Home / Financial Firm (Unknown - Insurer) / Determination 368604
Determination 368604
Trailer chassis failure denied under wear, tear and faulty design exclusions
Summary
A landscaping business claimed for a trailer chassis failure during tipping, and the FSP denied it under wear, tear and faulty design exclusions. AFCA found the FSP had not established the exclusions and ordered cash settlement of the $31,500 market value less a $2,000 excess, plus interest.
The insurer bears the onus of establishing an exclusion, and the evidence did not show that wear and tear, faulty design or workmanship caused the failure.
Issues
- Claim denial primary · upheld
“The evidence does not establish the fracture was due to depreciation, wear and tear, rust or corrosion, or to faulty design or workmanship.”
- Inadequate claim investigation secondary · upheld
“The FSP's engineer identified that a metallurgist report should have been obtained to determine these issues. No report has been obtained.”
Subjects and remedies
pay claimpay interest
Text of the determination
Determination
General Insurance - Small Business/Farm Insurance - Commercial Vehicles - FSP
Decision - Denial of Claim - Exclusion/Condition
Determination
Case No: 368604 Determination Page 1 of 5
Case number : 368604 18 December 2015
1 Overview
1.1 Dispute
The Applicant, a landscaping business, lodged a claim under its commercial
motor policy for damage sustained to a 2002 tri-axle dog trailer when the chassis
failed during a tipping operation on or about 3 December 2013.
The FSP has denied the Applicant’s claim on the basis that the loss is excluded
under the policy.
1.2 Issue and key findings
Can the Applicant establish a prima facie claim?
The Applicant has established a prima facie claim because:
the policy provides comprehensive cover in the event of theft or accidental
loss or damage
accidental loss or damage is damage which is sudden, unintended and
unexpected
the chassis collapse was sudden, unintended and unexpected during a normal
tipping operation.
Can the FSP establish the application of a general exclusion?
The FSP has not established the application of a general exclusion because:
the damage was sustained due to combination of fatigue fracture and sudden
fracture
the evidence does not establish the fracture was due to faulty design or
workmanship
the evidence does not establish the fracture was due to depreciation, wear
and tear, rust or corrosion.
1.3 Determination
This Determination is in favour of the Applicant.
The FSP is to cash settle the Applicant’s claim for the market value of $31,500
plus interest pursuant to Section 57 of the Insurance Contracts Act 1984 (the Act)
from 4 March 2014 to date of payment of the claim.
Case No: 368604 Determination Page 2 of 5
2 Reasons for Determination
There has been a full exchange of material between the parties and each party
has had the opportunity of addressing the issues that arise from the material
exchanged.
This Determination is based on what is fair in all the circumstances, having regard
to the material exchanged, relevant legal principles, terms of the policy, good
industry practise and prior Determinations where applicable.
2.1 Can the Applicant establish a prima facie claim?
The Applicant’s policy is a comprehensive commercial motor policy. The policy
covers a number of vehicles and includes cover for a 2002 Northern Tri-axle Dog
Trailer (the trailer).
The policy provides insurance against theft and accidental loss and damage.
There is no dispute that the accident happened as described by the Applicant
when he was tipping the trailer.
According to the Applicant as he lifted the body of the trailer three quarters of the
way, the ground at the back tyre of the trailer on the left hand side collapsed. As
this happened, the chassis from the dolly axle (front axle) snapped and the
chassis cracked towards the back.
Accidental damage is said to be damage which is sudden, unintended and
unexpected. I am satisfied that the damage to the trailer being occasioned in the
manner described by the Applicant is sudden, unintended and unexpected. I am
satisfied the Applicant has established on the balance of probabilities that the
damage was accidental damage in accordance with the terms of the policy.
The onus is therefore on the FSP to establish the application of any relevant
exclusion.
2.2 Can the FSP establish the application of a general exclusion?
The FSP relies upon the general exclusions relating to wear and tear and/or faulty
design and/or workmanship in order to deny liability for the Applicant’s claim.
In relying upon the exclusions, the FSP has referred to reports obtained from IN
and MCS.
An assessment report provided by IN confirms the trailer sustained extensive
damage consistent with the accident description. IN deemed the trailer as a total
loss. The report concludes the trailer had sustained damage to the chassis due to
old cracks causing extra strain in the chassis.
Presumably, these cracks opened when the trailer was in the tipping motion and
the earth moved under the left and rear tyre.
A more detailed report was obtained from MCS. MCS is an engineering group.
MCS identified that there was extensive failure at the start of the cantilevered
Case No: 368604 Determination Page 3 of 5
section and that the damage was due to a combination of fatigue and sudden
fracture. When the fatigue area failed, it caused additional stress and sudden
fracture.
I note however that MCS concedes he was unable to determine if the welds
identified through the report were part of the original design or not. MCS
consulted with DZ another engineer. DZ indicated he had not seen this type of
failure before.
There are suggestions in the report that there were modifications to the trailer and
issues with the compliance plate although there is no proof of this.
MCS confirmed he would need to review the design drawings which were not
available. MCS advised that he cannot say if the trailer was lifting loads beyond its
design limit.
MCS considered that the force exerted on the cantilevered section overtime
resulted in the internal cracking followed by the extensive failure. It is unclear
whether MCS considered the cracking had occurred prior to the incidents on 3
December 2013 or occurred on that day resulting in the subsequent extensive
failure of the cantilevered section.
Significantly, MCS conceded that to accurately determine the type of failure and if
it was a fatigue failure required a metallurgist consideration. Whilst he thought the
rudimentary nature of construction contributed to the loss, it was extremely
difficult to determine the extent of such contribution without metallurgical tests
conducted on the failure zones including nearby welds and a complete set of
structural calculations.
The trailer was certified roadworthy on 17 June 2013, 6 months prior to the date
of the loss. At that stage, the fatigue cracks were not identified.
The evidence as presented is insufficient to establish that the trailer had been
subjected to excessive loads. There is no evidence that the trailer was not
maintained in accordance with the design specifications nor is there evidence
sufficient to establish that the failure was due to a structural or design fault or poor
workmanship.
The FSP’s enginee r has identified that in order to determine these issues, a
metallurgist report should have been obtained. No report has been obtained.
In the circumstances, I am not satisfied that the information as presented is
sufficient to establish on the balance of probabilities that the damage was due to
wear and tear, deterioration, rust or corrosion or faulty design and workmanship.
Pre-accident value
The policy insures the trailer for the sum of $35,000 or market value whichever is
lesser.
The report from the IN indicates the pre-accident value of the trailer was $31,500.
No evidence has been presented by the Applicant to dispute the pre-accident
value. In the circumstances, I am satisfied the FSP is entitled to cash settle the
claim based on the market value assessed at $31,500 less applicable excess of
$2,000.
Case No: 368604 Determination Page 4 of 5
3 Supporting information
3.1 Policy wording
The following exclusions are relevant to this claim:
“ Addi tional exclusions applying to all Sections of thi s Policy
This Policy does not cover:
…
2. loss of or damage to your vehicle due to depreciation, wear, tear, rust or corrosion
3. loss of or damage to your vehicle or any resultant mechanical damage:
(i) due to failure or breakdown of a structural, electrical, mechanical or electronic
nature, or …”
3.2 Expert evidence
Record Key points
FSP’s assessor ( IN )
Assessment Report
9 December 2013
“The vehicle has sustained extensive damage. All damage
appears consistent with accident description.”
“Trailer has sustained damages chassiss due to old cracks in
trailer (as images show) causing extra strain in chassiss
which caused it to brake on both sides in same spot.” (sic)
FSP’s engineer ( MC )
Report
22 January 2014
Failure of the chassis could be as a result of fatigue over a
period of time or a sudden fracture.
There i s evidence of both fatigue fractures and sudden
fractures.
There was evidence of failure at and next to welds on the
chassis.
It was not evident if the welds were part of the original
design or added later.
A representative of the company from which the Ap plicant
purchased the trailer (GE) indicated there was no evidence
to support any modifications to the vehicle having been
done by GE.
There was no modification plate fitted to the vehicle to
support any approved modifications having been
completed to the vehicle.
Loads carried by the truck over its life may have
contributed to the fatigue cracking evident.
A metallurgist would need to provide accurate details on
the type of failure and an indication of the number of
operating cycles if it was a fatigue failure.
MC’s opinion is, “… the dominant cause of the failure of
the trailer is most likely to have been loads carried
throughout its life being in excess of the SWL [Safe
Working Load]. However the rudimentary nature of the
construction and weld joints a round the point failure on the
trailer that I sighted on my inspection, in my opinion, may
well have contributed, and possibly significantly, to the
fatigue failure over time. Unfortunately the extent of that
contribution would be extremely difficult to de termine
Case No: 368604 Determination Page 5 of 5
unless metallurgical tests were conducted on the failure
zones including nearby welds and a complete set of
structural calculations undertaken.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.