Home / Financial Firm (Unknown - Insurer) / Determination 364260

Determination 364260

Claim denied for house cracking attributed to foundation movement

FirmFinancial Firm (Unknown - Insurer)
Decided2015-01-30
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The Applicants claimed under their home building policy for wall and ceiling cracking they attributed to a 2012 storm. AFCA found the dominant cause was differential foundation settlement from reactive soil, which is excluded, so it ordered nothing.

The storm was not the dominant cause of ongoing damage two years later, and the policy excludes loss arising from settling, shrinkage or expansion of foundations.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim Determination Case No: 364260 Determination Page 1 of 8 Case number : 364260 30 January 2015 1 Overview 1.1 Dispute In 2012, the Applicants lodged a claim against their home building insurance policy with the Financial Services Provider (FSP) after cracking appeared in the bathroom, hall and bedroom walls and ceilings. The Applicants believed that storm water, which had pooled under their home during a storm, had led to the cracking. The Applicants had to use a submersive pump to remove the water. The FSP said the damage was not covered under the policy. The FSP reopened the claim in 2013 after the Applicants indicated the cracking was getting worse. The FSP reassessed the claim and concluded the policy did not cover the damage. 1.2 Issue and key findings Was FSP entitled to de ny Applicants’ claim ? The FSP is entitled to deny the Applicants’ claim because the dominant cause of damage to the house was not the storm. 1.3 Determination This Determination is in favour of the FSP. The FSP is entitled to deny the Applicants’ claim. Case No: 364260 Determination Page 2 of 8 2 Reasons for Determination 2.1 The FOS Approach I have decided this case on its merits, doing what is fair in all the circumstances and having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties. I am satisfied that the documentation I have relied on has been provided to both parties. This dispute has been expedited to a Determination. No Recommendation was issued. 2.2 Is the FSP entitled to deny the claim? Policy covers loss or damage for certain events The Applicants’ policy covers loss or damage resulting f rom specific events, including “storm” . However, the policy excludes loss or damage arising from “the setting, shrinkage or expansion in buildings , f oundations, walls or pavements” as well as “faulty design”. The Applicants bear the onus of establishing the cracking to their house resulted from an insured event. If the Applicants establish this, the burden then shifts to the FSP to establish that the cause of damage falls within an excluded event. The experts provided various reasons for the damage The Applicants and the FSP obtained reports from experts on the cause of the cracking to the house, which are summarised as follows: Expert Cause Assessor - FSP  Water entering under the house has caused isolated brick piers to sink, causing the internal walls to drop . Building consultant – FSP (G )  Damage was not caused by a storm.  Cracking was evident before the storm Rehydration of reactive found ation soils (rather than ground move ment from surface water) has caused differential movement (heave/shrink) moveme nt of the reactive foundation soil. Engineer – Applicant (R)  Cracking was m ainly due to differential foundation mov ement within different se ctions.  F oundation movement is due mainly to an event which occurred in recent years . Engineer – FSP (S)  Damage is caused by s hrink/swell characteristics of reactive soil foundation. This is indicat ed by the history of building movements .  Differential foundation movements are due to varying moist ure Case No: 364260 Determination Page 3 of 8 Expert Cause contents of foundation soil and varying footing provisions. The common theme from the reports is that the house is moving as the reactive foundation soil base swells or shrinks from varying moisture levels in the soil. I accept that this is exacerbated because of the different footing provisions used for the external walls compared to the floor. The dominant cause of the damage is differential settlement I must decide whether the dominant cause of the differential settlement was the 2012 storm. I accept that there was cracking in the house prior to the storm, even though only minor cracking was apparently noted in the pre-purchase report in 2002. G observed repaired cracks in 2012. The house is continuing to move. This is supported by S’s observa tion that cracks identified in G’s 2012 report showing ridging of repaired cracks, had since re- opened. The Applicant states that the cracking has been getting continually worse since 2012. On balance, I do not accept that the 2012 storm could be continuing to cause damage two years after the event. This is supported by the assessor’s comment that six months should pass before repairs works commenced because it would take about this time for the water to d ry, although it could be faster given the good sub floor ventilation. The photos taken by the experts show that there is continued dampness in places at the sub floor, given the sub floor is uneven and is below the external ground. I accept that this, when combined with reactive soil and different footings systems, has caused the damage to the Applicant’s home. The damage is not caused by an insured event and as such, the FSP is entitled to deny the claim. In reaching this conclusion, I acknowledge that the FSP’s experts did not obtain a soil report, but instead relied on their experience in identifying the soil type. However, while the Applicant’s expert criticised this (and it is a valid criticism) it is telling that the Applicant’s expert did not dispu te the conclusion reached of the soil type. Case No: 364260 Determination Page 4 of 8 3 Supporting information 3.1 Policy wording “ The events we cover Storm If loss or damage is caused by a storm. For example, hail damages your roof or a storm in your local area may cause water to build up in your street gutters. Covered ► violent wind, cyclone or tornado ► thunderstorm, hail, rain or snow ► sudden, excessive run-off of water as a direct result of a storm in your local area. Exclusions for all cover These exclusions apply to all cover under your policy. … What we don't cover Loss, damage, injury or death arising from: … ► the settling, shrinkage or expansion in buildings, foundations, walls or pavements … ► faulty design or workmanship …” Case No: 364260 Determination Page 5 of 8 3.2 Expert reports and main documentation Record Key points Claim form Dated 30 April 2012  Water from heavy rain fall had not drained away  Insured noticed cracking in certain rooms  Insured believed cracking in the bathroom, hall and bedroom is due to water pooling under the house Assessor – Building company Attended site 3 May 2012  Inspected under house – some settlement in isolated piers – caused floor to drop in bedroom – cracks to appear in hallway and i n ceiling next to air conditioning return outlet  Property appears to be on clay foundations which are highly reactive to moisture  Maintenance issues – insured advised to engage contractor to install dish drain down side of house to drain surface water comi ng from neighbour’s property  Recommended FSP confirm coverage as damage that has occurred was due to water entering under the house which has caused isolated brick piers to sink causing the internal walls to drop.  Noted that any remedial work should not oc cur for approximately 6 months to allow for the foundations to adequately dry and settle.  The property has good ventilation and the foundations may dry out before then. FSP’s expert – Building consultant (G ) Report dated 25 May 2012  Inspected s ite 23 Ma y 2012 – included sub floor  Observed majority of cracks display earlier patch repair and some ridging (where the fill material from repair is subsequently compressed from further movement)  Cracks also occurred in areas not part of the current claim for damage.  Floor movement and crack damage to whole house due to differential movement ie heave/shrink movement of reactive foundation soil because of moisture variations within the reactive fou ndation soil  Under floor ground surface is lower than the external ground and likely to pond water from surface run off during periods of heavy rainfall.  Differential movement of house compounded by variable structural bearing (concrete footings for external walls set deeper than brick pier footings for the floor)  House within sphere of influence from tree roots  Recent movement more to do with rehydration rather than ground movement induced by surface water flowing beneath house  Concluded movement and crack damage to house not from storm event or leakage from house or public utility services  House will continue to experience variable movement and crack dama ge from differential ground movement more so Case No: 364260 Determination Page 6 of 8 Record Key points in periods of infrequent rainfall  Photographs provided Applicants’ expert – Engineer (R) Report dated 2 March 2014  Inspected site 1 February 2014  Did not access sub - floor  “…intense cracking in some external and internal walls and separation gaps between floor and some walls are mainly due to differential foundation movement within different sections of structural elements caused by varying moisture (swell/shrink) around the perimeter of house which then graduall y spread to interior.”  Concludes that: “since the house is approximately fifty years old and the fact t h at cracking started to emerge only in the last couple of years; it’s in the Author’s opinion that foundation movement is due mainly to an event which oc curred in recent years” and combined causes were presence of a palm tree and lawn/soil in direct contact with house on one side of the house.  Refers to pre - purchase inspection report dated 26 September 2002 where only minor cracking was reported  Disputed G ’s conclusions  Photographs provided Email from G to FSP regarding R’s report of 2 March 2014 Dated 12 March 2014  R did not inspect sub - floor, whereas he did  R did n o t use a spirit level of other instrument to as certain whether the house was experiencing heave or shrinkage  No explanatory ground excavations were performed to asc ertain footing type or depth  R d id not ob serve that the ground surface beneath the house is lower than the external ground  R did not note the large trees growing in neighbouring prop erties  R did not note previous cracks and evidence of repair  R’s conclusion is at odds with CSIRO statement that “because of low absorption and expulsion rate, this phenomenon [increase in volume f ro m absorption of water] will not usually be noticeable unl ess there are prolonged rainy or dry periods, usually weeks or months depending on the land and soil characteristics.” FSP’s expert – Structural building engineer (S) Report dated 21 March 2014  Inspected property on 18 March 2014  Found examples of previo usly repaired wall and ceiling cracks evenly distributed throughout original house sufficient to establish history of building movement  Cracks previously reported as being closed in G ’s report had reopened – reversal of movement indicative of shrink/swell characteristics of a reactive soil foundation under house experiencing moisture variations  Variable horizontal alignments of architraves related to history of building movements  Increased wall/ floor separation – further evidence of Case No: 364260 Determination Page 7 of 8 Record Key points foundation movements  Uneven floor levels indicating shrink/swell movements coming from supporting foundation  In addition – rainwater downpipes discharge directly into ground beside house walls; drainage issues; tree root zone of influence (large 30 metre tree in neighbouring p roperty)  Under floor inspection – foundation soil a reactive clay (as determined by small but identifiable shrinkage fissures on the surface).  V ariable surface height of the foundation and variable moisture under adjoining footings would create differential movements in house  Concealed rot from previous bathroom leak accounted for some of the drop in the hallway floor below the bathroom wall.  Wind and sunshine will be assisting evaporation near the exterior foundations, compared to the interior  Commented on R’s report  Cause of damage related to differential foundation movements due to varying moisture contents of foundation soil; differential movement due to varying footing provisions; varying effect of tree root systems. Applicant’s expert – En gineer (R) Report dated 26 May 2014  Responded to S’s criticism .  Noted large tree referred to was in neighbouring property, not within inspection site  That there was no protection to the sub floor from solar and wind drying effects, is a benefit as good su b - floor ventilation is necessary  The downpipes referred to by S are not on the side where the damage has occurred and are on a slope that runs away from the property.  The photo of the sub floor space included in S’s report is for the side wall of the orig inal house where there is no external damage and all downpipes are connected to the storm water.  The pre - purchase inspection didn’t indicate any signs of major cracking  S did not undertake or request any checking of the type of clay or class of soil. FSP’s expert – Engineer (S) Report dated 20 June 2014  S provided a detailed response to the various criticisms R made in his report dated 26 May 2014  Ventilation at the side of the house may mean sub floor would dry at varying degrees – that which is expo sed to the sun and wind will dry faster. This can adversely effect footings.  Any discharge of water in the area will be a moisture feed to a reactive clay soil.  The photo of the sub floor is ce ntral and not a side wall as Case No: 364260 Determination Page 8 of 8 Record Key points s uggested by R.  S has not seen the pre - purchase inspection report. In any event previous damage may not have been recognisable beneath the sale make - over. Report from G 23 June 2014  G provides comments on why the methodology adopted by R is flawed. Applicant’s expert – Engineer (R) Report dated 15 September 2014  R rebuts each of the cri ticisms of its reports made by G and S  “ … when a storm events happens, like the one which occurred in the suburb where the property is located in 2012, the soil gets saturated underneath the house and up to 2m arou nd the parameter of the house which affects the sub - structure and leads to cracking and / or m ovement . The duration of cracks settlement depends on whethe r the soil dries up again and how long it takes for that to happen. ”  There has been no proper laboratory testing of the soil.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.