Home / Financial Firm (Unknown - Insurer) / Determination 373345
Determination 373345
Structural damage claim denied for soil movement exclusion
Summary
The FSP denied the structural damage claim, attributing it to soil movement, while the applicants blamed a burst mains pipe. AFCA found the FSP had not proven the exclusion, ordered the claim accepted with statutory interest, $1,500 non-financial loss and reimbursement of expert costs, and refused loss of rent.
Once the insured shows a prima facie claim for water escaping from a fixed pipe, the insurer must prove on balance that an exclusion such as ground movement applies.
Issues
- Claim denial primary · upheld
“The FSP has not shown, on balance, soil movement caused the damage to the pipe; it has not proven the exclusion it is relying upon.”
- Delay secondary · upheld
“The FSP did not handle the Applicants' claim efficiently. It took 18 months to reach a final decision on the merits of the claim.”
- Other secondary · not upheld
“The Applicants are not entitled to be paid loss of rent because the policy does not provide cover for such loss.”
Subjects and remedies
home or building damagepay claimpay compensationpay interestpay non financial loss
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of
Claim
Determination
Case No: «reference_id» Determination Page 1 of 10
Case number: 373345 2 7 February 2015
1 Overview
1.1 Dispute
The Applicants lodged a claim for structural damage to their property with the
Financial Services Provider (FSP). The FSP denied the claim on the basis the
damage was due to earth movement and other causes excluded from cover. The
Applicants maintain the damage was due to a broken mains pipe underneath their
property, which caused the footings to be inundated with water.
1.2 Issues and key findings
Was the FSP entitled to deny the Applicants’ claim?
The FSP was not entitled to deny the Applicants’ claim because:
the Applicants established an insured event occurred
the FSP failed to prove the pipe broke due to soil movement or any other
causes excluded from cover.
Are the Applicants entitled to loss of rent?
The Applicants are not entitled to be paid loss of rent because the policy does not
provide cover for such loss.
Are the Applicants entitled to compensation?
The Applicants are entitled to compensation in the sum of $1,500 because they
have suffered an unusual degree of inconvenience because of the FSP’s handling
of their claim.
1.3 Determination
This Determination is substantially in favour of the Applicants.
The FSP is required to
accept the Applicants’ claim in accordance with the terms and conditions of
the policy. If the claim is cash settled, interest is payable at the statutory rate
from 18 July 2014 until the date payment is made i n accordance with Section
57 of the Insurance Contracts Act 1984 (the Act).
reimburse the Applicants the cost of expert reports obtained in support of their
claim (subject to invoices/receipts as proof)
pay the Applicants compensation in the sum of $1,500.
Case No: 373345 Determination Page 2 of 10
2 Reasons for Determination
2.1 Was the FSP entitled to deny the Applicants’ claim?
Policy covers loss or damage caused by water escaping from a pipe
The Applicants’ policy covers their home for loss or damage caused by a number
of listed events. Accordingly, the policy only responds where damage is caused
by one or more of the listed events, subject to any exclusions.
Specifically, the policy covers loss or damage caused by water or liquid escaping
from a fixed pipe, or an object attached to a pipe, fi xed gutter, fixed tank or a
drain.
The policy excludes loss or damage caused by or as a result of a number of
conditions including:
settling,
shrinkage,
any movement of earth,
erosion,
rust,
corrosion,
gradual deterioration,
depreciation,
wear or tear,
structural defects, and
faulty workmanship or design.
A prima facie claim exists so the onus is on the FSP to prove an exclusion
It is accepted insurance law the onus is on an insured to show, on the balance of
probabilities, a claim falls within the scope of cover available under the policy.
This is called a prima facie claim. Once shown, it is then the responsibility of the
insurer to establish, on balance, the application of any exclusion which it relied
upon to deny a claim.
It is not in dispute the Applicants’ property has suffered structural damage. The
FSP accepts the water leak contributed to the damage to the property but says
soil movement caused the pipe to break. The FSP says pre-existing damage to
the property confirms soil movement had occurred prior to the water leak event.
As the policy provides cover for loss or damage due to water leaking from a fixed
pipe, a prima facie claim exists. Therefore the FSP needs to show the loss is
excluded from cover.
The expert opinions differ as to the proximate cause of the damage
The FSP says the proximate cause of the damage to the Applicants’ property was
soil movement because this is what caused the mains water pipe to break.
The FSP formed its view based on the opinion of its engineer (I). In his report
dated 12 February 2013, ‘I’ considered the following chain of events occurred:
Case No: 373345 Determination Page 3 of 10
Clay sewer line and storm water line suffered some damage due to minor
house foundation movement.
Leaking sewer line caused loss of fines and cohesion in sandy soils under the
footings.
Movement then caused the main water line to fracture and subsequently wash
away more soil fines exacerbating the subsidence of the dwelling.
A later report from ‘I’ dated 24 September 2013 indicated he could not confirm the
cause of the pipe damage. He said however, in his experience, it was often the
result of ongoing natural ground movement.
The FSP’s geotechnical consultant (A) did not believe the footing system had
sufficient structural integrity to cope with the ground moveme nt occurring. He said
there was strong evidence to indicate footing movement and distress occurred
prior to the mains water leak. His view was the water leak was the primary trigger
for the current distress. He noted the previous distress to the property had been
repaired.
The Applicants’ geotechnical consultant (B) considered general site settlement of
20mm to 50mm was common. He said this amount of settlement would not cause
rupture of pipe work. In his opinion, the proximate cause of the damage to the
property was the 35,000 litre water leak that occurred underneath.
B’s report shared the view of the Applicants’ engineer (J). J noted there was no
substantial cracking in the brickwork at the property at the time it underwent pre -
purchase inspection. J also considered there would be widespread damage to the
properties and infrastructure surrounding the Applicants’ home if the extent of the
soil movement prior to the water leak was as bad as purported by I and A.
FSP has not proven the pipe broke as a consequence of soil movement
There appears to be no dispute the Applicants’ property suffered some
settlement/cracking prior to the water mains event. However, the extent of this
settlement appears to have been within an acceptable range.
The pre-purchase inspection report completed in July 2010 notes no major
damage at the property. The ‘undetected structural damage risk’ was recorded as
‘low’. The entry condition report completed by the Applicants’ property manager in
May 2011 also indicates no cracking was evident at that time.
Furthermore, similar damage to surrounding properties and infrastructure would
be expected if the soil movement was significant pre-incident; such damage was
not observed (as indicated by J in his report).
There is no clear evidence to show the extent of the soil movement would have
been enough to damage the pipes at the property. Furthermore, the plumbing
report indicates there was a split in the pipe, which is not suggestive of damage
caused by movement.
The FSP has therefore not shown, on balance, soil movement caused the
damage to the pipe. It has therefore not proven the exclusion it is relying upon to
deny the Applicants’ claim.
Case No: 373345 Determination Page 4 of 10
2.2 Are the Applicants entitled to be paid loss of rent?
Loss of rent cover is not provided by the policy
The Applicants’ policy provides cover for loss or damage due to a number of
defined events subject to conditions and exclusions. However, the policy does not
provide any cover against loss of rent.
2.3 Are the Applicants entitled to receive compensation?
Applicants suffered an unusual degree of inconvenience
FOS can award an Applicant compensation of up to $3,000 for non-financial loss
where the Applicant experienced an unusual degree or extent of physical
inconvenience, time taken to resolve the dispute or interference with his or her
expectation of enjoyment or peace of mind.
The FSP did not handle the Applicants’ claim efficiently. It took 18 months to
reach a final decision on the merits of the claim. The delays in reaching a decision
brought about significant stress and hardship for the Applicants.
The condition of the property made it unsafe for habitation. The Applicants
suffered a significant financial loss as a result of not being able to obtain rental
income for the period in which the claim was being considered. This would have
also interfered with the Applicants’ expe ctation of enjoyment or peace of mind.
The Applicants have therefore established an entitlement to compensation.
Taking all matters into account, the Panel considers an amount of $1, 500 is fair
in all the circumstances.
2.4 Are the Applicants entitled to receive compensation for costs?
Applicants are entitled to compensation for professional costs incurred
The Applicants have incurred costs in obtaining engineering and geotechnical
advice in response to evidence obtained by the FSP.
Under paragraph 9.4 of the FOS Terms of Reference, FOS may require a
financial services provider to contribute to legal or other professional costs
incurred by an applicant in the course of their dispute.
The Panel is satisfied it was necessary for the Applicants to obtain their own
expert evidence. The nature of the issues involved in the dispute required the
Applicants to obtain professional advice and the expert reports obtained have
been critical in determining the outcome.
The FSP is therefore required to reimburse the Applicants the cost of the expert
reports obtained (subject to receipts/invoices as proof).
Case No: 373345 Determination Page 5 of 10
3 Supporting information
3.1 FOS approach to this dispute
As advised to the parties, FOS considered it appropriate to expedite the dispute in
accordance with the Operational Guidelines to the FOS Terms of Reference. This
is because of the nature and complexity of the matter. This dispute has not been
the subject of a FOS Recommendation and has proceeded directly to
Determination.
This decision has been made by a Panel consisting of an Ombudsman and two
representatives with extensive experience in insurance and consumer claims.
A full exchange of the relevant information has taken place between the
respective parties and each party has had the opportunity of addressing any
issues raised.
All of the provided material has been read and considered. The parties have
raised numerous issues in their submissions to the Service. For the purpose of
this Determination, commentary is restricted to only those issues considered
relevant to the outcome.
3.2 Key documents
Record Key points
Pre - purchase
Inspection Report
15 Jul 2010
Small crack in hall ceiling.
2 cracked tiles on internal stairs.
Bandage cracking in Bed 3 ceiling.
Some sill tiles missing on balcony.
Some paint peeling on rumpus room ceiling.
Some doors hitting on kitchen cabinets.
Retaining walls: good.
Pergola: Good.
Significant defects or matters: none listed.
Additional Comments: Only concern was downpipe not
hooked up to storm water.
No crackin g to the building elements.
Overall condition of property in context of average
condition of similar building of same age: Average.
Undetected structural damage risk: Low.
Site drainage at time of inspection: Good.
Entry Condition Report
28 May 2011
No cracking noted.
City Council – Water
Consumption Advice
20 Dec 2012
4615L/day vs 3082L/day last quarter
Suggest check for leak
Case No: 373345 Determination Page 6 of 10
Apps’ expert (N)
Report
29 January 2013
N inspected the property and the entry condition report
and concluded the settlement observed occurred over
about 1 ½ years
After review of the site and the documentation it was
this structural engineer’s opinion that the damage had
occurred as a result of the recently repaired plumbing
defects
FSP’s expert (I)
Report
12 Feb 2013
Easter n side of the dwelling and eastern veranda are
not structurally sound.
Visual inspection of the house confirms the soil
underneath the house on the eastern side has eroded
due to a prolonged mains water leak.
Inspection revealed a large amount of cracking in the
walls present for some time – most of the cracks were
repaired and repainted years prior to the leak being
discovered.
Fresh re - cracking of the previously damaged walls is
due to new stress to the walls caused by the foundation
movement where the w alls were already weakened.
Two plumbers’ inspections recently identified footings
sewer line near the footings and a storm water line had
leaked for some time (10/1/13).
Second inspection 19/1/13 identified a water main leak
which was repaired by the atte nding plumber.
Loss events occurred in the following order: clay sewer
line and storm water line suffered some damage due to
some minor house foundation movement, the leaking
sewer line caused loss of fines and cohesion in sandy
soils under the footings, l oss of fines and cohesion
caused severe movement of footings, movement
caused the main water line to fracture and
subsequently wash away more soil fines exacerbating
the subsidence of the dwelling.
Apps’ Plumber
Report
20 Feb 2013
Leak located underground at back left hand corner of
house near laundry.
Poly water pipe had a large split in the bottom of the
pipe.
FSP’s expert (I)
Report
24 Sep 2013
Leaks are located upslope from the veranda cracking
indicating a relationship betwee n the damage and the
leaking.
As well as the new damage noted evidence of minor
prior cracking/repairs.
Existing cracking is located across the rear elevation
closest to the water and although there is a slight
possibility that tidal changes could have so me effect it
is our opinion (based on observations/evidence) the
cracking is related to the water leaks.
Whilst some cracking would be a result of ongoing
minor settlement the majority of the damage is the
result of erosion resulting from the water leaks.
Case No: 373345 Determination Page 7 of 10
The pipes damaged appeared to be aged. We cannot
confirm the cause of the pipe damage but in our
experience pipe damage is often the result of ongoing
natural ground movement.
FSP’s Expert (A)
Report
4 Feb 2014
When this dwelling was built there was no
understanding of the fact that buildings move on soils
so no allowance was made for articulation joints which
would absorb most movement without cracking.
A drainage issue on site went unrepaired for some time
and significant cracking noticed after. Und erlying soils
were always going to settle to some degree and as the
structure was unarticulated there was always going to
be some cracking and distress.
Because the dwelling is rendered the challenge is to
determine whether there was any old damage which
may have been disguised by previous owners which
was reactivated by the recent drainage event and what
is new damage only related to the drainage event.
FSP’s expert (I)
Report
6 Feb 2014
The geotechnical report reinforces the point the
movement issues at the dwelling are ongoing thus only
a portion of the damage/cost of the repairs should be
related to the leak.
Slab level surveys have indicated the dwelling slab has
not moved significantly since the leak events were
reported.
FSP’s expert (I)
Report
3 Mar 2014
Damaged retaining walls and soil stability concerns
which would contribute to the movement issues.
Insured claimed plumbing leaks at the property caused
the damage however in our opinion, ongoing pre -
existing damage has reoccurred.
All areas conc erned comprise pre - existing damage.
The area which has subsided comprises repaired
cracked masonry directly above.
All ongoing issues would pre - date the leaks, thus it is
possible the ongoing issues caused the movement
which resulted in the damage to the p lumbing services.
All reports written prior to geotechnical investigation
made the assumption the building platform and general
earthworks prior to the initial construction would have
been adequate for the intended loads and design.
Therefore it would be n atural to assume ground
movement would not occur unless some other influence
has been encountered such as leaking water pipes or
storm and flood issues. The geotechnical report has
found that assumption to be false and has highlighted
the likely issues wit h the construction of the site itself as
well as possible contributing effects due to the design
of the building and the footings.
Concrete masonry appears to be unreinforced and not
core filled. Due to lack of reinforcement the masonry
Case No: 373345 Determination Page 8 of 10
has very little ten sile capacity. Therefore as settlement
occurs the masonry is placed under tension and
cracking can begin to occur.
Combination means the issues noted across the site
were always likely to occur regardless of any water
leaks.
Damage to the retaining walls, stairs and boundary
fence is considerably older than the time frame of the
water leak. This has not been caused by the water leak.
Pipes in non - reactive soils generally do not fail for no
reason. As non - reactive soils do not shrink and swell
due to moistur e change then the likelihood of these
failing due to soil reactivity causing tension in the joints
of pipes themselves or rubbing of the pipes on other
subjects, is minimal.
The only reasonable explanation for why two separate
pipes would fail at two separate times is due to
settlement issues of the building due to the insufficient
bearing capacity of the soils and or movement of the
soils.
Based on the age of the damage to t he retaining wall, it
is most likely this failed first, once this failed, the non -
cohesive soils started to move toward the canal and the
pipes either lost support and failed or alternatively were
pushed by the weight of the soil out of position causing
th e failure.
Water leaks are most likely a consequence of
settlement of the building and/or the movement of
underlying soils away from the building after the failure
of the retaining structures in the eastern corner.
While the water leaks may have exacerbat ed pre -
existing damage that cracking would have been
present regardless.
Apps’ Expert (J)
Report
29 Apr 2014
Cracking was only present in the vicinity of the water
leak zone with the remainder of the house showing no
major signs of significant foundati on movement apart
from normal settlement.
Review of the pre - purchase report indicates there was
no cracking in the brickwork and internal linings. The
report indicates there was no evidence of foundation
movement when the property was purchased.
The evide nce from the pre - purchase report
substantiates there is no cracking evident in 2010 and
the evidence suggests the cracking is not the result of
long term foundation movement.
The evidence indicates the foundation movement to the
dwelling is a result of si gnificant underground water
flow from a leaking pipe causing the foundations to
subside.
Apps’ Expert (B) Broadly estimated settlements across the building as a
Case No: 373345 Determination Page 9 of 10
Report
19 May 2014
result of the original construction could possibly have
been of the order of 30mm to 50mm and would have
occurred at the time of construction with no ongoing
settlement anticipated at the time of the current building
damage (unless affected by vibration or disturbance).
Hydraulic levels survey indicates settlements of up to
173 mm. Also, survey indicates area of greatest
settlement is coincident with the area of the reported
leak.
Unlikely house movement is the result of instability.
Most likely reason for the damage is significant adverse
settlement occurring in part of the si te due to 35,000
litre water leak that occurred beneath the existing
structure.
FSP’s expert (I)
Report
16 Jun 2014
Prior to re - inspecting the property after first preliminary
tender the insured indicated he did not agree with the
proposed repairs. When attending the property many
more issues were raised including subsidence. It was
our understanding the insured did not accept the scope
thus settlement was disputed.
Insured has said on multiple occasions he was
unaware how noticeable the repairs to the b rick work
were. Insured said he did not repair cracks so assume
they are pre - existing.
Settlement between 20mm to 50mm more than
sufficient to cause damage to plumbing systems.
App’s reports do not comment on pre - existing crack
repairs. Also did not addre ss cause of damage to
plumbing.
Do not dispute leak would exacerbate damage to the
dwelling however the damage to the pipes is most likely
the result of settlement to the dwelling due to ongoing
issues.
FSP’s Expert (A)
Report
23 Jun 2014
Footing system has insufficient structural integrity to
cope with the ground movements occurring on the site.
Prior to recent water leak there is clear and strong
evidence that footing movement had occurred and that
significant distress had occurred.
The recent water leak has been the primary
trigger/cause of the majority of the distress which is
now visually obvious i.e. the recent distress as the
previous distress had been repaired.
Virtually impossible to determine whether the water
leak just accelerated what would have happened in
time. Can only give opinion which is further cracking will
occur and water leak has just accelerated damage.
Apps’ Expert (J)
Report
21 Aug 2014
The observed damages are limited to the dwelling in
question. Seeing estates are dev eloped with multiple
lots at one time it would be expected that if there is a
fundamental failure to the subdivision, indicators of
Case No: 373345 Determination Page 10 of 10
failure would be observed to numerous neighbouring
dwellings, street drainage, road surface and fences –
none of this was ob served.
If there was long term movement the ongoing claimed
repairs would be far more obvious. The claimed
previous repair evidence is very limited in comparison
to the strong evidence of recent cracking damage.
Had the observed damage been evident in the pre -
purchase report this would have been clearly
documented due to the severity of the cracks.
The evidence indicates the damage is the result of an
underground pipe leak.
Apps’ Expert (B)
Report
28 Aug 2014
It is not unusual for building foundations to move and
some cracking is common. Most buildings constructed
with footings that conform to the current Aust. standard
will not suffer any damage, however, the standard
acknowledges there will be a low incidence of Cat 1
damage and occasionally Cat 2 damage.
The reporting of the previous cracking unless moderate
or severe is within the range of expected performance
rather than being evidence of an ongoing problem. It
should be noted the damage caused to the dwel ling by
the leak is of a higher category (3 or 4) than would be
expected.
General site settlements of 20mm to 50mm commonly
occur and would not be expected to cause rupture of
pipe work.
Site is underlain by sand, consolidation would have
almost certainly occurred in its entirety during
construction or shortly thereafter. Long term settlement
can occur in compressible clays – no evidence of
compressible clay soils at site. Ongoing settlement of
the sand would only occur where additional surcharge
load is a pplied or the sands are subject to vibration,
inundation or other disturbance.
Movement not the result of slope stability issues –
movement of 173mm due to water leak and would not
have occurred without water leak or some other
significant site disturbanc e.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.