Home / Financial Firm (Unknown - Insurer) / Determination 372228

Determination 372228

Engine damage claim denied as wear and tear

FirmFinancial Firm (Unknown - Insurer)
Decided2015-07-27
ProductGeneral Insurance · Motor
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss$500
Amount claimed—
SourceAFCA PDF

Summary

The applicant's comprehensive motor claim for engine damage was denied as caused by wear and tear. AFCA upheld the denial but ordered the FSP to pay $500 for excessive delay in handling the claim.

The FSP's expert evidence on fatigue cracking established the wear and tear exclusion on the balance of probabilities, while the FSP's delay in progressing destructive testing warranted compensation.

Issues

Subjects and remedies

pay non financial loss

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Motor Vehicle- Comprehensive - FSP Decision - Denial of claim Determination Case No: 372228 Determination Page 1 of 8 Case number : 372228 23 June 2015 1 Overview 1.1 Dispute The Applicant lodged an insurance claim for damage to his vehicle’s engine. He says a collision with a rabbit caused a leak in an oil pipe, resulting in engine failure. The Financial Services Provider (FSP) denied the claim on the basis that the cause of the pipe leak was wear and tear, which is excluded from cover. 1.2 Issue and key findings Is the FSP entitled to deny the claim? The FSP is entitled to deny the claim for the damage to the engine of the Applicant’s vehicle , because the FSP has established that the crack was caused by wear and tear. 1.3 Determination This Determination is substantially in favour of the FSP. The FSP must pay the Applicant $500 for its excessive delay in handling the claim. Case No: 372228 Determination Page 2 of 8 2 Reasons for Determination 2.1 The FOS Approach I have determined this dispute based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous Financial Ombudsman Service (FOS) decisions. I have taken into account all the material submitted by the parties, both before and after the Recommendation was issued. There has been a full exchange of all documents relied on to make this Determination and each party has had the opportunity to address any issues raised by the other. 2.2 Is the FSP entitled to deny the claim? The Applicant has established a claim under the policy The Applicant states that while drivi ng his four wheel drive Toyota Landcruiser he swerved to miss a rabbit (which he hit) resulting in him driving on the unsealed portion of the road. The Applicant submits it is possible the rabbit hit the oil pipe and / or that a tree branch or other debris was flung up against the pipe, causing it to crack. The policy provides cover for accidental damage. The courts have defined “accidental” in an insurance context as something that is “unintended and unexpected”. The damage to the Applicant’s vehicle was unintended and unexpected. As such, the Applicant has established the claim falls within the policy. The onus therefore shifts to the FSP to establish that an exclusion applies to entitle it to deny the claim. The FSP’s expert found the crack was caused by fatigue The FSP says that the cause of the leak in the oil pipe was wear and tear, which is excluded from cover under the policy. The FSP’s expert, P, conducted a non -destructive examination of the pipe as well as destructive testing. P concluded that the crack was fatigue in nature and not caused by a single overload event (such as impact with a small animal). P stated:  Microscopic examination of the pipe showed that the external appearance was characteristic of fatigue cracking.  The area of the crack was in the area of the welded bracket and welds are particularly prone to fatigue cracking .  The crack face revealed scanning electron microscopic features indicative of fatigue cracking across the full wall of the thickness of the tube. Case No: 372228 Determination Page 3 of 8  There was no evidence of dimpled features, which are associated with ductile fractures.  There was no evidence of plastic deformation of the tube as would be expected if it was a ductile fracture.  There was also no evidence of cleavage or intergranular fracture, which is associated with brittle fractures.  There was localised wear of the coating at the end of the tube, which is characteristic of rubbing between surfaces and suggests relative movement. This is consistent with fatigue cracking.  The paint damage to the side of the tube was indicative of very localised point contact and not from a blunt body.  The crack was likely to have been present for a significant period of time and eventually propagated through the wall thickness.  There was no evidence of a single load event that caused the crack. P ’s previous report stated:  The orientation of the crack suggested some torsion superimposed on bending, as the likely stress condition causing the cracking  Vibration can be the source of the initiation and propagation of fatigue cracks. The Applicant says P’s report s are flawed The Applicant raised a number of criticisms with P’s reports (including P’s independence), after identifying the three stages of fatigue cracks. They were:  P failed to identify where the cyclic stresses originated from, or what caused them.  Oil would have been visibly leaking during all three stages of the fatigue crack over a period of time. No such leaks occurred.  The direction of the crack suggests that pressure has been applied from above or below, consistently with something hitting it from the underside of the vehicle.  The loss of coating at the end of the tube is perfectly normal for this is where the pipe is tightened when installed and it is not uncommon for paint to be dislodged by the process (as well as when it was removed). This is confirmed by the Applicant’s mechanic, G.  There is nothing in the area of the pipe that moves or rubs and G confirmed that all anchor points were tight.  There are marks on the side of pipe that are evidence of a single overload event. This could be from a tree flung up under the car when he swerved to try and avoid the rabbit.  No other engine part has failed from vibration.  The incident with the rabbit may have caused the final stage of the fatigue crack.  The manufacturer does not expect the part to fail through ordinary use of the vehicle. It does not recommend the change of the pipe as part of the routine maintenance of this type of vehicle and it is not kept in stock. Case No: 372228 Determination Page 4 of 8 On balance, the FSP has established the crack was caused by fatigue Having considered all the evidence, on balance, I am satisfied that the FSP has established the crack was a fatigue crack and therefore fits within the wear and tear exclusion. The vehicle was 13 years old and had travelled nearly 350,000 km at the time t he damage occurred. This increases the likelihood (but does not determine) that the oil pipe failed due to wear and tear through ordinary use. P utilised a scanning electron microscope to examine the fracture. P therefore had access to technology, that was not available to the Applicant, to assist in identifying the type of fracture. There was no evidence of a ductile or brittle fracture. While the fracture would have occurred over a long time, it did not propagate through the wall thickness until the final stage of cracking. As such, oil would not have been leaking during the period of time the fracture was present. In addition, the position of the pipe in the engine was not easily susceptible to impact damage. While I am satisfied the fracture is due to fatigue, it is not clear what has caused the wear and tear on the pipe other than just age and mileage. There are no moving parts in the area of the pipe. The references to the wear on the removal of paint on the end of the tube have been explained by the Applicant and his expert, G. The paint damage to the side of the tube, which the Applicant says is consistent with damage as described by him, was inadequately explained by P as “indicative of a very localised point contact and not from a blunt body”. Having considered the evidence from the respective parties, I am satisfied on the balance of probabilities, that the fracture was caused by fatigue and likely as a result of general wear and tear, particularly given the age of the insured vehicle and the kilometres travelled. As such, the FSP is entitled to rely upon the exclusion clause to deny the Applicant’s claim. In reaching this conclusion, I have considered the Applicant’s submission that the incident of the rabbit may have been the final stage of the fatigue crack. Had this been the case (as it may well have), the proximate or dominant cause of the crack would still be wear and tear and therefore excluded by the policy. The FSP is entitled to deny the claim. The FSP delayed the handling of the claim The Recommendation was issued on 25 February 2015, which the FSP rejected on 2 April 2015 on the basis it wished to undertake destructive testing (the FSP’s failure to do this being the main reason the Recommendation was not in its favour). It was not until 20 May 2015, that the FSP sought to arrange collection of the pipe with P’s report being provided on 3 June 2105 and the FSP’s submissions on 5 June 2015. Case No: 372228 Determination Page 5 of 8 Given a proper investigation of the Applicant’s claim (which was submitted to the FSP on 3 July 2014) should have included the destructive testing, it is fair in all the circumstances for the FSP to pay the Applicant $500 for the undue delay in the resolution of the claim. Case No: 372228 Determination Page 6 of 8 3 Supporting information 3.1 Policy provisions Comprehensive This insurance is designed to cover you for theft or accidental damage to the insured vehicle which occurs during the period of insuranc e up to the amount of the sum ins ured or other specified maximum limit. … When you are not insured You are not insured for; Theft or damage to your vehicle For example, but not limited to; … … When the damage is: (i) The result of normal wear and tear, rust or corrosion to your vehicle (ii) Structural failure, electrical or mec hanical breakdown Wear and tear of your vehicle or t railer res ulting from ageing or loss of value through ordinary use. We would not pay to repair rust damage, a worn out engine, old radiator and water hoses or a faulty electrical system 3.2 Expert reports Record Key points FSP’s expert (P ) Report 17 Jul 2014  M icroscopic examination showed that the external appearance was characteristic of fatigue cracking - welds are particularly prone to fatigue cracking  Absence of obvious plastic deformation is not consistent with ductile failure  Orientation of the crack ( inclined to a circumferential plane ) suggests some torsion superimposed on bending as a likely stress condition causing the cracking  V ibration can be the source of the initiation and propagation of fatigue cracks  Likely failure mo de is fatigue cracking and not a result of a single overload event.  For additional confidence destructive testing would be required involving exposing the crack faces Applicant’s expert ( CS ) email 29 Sept 2014 “...from the information that you have presen ted to me that item in question is the oil feed banjo that feeds the vacuum pump. There is no modified parts, this is not a know issue and it is not common for us to have to replace them either. Over all the times I have only ever seen one leak and that is it…” [sic] Case No: 372228 Determination Page 7 of 8 Record Key points Applicant’s expert (PC) e mail 30 Sept 2014 “ Currently we are not aware of any issues of this nature. We have not seen the problem here before either. We would need to inspect the vehicle to assess why the failure has occurred (whether there are any external factors that contributed to the failure)” Applicant’s expert (PY) email 30 Sept 2014 “I enquired with our service department, they have never struck this, I can imagine one pipe failing over time but I would think a new replacement would last as long as the original.” Applicant’s expert (AS) email 30 Sept 2014 “This is not something I have seen before so it doesn’t appear to be a common issue or a wear and tear item. I have spoken to our parts department and they think that the part has not been revised previously. Hopefully this is a one off and doesn’t occur again for you.” Applicant’s repairer (G) e mail 8 Oct 2014 “In regard to the high pressure oil pipe in question, I can confirm that both banjo bolts at each end of the pipe and the support bracket and bolt were tight when I was requested to remove the pipe for testing.” FSP’s Assessor (RC) Report 8 Oct 2014  No sign at all of any impact which could be caused by a rabbit to damage the under body of the vehicle, bottom of the radiator or air condenser  A lso no impact damage to the oil pipe as per the claim.  There appears to be no other repairs carried out under the bonnet to the engine - confirmed with Applicant  The dent to the front bull bar is old damage and not consistent with this claim - confirmed with Applicant . FSP’s expert (P) Report 3 June 2015  The crack face was opened and visually examined using a scanning electron microscope.  Deformation from the opening indicated that the tube was ductile.  The wall thickness in the initi ating area was measured 0.85mm whilst about 1cm axially from the crack wall thickness was 0.72mm.  The area of th e crack was in the area of the “ welded” bracket.  The fracture had a relatively uniform appearance across its face.  The crack face revealed so me mechanical damage.  The crack face revealed SEM features indicative of fatigue cracking across the full wall thickness of the tube.  There was no evidence found of dimpled features, which are associated with ductile fracture.  Ductile fracture for inherently ductile materials, such as with this tub e, has associated visible plastic deformation (permanent distortion) of the material. There was no visible Case No: 372228 Determination Page 8 of 8 Record Key points evidence of such plastic deformation of the as received tube.  Similar to the absence of ductile failure, there was no evidence of cleavage or intergranular fracture, which is associated with brittle fractures.  The localis ed wear of the coating (on the end of the pipe) was characteristic of rubbing between surfaces and suggests relative movement. Thi s is consistent with fatigue cracking.  The damage to the pain t on the side of the pipe was more indicative of very localis ed point contact and not from a blunt body.  The cracking of the tube was of a fatigue nature, which is a slow propagating cracking m echanism. The crack was likely to have been present for a significant period of time and eventually propagated through the wall thickness.  Fatigue commonly occurs due to fluctuating loads and this was consistent with the p resence of locali sed type wear of the paint.  There was no evidence of a single load event causing the crack. Applicant’s expert (G) 17 June 2015  The section of the pipe that P referred to as “localised coating wear” (being paint missing) is where the sealing crush washers are located.  I would expect this to be normal when the banjo bolt is tensioned up against the crush washers and pipe.  This was probably done when the engine was built in the factory.  I would also expect to see paint missing on the removal of the banjo bolt from the pipe end which I removed at the insurance company request.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.