Determination 367625
Claim for fuel injection pump damage declined under mechanical failure exclusion; expert report costs and interest sought
Summary
The insured's comprehensive claim for fuel injection pump damage was declined as mechanical failure. AFCA found the FSP had not established the exclusion, ordered the claim paid under the policy with statutory interest on cash settlement, and ordered reimbursement of expert report costs up to $3,000.
The insurer bears the onus of establishing an exclusion, and its expert evidence did not establish that the damage fell within the mechanical or other failure exclusion.
Issues
- Claim denial primary · upheld
“The FSP has not established, on the balance of probabilities, the cause of the damage falls within a policy exclusion.”
- Poor claim handling secondary · not upheld
“The FSP has not mishandled the claim or acted inappropriately in anyway which might warrant such compensation.”
Subjects and remedies
pay claimpay compensationpay interest
Text of the determination
Determination
General Insurance - Domestic Insurance - Motor Vehicle- Comprehensive - FSP
Decision - Denial of claim-Exclusion/ condition
Case number : 367625 2 8 January 2015
Case No: 367625 Determination Page 2 of 8
1 Overview
1.1 Dispute
The Applicant holds a comprehensive motor vehicle policy (the policy) with the
Financial Services Provider (FSP) incepted on 29 June 2009 and renewed
annually.
On 3 March 2014, the Applicant lodged a claim for damage to the fuel injection
pump of his vehicle, describing the cause of the damage as fuel contamination.
However, the FSP declined the claim on the basis the damage was instead
caused by the excluded event mechanical or other failure.
The Applicant disputes the denial of the claim and also seeks compensation for
stress and inconvenience caused by being without the vehicle.
1.2 Issues and key findings
Is the damage covered under the policy?
The FSP is liable for the damage because:
The Applicant has a prima facie claim under the policy for accidental damage
The FSP has not established, on the balance of probabilities, the cause of the
damage falls within a policy exclusion
Is the FSP required to pay compensation to the Applicant?
The FSP is required to reimburse the Applicant for the costs incurred in obtaining
expert reports.
1.3 Determination
This Determination is in favour of Applicant.
The FSP is to meet the Applicant‟s claim in accordance with the terms and
conditions of the policy.
If the FSP elects to cash settle the claim, it is required to pay interest on the
settlement amount from the date of the Internal Disputes Resolution decision, 6
June 2014, until the date of payment at the statutory rate.
Upon the Applicant providing invoices for costs incurred in obtaining his own
expert reports, the FSP is to reimburse the Applicant for these costs to a
maximum of $3,000.
Case No: 367625 Determination Page 3 of 8
2 Reasons for Determination
I have decided this case on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous Financial Ombudsman Service
(FOS) decisions. I have taken into account all the material submitted by the
parties. There has been a full exchange of all documents relied on to make this
Determination and each party has had the opportunity to address any issues
raised by the other.
This dispute has not been the subject of a FOS Recommendation. Due to its
nature, it was appropriate to proceed directly to a Determination in line with the
Operational Guidelines to the FOS Terms of Reference.
There are conflicting expert opinions expressed by the mechanical engineers MA
and ET as to the cause of the damage to the vehicle, which I have considered in
determining the proximate cause of the damage to the vehicle.
It is also noted that MA does not disagree with the extent of the damage and
where it occurred as discovered by ET‟s inspection. Instead, ET and MA disagree
as to why this damage has occurred.
2.1 Is the damage covered under the policy?
The Applicant has established a prima facie claim
The Applicant‟s policy provides cover for accidental damage to his vehicle,
subject to the conditions and exclusions set out in the policy. This includes a
general exclusion for mechanical, structural, electrical, electronic or other failure
or breakdown.
As “accidental” is not defined in the policy, a plain English definition is applicable.
The Macquarie Dictionary says “accidental” means “happening by chance or
accident, or unexpectedly”.
There is no dispute the failure of the fuel injection pump was unexpected and
sudden. Accordingly, the Applicant has established a prima facie claim under the
policy.
The Applicant provided evidence the damage was caused by fuel
contamination
The Applicant, in establishing a prima facie claim, does not have to establish the
exact cause of the damage, but he did provide reports and/or emails from
mechanical engineer MA, Porsche (the car manufacturer) and Bosche (the engine
manufacturer) which opine that the cause of damage was due to contaminated
fuel. These opinions were formed after a visual inspection of the subject damaged
fuel injection pump.
A fuel sample was analysed by Intertek and was found to contain no free water or
a flammable material.
Case No: 367625 Determination Page 4 of 8
However, MA and Porsche have both confirmed the damage is consistent with
other cases of fuel contamination and have explained that a small amount of
contaminated fuel, despite having been subsequently flushed out by refuelling,
could have initiated the failure.
The FPS’s report on the cause of damage is not persuasive
The FSP sought a report from another mechanical engineer ET on the cause of
the damage. ET conducted a microscopic inspection of the damaged areas of the
fuel injection pump. ET‟s report found that the damage had occurred due to a high
force input on one cam lobe by one of the roller followers. This caused a chain of
events which resulted in the failure of the fuel injection pump.
ET‟s re port says there is no evidence to support the view that fuel contamination
was the proximate cause of failure. However, it does not conclude how the high
force input, which he states initiated the damage, occurred. The report instead
offers five possible causes. The FSP says that all of these possible causes could
be considered mechanical or other failure or breakdown but does not actually
establish the cause of damage.
T he Applicant‟s reports had indicated that even a small degree of fuel
contamination in a diesel engine may affect the lubricity of the fuel on the lobes,
thus causing the damage. The conclusion drawn b y ET that the evidence cannot
support the damage being caused in this way seems to be directly contradicted by
his suggestions of how the damage occurred.
ET offers a number of suggestions, two of which, although he considers these
less likely, relate to damage being caused by lack of lubricity of the fuel on the
lobes. Moreover, one of these possibilities also refers to the damage being
caused by contaminated fuel entering the pump .
MA provided a response to ET‟s report which outlines why each of the pos sible
causes of damage suggested by ET are not viable. MA‟s reasoning in this
response is persuasive. The subsequent response from ET is based on the
incorrect assumption that MA has not inspected the damaged fuel injection pump
and does not provide any further evidence that the damage was caused by
mechanical or other failure.
The FSP has not established the damage falls within an policy exclusion
As the FSP is seeking to rely on a policy exclusion or condition to deny the
Applicant‟s claim, it bea rs the onus of establishing, on the balance of probabilities,
the relevant exclusion or condition applies.
ET was not able to establish the actual cause of damage, although he suggested
a number of possibilities which might be considered to fall within the exclusion.
Further, his analysis of whether the failure of the pump may have been caused by
fuel contamination is contradictory. This is not sufficient for the FSP to satisfy its
onus to establish the damage to the fuel injection pump was caused by
mechanical or other failure or breakdown.
Case No: 367625 Determination Page 5 of 8
2.2 Is the FSP required to pay compensation to the Applicant?
The FSP is required to reimburse the Applicant for consequential financial
loss
Under paragraph 9.3(a) of the Terms of Reference (TOR), FOS may award
compensation for consequential financial loss up to a maximum of $3,000.
The Applicant may have incurred expense in ob taining reports from various
experts. As these reports provided key information, if the Applicant can produce
invoices for these expenses, the FSP is to reimburse the Applicant for those
invoices up to the limit of $3,000.
The FSP is not required to pay non-financial loss to the Applicant
Whilst paragraph 9.3(b) of the TOR allow FOS to award compensation for non-
financial loss (capped at $3,000), FOS expects an applicant to be moderately
robust and bear the ordinary and normal degree of inconvenience associated with
correcting an unexpected problem.
Whilst it was inconvenient for the Applicant to be without his car for a long period
of time, the FSP has not mishandled the claim or acted inappropriately in anyway
which might warrant such compensation.
Case No: 367625 Determination Page 6 of 8
3 Supporting information
3.1 Expert reports
Re cord Key points
Email from Porsche Melbourne
1 March 2014
Failure of the components in the fuel system is due to
fuel contamination (no reasons given for this
conclusion)
Intertek Report
31 March 2014
The diesel sample is not contaminated with free water
or a flammable material
Email from S D
Bosch Service Engineer
1 6 April 2014
C onsidered photos submitted and physically
inspected the subject pump on 12 April 2014
Failure is due to lack of lubrication resulting fr om
use of contaminated and/or poor quality fuel
Report from MA
5 May 2014
The pump had failed due to severe wear on the
pump cam lobes and particularly on the mating
roller followers which drive the pump plungers
The metal surfaces had suffered considerab le
scuffing and galling, rendering the operation of the
pump insufficient to run the engine
This is a classic case of lubrication failure between
contacting metal surfaces.
This failure mode commences at a microscopic
level but once begun, will inevitably progress.
T he lubrication failure must certainly be due to the
quality of the lubricant.
The fuel used in this vehicle, at some stage of its
operation, must have been contaminated.
Contaminated fuel, once introduced to the pump,
would initiate the failure mode.
A short exposure to the contaminated fuel would be
enough to initiate the failure mode but a substantial
refill with normal fuel could extend the period of
time before total pump failure.
Conclusion that fuel contamination has caused
failure of the p ump
Report from ET
29 May 2014
Inspected, in detail and by magnification, the
principle wear areas which could be affected by
contaminated fuel.
Where the lubricity of the diesel has been affected
by contaminated fuel, t he effect would be most
notable on the plungers of the two delivery heads
A magnified inspection revealed some microscopic
abrasion traces consistent with the usage and age
of the fuel pump.
Inspection of the dual lobe cam shaft and, in
particular, one of the lo b es revealed that a high
Case No: 367625 Determination Page 7 of 8
Re cord Key points
im pact event occurred on that lobe across the full
width of the roller which caused spalling of the
surface and the release of abrasive metallic
particles. The opposing lobe did not show this.
The release of these particles caused the roller
sleeves to rotat e resulting in the high abrasive
effect which caused a central wear groove to be
gouged into the lobes of the cam shaft.
The rollers themselves showed material
impressions over the majority of their
circumference identifying the fact they were still
turnin g whilst the damage was occurring.
The final abrasive damage to the rollers resulted in
a deep gouge mark in the surface which clearly
released further particles.
Other damage confirms this sequence of events
The evidence indicates the probability of a fue l
contamination cannot be sustained and it is clear
th e failure of this pump occurred due to a sudden
high force overload on one of the two cam lobes.
The possible causes in order of probability are:
o Faulty electronic control module on the
pump control valve
o An engine over speed event
o High engine speed with cold fuel
o A failure in the filter allowing a slug of
contaminated fuel to enter the pump
o Air entering the pump and destroying
lubricity of the fuel on one of the lobes
Report from Porsche
18 June 201 4
During diagnosis, confirmed there was inadequate
fuel pressure. Further diagnosis revealed evidence
of metallic particles in the fuel filter. This was the
result of the fuel pump failing.
T his is consistent to similar cases whereby the car
has been misfu elled with petrol. This causes
insufficient lubricant and subsequently creates
excess friction in the fuel pump which results in
metallic particles throughout the fuel system.
Whilst there was no evidence of petrol at the time
of failure, it is common that if a small quantity of
petrol mixed with diesel is incorrectly filled then the
failure is not likely to occur instantly, it will slowly
starve the necessary moving components of
lubrication and subsequently fail in the future.
Second report from MA
30 Ju ne 2014
Includes a response to conclusions reached by ET
Whilst ET considers mode of failure to be physical
overload, MA (and Porsche, Bosch and C (verbally
only)) concluded lubrication to be the cause of the
failure
Case No: 367625 Determination Page 8 of 8
Re cord Key points
MA addresses each of the 5 possible c auses of
fa ilure proposed by ET and why the damage was
not caused in these ways
MA notes that two possible causes of the failure put
forward by ET are consistent with his own
argument that fuel contamination caused a
lubrication failure
Email from Porsch e
15 July 2014
We can categorically state that in our experience of
numerous cases of the failure of the fuel pump, to
date we are yet to see one that was not a result of
mis - fuelling or fuel contamination
Email from ET
19 August 2014
It appears MA has pr ovided an opinion on ET‟s
report without seeing the „offending‟ pump and has
relied solely in Internet details of failures of this
pump model
MA‟s response of 30 June 2014 forces the
conclusion that the pump had a reliability flaw
MA has not established th e fuel was contaminated
If the fuel was contaminated sometime in the past,
the effect would without doubt have been
immediate failure
The high spalling failure and effect on one cam
lobe is not visible on the other lobe and this can
only have been caused by a high sudden impact
MA‟s arguments regarding the forces acting on the
cam lobes are confusing
Based on MA‟s research, this pump appears to
have reliability problems.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.