Home / Financial Firm (Unknown - Insurer) / Determination 370713

Determination 370713

Claim refused for movement damage under earth movement exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2015-02-13
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant sought cover for building movement damage after a leaking water main; the FSP accepted carpet damage but refused the house movement damage. AFCA found the damage was caused by naturally occurring earth movement, which is excluded.

The proximate cause of the movement damage was earth movement from moisture changes, tree effects and drainage, so the general earth movement exclusion applies.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - Service - Service Quality - FSP Decision - Denial of Claim - Exclusion/Condition Determination Case No: 370713 Determination Page 1 of 7 Case number : 370713 1 3 February 2015 1 Overview 1.1 Dispute The Applicant lodged a claim under her home building and contents insurance policy with the Financial Services Provider (FSP) for movement damage to her house and water damage to the carpet. The Applicant advised that the damage was due to a leaking pipe. The FSP accepted liability for the damage to the carpet but denied liability for the damage to the building, on the basis that this damage was not caused by the leaking pipe, but by naturally occurring earth movement, which is excluded under the policy. 1.2 Issues and key findings Is the FSP liable for the movement damage to the house? The available information establishes that the movement damage to the Applicant’s house was not caused by the leaking pipe but by earth movement resulting from long term moisture changes in the sub-floor soil due to seasonal and climatic changes, the effect of trees near the house and poor surface drainage. Damage caused in this manner is not covered under the policy. 1.3 Determination This Determination is in favour of the FSP. The FSP is not liable for the movement damage to the Applicant’s house. Case No: 370713 Determination Page 2 of 7 2 Reasons for Determination 2.1 Is the FSP liable for the movement damage to the house? Application of policy depends on cause of damage The Applicant’s policy provides cover for damage to her property caused by the events listed in the policy (including the escape of liquid from a fixed pipe), subject to the conditions and exclusions set out in the policy. The policy contains a general exclusion for damage that is caused by, arises from or involves erosion, subsidence, shrinkage or any other earth movement (other than landslide or subsidence that is specifically covered under the insured events of storm, flood, earthquake, tsunami or explosion). The available information establishes that a broken main water pipe was discovered under the Applicant’s property in or around March 2014, which caused water to leak into the sub-floor area. It is likely that the leak was present for a few months before being identified. The FSP has accepted liability for the damage to the carpet in the basement area caused by water escaping from the leaking pipe. However, the FSP says that the movement damage to the Applicant’s house (which has resulted in doors on the ground floor not closing properly) was not caused by water escaping from the leaking pipe, but was due to naturally occurring earth movement which is excluded under the policy. Accordingly, it is necessary to determine the proximate cause (that is, the real, effective or dominant cause) of the movement damage to the Applicant’s home . Building damage was not caused by leaking pipe Having carefully reviewed the available information, the Panel is satisfied, on balance, that the leaking pipe was not the proximate cause of the movement damage to the Applicant’s house. The engineer (F) appointed by the FSP to determine the cause of the damage concluded that the volume of water discharged from the leaking pipe over a period of several months was insufficient to penetrate the foundation soils in which the footings of the building were founded, to a depth which would increase the moisture content of the soils thereby causing movement damage to the building. The FSP’s engineer (F) also noted that floor level surveys of the building showed a pattern of building movement which was not consistent with the movement having been caused by the leaking pipe. In particular, F noted that:  given the slope of the land, any water discharged from the pipe would be expected to flow towards the north west corner of the house, which was not the area where the claimed damage had occurred . However, the floor l evel surveys did not show footing movement consistent with an increase in foundation soil moisture content caused by water pooling in this area ; Case No: 370713 Determination Page 3 of 7  even if water from the leaking pipe had penetrated the foundation soils to a significant depth, this would have caused the soils to swell, resulting in footing “heave” (upward movement). However, the floor level surveys showed a footing settlement (downward movement), which results from shrinkage of the clay soils caused by a reduction in soil moisture content; and  further, the pattern of footing settlement revealed by the floor level surveys was most pronounced towards the north-east corner of the building, which was not where the leaking pipe was located. Having regard to the features of the site, F concluded that the damage to the Applicant’s house had been caused by naturally occurring earth movement resulting from long term moisture changes in the foundation soils due to factors such as seasonal and climatic changes, the effect of trees near the house (which draw moisture from the soil) and poor surface drainage around the house. The Panel considers that, as an engineer, F is appropriately qualified to determine the cause of the movement damage to the Applicant’s house . F ’s report provides a reasonable explanation as to how the movement damage occurred, which appears consistent with the observed facts. The Panel acknowledges the Applicant’s position that the movement damage to her house only became apparent around the same time as the water leak. However, in the absence of independent information which refutes the findings of the FSP’s engineer, the Panel is satisfied that, on the balance of probabilities, the movement damage was not caused by the leaking pipe, but by naturally occurring earth movement. FSP is not liable for movement damage For the reasons outlined above, the Panel is satisfied that the movement damage to the Applicant’s house was not caused by the leaking pipe or by any other insured event under the policy. The policy exclusion for damage caused by earth movement would also apply. Accordingly, the FSP is not liable for the movement damage. Case No: 370713 Determination Page 4 of 7 3 Supporting information 3.1 Panel approach to this dispute This dispute has not been the subject of a FOS Recommendation. Due to the nature of the dispute, it has been referred directly to a Panel for Determination, in line with the Operational Guidelines to the FOS Terms of Reference. The Panel consists of an Ombudsman and two representatives with consumer and insurance experience. The Panel has decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous Financial Ombudsman Service (FOS) decisions. There has been a full exchange of all material information relied on for the purposes of this Determination and each party has had the opportunity to address any issues raised by the other. The Panel has reviewed and considered all of the material provided by the parties. While the parties have raised numerous issues in their submissions, for the purposes of this Determination, the Panel has restricted its commentary to those issues which it considers directly relevant to the outcome only. 3.2 Terms of policy Subject Terms Insured event – escape of liquid We cover Loss or damage caused by liquid leaking, overflowing or bursting from any of the following: …  any drain, fixed pipes, roof gutters or guttering and rainwater downpipes, drainage and sewage systems General exclusion - ground movement You are not covered under any section of this policy for damage, loss, cost or legal liability that is caused by, arises from or involves :  erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement, but we will cover landslide or subsidence that is specifi cally covered under the following insured events: - Storm - Flood; - Earthquake and Tsunami ; - Explosion. Case No: 370713 Determination Page 5 of 7 3.3 Reports Re port Key points FSP’s builder (H) Report – April 2014  T he pro perty is approximately 60 years and there is no indication of prior damage  The Applicant had advised that she had recently noticed water entry to the sub - floor storage room, which was found to be coming from a leaking pipe below the house but uphill from this area.  At around the same time, the Applicant had noticed that three i nternal doors leading to rooms off the main hallway had become difficult to close.  An inspection underneath the house revealed some areas where the dampness of the soil appeared to be elevated above normal levels, while other areas appeared to be relatively normal.  There was no indication that the problems with the doors were due to the leaking pipe .  I t was likely that differential movement within the house due to normal seasonal changes in soil moisture may have been exacerbated by the leaking pi pe .  A n engineer should be appointed to report on the cause of the damage. F SP’s e ngineer ( F ) Report - 11 July 2014  The house was approximately 50 years old and the Applicant had lived there for 36 years .  A rumpus room had been built under the ground floor in the north west corner of the house, using concrete bricks on a strip footing.  The property had a moderate slope from the south east to the north west and there we re large trees to the west and medium sized trees to the east in relative ly close proximity to the house .  T he sub - floor appeared to be dry . There was excavation apparent adjacent to the stumps next to the masonry wall of the rumpus room.  A floor level survey identified a maximum floor level variation of 66mm. There was a patter n of relative footing settlement towards the north east corner of the building.  The Applicant had advised that her last water bill approximately three months earlier was slightly higher than usual. A leaking water main under the kitchen was discovered approximately one month after this and repaired shortly after.  Based on geological survey data, the house was built on reactive foundation clays , which react to variations in moisture content by heaving , swell ing and/or shrink ing.  I n order for water inunda tion to affect structural footings , the inundation must be of a degree and duration to enter to sufficient depths to increase the moisture content of the foundation clays into which the structural footings a re Case No: 370713 Determination Page 6 of 7 Re port Key points founded.  T he volume and duration of the water discharged from the leaking pipe was insufficient to penetrate the foundation soils. If this had occurred, it would be expected to result in s w elling of the foundation soils, causing footing heave.  Given the topography of the site, any discharge of water w ould be expected to flow towards the north west corner, remote from the area of damage.  The floor level survey showed no sign of footing heave and did not reflect a pattern of footing movement along the west side of the building consistent with an increase in the foundation moisture content caused by po o ling water.  Rather, the level survey showed a degree of differential footing movement in the area of the sticking doors which was consistent with that expected for a building of the age and construction as the Applicant’s house, under normal soil moisture conditions over time .  There was a discernible pattern of footing settlement towards the trees in the northeast corner. This was generally not symptomatic of an increase in soil moisture content, but rather with clay shrinkage caused by a reduction in soil moisture content. Further, the area of footing settlement was not in the area of the leak.  In summary , the movement damage was due to differential movement caused by variations in soil moisture content as a result of the effects of large trees in close proximity to the building , changes in soil moisture le vels due to seasonal and climatic effects and drought condition s in the area between 1997 and 2 010 followed by the return of “normal ” rainfall patterns . Usual seasonal expansion and contraction of building materials due to changes in atmospheric moisture levels may also have contributed. F SP ’s en gineer (F) Supplementary report - 6 October 2014  A s econd inspection of the property and a geo technical assessment was completed by a different engineer employed by F .  His observations were generally consistent with F’s earlier report. He also noted poor surface drainage conditions around the house with a m ixture of unsealed ground, garden and brick paving .  There was moisture staining to the soil surface under the kitchen/living area, in the approximate area of the leaking pipe, with sig n s of water flow in a north - west direction consistent with the natural slope of the ground.  The majority of the stumps under the house (and most notably, the stumps under the location of the jamming doors) were moisture stained. This moisture would appear to be coming from the natural ground/landscaping to the south - east corn er of the house.  The retained soil along the east wall of the house showed Case No: 370713 Determination Page 7 of 7 Re port Key points signs of prior water entry from poor surface and sub - surface drainage.  The site would normally be class ified as “Class M” ( moderately reactive soils ). H owever , given the presence of large trees , the site would be classified as “ Class P” (p roblem site ).  The Applicant advised that the water provider had confirmed a more than doubling of normal water use between January and May 2014.  T he geotechnical findings confirmed the conclusions as to cause of damage in F’s earlier report. The water main leak event did not cause or contribute to the observed movement damage to the building .

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.