Home / Financial Firm (Unknown - Insurer) / Determination 365747
Determination 365747
Home building claim declined under ground movement exclusion
Summary
The applicants claimed for cracking and movement damage to their home after the FSP declined the claim. AFCA decided the FSP was entitled to decline because the policy's general exclusion for ground movement applied.
The general exclusion for loss caused by or arising from any ground movement defeats the claim even if escaping pipe water contributed to the soil movement, as the excluded cause is dominant.
Issues
- Claim denial primary · not upheld“The FSP was entitled to decline the claim because the circumstances of the loss are specifically excluded from cover under the policy.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of
claim
Determination
Case No: 365747 Determination Page 1 of 7
Case number : 365747 15 October 2014
1 Overview
1.1 Dispute
The Applicants hold a home building and contents policy underwritten by the
Financial Services Provider (FSP), covering their residential address.
On 24 February 2014, a claim was lodged for cracking and movement to the
home. After considering the loss, the FSP declined the claim on the basis that the
loss was not covered by the policy terms. The Applicants dispute that decision.
1.2 Issues and key findings
Was the FSP entitled to decline the claim?
The FSP was entitled to decline the claim because the circumstances of the loss
are specifically excluded from cover under the policy.
1.3 Determination
This Determination is in favour of the FSP.
The FSP was entitled to decline the claim. Although the FSP has conceded that
the loss resulted from an insured event, the policy specifically excludes any loss
that is caused, arises from or involves the actual circumstances of the loss.
Case No: 365747 Determination Page 2 of 7
2 Reasons for Determination
2.1 Was the FSP entitled to decline the claim?
The FSP accepts that the damage was caused by an insured event
The FSP‟s policy is a defined events policy. Therefore, the policy only responds
where the damage has been caused by one or more of the listed events, subject
to any exclusions. One of these listed events is escape of liquid from fixed pipes.
The onus rests with the policyholder to establish that a loss has been suffered
which is covered by the terms of the contract. Once the Applicants have
discharged this onus, it then shifts to the FSP to demonstrate that one or more of
the listed exclusions operates to defeat the claim.
It is not disputed between the parties that the damage to the home has arisen as
a result of soil and foundation movement at the site.
The Applicants assert the reason for the soil movement is due to numerous
cracked and broken pipes at the property, which have disgorged liquid into the
surrounding soils causing movement. As the policy includes the insured event of
„ liquid leaking, overflowing or bursting from any … fixed pipes …‟ the Applicants
consider the policy should respond.
The FSP has conceded that the Applicants have established a prima facie claim.
The loss arose from causes specifically excluded from cover
Engineering firm “RH” inspected the damaged building at the instruction of the
Applicants. RH concluded the damage had arisen as a result of soil settlement.
RH considered it was probable that the ground plumbing lines were defective,
allowing water into the soil, increasing the moisture content and affecting the
foundation bearing pressures, causing the differential settlement to the footings.
RH recommended the pipes be inspected by camera in order to determine if there
were any cracked or leaking pipes.
Building firm “C” subsequently undertook leak detection tests to the property
including examination of the sub ground piping by camera. C did not identify any
leaks under pressure but did note that all of the underground sewer pipes were
severely cracked and broken, leading to water disgorging into the ground. C
considered the leaking pipes had caused considerable damage to the slab and
footings.
Engineering firm "PB" were subsequently engaged by the FSP in order to
determine if the broken pipes had caused or contributed to the damage.
PB concluded that the original assessment of the soil at the site as class “H”,
given the complexities of the soil at the site, would have been better assessed as
a class “P”.
Case No: 365747 Determination Page 3 of 7
PB considered the slab construction and use of rigid pipe drains was not
compliant with the latest Australian Standard (being AS2870 issued in 2011). The
standard required drains emerging from underneath a building on very reactive
soil sites (class H, E or P), to incorporate flexible joints to accommodate
differential movement.
The version of the code applicable at the time of construction of the dwelling did
not stipulate such a requirement, however, it was regarded as best practice at the
time.
Ground movement at the site has resulted in the cracking of the rigid drain pipes.
The subsequent leaking of water has further exacerbated the existing ground
movement and is consistent with the concentration of damage around the en
suite, bathroom and laundry.
The construction of the apron slab structurally detached from the house on a
reactive site is not compliant with either the current code or the one applicable at
the time of construction.
Put simply, the method of construction utilised for the slab and piping was not
suitable for the soil type and the expected variations in soil moisture content; as
such the breakage of the pipes was all but inevitable and did in fact arise in this
manner. In PB‟s view, the broken pipes did not cause the ground movement,
rather the chain of events was the opposite in that the ground movement caused
the pipes to rupture.
Whilst there are minor differences in the findings of RH and PB, they are largely in
agreement that the cause of the damage to the home is as a result of differential
movement of the soils. The main point of difference in their findings is whether the
cracked and broken pipes are a cause or effect of the ground movement. An
engineer‟s findings are to be given greater weight than that of C as a builder,
given an engineer‟s expertise relating specifically to s tructural matters.
It is accepted that RH and PB are appropriately qualified and experienced to
comment on this matter and in the absence of conflicting information, the FSP is
entitled to rely on their findings.
After considering all of the expert eviden ce, the Panel prefers PB‟s report, given it
is logical, thorough and compelling. Further, whilst RH has opined the broken
pipes may be a contributing factor to the damage claimed, it is evident he
considered this to be only a contributing, not dominant fac tor.
When determining the level of cover afforded by the policy, the policy must be
read as a whole. In this instance, the general exclusions which apply to the
entirety of the policy must be considered in conjunction with the relevant insured
event.
The general exclusions specifically exclude loss or damage caused by or arising
from or involving any type of ground movement except where the ground
movement is covered under the insured events of „storm‟, „flood‟, „earthquake and
tsunami‟ or „explosion‟.
Case No: 365747 Determination Page 4 of 7
There is no suggestion that the loss arose from any of the exceptions set out
above.
Therefore, even if it were to be accepted that the water escaping from the cracked
and broken pipes was either the dominant cause or contributing factor to the soil
movement, which caused damage to the home, the policy will not respond.
It is also recognised that established case law provides that if there are two
proximate causes of a loss where one is subject to cover and the other is not, an
insurer is not liable for the claim as the excluded cause is dominant.
The policy specifically excludes loss or damage caused by, arising from or
involving any form of ground movement, other than in specific exceptional
circumstances, which, it is not disputed, do not apply in this instance. Given the
breadth and scope of the exclusion, it applies to defeat the claim and as such the
FSP has correctly declined the claim.
3 Supporting information
3.1 FOS approach for this dispute
This dispute has not been the subject of a FOS Recommendation. Due to its
nature, it was appropriate to proceed directly to a Determination in line with the
Operational Guidelines to the FOS Terms of Reference.
There has been a full exchange of information between the parties and each party
has had the chance to address any issues raised by the other. Material supplied
by the parties will only be referred to in this decision where relevant and in
context.
3.2 Expert Evidence
Record Key points
FSP’s expert ( PB )
Engineer‟s Report
19 May 2014
the house is a single story brick veneer construction built
on a reinforced concrete slab
the footing is founded on a flat block of land adjacent to an
open storm water drain
the property was constructed in 1993 by the present
owner‟s builder
an apron slab and open carport were constructe d at the
same time and the roof of the carport is integral with the
roof of the main house
the owner‟s engineer report classes the site as a class H
reactive site
a plumber has determined via the use of drain cam that all
underground sewer pipes leading aw ay from the house are
severely cracked
damage was first noted by the owners approximately ten
years after construction and the damage has steadily
Case No: 365747 Determination Page 5 of 7
worsened
cosmetic repairs have been attempted by the owner
however these do not address the underlying proble m with
the structure
the owners had not observed pooling or ponding of water
in the yard, from the storm water drain or otherwise
unexplained elevated levels of moisture
the apron slab forming the carport has moved 45mm away
from the house and 25mm across the house
these deformations are consistent with translation
movement of the apron slab relative to the carport roof
to comply with AS2870 an apron slab on a highly reactive
class H site or higher is required to be tied to the house
footing with steel rein forcement
the likely absence of such reinforcement indicates the
footing is of inadequate design and construction for a
residence on a class H site
extensive cracking was observed on tiles, ceilings,
cornices and walls on the north western side of the hous e
internal and external doors bind and swing shut under their
own weight indicating the walls are not plumb
floors throughout the house are not level and have a fall at
1 in 60 from front to back and 1 in 120 from north west to
south east
cracking of the concrete slab is visible throughout the floor
covering
cracking of the ceiling and cornices towards the centre of
the house are consistent with ground heave causing walls
on the centre of the slab to rise up and impact the roof
trusses spanning between the side walls
the extent and severity of damage is excessive and
indicates the footing is likely of inadequate design and
construction for a class H reactive site
the damage due to differential settlement is concentrated
around the en - suite in the south east and the laundry and
bathroom in the north west
the most recent version of the standard issued in 2011
requires drains attached to or emerging from a building on
a class H site to incorporate flexible joints to accommodate
differential movement
the previou s version of the code applicable at the time of
construction did not stipulate such a requirement however
inclusion of flexible joints was considered best industry
practice at the time
the inappropriate use of non - flexible drain pipes has likely
resulted i n the expected ground movements of a reactive
site severely cracking the rigid pipe drains as they emerge
from underneath the slab
the subsequent leaking of water into the reactive soil would
further contribute to any ground movement and is
consistent with the concentrations of damage around the
Case No: 365747 Determination Page 6 of 7
en - suite, bathroom and laundry
the rear of the house backs onto a designated green area
and watercourse which is an acid sulphate area, indicating
the area was likely to have been historically wetlands
historically wet areas indicate low bearing capacity of the
soil and the possibility of recent vegetation removal may
contribute to subsurface ground movement
the last few years have also had a number of high storm
water events which although not catastrophic would
con tribute in part to softening the ground which is
particularly problematic for reactive clay soils
it is likely the ground issues will be ongoing
for this site in which the soil conditions are complex, the
classification should be considered a “P” class in lieu of the
H class previously nominated as a H class is based on the
results of the expected movement to reactive clays only
in conclusion the damage has arisen as a result of the
differential settlement as a result of inadequate design and
construction o f the house footing
Applicant’s expert ( RH )
Engineer‟s Report
12 Mar 2014
the dwelling is a large four bedroom slab on ground with
tiled roof dwelling constructed around 1990
the construction is such that the stud work internally is a
metal frame
there is cracking evident to the bathroom with the floor
sloping 20 - 25mm to the south east
there is extensive cracking to the remainder of the walls
and cornices
the entrance is out of plumb as is the wardrobe in bedroom
three
floor levels need to be taken but i t is evident the floor of the
kitchen slopes approximately 25 - 30mm
there are expansion joints missing in the ceiling at the
kitchen/dining room junction
there are loose tiles in the laundry and the floor has settled
away from the walls, falling back toward the dining room
the solid glass wall panel in the bathroom has separated
from the wall and the floor leans to the external elevation of
the building
the master bedroom shows the south wall has settled,
there is a rainwater down pipe in this corner
at the south side of the dwelling there is a park with
extensive trees which would encourage extraction of water
from the soils due to the growth of roots extending to the
building‟s foundation system
there is cracking to the exterior brickwork
none of the juncti ons have expansion joins
the soil would be classified as class “H”
the area is flat terrain and as this is an alluvium soil the
inclusion of any moisture would change the bearing
Case No: 365747 Determination Page 7 of 7
capacity of the foundations to this building giving cause to
this settlement
the nearby tree growth is giving cause to movement in the
south area
a drain cam inspection and pressure test should be
conducted to the sewerage lines in order to detect any
leaking or broken pipes
should these be defective then this would add water into
and under the footprint of this building reducing bearing
capacity
should there be no broken pipes then the movement is
normal ground movement
the property is suffering from differential settlement
FSP’s expert ( C )
Builder
12 Mar 2014
a complete plumbing test was conducted on the kitchen,
bathroom, laundry and en - suite pipework with no pressure
leaks found
the underground sewer pipes were inspected with the aid
of a drain camera and this revealed that all underground
sewer pipes are severely cracked and b roken around the
house, allowing water to escape into the ground causing
subsidence
these breaks are not visible above ground and the owner
would have no way of knowing this was occurring
these leaks have caused considerable damage to the
concrete slab and footings which has resulted in
movement within the property
it was recommended that an engineer‟s report be obtained
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.