Home / Financial Firm (Unknown - Insurer) / Determination 368604

Determination 368604

Trailer chassis failure denied under wear, tear and faulty design exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2015-02-26
ProductGeneral Insurance · Motor
OutcomeFor the complainant
Amount awarded$29,500
Non-financial loss—
Amount claimed$31,500
SourceAFCA PDF

Summary

A landscaping business claimed for a trailer chassis failure during tipping, and the FSP denied it under wear, tear and faulty design exclusions. AFCA found the FSP had not established the exclusions and ordered cash settlement of the $31,500 market value less a $2,000 excess, plus interest.

The insurer bears the onus of establishing an exclusion, and the evidence did not show that wear and tear, faulty design or workmanship caused the failure.

Issues

Subjects and remedies

pay claimpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Small Business/Farm Insurance - Commercial Vehicles - FSP Decision - Denial of Claim - Exclusion/Condition Determination Case No: 368604 Determination Page 1 of 5 Case number : 368604 18 December 2015 1 Overview 1.1 Dispute The Applicant, a landscaping business, lodged a claim under its commercial motor policy for damage sustained to a 2002 tri-axle dog trailer when the chassis failed during a tipping operation on or about 3 December 2013. The FSP has denied the Applicant’s claim on the basis that the loss is excluded under the policy. 1.2 Issue and key findings Can the Applicant establish a prima facie claim? The Applicant has established a prima facie claim because:  the policy provides comprehensive cover in the event of theft or accidental loss or damage  accidental loss or damage is damage which is sudden, unintended and unexpected  the chassis collapse was sudden, unintended and unexpected during a normal tipping operation. Can the FSP establish the application of a general exclusion? The FSP has not established the application of a general exclusion because:  the damage was sustained due to combination of fatigue fracture and sudden fracture  the evidence does not establish the fracture was due to faulty design or workmanship  the evidence does not establish the fracture was due to depreciation, wear and tear, rust or corrosion. 1.3 Determination This Determination is in favour of the Applicant. The FSP is to cash settle the Applicant’s claim for the market value of $31,500 plus interest pursuant to Section 57 of the Insurance Contracts Act 1984 (the Act) from 4 March 2014 to date of payment of the claim. Case No: 368604 Determination Page 2 of 5 2 Reasons for Determination There has been a full exchange of material between the parties and each party has had the opportunity of addressing the issues that arise from the material exchanged. This Determination is based on what is fair in all the circumstances, having regard to the material exchanged, relevant legal principles, terms of the policy, good industry practise and prior Determinations where applicable. 2.1 Can the Applicant establish a prima facie claim? The Applicant’s policy is a comprehensive commercial motor policy. The policy covers a number of vehicles and includes cover for a 2002 Northern Tri-axle Dog Trailer (the trailer). The policy provides insurance against theft and accidental loss and damage. There is no dispute that the accident happened as described by the Applicant when he was tipping the trailer. According to the Applicant as he lifted the body of the trailer three quarters of the way, the ground at the back tyre of the trailer on the left hand side collapsed. As this happened, the chassis from the dolly axle (front axle) snapped and the chassis cracked towards the back. Accidental damage is said to be damage which is sudden, unintended and unexpected. I am satisfied that the damage to the trailer being occasioned in the manner described by the Applicant is sudden, unintended and unexpected. I am satisfied the Applicant has established on the balance of probabilities that the damage was accidental damage in accordance with the terms of the policy. The onus is therefore on the FSP to establish the application of any relevant exclusion. 2.2 Can the FSP establish the application of a general exclusion? The FSP relies upon the general exclusions relating to wear and tear and/or faulty design and/or workmanship in order to deny liability for the Applicant’s claim. In relying upon the exclusions, the FSP has referred to reports obtained from IN and MCS. An assessment report provided by IN confirms the trailer sustained extensive damage consistent with the accident description. IN deemed the trailer as a total loss. The report concludes the trailer had sustained damage to the chassis due to old cracks causing extra strain in the chassis. Presumably, these cracks opened when the trailer was in the tipping motion and the earth moved under the left and rear tyre. A more detailed report was obtained from MCS. MCS is an engineering group. MCS identified that there was extensive failure at the start of the cantilevered Case No: 368604 Determination Page 3 of 5 section and that the damage was due to a combination of fatigue and sudden fracture. When the fatigue area failed, it caused additional stress and sudden fracture. I note however that MCS concedes he was unable to determine if the welds identified through the report were part of the original design or not. MCS consulted with DZ another engineer. DZ indicated he had not seen this type of failure before. There are suggestions in the report that there were modifications to the trailer and issues with the compliance plate although there is no proof of this. MCS confirmed he would need to review the design drawings which were not available. MCS advised that he cannot say if the trailer was lifting loads beyond its design limit. MCS considered that the force exerted on the cantilevered section overtime resulted in the internal cracking followed by the extensive failure. It is unclear whether MCS considered the cracking had occurred prior to the incidents on 3 December 2013 or occurred on that day resulting in the subsequent extensive failure of the cantilevered section. Significantly, MCS conceded that to accurately determine the type of failure and if it was a fatigue failure required a metallurgist consideration. Whilst he thought the rudimentary nature of construction contributed to the loss, it was extremely difficult to determine the extent of such contribution without metallurgical tests conducted on the failure zones including nearby welds and a complete set of structural calculations. The trailer was certified roadworthy on 17 June 2013, 6 months prior to the date of the loss. At that stage, the fatigue cracks were not identified. The evidence as presented is insufficient to establish that the trailer had been subjected to excessive loads. There is no evidence that the trailer was not maintained in accordance with the design specifications nor is there evidence sufficient to establish that the failure was due to a structural or design fault or poor workmanship. The FSP’s enginee r has identified that in order to determine these issues, a metallurgist report should have been obtained. No report has been obtained. In the circumstances, I am not satisfied that the information as presented is sufficient to establish on the balance of probabilities that the damage was due to wear and tear, deterioration, rust or corrosion or faulty design and workmanship. Pre-accident value The policy insures the trailer for the sum of $35,000 or market value whichever is lesser. The report from the IN indicates the pre-accident value of the trailer was $31,500. No evidence has been presented by the Applicant to dispute the pre-accident value. In the circumstances, I am satisfied the FSP is entitled to cash settle the claim based on the market value assessed at $31,500 less applicable excess of $2,000. Case No: 368604 Determination Page 4 of 5 3 Supporting information 3.1 Policy wording The following exclusions are relevant to this claim: “ Addi tional exclusions applying to all Sections of thi s Policy This Policy does not cover: … 2. loss of or damage to your vehicle due to depreciation, wear, tear, rust or corrosion 3. loss of or damage to your vehicle or any resultant mechanical damage: (i) due to failure or breakdown of a structural, electrical, mechanical or electronic nature, or …” 3.2 Expert evidence Record Key points FSP’s assessor ( IN ) Assessment Report 9 December 2013 “The vehicle has sustained extensive damage. All damage appears consistent with accident description.” “Trailer has sustained damages chassiss due to old cracks in trailer (as images show) causing extra strain in chassiss which caused it to brake on both sides in same spot.” (sic) FSP’s engineer ( MC ) Report 22 January 2014  Failure of the chassis could be as a result of fatigue over a period of time or a sudden fracture.  There i s evidence of both fatigue fractures and sudden fractures.  There was evidence of failure at and next to welds on the chassis.  It was not evident if the welds were part of the original design or added later.  A representative of the company from which the Ap plicant purchased the trailer (GE) indicated there was no evidence to support any modifications to the vehicle having been done by GE.  There was no modification plate fitted to the vehicle to support any approved modifications having been completed to the vehicle.  Loads carried by the truck over its life may have contributed to the fatigue cracking evident.  A metallurgist would need to provide accurate details on the type of failure and an indication of the number of operating cycles if it was a fatigue failure.  MC’s opinion is, “… the dominant cause of the failure of the trailer is most likely to have been loads carried throughout its life being in excess of the SWL [Safe Working Load]. However the rudimentary nature of the construction and weld joints a round the point failure on the trailer that I sighted on my inspection, in my opinion, may well have contributed, and possibly significantly, to the fatigue failure over time. Unfortunately the extent of that contribution would be extremely difficult to de termine Case No: 368604 Determination Page 5 of 5 unless metallurgical tests were conducted on the failure zones including nearby welds and a complete set of structural calculations undertaken.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.