Home / Financial Firm (Unknown - Insurer) / Determination 364431

Determination 364431

Claim for collapsed retaining wall and neighbouring property damage declined

FirmFinancial Firm (Unknown - Insurer)
Decided2015-04-09
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

After a retaining wall collapsed during a storm and damaged the neighbour's property, the applicants claimed under building and legal liability cover. AFCA found storm damage to retaining walls excluded and legal liability not established, so the FSP may refuse payment.

The policy excludes storm damage to retaining walls, and the applicants could not show the collapse resulted from their negligence or legal fault.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim - Exclusion/Condition Determination Case No: 364431 Determination Page 1 of 7 Case number : 364431 9 April 2015 1 Overview 1.1 Dispute This dispute follows a claim by the Applicants for building damage and legal liability following the collapse of a retaining wall on 5 December 2013. The FSP rejected the Applicants ‟ claim for damage to the retaining wall on the grounds that the policy does not extend to cover storm damage to retaining walls. As for the legal liability claim for damage to the neighbouring property, the FSP is of the view there is insufficient evidence to establish liability. A Recommendation was issued by the Service on 27 November 2014. The Recommendation was substantially in favour of the FSP. The Applicants have rejected the Recommendation. In rejecting the Recommendation, the Applicants seek cover for the full extent of damage sustained to the neighbouring property. 1.2 Issues and key findings Have the Applicants established a prima facie claim under the building policy? The Applicants have not established a claim under the building cover provided because:  insofar as there was damage to a retaining wall, damage to a retaining wall caused by storm is excluded under the terms of the policy  the Applicants maintain the retaining wall is built on the neighbouring property and is not his wall. Have the Applicants able to establish a claim under the legal liability section of the policy? The Applicants have not established a claim under the legal liability section of the policy because:  the damage to the retaining wall was not caused by negligence or legal fault on behalf of the Applicants  the retaining wall was located on the neighbouring property and was designed and constructed by the owner of the property. 1.3 Determination This Determination is in favour of the FSP. The FSP is entitled to rely upon the terms and conditions of the policy and to refuse payment of the Applicants‟ claim. Case No: 364431 Determination Page 2 of 7 2 Reasons for Determination There has been a full exchange of material between the parties and each party has had the opportunity of addressing the issues that arise from the material exchanged. In rejecting the Recommendation, the Applicant has maintained that they seek cover for the damage sustained to the neighbouring property including replacement of the water tank, destruction of a planter box, replacement of the neighbour‟s lawn, replacement of a stormwater grated pit and the building of a retaining wall. The Applicants maintain the FSP was able to assess the damage to the retaining wall prior to repairs being carried out and further that it was necessary to carry out the repairs in order to prevent serious damage to the neighbouring property in the event of a further storm. 2.1 Has the Applicants established a prima facie claim under the building cover for the policy? Based on the information exchanged, it would appear that the Applicants originally claimed cover under the building section of the policy for damage sustained to the retaining wall. The FSP‟s claim lodgement notes indicate that the original claim was that the retaining wall had collapsed into the neighbour‟s yard. According to the notes, the Applicants had somebody come out and clean up the damage and a family friend JG who installed the retaining wall had come with a bob cat to clean the area. At the time of lodgement of the claim, the Applicants informed the FSP that JG had taken delivery of materials to rebuild the retaining wall. I note the Applicants informed the FSP that the retaining wall needed to be rebuilt to prevent further landslides. Following att endance at the Applicants‟ property by the FSP‟s assessor, the FSP formed the view that the retaining wall had been built by JG from comments made by JG. According to the assessor, they were informed that at approximately 9.00pm on Thursday 5 December 2013 the newly constructed section of the retaining wall had collapsed causing damage to the neighbouring property. The Applicant now says the retaining wall was not on their property but built and designed by the neighbour, 300mm onto the neighbouring property. In these circumstances as the retaining wall did not form part of the Applicants‟ buildings then the policy does not cover the loss. If the retaining wall was part of the Applicants‟ policy, then as the damage followed the storm, it would be excluded from cover. Case No: 364431 Determination Page 3 of 7 Have the Applicants established an entitlement to indemnity under the legal liability provisions of the policy? The Applicants have not established an entitlement to indemnity under the legal liability provisions of the policy. Although the FS P initially recorded the Applicants‟ claim as a claim for damage to their retaining wall which they believed had been built and repaired by a friend JG, the Applicants have since advised that:  the retaining wall was not on the insured‟s land but on the neighbour‟s land  the Applicants had no knowledge of whether or not a fault existed in the retaining wall as they did not build or cause the wall to be built  JG neither designed nor built the retaining wall but was engaged to carry out landscape work on the Ap plicants‟ property  the retaining wall collapsed when work was being carried out on the Applicants‟ property. No evidence has been presented by the Applicants to establish that the work being performed on the property was the cause of the collapse of the re taining wall. Whilst the FSP indicated it was prepared to grant indemnity to the Applicants under the terms of the policy, the grant of indemnity was provided subject to the investigations into the claim. The FSP formed a view that the collapse of the retaining wall was due to faulty workmanship. The FSP‟s assessor concluded there were clear shortcomings in the design of the wall which would have been identified by the appointment of a competent engineer or certifier. If the Applicants had built the wall then arguably, legal liability would flow from this. The evidence however, is that the neighbour was responsible for the design and build of the wall. If this is the case, then based on the evidence currently available, the collapse of the wall could not be said to be due to the Applicants‟ negligence. It may be that the work performed on the Applicants‟ property by JG somehow caused or contributed to the collapse of the retaining wall. This has not been established by the material exchanged. Based on the Applicants‟ own information, the retaining wall was built prior to the Applicants moving into the property by the neighbour and it was the original retaining wall that collapsed on 4 December 2013. I accept the collapse was most likely due to faulty workmanship and design. As this was the neighbour‟s property and in the absence of other evidence, I am not satisfied the information exchanged is sufficient to establish legal liability on behalf of the FSP. Case No: 364431 Determination Page 4 of 7 3 Supporting information 3.1 Information exchange There has been an exchange of the relevant material on which the parties rely, and each party has had the opportunity to respond to the issues raised. Whilst all of the information, has been reviewed, only the information that is necessary in providing this Recommendation has been referred to. 3.2 Relevant policy provisions “ What you are covered for – Insured Events We cover you for loss or damage to the building caused by an insured event which happens during the period of cover. There are some things we do not cover and these are shown in the „We do not cover‟ section of the following tables on pages 17 to 25 and in the „What we do not cover – general e xclusions‟ on pages 32 to 36. Storm We cover We do not cover Loss or damage to the building caused by a storm. … loss or damage to retaining walls, garden borders and free standing outdoor walls; … … Legal Liability We cover your legal liability to pa y compensation for death or bodily injury to other people, or loss or damage to their property, resulting from an incident which happens during the period of cover: • in connection with you owning or living in the building; and • at the insu red address. How to establi sh your loss … Proof of Loss Allowing us, a repairer or an expert appointed by us, to look at what is damaged is usually all that is needed to prove your loss. Sometimes though we might ask you to produce a copy of the most recent plans and drawings for the building, photographs of the building or other evidence that supports the extent of the loss you have suffered. If we decide that you are unable to reasonably substantiat e your claim, we might reduce or refuse your claim. How we settle building claims … We will not: • … • fix a fault that existed before the loss or damage occurred; Dealing with defects If a known defect is the cause of the damage We do not pay for loss or damage caused by a defect, structural fault or design fault at the building that you knew about (or should reasonably have known about) and did not fix before the loss or damage occurred.” Case No: 364431 Determination Page 5 of 7 3.3 Applicants’ evidence Evidence Key points Applicants‟ claim lodgement call 10 December 2013 “ What happened: Insured¿s retaining wall has collapsed into neighbours yard. Insured retaining wall is Besser block. Weather was raining at the time, but unsure if this was the cause of collapse.” (sic) Applicants‟ further claim lodgement call 17 January 2014 “The retaining wall has collapsed due to the rain.” Letter from Applicants‟ Solicitor 7 February 2014 “… The retaining wall was neither built nor designed by [JG] but was existing prior to [JG] being engaged to carry out landscape works on our clients‟ property. … As [JG] neither built nor designed the subject re taining wall, he could not be the primary cause of the wall collapsing through negligent design. … From your letter, is would seem that if [RP]‟s retaining wall was damaged as a result of the landscaping work being carried out on [the Applicants‟] land, t hat claim would be permissible under the policy of insurance.” Letter from Applicants‟ Solicitor 8 April 2014 “… 1. We are instructed that the wall that was damaged was not on [the Applicants‟] land but on [RP]‟s land. 2. The wall collapsed when work was being carried out on the [Applicants‟] land. The wall has been repaired. 3. Further, the [Applicants] had no knowledge of whether or not a fault existed before the loss or damage as the [Applicants] did not build the wall or cause the wall to be built. 4. The w all, not being on the [Applicants‟] land should be regarded as a building and thereby subject to the terms of their policy.” Written response to FSP‟s further enquiries 2 October 2014  Original retaining wall was designed and constructed by neighbor [RP]  Construction of original retaining wall was completed prior to the Applicants owning the property  JG completed landscaping works at the property on 3 December 2014  Original retaining wall collapsed on 5 December 2014  JG completed rebuilding the retaining wall on 4 January 2014  The Applicants have not yet paid JG‟s invoice in respect of the clean up and rebuilding of the collapsed retaining wall. 3.4 Expert evidence Record Key points FSP‟s expert (TA) Email 16 December 2013 “ I visited the site on Friday afternoon to have a look at the damage. The Insured could not be present, but I was able to discuss with their “family friend” (who built the wall) [JG] and the Claimant [RP]. Initial impressions are that the wa ll was poorly designed: too high for the type of wall, insufficient slope, and inadequate reinforcement. Drainage is an other (sic) issue, with the wall not being designed to Case No: 364431 Determination Page 6 of 7 bear the increased weight loading of the saturated soil (the same family friend d esigned as installed the drainage). The Policyholder has clearly had the job done “on the cheap” and I have some conc erns regarding planning approval (I am waiting to hear from the Insured in this regard) and this is going to cause problems in relation to liability. … If an engineer/certifier was involved, then they may also have liability, but the information from Friday suggests no such involvement (I am awaiting confirmation from the Insured).” FSP‟s expert (TA) Report 27 December 2013 - Insured premises is a newly constructed home. - JG designed and undertook landscaping works to Applicants‟ rear garden, including construction of retaining walls with labour provided by two family friends. - The works were done for free and had been complete d a week or two prior to the wall collapsing. - Blocks of the type used in the construction of the damaged wall are only intended for walls up to 1.2m high. The wall was constructed to a height of 1.8m - The wall had been reinforced with plastic dowels rather than steel reinforcement bars. - The wall was constructed with flat vertical surface (ie a 0 ° incline). Industry guides require an incline of between 6 - 18 ° for retaining walls between 1.08 - 1.2m in height. Engineering advice is required for walls of a greate r height - The Applicants did not obtain Engineering advice/approval and relied upon JG‟s advice in respect of the design and construction of the wall. - NSW Housing Code requires Local Council permission for the construction of retaining walls higher than 60 0mm. The Applicants stated they were not aware of this requirement and no planning approval had been sought for the wall‟s construction. - JG indicated he believed the cause of the wall collapse to be increased weight of the retained soil due to it having b een saturated by heavy rainfall and artificial watering of the newly laid turf. He also stated the installed drainage system would not function to full efficiency until the lawn was properly bedded in. - Bureau of Meteorology records in respect of rainfall do not support this proposition. - JG has overseen the construction of a replacement wall using outside contractors. Steel reinforcement has been used for the replacement wall, but no engineering input ha s been sought. - Wall collapse resulted in damage to water tank and garden/landscaping works on RP‟s property. FSP‟s expert (TA) Letter to Applicants 20 January 2014 “… The, collapsed, retaining wall at your property was constructed to a height of 1.8m from “Rockface” segmental concrete self - retaining blocks. The wall, and the drainage arrangements of the lawn/soil it retained, was designed by [JG], and constructed by [JG] with the assistance of others. For walls with a unit depth of 320mm (as used in your wall), the Conc rete Masonry Association of Australia‟s Design and Construction Guide MA53 “Segmental Concrete Gravity Retaining Walls” (Appendix D) permits construction to a height of only 1.08m where a 0o incline is used. Specialist engineering advic e is required where such walls exceed a height of 1.2m, due to the inherent risk of collapse. Despite your ret aining wall being constructed to a height considerably in excess of that permitted by the Guide, we understand that no engineering advice was sou ght or recommended by [JG] Case No: 364431 Determination Page 7 of 7 It is therefore our considered opinion that the primary reason for collapse of the wall was the negligent design by [JG] who, we not e, has not held the requisite construction licence since 1994. We are aware that James Gill ha s blamed a combination of heavy rainfall and lawn watering for causing extreme saturation of the soil behind the wall for its collapse. We disagree with this finding: weather records from the Bureau of Meteorology show only very modest rainfall on the date of collapse and nil rainfall in the days leading up to this. Clearly the wall, and the lawn drainage arrangements (also [JG]) ought to have been able to cope with the volume of water required to maintain newly - laid turf. … Instead, we consider the wall‟s collaps e to have resulted entirely from [JG]‟s negligence. Legal liability for the collapse should therefore be attributed to [JG].” FSP‟s Assessor‟s Report (SM) 23 January 2014 “Met gents at 2 storey home completed … in August, 2013 & was advised next door neighbour … had occupied their home for past 2 to 3 years. As part of the construction , the neighbour had to build a keystone block retaining wall on the boundary & this section measured approx. 9m long & was 1.5m high according to [JG]. After c ustomers occupied they got permission from the neighbour to add 2 further courses to the top of the keystone wall on the boundary to allow retaining of the insureds rear yard fill that they graded & topped with Buffalo lawn; this addition was completed by [JG] in September. In December, 2013 the wall collapsed during continuous rainfall & the neighbour demanded customers fix the problem as the wall & fill had flowed into his rear yard & damaged the water storage tank. Fearing legal action, customers arrange d [JG] to remove the debris from the neighbour ‟ s yard & replace the wall & they cash settled the water tank for approx. $2,000. [JG] told me the original wall had a 500mm sand fill behind it with a road base footing & has since replaced it with 500mm grave l filtration, agi drainage line at the base & has founded it on a concrete footing. ... The wall was on the boundary & was obviously under engineered by the builder who erected it & should not have toppled over after 2 to 3 years. … It would appear to has worn the total repair cost for a problem initiat ed by his neighbour & I have suggested he seek legal advice in respect to recovery of half the repair cost in the circumstances that have prevailed.”

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.