Denial of building cracking and door and window damage under two policies

FirmFinancial Firm (Unknown - Insurer)
Decided2015-01-23
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The homeowner claimed for cracking and door and window damage under two home policies, both denied for ground movement. AFCA rejected the P1 claim but found the P2 damage was caused by a broken stormwater drain, so the FSP must pay 50% of front repairs and up to $3,000 in professional costs.

Under P2 the FSP did not prove the ground movement exclusion applied, but damage predating the policy and areas away from the break were apportioned out.

Issues

Subjects and remedies

home or building damagepay claimpay compensationreassess claim

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim - Exclusion/Condition Determination Case No: 366048 Determination Page 1 of 12 Case number: 366048 20 January 2014 1 Overview 1.1 Dispute The Applicant has held two home building and contents insurance policies with the Financial Services Provider (FSP) under two different brand names (P1 and P2). The relevant policy periods are 10 February 2010 – 10 February 2011 for P1 and 8 March 2014 – 8 March 2015 for P2. This dispute arises as a result of the denial by the Financial Services Provider (FSP) of the Applicant’s claims for building damage to her property (cracks, gaps and door/window frames movement) under both policies. The FSP denied the claims because it says the damage was not the result of an insured event but due to earth/ground movement, which is excluded under both policies. The Applicant disagrees with this outcome and contends for P1 that the damage is related to a stormwater flood event in 2011 and for P2 that it was caused by an earthquake in March 2014. Alternately, the Applicant has submitted evidence of a broken stormwater pipe at the front of the property which may have caused the damage. 1.2 Issues and key findings Can the FSP deny the claim under P1? The FSP can deny the claim under P1 because the evidence, on balance, is insufficient to establish the loss occurred within the period during which the P1 policy was in force. Can the FSP deny the claim under P2? The FSP cannot deny the claim under P2 because the Applicant has established there was an i nsured event and the FSP has not established that the damage would not have occurred but for an event which is excluded. 1.3 Determination This Determination is partially in favour of the Applicant.  Within 30 days of notification of the Applicant’s acceptance of this Determination, the FSP is to obtain a quotation for the repairs to all damage to Case No: 366048 Determination Page 2 of 12 the external front area, front living room, internal courtyard, toilet, bathroom , stairs and matching upper level areas of the property.  Within 30 days of notification of the Applicant’s acceptance of this Determination, the Applicant is to provide the FSP with copies of the invoices for the reports from the engineer (E), plumber (T) and leak detection expert (P).  Within 45 days of notification of the Applicant’s accept ance of this Determination, the FSP is to pay the Applicant 50% of the quoted cost for repairs.  Within 45 days of notification of the Applicant’s acceptance of this Determination, the FSP is to pay the Applicant the professional costs she incurred based on her invoices, up to a maximum of $3,000. Case No: 366048 Determination Page 3 of 12 2 Reasons for Determination 2.1 Can the FSP deny the claim under P1? Evidence is insufficient to establish the loss occurred within the period during which the P1 policy was in force The Applicant has the onus to establish on the balance of probabilities that a claim fits the definition of an insured event and that the loss occurred within the period of insurance. If this onus is discharged, the onus shifts to the FSP to establish the application of any exclusion on which it relies to deny the claim. The Applicant has said the damage could have been as a result of flash flooding from a severe rainstorm event between 4 and 6 February 2011, as a result of an earthquake on 15 March 2014 or as a result of a leaking stormwate r drain. Under P1, the Applicant had cover for accidental damage. It is not in dispute the damage was accidental. The majority of the evidence provided by the Applicant is of a general nature and does not establish a causal link between the claimed damage and the flash flooding in February 2011, or any event that could have occurred while the P1 policy was in force. The FSP has presented the expert opinion of an engineer who states that the most probable cause of the damage was movement of the earth around the foundations as a result of prolonged drought followed by inundation and expansion of the clay soil. This event is specifically excluded under the terms of the policy. The Applicant’s only expert evidence suggests the damage was as a result of a broken stormwater drain and a neighbouring downpipe directing stormwater runoff to the insured property. The Applicant’s engineer (E) reports there was distress in 2007/2008 and has become worse over time, particularly since January 2014 when new cracks were evident. The Panel is not satisfied that there is a reasonable causal link between the damage and any insured event that might have occurred during the term of the first policy (P1). The Panel is satisfied the FSP is entitled to deny the claim under the P1 policy on the basis the Applicant has not established the loss occurred within the period of insurance. 2.2 Can the FSP deny the claim under P2? Applicant has established there is an insured event As mentioned above, the Applicant’s onus is to establish the loss fits the definition of an insured event and that it occurred within the period of insurance. Case No: 366048 Determination Page 4 of 12 The Applicant has held the second policy (P2) since 8 March 2013; it is a listed insured events policy. For the P2 policy, the Applicant’s onus is to establish he r loss fits one of the insured events as defined in the policy. As per above, from the three possible events the Applicant only has supporting expert evidence regarding the stormwater drain breakage. Under the policy, there is cover for “ escape of liquid” which is defined as “loss or damage to the building caused by liquid leaking, overflowing or bursting from any of the following … any drain, fixed pipes, roof gutters or guttering and rainwater downpipes, drainage and sewage systems”. Initially, the Applicant did not have any specific expert evidence regarding the damage to her property and the FSP argued the Applicant had not established an insured event occurred as required by P2. However, the Applicant has recently provided reports by E, her plumber (T) and her leak detection expert (P), which suggest the damage may have been caused by the breakage in the stormwater pipe and runoff from the neighbour’s downpipe. The FSP has not challenged these findings by reference to counter expert evidence and its initial response is that there is no insured event and in any case, there is an applicable exclusion. In the absence of evidence to the contrary, the Panel accepts the Applicant has established an insured event occurred and as per section 2.1 above, this damage is likely to have occurred sometime between mid-2013 and early 2014, during which time the Applicant was insured under P2. Accordingly, it is now incumbent upon the FSP to establish the application of the exclusion on which it seeks to rely to deny the claim. Evidence on balance indicates most likely cause of damage was broken stormwater drain The parties have argued at length about various possible contributing causes of damage. Details of the reports by the parties’ experts can be found in section 3.2 of this decision. A summary of the key conclusions of these reports is: Source Conclusions on cause of damage Applicant’s experts (T, P and E)  It is possible the footing to the front wall has been affected by sub surface water.  There is a possible crack in the stormwater drain underneath the front step area. Signs of water damage were more prominent around this area, which is in the immediate vicinity of the broken storm drain.  The most likely cause of distress can be attributed to localised footing edge heave due to abnormal moisture conditions caused by the break within the stormwater drain below the front stairs.  It is possible the discharge of stormwater direct onto the ground from the neighbouring lot would increase soil moisture conditions over time . FSP’s experts  Neighbouring house on the left has a downpipe discharging water onto the ground. The fall of land from this point is towards the Applicant’s Case No: 366048 Determination Page 5 of 12 (L and F) property. This may be related.  The observed damage has been caused by differential found ing soil movement. Having reviewed the available evidence, the Panel is more convinced by P and E’s evidence. This is because their explanations regarding the localised damage to the front of the property are:  supported by P’s CCTV footage showing the break in the stormwater drain (as opposed to L’s report which has not provided any CCTV footage)  provide a clearer understanding as to why the cracking damage, gaps and issues with doors and windows is worse at the front as opposed to pre-existing cracking that has seemingly not worsened in other areas  F’s findings appear to be based on general information of the area and possibly explain the pre-existing cracking damage at the property observable in 2009, but are not sufficient to explain why the damage around the front area of the property worsened suddenly in early 2014. The Panel is satisfied that the magnitude of the localised damage and the evidence that there is a broken stormwater drain under the area where the damage is worse, strongly suggests there is a causal link between the damage and the broken pipe. Although seasonal changes in moisture causing differential soil movement could arguably be considered a cause, it simply does not explain why the cracking damage worsened suddenly in early 2014. The Panel is satisfied the Applicant has established the most likely cause of the claimed damage at the front of the property was due to the escape of water from the broken stormwater drain. FSP has not established the application of an exclusion The FSP has relied on its policy exclusion for “Ground Movement” which excludes “erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement”. The FSP has failed to prove that the damage would not have occurred as a result of the insured peril but for the presence of an excluded peril. Accordingly, it is not accepted the FSP has established that the “ground movement” exclusion applies to the extent that it is possible to deny indemnity to the Applicant for the loss arising from the insured peril. FSP only liable for part of the Applicant’s claim However, the available evidence also suggests the damage that has worsened , and is most likely caused by the stormwater drain breakage, is localised at the front of the property and adjoining areas (front living room, internal courtyard, toilet, bathroom, stairs and matching upper level areas). Although F identified damage to the rear as well, there is no evidence to suggest this damage has worsened. Case No: 366048 Determination Page 6 of 12 The experts are also not in dispute there was pre-existing cracking damage and as per F’s findings, this could well have been caused by differential soil movement due to seasonal changes. For this reason, the Panel does not accept the FSP should cover areas (rear, including kitchen) that are not near the area where the stormwater drain broke. Further, even in the front areas of the property, where there is evidence of pre- existing cracking damage, the Panel is satisfied the FSP is not liable for damage that predates the policy period and is likely to have been caused by excluded causes. For this reason the Panel has determined that the cost of repairing the front section of the property (previously defined in 1.3 above) should be apportioned between the Applicant and the FSP. As there is no specific indication or any expert material that could indicate to what extent the cracking damage was caused or worsened solely by the breakage of the stormwater drain, the Panel considers it is fair and reasonable in all the circumstances that the FSP bears 50% of the cost of repairs to the front section of the property only. FSP is to cover Applicant’s expert costs Under paragraph 9.4 of the Financial Ombudsman Service’s (FOS) Terms of Reference, FOS may award the professional costs incurred by the Applicant in the course of the dispute. In this case, the Panel considers the expert material provided by the Applicant was crucial in establishing her case and as such it is satisfied the FSP should contribute to the Applicant’s professional costs, provided she can establish proof of said expenses. The reimbursement of these expenses should be made taking into account the limit of $3,000 outlined in the Terms of Reference. Case No: 366048 Determination Page 7 of 12 3 Supporting information 3.1 FOS approach for this dispute This dispute has not been the subject of a FOS Recommendation. Due to its nature, FOS has considered it appropriate to proceed directly to Determination in line with the Operational Guidelines to the FOS Terms of Reference. This decision has been made by a Panel consisting of an Ombudsman and two Panel members with extensive experience in insurance industry matters and consumer claims. There has been a full exchange of the relevant material between the parties and each party has had the opportunity to address the issues raised. 3.2 Key points on relevant materials/statements Record Key points FSP’s leak specialist (L) Report 1 Apr 2014  The insured property is one building divided into two houses.  PVC stormwater line was clear and free of breaks right through to the easement at the front of the property.  Pressure test to domestic hot and cold water lines passed.  Neighbouring house on the left has a downpipe discharging water onto the ground. The fall of land from this point is towards the Applican t’s property. This may be related.  Before the dry months, during a couple of wet years, there would have been a lot of water discharging onto the ground. FSP’s engineer (F) Report 15 May 2014  An inspection for a similar claim was carried out on the other house of the building. Results of the floor level survey and soil testing have been combined.  The site is on relatively flat land and considered to have poor surface drainage. The house is assumed to face west towards G Street.  Floor levels vary a maximum of 32mm. +12mm in the middle of the front/west living room to - 20mm at the southwest corner of the house.  There is a significant fall of 20mm across the west street frontage wall from the boundary wall towards the southwest corner of the townhouse, which i s mirrored with a 20mm fall in the adjoining house.  The soil test identified the soil as silty clay with medium to high plasticity. That is class M moderately reactive soils. Founding clay material is of relatively stiff consistency, high plasticity and ha s a relatively low permeability rate.  An increase in moisture content causes clay soils to swell, resulting in heave of footings. A decrease in moisture causes clay soils to shrink, resulting in settlement of footings.  These soils require large volumes of water accumulating over a prolonged period of time before it can penetrate to depths that would result in heave of founding soils below the footings.  A sudden and relative short term flooding event typically does not increase the fou n ding soil moisture con tent to an extent where it Case No: 366048 Determination Page 8 of 12 causes foundations to heave.  Any surface floodwaters would generally flow away and evaporate off without affecting the moisture content of the clay soils below.  There are different types of cracks and gaps in the exterior, entry, living, kitchen, internal courtyard and upper level areas.  Some of the external cracks are mirrored on the adjoining house. The Applicant notes the crack beside the entry door has been getting worse and widening over the last 1 – 2 months.  Doors and window frames have moved, with doors jambing and locks not latching.  The damage to the interior and to the majority of the exterior of the house is limited to cracks of 0.1 – 5mm. This is considered cosmetic damage only, with no structural damage observed. Such lev el of damage is not unexpected for structures founded on reactive clay.  The damage to the front exterior wall is between 1 – 15mm. This is still considered cosmetic damage with no significant structural damage. However, it may require some repairs to the mas onry walls.  The observed differential footing movement is in line with expectations given the age and construction of the building, the footing system, the site classification and the presence of trees.  The east end of the subject house appears relatively stable, with the majority of floor/footing movement occurring to the west end.  Some cracks in the external rendered masonry west wall contained accumulation of foreign debris, indicating they have been present for an extended period of time. Cracks are evi dent on the Google Earth street view photos taken in November 2009.  The cracking and footing movement had occurred prior to the subject event and is part of an ongoing long term foundation movement.  The cracking to the west wall of the house and mirrored o n the other house shows a distinct pattern expected as the corners of the wall appear to be dropping, relative to the boundary wall.  The February 2011 flood event did not cause nor contribute to the observed damage to the subject structure.  The damage is c onsistent with expectations given the structure’s age and construction and with the site founding clay soil conditions. The damage is cosmetic only. There is no structural damage.  The ongoing differential footing movement and subsequent cosmetic damage has been caused over a prolonged period by: 1. reactive clay founding soils 2. long term fluctuations in soil moisture contents due to seasonal changes 3. “drought” conditions between 1997 and 2010 followed by the return of normal rainfall patters 4. poor site surface drainage and absence of perimeter paving 5. recent low rainfall periods combined with high temperatures during the summer months of 2012/2013 and 2013/2014. FSP’s engineer (F) Supplementary Advice  If a shear failure of clay founding soil had occ urred at the house, there would be significantly more damage and it would have occurred immediately at the time of the flood, not three years later.  It is incorrect the founding soils have been weakened and susceptible Case No: 366048 Determination Page 9 of 12 24 June 2014 of being washed away. There is no evi dence the soil washed away from underneath the footings of the house.  F’s employee “RS” disputes noting a gap under the footing. Nothing was reported in the soils report and footing probe diagram. RS noted moisture in the ground (all soils contain a level of moisture) but he did not recall discussing “subsoil which had filled with water”.  The February 2011 event was flash flooding during a heavy rainstorm event that occurred over a 30 – 40 minute period and waters receded in less than 2 – 3 hours.  It was a sign ificant event, but engineers do not deem it a “prolonged flooding” in terms of time or to the extent that it had an effect on founding soils in the area.  It is not expected for the whole house to show changes in floor levels. By the nature of differential footing movements, a building’s footings will move differentially depending on the cause. In this case, more settlement has occurred towards the front.  F’s report does not specifically relate the soil movement to trees and root drying, although they are po tentially contributing factors. It appears trees (at the back) were not a major factor and extensive floor level differentials at the back of the house are not expected.  The smaller plants in the front garden, combined with other factors (unpaved/exposed g round, garden exposed to sunlight and drying, etc) can still be having an effect on causing differential soil moisture contents at the front of the property, compared to soils at the rear.  The subfloor was not viewed as access was not made available at ins pection. The area under the floor of 32 G Street was observed and it had historic moisture staining the soil surface and footings.  The cracks in walls painted in 2012 confirm the movement and crack damage is not recent and did not entirely occur immediately following the February 2011 flooding.  Further, the pattern of pre - event cracking is consistent with the pattern of the floor level deformations, thereby indicating the building movements are completely unrelated to the flood event.  The reappear ance of wall cracking supports the presence of ongoing reactive soil moisture variations and the damage being unrelated to the flood event.  The localised 5º slope of the front garden/land and path is still relatively flat.  The return of normal rain does no t always cause cracks to close up.  Seeing daylight through cracks and subsequent damage to window elements is not structural damage.  If the load bearing wall had sustained significant structural damage, it would no longer be providing support for the floor s/wall.  The Applicant carried out some maintenance of the garden areas of the house since the flood event. However, the works do not comply with recommendations of Australian standards or the CSIRO.  Open permeable garden areas do not help drain water away from the house. In fact, they allow rainwater to infiltrate into the founding soils and effect/vary the moisture content.  In light of this, the front garden area’s poor surface drainage provides factors to contribute to abnormal soil conditions that could lead to Case No: 366048 Determination Page 10 of 12 ongoing moisture content variations and subsequent soil movements.  The fact other brick houses and fences in the area are showing signs of cracking supports the finding that founding soil is reactive clays that are experiencing long term ongoing so il moisture content variations and movements.  F is unable to comment as to when or why the damage and movement to other houses occurred. F has not doubt a lot of the damage has been long term and is ongoing.  There was an earthquake on 14 March 2014 of a 2. 1 magnitude on the Richter scale. The subject site is over 32kms from the epicentre.  The Geoscience Australia site says an estimated damage and felt radius cannot be calculated because the magnitude is less than 3.0. F considers the damage has not been cau sed by the earthquake.  If a crack was noticed on 16 March 2014, soon after the earthquake event, it is merely a coincidence. In fact, cracking occurring in later summer/early autumn is usually associated with reactive founding soil drying. Applicant’s plumber (T) Report 13 Oct 2014  Crystallised salts were present on the soil in front of about one third of the width of the front subfloor wall. This is directly behind the entry steps on the northwest corner of the house. This is possible evidence of water being present in the soil beneath this part of the house.  Adjacent soil does not show the same salts and the soil moisture conditions are different from the corners of the same front wall, which is approximately 5m wide. There are no salts evident on the southwest corner of the front wall or evidence of efflorescence.  The house at 30 G Street has roof downpipes which are not connected to the stormwater drain. They drain directly onto loose brick paving. Stormwater from this house could possible run towards the front wall of 32A G Street (the subject property).  The house at 34 G Street is built of brick walls on a concrete slab. The brick wall adjacent to 32A G street shows a gap in the wall at the expansion joint. Normally, expansion joints of 10mm are allo wed for movement. This was has opened up to be a gap of 40 – 60mm wide.  It is possible part of the footing to the front wall at the house has been affected by sub surface water. This may have resulted in the front wall above the footing cracking with inward northerly direction. Applicant’s leak specialist (P) Report 19 Nov 2014  Storm drains to the front of the house are interconnected with the neighbouring (adjoining) property (32 G Street).  A possible crack in a 45 x 100mm bend underneath the front step are a was seen. A static test on this 1m section of drain found water level dropping instantly. This confirms the break on the 45º bend.  Rain head feeding this section of pipe is picking up both properties.  The storm drain from the centre courtyard out to the “LPOD” in the nature strip area had no evidence of major defect.  Visual inspection showed the signs of water damage were more prominent around the front step area, which is in the immediate vicinity of the broken storm drain. Applicant’s engineer (E)  Distress was first noticed approximately in 2007/2008 but only several minor hairline cracks were observed. Case No: 366048 Determination Page 11 of 12 Repo rt 26 Nov 2014  This has become particularly worse over time, particularly since January 2014, with new cracks evident.  Repair works were done about 2 years ago to internal plasterboard linings and distress has since reappeared in new locations.  The level survey indicates the floor is not overly flat, which is expected for the age and type of construction present at this site.  Considering the differenc e in level across the front elevation, it is evident levels increase from the right hand corner to the left hand side at the location of the partition wall.  The differential of level of the front half of the residence is almost double when compared to the rear. This is most likely due to the break in the stormwater pipe and is expected to have raised levels in the area due to the addition of moisture to the soils.  F’s floor survey indicates both left and right hand side of the façade are approximately 20mm lower when compared to the central partition wall between 32 and 32A G Street.  The high point at the partition wall is in the location of the detected break in the stormwater drain below the front stairs of 32A G Street.  Based on the location of the observ ed distress and on the floor survey, trees seem not to be having any major effects on the serviceability of the structure.  Several downpipes at the neighbouring lot of 30 G Street are draining directly onto the ground. It is estimated approximately 60m 2 of roof catchment area discharges onto the ground.  Due to the lack of drainage and the natural slope on the ground towards 32A, the stormwater is likely to flow towards the subject property and in turn increase the soil moisture conditions over time.  Events such as flooding cause an abnormal increase in soil moisture, particularly when the water takes prolonged periods of time to drain away. The longer the soils are exposed to flood waters, the more moisture would permeate through them.  The majority of the di stress was located to the front of the dwelling. The comparison between the observations done by E and F indicates the distress has become worse in the last five months.  The site is suffering from an abnormal increase of moisture at the edges of the footin gs found around the boundary wall. This increase in moisture is causing the soil to swell and the building to move.  The most likely cause of distress to the house can be attributed to localised footing edge heave due to abnormal moisture conditions caused by the break in the stormwater drain below the front stairs.  The fact the peak levels F recorded across the front elevation of the two houses is located directly in alignment of the broken drain further indorses this conclusion.  It is possible the discharg e of stormwater directly onto the ground from the neighbouring lot at 30 G Street would also increase the soil moisture conditions over time.  The damage witnessed does not pose any risk to the structural integrity of the building. Case No: 366048 Determination Page 12 of 12 3.3 Other relevant materials relied upon  P1 Product Disclosure Statement dated 1 November 2007.  P2 Product Disclosure statement dated 9 November 2011.  P1 Policy Change Certificate of Insurance applicable for the period 1 December 2010 to 10 February 2011.  FSP’s claim notes f or the claims under P1 and P2.  Various images of the claimed damage.  Parties’ submissions.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.