Concrete driveway and fuel line damage claim declined as settlement or gradual deterioration

FirmFinancial Firm (Unknown - Insurer)
Decided2015-01-28
ProductGeneral Insurance · Pet
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

A petrol station company claimed for damage to its concrete driveway and underground fuel lines, attributing it to a heavy vehicle load. The FSP declined on the basis of settlement and gradual deterioration exclusions. AFCA found the damage was more likely caused by long-term settlement from moisture ingress, which is excluded.

Settlement caused by stormwater seepage does not fall within the policy exceptions, and the evidence favoured long-term settlement over a single heavy-vehicle impact.

Issues

Subjects and remedies

home or building damagesmall businessno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Small Business/Farm Insurance - Commercial Property - FSP Decision - Denial of Claim - Exclusion/Condition Determination Case No: 366458 Determination Page 1 of 10 Case number : 366458 27 January 2015 1 Overview 1.1 Dispute The Applicant ‟s company (insured), claimed for the cost of repairing damage to its property (a petrol station), submitting that the damage was caused by loads imposed on the property‟s concrete driveway by a heavy vehicle. The Financial Service Provider (FSP) declined the claim on the basis the damage was caused by subsidence, settlement and long term gradual deterioration, which were excluded events. 1.2 Issue and key findings Can FSP refuse the claim? The FSP can refuse the claim because the available evidence is more consistent with a view that the damage to insured‟s property was caused by settlement, which is an excluded event. 1.3 Determination This Determination is in favour of the FSP. The FSP is not required to indemnify the insured for the damage to its property. Case No: 366458 Determination Page 2 of 10 2 Reasons for Determination 2.1 Can FSP refuse the claim? FSP has to prove an exclusion to decline the claim The policy provides coverage for accidental damage occurring at the property, during the period of insurance. There is no dispute:  a number of underground fuel lines at the property failed pressure tests on 8 August 2012 and were apparently leaking  their repair necessitated the removal and replacement of a section of the property‟s concrete driveway. There is no evidence the insured expected or intended the damage to its property. This means the insured would be entitled to indemnity for the damage unless the FSP proves the claim is not covered or is otherwise excluded. Engineer “CG” suggest damage cause by load imposed by heavy vehicle The insured believes the fuel lines were damaged by loading imposed by a heavy vehicle at corners of the concrete driveway, which meet a gatic cover. It relies on engineer “CG”, who essentially explained the sequence of events as follows:  a heavy vehicle likely cracked the corners of the concrete driveway sometime between 30 July and 12 August 2012  stormwater naturally drains towards the gatic cover area as it was located at the low section of the driveway (relative to the rest of the property)  stormwater had seeped under the concrete slab and undermined the sub- base through the cracks  this led to settlement of the service pit, causing further failure of the concrete slab and likely damaged the fuel lines as well. CG initially believed that the damage was caused by settlement, explaining that:  there was substantial moisture beneath the concrete slab  this undermined and caused the sub grade to fail, possibly creating a void under the slab  continued traffic loads over the area caused the concrete to fracture and fail, possibly damaging the fuel lines as well. CG says his initial opinion should be discounted because:  he inspected the area after it was excavated and discovered that the ground water table was at least 3.0m below the finished surface level  the crack in the concrete was “clean” and as such, did not appear consistent with a crack arising from “fatigue failure”. Other engineers say damage caused by settlement The FSP maintains there is no evidence the fuel lines were damaged by loads imposed by a heavy vehicle. It relies on other expert evidence which say the damage was caused by long term settlement of the fill material above the underground tanks. Case No: 366458 Determination Page 3 of 10 This line of evidence explains the sequence of events as follows:  rainwater had seeped under the concrete slab through unsealed joints in the concrete driveway  rainwater softened and undermined the sub-base material  repeated vehicle loads then caused further settlement and the development of the cracks in the concrete. Settlement or earth movement damage is excluded unless an exception applies The policy essentially excludes damage caused by any form of settlement or earth movement, unless such settlement or earth movement was a direct consequence of:  an earthquake  a subterranean fire  a volcanic eruption  water escaping from a water main owned by a water supply authority. Although there are conflicting explanations as to how the damage to fuel lines and concrete driveway could have occurred, it is common ground:  there is settlement of the concrete driveway  the settlement was due to excessive moisture in the sub-base and sub-soil area  the settlement was part of the chain of events that led to or caused the damage claimed. There is no dispute the excessive moisture in the area was essentially stormwater that had seeped into the sub-base and sub-soil areas. It is accordingly plain the circumstances causing the settlement does not fall within any of the exceptions to the relevant exclusion. This is the case whether one accepts that:  stormwater had seeped under the slab through unsealed joints or the cracks  the cracks were caused by loads imposed by a heavy vehicle. Evidence more consistent that damage was caused by settlement In any case, the available evidence is more consistent with a view that the damage was likely caused by long term settlement of the relevant concrete slab. There is no dispute stormwater naturally drains towards the relevant area. There is also no evidence that the gaps between the concrete slabs were sealed, which meant stormwater could readily seep into the sub-base and sub-soil area. Bureau of Meteorology records further indicate that the property received a moderate amount of rain in the months leading to the discovery of the fuel line failures. There is also:  photographic evidence of “stepping” in the concrete slabs, which is an indication of settlement and differential movement of the slabs  6 reported incidents of contaminated fuel involving fuel dispensed by the failed fuel lines in 2012, which indicates there was moisture in the sub-soil and the Case No: 366458 Determination Page 4 of 10 fuel lines were already failing before the claimed vehicle impact (load) incident. These matters support conclusions that:  the sub-base and sub-soil in the relevant area were indeed exposed to and undermined by excessive moisture  the concrete driveway in the relevant area likely cracked and settled as a result, as suggested by the FSP‟s engineers and CG‟s initial opinion. It is unlikely that the damage to the property was caused by a single incident of a heavy vehicle cracking the concrete driveway. The property is operated as a petrol station and its concrete driveway was some 125mm thick. There is no suggestion the driveway thickness was inadequate so it should be expected to cope with regular vehicle traffic on a daily basis, including traffic from heavy vehicles (such as refuelling tankers or other large vehicles). If the driveway is somehow able to crack as a result of an incident of loads being imposed by a heavy vehicle, the reasonable inference is that it was likely due to fatigue failure of the slab as a result of its age, which may be excluded on the basis of wear and tear. No evidence damage was due to inoperable submersible pump The Applicant‟s broker has belatedly suggested there was an inoperable submersible pump in the valve body pit, which purportedly caused or exacerbated the presence of moisture in the relevant area. The Panel finds no evidence in the available material to support this proposition. Case No: 366458 Determination Page 5 of 10 3 Supporting information 3.1 Key expert evidence Expert evidence Record Key points Tenant ’s fuel tank expert ( T ) Report 8 August 2012  Fuel lines 1 - 6 for premium fuel were failing pressure test .  Nitrogen was used to see if any visible signs of leaks would appear .  Bubbles began appearing at the gatic cover and cracks near or around a security bollard after a few minutes .  Water was visible at all risers throughout the tank farm . Applicant’s consultant e ngineer ( CG ) Report 6 September 2012  Inspected site on 23 August 2012 .  Service station‟s driveway concrete paving was generally in satisfactory condition, with minimal evidence of cracking or damage .  Concrete paving surrounding an underground tank/pit showed significant cracking and some areas of the pavement were fractured .  Fractured pavement adjacent to the corner of the tank/pit, showed significant movement and deflection under normal pedes trian loadings .  Substantial volume of water was evident beneath the pavement level .  Recent increase in rainfall likely increased local groundwater levels and flows, which then appeared to undermine and cause the pavement sub grade to deteriorate and fail .  The sub grade failure created a potential void under the concrete paving and traffic loads then caused the concrete pavement to fracture and fail .  Repair would essentially entail removal and replacement of some 6m x 6m concrete paving, repair of underground services and fuel supply infrastructure, and reinstatement of sub grade material . Tenant’s repairer (M) Report 19 September 2012  Testing showed that tanks 2 and 4, and lines 1 - 6 have failed, so the failed equipment was immediately removed from service to prevent contaminated fuel from being sold .  The site uses a suction system so that one line per tank is “teed” to all pump positions onsite, which means that any line failure would result in the entire tank being removed from service .  Tank 3 is not in use due to unknown suction issues .  Concrete subsidence has occurred over the tank, possibly due to water pooling and run off from other areas of the forecourt .  Concrete subsidence may have contributed to the site‟s current fuel system problems . Case No: 366458 Determination Page 6 of 10  Gene ral run off on site and from the building is not directed to stormwater, and is causing instability to the concrete above the tank farm and possible slab failures .  The root cause of the failure of tanks 2 and 4 is unknown .  Quoted $228,280.93 (plus GST) to expose and tests tanks and replace the whole piping system using a non - corrodible (UPP) piping system .  Alternatively quoted $129,423.61 (plus GST) to expose and test failed and unused tanks, run one suction line from tanks 2, 4 and 5, install a new VR circ uit to existing fills, replacement of concrete for line works and integrity issues above tank farm, and retest entire system . CG Report 1 November 2012  Its initial assumption that the pavement failure was caused by rising ground water table (due to recent rains) was incorrect because excavations subsequently confirmed that the existing ground water table level was approximately 3m to 3.5m below finished surface level .  The corner of the concrete pavement (adjacent to the corner of the service pit) was likel y fractured by loading imposed by a large vehicle driving over it .  Service pit is located on a low point relative to the rest of the site, causing stormwater to naturally flow to this area .  Stormwater has penetrated the concrete pavement sub grade and sub grade tank through the cracks in the concrete .  Abnormal moisture conditions has resulted in water causing settlement of the service pit due to differential movement in the clay soils, undermined the pavement sub grade and increased the severity of the init ial concrete pavement failure .  A combination of the above events likely caused the failure in the fuel services pipelines . CG Report 17 December 2012  Clarified that its second report was not intended to provide 3 feasible alternatives for the cause of the pavement damage but rather, to provide a sequence of events that have “singularly, as a whole” caused the pavement and fuel lines damage .  The cracking of the concrete pavement is consistent with a single impact loading event because the fracture is clean, which is typical of strength failure rather than any type of fatigue failure .  Fatigue failure usually occurs over time and exhibits cracks over a large area, which eventually leads to a general failure of the concrete pavement as a whole .  The crack in the site‟s concrete pavement is inconsistent with fatigue failure, so by elimination process, the damage was likely caused by a single loading incident .  The concrete crack was at an internal corner of the pavement, adjacent to the service pit .  Internal corner s of concrete slabs are geometrical weak Case No: 366458 Determination Page 7 of 10 spots and are more likely to fracture under loading conditions .  The location of the crack at a geometrical weak point rather than general damage over the entire slab indicates it was likely cause by a single impact event .  The single impact incident likely occurred between 30 July and 12 August 2012 . FSP’s corrosion materials consultant engineer (CMET) Report 15 April 2013  The claimed impact crack is located in an area subject to traffic from light vehicles and fuel trucks .  The cracks in the slab were “well worn”, with evidence of progressive breakdown/crumbling of the edges over time, rounding of the cracks and lumps of concrete debris in the cracks .  There is no evidence of “residual sharp well - defined crack edges”, which is indicative of a recent fracture .  The age of the cracks was likely to be in excess of 12 months .  Photographs taken 3 weeks after the claimed incident shows moisture in the joints around the gatic cover .  This indicates there is significant moisture under the slab, which would compromise the sub grade‟s bearing capacity and explain the slab settlement and stepping across the construction joints .  The elevated moisture levels under the slab can be caused by: - Poor drainage around the slab - Insufficient dr ainage on the slab surface - Unsealed open joints in the slab  The reported 150mm of water ponding over the underground tanks suggests that gradual settlement in the area has occurred over an extended period .  It is improbable that the fuel pipe ruptured as a result of a single load impact incident .  The evidence suggests that the concrete in the area of the fuel tank was damaged by gradual settlement as a result of poor drainage .  This caused differential movement of the slab, and fractures and degradation of th e concrete edges as vehicles move across the joints . FSP’s structural and forensic engineer (RJA) Report 16 April 2013  Inspected site on 12 April 2013 .  Geological survey plan suggests that the site soil class is M (moderately reactive) but a geotechnical investigation is required to confirm this .  CG‟s suggestion that the service pit is located on a low point relative to the site is consistent with the photo provided by T, which shows the valve pit gatic cover to be under water .  Photographs supplied by assessor “C” show that the concrete pavement construction joints were not sealed, which would also allow water to seep under the slab . Case No: 366458 Determination Page 8 of 10  Photographs taken on 23 August 2013 show rising moisture was evident at the construction joints .  RJA does not agree with CG‟s suggestion that water would not have penetrated the concrete pavement if it was not cracked because: - The concrete construction joints in and around the gatic cover do not appear to be sealed - The gatic cover is located in an area where water was found to have ponded  M‟s report confirms that stormwater and run off from the supermarket outlet onsite was ponding at the depressed area above the valve pit gatic cover and underground tank area .  Site manager (DM) has informed that: - There were reports contamina tion involving 7 vehicles in the last year (ie. 2012), 1 concerning unleaded fuel and 6 concerning the premium fuel - He experienced ankle deep water (approximately 150mm deep) ponding above the underground tank area - He only saw the inside of the valve pit w hen it was opened and it was full of water on that occasion - The drain – that drains water from the onsite supermarket‟s roof and discharges into a drain pit (located on the west side of the building) – became blocked not long after he commenced employment, which was some 3 ½ years prior to RJA‟s 12 April 2013 site inspection  Bureau of Meteorology records for Hastings shows the area averaged about 80mm of rain in July and August 2012 .  Total rainfall between 30 July and 12 August 2012 was 33.2mm .  The site received about 10.2mm of rain at the time of T‟s site inspection .  Rainfall in May, June and August 2012 were 152.9mm, 122.8mm and 63.2mm respectively .  Majority of the original concrete pavement was in reasonable condition for its age, with the following de fects: - 25mm slab stepping at the F - F Road exit ramp - 2.5mm wide crack on the F - F Road entry ramp - 2.5mm wide cracks on the H Street ramp - Significant localised concrete distress (with exposed reinforcing) within the LPG service pipeline trench - 3.0mm wide crac ks in the south east area of the onsite supermarket  Concrete pavement is 125mm thick and is founded on at least 200mm thick crushed rock sub base .  The slab settlement was localised and caused by a combination of the following: - Long term consolidation settl ement of the fill material Case No: 366458 Determination Page 9 of 10 over the underground tanks - The difference in founding level between the valve pit and concrete pavement, which do not appear to be supported by or connected to the concrete valve pit - Degradation or loss of sub base and sub grade strength as a result of stormwater seeping under the slab over a long period of time, due to poor or inadequate pavement and stormwater drainage design and the lack of flexible waterproof sealants within the joints  The slab failure would not have occurred if the pavement and stormwater drainage was adequately designed and constructed . CG Email 6 September 2013  Reinspected site on 5 October 2012 to review existing site conditions after excavation works were completed .  The reinspection proved its initial ass umption (that rising ground water) caused the pavement damage was incorrect .  The initial construction of the underground tanks and associated pipe works effectively created a confined subsoil area deep with the clay soils .  The pipes were disposed of but th e site foreman advised that pipes were crushed and broken around the concrete pit . FSP’s structural and forensic engineer (FES) Report 19 December 2013  FES was previously a subsidiary of RJA .  There was a meeting between representatives of the FSP, assesso r C, RJA (now FES), the broker, CG and the insured on 22 November 2013 .  It was discussed and agreed: - It is unlikely that the depressed area of the concrete slab was constructed „as is‟ because a stormwater drainage pit would likely to have been installed a t the low point if this was the case - The concrete pavement over the underground tanks and valve pit had undergone local settlement, with water ponding occurring during significant rain events - RJA and CG also agreed that ponded water would seep through the cracks and defective slab sealant in the joints, which most likely caused the sub grade to soften - RJA and CG also agreed this gradual process may have accelerated after the drought (between 1997 and late 2010), when “normal” rainfall patterns returned . 3.2 Relevant policy wordings “ Definitions … Damage or Damaged means accidental physical damage , destruction or loss. … Case No: 366458 Determination Page 10 of 10 Cover We will pay up to the total sum insured in accordance wit h the Basis of Settlement for property that is damaged at the premises during the period of insurance . … Exclusions … 3. We will not pay for damage caused by or arising from: … (i) erosion,… subsidence, settling, seepage, shrinkage or expansion of eart h, vibration or other earth movement, unless caused by or arising from a direct c onsequence of an earthquake, subterranean fire, volcanic eruption or wat er escaping from a water main owned by a water supply authority. 4. We will not pay for consequential loss or any kind 5. We will not pay for damage caused directly by or arising directly from: … (b) gradually operating causes such as, but not limited to, wear and tear…; … (d) latent defect, inherent defects, faulty workmanship, faulty material, structural defects or faulty design; ”

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.