods, over a period of time, these
drain holes would work as QO has suggested. However, QO has clearly indicated
he made such an observation during moderate to heavy rainfall and the drain
holes functioned and took water away from the house.
I am more persuaded by the evidence provided by QO, given he has observed the
drain holes and how they work during rain. He has clearly explained why these
would normally work and how the building was constructed to relevant Australian
Standards (other than the defective installation of the door). He adds these
Standards reflect normal or usual Australian conditions, including weather
conditions, and therefore should only fail during abnormal conditions. The
Applicant asserts the storm conditions on 1 July 2013 were abnormal.
Based on this, I am satisfied the damage has been caused by a one-off storm
event. The rot in the timbers can be explained by the fact the claim was not
Case No: 374618 Determination Page 4 of 9
reported by the Applicant for some 11 months after the event. However, given the
rot was not visible to the Applicant, this is not unreasonable.
This is further supported by the FSP‟s original assessor (TH) who noted there
were no home maintenance works required and no indication of prior damage.
Accordingly, on the material provided, the FSP has not established on the balance
of probabilities the exclusion relating to wear, tear and/or gradual deterioration
applies.
The policy also excludes damage caused by a defect, which in this instance,
clearly exists. However, this exclusion only applies if the Applicant was not aware,
or could not have been reasonably aware, of the defect. There is no information to
suggest the Applicant was aware of the defective installation of the door.
Therefore, the FSP has also not established on the balance of probabilities the
defect exclusion applies.
Parties to agree cash settlement
The quote from QO dated 26 August 2014 for rectification work includes the cost
of replacing damage floorboards (70 m²). The FSP indicated that flooring in a
room would be limited by the policy ‟s “same room” definitions as set out in the
PDS. In response the Applicant says the entire upstairs area is a single room with
no separating walls and satisfies the “same room” definition as set out in the PDS.
She submits it as a single open plan room with one type of floor covering and no
doors or archways. She also indicates she replaced the entire upstairs section on
the basis of advice received from the FSP‟s flooring specialist.
I acknowledge the FSP‟s policy includes conditions regarding what it will pay when
floor coverings are damaged. I have carefully considered the material provided
including the photographs but they are insufficient for me to address this aspect of
the matter if it remains in dispute.
It remains necessary for the amount of the cash settlement to be agreed, based
on the cost of rectification, the amount already paid by the FSP and the policy
response to the “same room” issue. FOS encourages the parties to res olve any
issues that might arise during that process. However, the parties can return to
FOS if they are unable to resolve issues arising from the amount of the settlement.
Case No: 374618 Determination Page 5 of 9
3 Supporting information
3.1 FOS approach
General information
As advised to the parties, FOS has considered it appropriate to expedite the
dispute in accordance with the Operational Guidelines to the FOS Terms of
Reference. This dispute has not been the subject of a FOS Recommendation and
has proceeded directly to Determination.
A full exchange of the relevant information has taken place between the
respective parties and each party has had the opportunity of addressing any
issues raised.
I have decided this case on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous FOS decisions.
All of the provided material has been read and considered. The parties have
raised numerous issues in their submissions to the Service. For the purpose of
this Determination, commentary is restricted to only those issues considered
relevant to the outcome.
Prima facie claim
There is an onus on an insured to establish on the balance of probabilities that a
claim fits the definition of an insured event. This is known as a prima facie claim.
Should this onus be discharged, it is then the responsibility of the insurer to
establish the application of any exclusion on which it relies to deny the claim.
To be entitled to cover from the FSP, the onus therefore rests with the Applicant to
establish that the loss fits within the scope of what is covered by the FSP‟s policy.
The policy provides cover for a series of defined events as outlined in the PDS. It
does not provide blanket cover for all types of loss.
3.2 Policy wording
“ What you are covered for – Insured Events
We cover you for loss or damage to the building caused by an insured event which
happens during the period of cover. There are some things we do not cover and these
are shown in the „We do not cover‟ section of the following tables on pages 17 to 25
and in the „What we do not cover – general exclusions‟ on pages 32 to 36.
…
Storm
We cover We do not cover
Loss or damage to the building caused
by a storm …
…
Case No: 374618 Determination Page 6 of 9
What we do not cover – general exclusions
You are not covered under any section of your policy for damage, loss, cost or legal
liability that is caused by, arises from or involves:
…
Defect, structural fault or design fault
a defect, structural fault or design fault that you knew about (or should reasonably
have known about) and did not fix before the loss or damage occurred (e.g. if there
are signs that a defect previously caused damage, we will not pay a later claim for
further damage from this defect).
…
Wear, tear and gradual deterioration
wear, tear, rust, fading, rising damp, mould, mildew, corrosion, rot, action of light or
gradual deterioration such as, but not limited to :
tiles and their adhesive or grouting breaking down;
weathering of roof tiles or roof ridge capping;
gradual weathering and breakdown of bricks, mortar or concrete.”
How to establi sh your loss
Establish an incident took place
When making a claim you must be able to prove that an incident covered by your
policy actually took place. If you do not do this, we will not be able to pay your claim.
What we mean by that?
Incident
means a single event, accident or occurrence which you did not intend or expect to
happen.
3.3 Expert evidence
Record Key points
Claim circumstances in
FSP’s claim notes
Noted 3 June 2014
Claimed damage to the timber flooring and skirting boards
in the lounge. Water coming through the bifold doors .
Identified date of loss storm 1 July 2013 8pm .
FSP’s Assessor (TH)
Assessment Report
Undated
Inspected and photographed the property .
The property is approximately 7+ years old.
No home maintenance works are required.
No indication of prior damage .
Bi - fold doors fitted to the balcony (area of damage noticed)
have not been fitted correctly (back to front). The
waterproof seal at the bottom of the doors is on the inside
of the room which allows water to seep in under the doors,
into the floor and wall cavity causing damage to the timber
flooring skirting and architraves.
Water has also seeped down the wall cavity to the
brickwork to the porch below .
There is also efflorescence evident on brickwork below the
balcony.
FSP’s second assessor
(CC)
Assessor Report
Undated
Assessment conducted
on 24 June 2014
Desktop assessment was conducted based on TH‟s report
and photographs only.
It is clear from the photographs damage is due to long term
seepage around the base of the doors.
Damage is not due to any one storm event.
TH noted seals are incorrectly placed due to doors opening
Case No: 374618 Determination Page 7 of 9
inwards – this is not correct as doors like this can open
either way. Both options can be subject to seepage
through the doors.
Damage is typical of a gradual deterioration type due t o
long term seepage.
FSP’s Builder (PS)
Builder‟s Assessment
Report
19 August 2014
PS inspected and photographed property 19 August 2014 .
Ap plicant bought property in 2010.
Timber skirtings and timber floating floor boards in the
upper lounge room were removed by Applicant‟s builder
during renovation works .
About end of May 2014 Applicant noted water damage to
timber flooring inside bifold door sill area .
Also noted water related damages to the downstairs entry
eaves and efflorescence to brick feature wa ll due to water
ingress through the bifold doors .
Heavy rot was sustained to the timber flooring at either
reveal end side of the bi - fold doors. This is consistent with
water exposure over a period of three years or greater.
The bi - fold bottom sill is a de fective design – the outer sill
is higher than the bottom of the timber door. When
rainwater hits the bi - fold door, it tracks down to the bottom
sill reveal. The water cannot escape outside the balcony
area and is diverted into the internal areas of the pr operty.
The damage to the eaves under the balcony and the walls
is due to a pre - existing cracked tile to the balcony area
which was sealed recently (damage occurred over a long
period of time – about three years or greater and would
have been visible to th e Applicant about 2 years ago).
Water would pass through the waterproof membrane, into
the balcony floor cavity causing the water related damages
below, to the eaves.
The damage to the bi - fold door, timber architraves and
timber flooring has not occurred a s a result of a single
storm event. Rather, the damage has been caused by
water ingress over a period of years as evidenced from
long - term breakdown to architraves including rot to timber
flooring. Damage in living room is because of defective
bifold door.
Damage not occurred from a single storm event in July
2013 but due to maintenance or defective issues as
discussed in the report.
Recommended full replacement of the bifold doors and
head flashing installed to door and full replacement of tiled
balcony in cluding waterproof membrane .
Applicant builder’s
Quote QO
26 August 2014
Rectification to balcony including tiles, waterproofing, new
bifold doors, painting, replacing damaged floorboards
$36,850 .
Applicant’s Builder
(QO)
QO inspected the property to provide a quotation for the
repair of the upstairs flooring, bifold doors and balcony
Case No: 374618 Determination Page 8 of 9
Letter
25 September 2014
area following storm damage reported by Applicant .
Property well - maintained .
Design and construction of bifold doors is flawed and not
design ed to sustain severe weather conditions because
sills are in rev erse and no waterproofing trims.
Drain holes and sills are present but the design can only
sustain normal rainfall .
When heavy rainfall, water cannot escape to the outside
balcony area and is diverted back inside .
Significant amount of rain required for there to be sufficient
volume of water to overflow the bottom sill and inundate
the interior .
Inspected the property and found resultant damage to the
bifold door, timber skirting, architraves, flooring and
subflooring in the upper floor and balcony structure.
Damage consistent with water damage sustained during a
water inundation event .
As for the balcony, water had entered the property through
the faulty bifold door, leaked into the subfloor an d the wall
cavity into the balcony resulting in damage to the balcony
floor and underneath as evidenced by efflorescence to
brick feature wall and water stains and breakdown to
timber in entry area and rusting down light in entry area .
QO engaged to repair the damage and removed the
existing tiles on the balcony, inspected the balcony
subfloor underneath the tiles and found no evidence of
water damage or staining that would indicate gradual
leakage had occurred at the point of the cracked tiles .
Applicant’s Builder
(QO)
Letter
7 April 2015
QO completed the quoted building works and wrote the
report as a result of his inspections.
The bi - fold doors were not installed to Australian standards
– this results in the bottom waterproof sill to become
inundated with water during a storm or heavy rainfall event.
Water cannot escape to the outside balcony area and
redirects to inside. However, the door was designed to
drain away water which entered the bottom sill with the
presence of working drainage hol es. These would
sufficiently drain a small to moderate amount of water.
The door was manufactured to Australian standards which
take into account above average rainfall. In times of above
average rainfall, the drainage holes would still do their job.
The d efective door is the original door installed at the time
of building construction. The property was built in 2003.
The fault has been present for 12 years.
There was no evidence of building works or maintenance
issues which would have caused the defect to only
manifest within the last three years.
There is no evidence to suggest the damage to the
floorboards was three years old.
The FSP‟s details of rainfall records for 2010 to 2013 have
been considered. However, these do not relate to the
Case No: 374618 Determination Page 9 of 9
specific location and do not provide information regarding
direct and volume of the rainfall for a single rain event.
Whilst completing building works at the property, there
were days of moderate to heavy rain.
During these times, the drainage holes were observed and
it wa s noted the holes worked with no water entering the
property.
There was no evidence of ongoing failure of the drainage
holes. They were sufficiently designed to handle the above
average rainfalls which may have occurred over the
preceding 12 years since co nstruction.
The issue was not the volume of water which fell during
any monthly period, rather the volume and/or force and
wind direct of a single storm event caused the drainage
holes to fail and the bottom sill to overflow, inundating the
interior of the property.
Damage noted was to the bi - fold door, timber skirting,
architraves, timber flooring and subflooring in the upper
floor and balcony structure.
“In my professional opinion this damage is caused by a
single water inundation event, not a result of r ot caused by
continual water entry because the presence of working
drainage holes that functioned as designed prevented water
entering the property during even periods of high rainfall, with
the exception of a significant storm event – this means there
was no entry point into the house to allow multiple/continued
water entry.”
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.