Home / Financial Firm (Unknown - Insurer) / Determination 367407
Determination 367407
Windstorm damage to building denied for wear and tear, latent defect and maintenance exclusions
Summary
The strata insurer denied external windstorm damage to the building as deterioration, latent defect and lack of maintenance. AFCA decided in favour of the complainant, ordering payment of reasonable repair costs with interest from the date of repair.
The insurer bore the onus of proving an exclusion applied and did not establish that wear and tear, latent defect or lack of maintenance was the proximate cause of the storm damage.
Issues
- Claim denial primary · upheld
“The FSP has not established, on the balance of probabilities, that the tie down strap suffered from wear and tear as opposed to loosening during the windstorm.”
- Product terms interpretation secondary · upheld
“There is no evidence that the original tie down strap was faulty. It is not excluded under the policy.”
Subjects and remedies
home or building damagenatural disasterpay claimpay interest
Text of the determination
Determination
General Insurance - Domestic Insurance - Residential Strata Title - FSP Decision -
Denial of claim-Exclusion/ condition
General Insurance - Domestic Insurance - Residential Strata Title - Service - Service
quality
Determination
Case No: 367407 Determination Page 1 of 8
Case number : 367407 3 December 2014
1 Overview
1.1 Dispute
In October 2013 the Applicant lodged a claim under a Residential Strata
Insurance Plan underwritten by the Financial Services Provider (FSP) for damage
to the building due to high winds.
The FSP denied the claim for external damage of the building on the basis the
damage was caused by gradual deterioration, developing flaws and latent defects
all of which are excluded by the policy. The FSP accepted liability for internal
damage to one unit.
1.2 Issues and key findings
Is the FSP entitled to deny the claim?
The policy provides cover for accidental loss or damage to the insured property.
The proximate cause of the damage was high winds and a loosened tie down
strap that permitted the corner of the apartment complex‟s roof to temporarily lift.
The FSP has not established that the loosened tie down strap was a cause
excluded by the policy.
The FSP is not entitled to deny the claim.
1.3 Determination
This Determination is in favour of the Applicant.
The FSP must pay to the Applicant:
the reasonable cost of the repairs for damage to the building in accordance
with the terms and conditions of the policy, and
interest on the reasonable cost of those repairs at the rate prescribed by the
Insurance Contracts Act from 23 September 2014 (when the Applicant
undertook the repairs) until payment is made.
Case No: 367407 Determination Page 2 of 8
2 Reasons for Determination
I have decided this case on its merits, doing what is fair in all the circumstances
having regard to the relevant law, good industry practice, codes of practice and
previous FOS decisions. I have taken into account all the material submitted by
the parties. I am satisfied that the documentation I have relied on has been
provided to both parties.
This dispute has been expedited to a Determination. No Recommendation was
issued.
2.1 Is the FSP entitled to deny the claim?
The FSP has the onus of establishing the claim is excluded under the policy
The policy provides cover for accidental loss or damage to the insured property.
The building was damaged during a period of high winds. The damage is covered
by the policy unless the FSP can establish that the claim is excluded under the
policy.
The cause of the damage was a loosened or detached hold down strap
After considering reports by the FSP‟s loss adjuster (PI), the FSP‟s engineer (JM)
and the Applicant‟s engineer (FG) I consider the most reliable report is the
updated report of FG. This is because:
FG examined the roof space by lifting the roof sheets (which JM did not) and
also through inspection holes in the ceiling of the below unit.
JM made a number of incorrect assumptions relating to previous damage to
the building to demonstrate the inherent nature of the defect. For example:
o JM referred to previous patched inspection holes in the ceiling without
adequate rectification works. However a comparison of the photos taken by
FG and JM reveals these inspection points were the ones opened by FG.
o JM referred to inadequate repairs by referring to FG‟s photo of screws
placed into the top of the roof. These were temporary repairs authorised by
the Applicant after the windstorm.
FG found that the windstorm contributed to the damage to the roof, by uplifting of
the particular corner of the roof where a loosened or detached tie down strap
existed. The Applicant submits this was due to a failure of the nail that held the tie
down strap, although this is not mentioned in FG‟s report.
I accept FG‟s findings and conclude that the cause of the damage was the wind
and a loosened or detached hold down strap.
The FSP seeks to rely on policy exclusions and the Wayne Tank principle
The FSP denies the claim on the basis that the proximate or dominant cause of
the damage are causes excluded under the policy, namely:
latent defects and inherent vice
gradual deterioration and developing flaws, and
Case No: 367407 Determination Page 3 of 8
lack of maintenance.
The policy exclusions are set out in section 3.1 below.
The FSP submits that if there are two causes of damage, the wind and one that is
excluded under the policy (such as late nt defects), then the claim should be
denied. This is because of the operation of the “Wayne Tank” principle. This
principle of law states that where there are two or more concurrent causes of the
loss or damage and one of these causes is excluded from cover, then an insurer
is not legally liable for the loss and the claim may be excluded in its entirety.
The FSP has not explained the basis on which it accepted the claim in respect to
the internal damage to the unit affected by the windstorm, while it has excluded
the balance of the claim.
Policy exclusions relating to latent defects and inherent vice do not apply
I do not accept that there was a latent defect or inherent vice in the construction of
the roof that is the proximate cause of the damage.
I acc ept FG‟s statement that the roof complied with building standards at the time
it was constructed, even if it does not comply with current standards. While
AS/NZS 1170.2 requires a roof to be able to withstand wind gusts 30% greater
than those that occurred on 30 September 2013, I note:
FG stated there are a number of variables at play such as wind direction,
height of structure, roof pitch and shape, terrain and topographic features in
determining the actual wind gust experienced by a building.
JM notes the exposed terrain near the corner of the damaged building, which
is four storeys high.
It was therefore not possible to determine the wind gust experienced by the
building on 30 September 2013.
The first edition of AS/NZS 1170.2 was in 1989, well after the building was
constructed and the most recent version was published in 2011.
The loosened tie strap was not a latent defect or inherent vice. No other tie straps
were noted to have suffered a similar fate.
The FSP has not established that the wear and tear exclusion applies
The FSP submits that, given the age of the building the loosened tie strap had
occurred due to wear and tear and gradual deterioration.
Neither expert was able to state whether the hold down strap was already
loosened or detached before the wind storm or whether the wind storm caused
the tie down strap to detach. FG uses language to suggest either scenario stating:
“the tie down strap (or hoop iron) has now been loosened and detached”
“The area of concern has occurred due to loosening of tie down strap”, and
“Uplift is caused by the ineffectiveness of the loosened / detached tie down
strap”.
If there was evidence that the tie down strap had become loose over time, I would
accept that wear and tear had caused this to occur and the exclusion would apply.
Case No: 367407 Determination Page 4 of 8
However, the onus of proof rests with the FSP to establish that an exclusion
applies. The FSP has not established, on the balance of probabilities, that the tie
down strap suffered from wear and tear as opposed to loosening during the
windstorm.
The FSP has therefore not established that the exclusion applies.
The policy exclusion for lack of maintenance does not apply
FG noted that it would not have been feasible or practical to have maintained or
inspected the connection that loosened and ultimately failed in the windstorm.
The FSP states it would be reasonable to expect that the integrity of the roof
would be regularly checked.
I do not accept that the failure on the part of the Applicant to have detected the
issue with the tie down strap to constitute a lack of maintenance. It was not
something that was immediately apparent or would be part of any routine
maintenance.
Further, it is not clear to me from the various reports provided, exactly what
previous damage or repairs, if any, had occurred in respect of the roof.
The FSP is therefore not entitled to deny the claim.
The claim must be settled
The FSP placed the Applicant on notice that he was required to take reasonable
steps to reduce loss or damage.
Having established the cause of the damage once the roof was lifted, the
Applicant rectified the damage to the roof in accordance with the
recommendations of FG. FOS was informed of this on 23 September 2014. The
Applicant then proceeded to repair the remaining damage.
The FSP states it is not required to pay for ensuring the roof is complaint with
today‟s standards and designs , as this would be excluded by virtue of exclusion
2(b) of the policy.
Exclusion 2b) states the FSP will not pay for:
“the cost of rectifying faulty or defective materials or faulty or defective workmanship”.
FG‟s recommendation related to the replacement of the loosened tie down strap.
There is no evidence that the original tie down strap was faulty. It is not excluded
under the policy.
In the circumstances, it was reasonable for the Applicant to proceed with the
repairs. The FSP must pay the Applicant the reasonable costs of those repairs.
Case No: 367407 Determination Page 5 of 8
3 Supporting information
3.1 Relevant policy terms
“ 1. We will not pay for loss or damage: (pages 25 and 26)
a. ...
b. …
c caused by ... lack of maintenance, ...gradual deterioration,... developing flaws,… or
failure to maintain Your Insured Property in a reasonably good state of repair
...
j. caused by inherent vice, latent defect...
However, we Will pay if any of these caus es directly result in loss or damage from any
other Event claimable under Policy 1 such as fire or glass breakage
...
m. due to normal settling, creeping, heaving, seepage, shrinkage, or expansion in
buildings, foundations / footings, walls bridges, roadways, kerbing, driveways, paths,
garden borders and other structural improvements.”
2. We will not pay for: (page 27)
...
b the cost of rectifying faulty or defective materials or faulty or defective
workmanship...”
Claims information (page 16)
“ 1. What you must do
As soon as You discover than Event likely to result in a claim has occurred, You must:
a. Take all reasonable steps to reduce the loss or damage and to prevent any further
loss or damage .”
3.2 Chronology and expert reports
Record Key points
30 September 2013 Maximum wind gust recorded was 96km/h at 11:57pm.
High winds affect insure d property.
Roof structure at the corner of unit 21 had lifted.
4 October 2013 Applicant lodges a claim with the FSP noting damage
was “Roof truss broken f ree from wall / timber framing
d ue to high winds”
31 October 2013
FSP‟s loss adjuster (PI)
Roof structure ties were insufficient and defective.
Damage consisted of cracking to the interior of unit 21 in
the kitchen and meals area.
12 November 2013 FSP declined cover for the roof structure on the basis of
Case No: 367407 Determination Page 6 of 8
Record Key points
policy exclusions relating to gradual deterioration,
developing flaws, latent defect and the cost of rectifying
faulty or defective materials or workmanship.
The FSP referred to the require ment that, once an Event
likely to result in a claim has occurred, the insured must
take all reasonable steps to reduce loss or damage .
I n the event the delay in the re p airs resulted in additional
or inflated loss, a claim for this additio nal loss may be
viewed with prejudice or refused.
FSP accepted the internal damage in the amount of
$2,880. No basis was provided.
17 January 2014
Applicant‟s expert (FG)
(sub sequently amended
on 24 September 2014)
FG states:
The 30 September 2013 wind storm had contributed to
the observed roof corner damage .
Winds were 96km/h sufficient to be classified as a
„storm‟.
This gust is approximately 30% less than the ultimate
wind speed required by the design proce s s for the
structure (AS/NZS 1170.2)
However, there are a number of variable s in play such
that it cannot be determined the actual wind gust
experienced by the building.
The construction would have met the design criter ia at
the t i me of construction, but does not comply with
current standards.
The tie down steel strip at the end rafter was loosened
due to the recent or past wind events.
No tie down connection to the top plate was present
near the first internal ra f ter h ence the top plate was
connected to the wall with skew nails.
No bracket connection was at the end rafter to top plate
connection.
FG was unable to determine the strength capacity of the
tie down connection or the bracket connection.
The damage occurred du e to loosening of a tie down
strap resulting in uplift of the roof framing , when the roof
was subject to large uplift suction pressure during the
recent wind event
FG was unable to determine whether the strap had
already been loose ne d prior to the recent wind event (ie
from past wind events).
No damage was reported or observed i n other areas
indicating that the areas of concern had been damaged
due to the ineffectiveness of the tie down strap.
Obvious previous repair work on the roof corners
sugg ests that the roof cladding had not been adequately
fixed to the roof framing.
The proximate cause of the damage is the
ineffectiveness of the structural tie down strap that does
Case No: 367407 Determination Page 7 of 8
Record Key points
not have adequate strength capacity to comply with the
current design standard.
The roof framing tie - down configuration is consistent
with expected construction methods at the time of the
original construction of the building.
31 January 2014
PI supplementary report
PI states:
Whilst it is speculated that the roof ties happened to fail
during the subject storm/ tempest conditions, if it was not
for the inade quate/ compromised roof tie dow n s , the
wind would not have had the effect it did.
FG states on multiple occasions that the loosening of
and failure of the roof ties can not be attributed to
particular past or present wind event/s; but rather
vibration and move ment over a period of time.
FG‟s findings ind ependently testify to the accuracy of the
scenario established by PI .
The proximate cause is inherent/ developing flaws, latent
defects, inadequate maintenance, vibration / movement
over a period of time, gradual deterioration,
faulty/defective roof etc.
14 April 2014
FSP‟s expert (JM)
JM states:
The roof structure ancho rage had been defective since it
was originally constructed.
Alth ough the rafter to top plate connect ors have not
failed, the anchorage between the top plate and the brick
walls has always been defective.
It is unlikely that there have been any tie downs for the
top plat e onto the wall and skew nails could not be fixed
into brickwork.
There has been at least one previous incident over the
50 year life of the building where the entire rood
struct u re ( including unit 21 ) ceiling plaster has lifted f r om
the wa ll and n ever been correctly reinstated.
A misalignment of a piece of cornice reflects an inability
to correctly return the roof structure back to the
supporting wall top plate after a similar failure.
FM agrees tha t the wind velocity was approximately 30 %
below the st i pu l ated wind design velocity in accordance
with the Code .
The roof sheets on the bu i l d i ngs are in very poor
condition, substantially corroded and need to be
replaced. Presumably, spouting and downpipes may
also ne e d to be replaced, not ing the 50 year age of the
building.
R o of sheet separation from the battens above Unit 2 1
has also been an old problem. Rather than add ress the
problem correctly, screws have merely been fixed
Case No: 367407 Determination Page 8 of 8
Record Key points
through the roof sheets and through the battens onto the
roof raft ers.
Notes the patched inspection openings by others without
any significant roof structure anchorage modification.
5 June 2014 FSP provided its final decline of the claim
3 Sept e mber 2014
Applicant‟s submission to
FOS
JM‟s reference to signs of previou s inadequate repair
was the temporary repair necessary to reaffix the loose
sheets.
Neither PI nor JM had lifted any roof sheets to examine
whether a latent defect exists, and if it does, whether it is
the sole or contributing factor to the claim.
10 September 2014
Applicant submission to
FOS
FG again inspected the building, this time lifting up the roof
sheeting to gain access. This inspection revealed:
The area had tie down straps which were sufficient as
installed originally .
The strap in question had loosened considerabl y .
Cause of the loosening was due to nails having come
out.
Corrosion was not relevant .
Nails were and remain an accepted means of securing
tie down straps under normal circumstances.
23 September 2014
Applicant‟s expert FG
Updated report (that
replaces previous FG
report)
FG lifted the roof sheets and states:
T he visual evidence suggests the rafter including the top
plate and adjacent batten lifted as a result of the wind
uplift causing the internal damage .
The wind uplift in the area of concern has occurred due
to loosening of the tie down strap, when the roof was
subjected to large upward suction pressure during the
subject windstorm event.
The area of concern has been damag ed due to the
ineffectiveness of the tie down s trap.
It would not have been feasible or practical to have
ma intained or inspected this connection.
The windstorm has contributed to the observed roof
corner damage, by uplifting the particular corner of the
roo f where a loosened or detached hold down st rap
existed.