Home / Financial Firm (Unknown - Insurer) / Determination 363715

Determination 363715

Denial of claim

FirmFinancial Firm (Unknown - Insurer)
Decided2015-03-11
ProductGeneral Insurance · Other general
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed for damage to an ultrasound machine under an asset protection policy. The FSP declined as the loss arose from an internal fault, which is excluded, and AFCA determined the decline was correct.

The policy covers only external causes, and the applicant did not establish on the balance of probabilities that the loss arose from an external event.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Small Business/Farm Insurance - Commercial Property - FSP Decision - Denial of claim-Exclusion/ condition Determination Case No: 363715 Determination Page 1 of 7 Case number : 363715 9 January 2015 1 Overview 1.1 Dispute The Applicant is a beneficiary of an asset protection insurance policy underwritten by the Financial Services Provider (FSP). The po licy covers a Phillips IE33 ultrasound machine. On or about 5 December 2013 the FSP was notified of a claim for damage to the machine. The FSP denied the Applicant’s claim on the basis that the loss was excluded by the terms of the policy. 1.2 Issue and key findings Was the FSP entitled to decline the claim? The FSP was entitled to decline the claim because the cause of the loss is specifically excluded by the terms of the policy. 1.3 Determination This Determination is in favour of the FSP. The FSP was entitled to decline the claim. No further action is required on behalf of the FSP. Case No: 363715 Determination Page 2 of 7 2 Reasons for Determination 2.1 Was the FSP entitled to decline the claim? The Applicant is required to establish a prima facie claim The policy provides cover for accidental loss or damage to the machine from external causes, subject to any exclusions. It is accepted Insurance law that the Applicant carries the initial onus of proving that an event covered under the terms of the policy has occurred. This is known as a prima facie claim. Once the Applicant has established a prima facie claim, the onus shifts to the FSP if it wishes to deny the claim on the basis of an exclusion under the policy or some other basis. Expert evidence The machine was inspected by the original equipment manufacturer (OEM) who found no direct cause of failure. The fault was noted as being present in the upper memory blocks (UMB), with no video signal evident at the point of failure. However, the power supply unit (PSU) was still functional, indicating power was still being provided to the machine. The FSP appointed loss adjuster “JA” to review the information provided and tender a technical opinion as to the cause of the loss. JA considered it unlikely that a power surge had caused the damage to the machine. This was on the basis that had a power surge occurred, the PSU would have been the first damaged component, as it was the initial connector point to the mains supply. That the PSU was still operational, suggests no power surge had occurred. Rather, the fault appeared to lie with the UMB. Whilst the OEM recommended replacement of the PSU, this was on a precautionary basis only. The electricity supplier has confirmed there is no record of any power surges in the area on the date in question. There is no evidence of any storm activity in the area on the date of loss. Further, had the premises experienced a power surge, it is likely that any other appliances plugged in at the time would also have been affected. That there were reportedly no other items damaged, is suggestive of no power surge occurring. The Applicant has not provided any contrary expert evidence The Applicant disputes JA’s findings and raises issue with the fact that JA did not personally inspect the machine, but rather relied on the reports submitted by the OEM. The Applicant was given the opportunity by this Service to obtain his own report from a suitably qualified person. However, the Applicant did not provide any Case No: 363715 Determination Page 3 of 7 additional information in support of his case. As a result, JA ’s report is unchallenged. It is accepted that JA is appropriately experienced and qualified to comment in this matter. That he did not personally inspect the machine does not prevent him from assessing the likely cause of the failure, having had recourse to review the findings of the OEM. In the absence of conflicting information, the FSP is entitled to rely on JA’s findings that, on balance, the loss arose as a result of an internal fault with the machine. Analysis report A copy of an analysis report undertaken over the period of 28 February 2013 to 4 March 2013, has been supplied. It is unclear who undertook this analysis although it is assumed to be the OEM. It is not clear if JA was made aware of these reports. The report shows that the system shutdown abnormally and was restarting without having been shut down properly. The analysis shows three faults on 28 February 2013, one fault on 1 March 2013 and three faults on 4 March 2013. This is suggestive of an ongoing internal issue with the machine. The analysis details a number of potential causes and/or troubleshooting techniques to remedy the problem. It is of note that none of these items listed in the analysis were found to be evident upon inspection by the OEM in October. The applicant has also not addressed the issue of whether the unit remained operational between March and when the OEM inspected it in October. On balance, it appears likely that it did remain operational in the meantime. It is unlikely that any external factor would cause the intermittent problems in March and then lie dormant until October. The policy covers loss arising from an external cause The policy provides damage cover which is caused by external means. Therefore, the damage must arise from some factor external to the machine itself. It is of note that the precise cause of loss has been unable to be determined. However, the evidence presented suggests that the loss arose as a result of the failure inherent to the machine itself. That is, an internal cause. This is excluded by the terms of the policy. No evidence has been presented to suggest the loss arose from any other external cause, for example, impact to the machine or malicious damage. Whilst the OEM report does not conclusively establish the cause of the loss, it is of note the purposes of the OEM’s report was not to establish whether an internal or external fault caused the failure. Rather, their commission was to establish where the fault lay and how to remedy it. Case No: 363715 Determination Page 4 of 7 The unit was purchased in 2009 as an ex-demonstrator model. JA confirms that the low-voltage reading from the PSU is most likely due to the drying out of the electronic capacitors, which occurs due to prolonged use of the unit and is considered to be general wear and tear experienced over its lifespan. In any event, whilst the cause of the UMB failure is not been determined, there is nothing to suggest that this arose as a result of any external factor. After considering all of the available information, on balance, the loss is attributable to an inherent failure within the machine itself, being an internal cause. As such, the Applicant has not met the onus upon him to establish that the loss arose from an event covered by the terms of the policy. That is, the Applicant has not demonstrated that the loss arose from external causes . On this basis, the FSP has correctly declined the claim. Case No: 363715 Determination Page 5 of 7 3 Supporting information 3.1 FOS approach to this dispute This dispute has not been the subject of a FOS Recommendation. Due to its nature, it was appropriate to proceed directly to a Determination in line with the Operational Guidelines to the FOS Terms of Reference. There has been a full exchange of information between the parties and each part y has had the opportunity to address any issues raised by the other. Material supplied by the parties will only be referred to in this decision where relevant and in context. 3.2 Expert Evidence Record Key points FSP’s expert ( J A) Loss Adjuster’s report 27 Jun 2014  instructions were to undertake a technical review in relation to potential causation and the appropriate policy response  examination of the claim documents has been completed  we understand the unit was left on overnight as normal practice to allow transfer of data  the following morning the unit would not restart and the manufacturer (OEM) was requested to investigate  the OEM found a video signal to the monitor although the power supply unit (PSU) was operating (albeit at a lower level)  the upper me mory blocks (UMB) were not logging data from the input system  the OEM attempted to repair the unit by replacing the video drivers and upgrading to match the current component firmware  this was unsuccessful in testing, revealing that the complete UMB assemb ly would require replacement along with the PSU on a precautionary basis  we understand that repairs have not yet been affected, pending the outcome of this claim  the OEM advised in their report that there is no evidence of a direct cause of breakdown  the i nsured has speculated that this occurred as a result of a power surge on the night  records from the bureau of meteorology were obtained which confirm that no storms or lightning were recorded on or around the date of loss  there also appears to be an absenc e of reported damage to any other equipment in the facility  when examining power fluctuations as the potential damage trigger, it is logical to commence investigations with the PSU Case No: 363715 Determination Page 6 of 7  as the PSU is the first exposure to incoming mains electricity supply, any adverse power event will affect this component first  the PSU was reported a s not operating correctly, operating with voltage lower than normal acceptable limits  this type of fault is not consistent with exposure to adverse voltage but rather indicative of internal deterioration of the PSU components  the PSU contains electrolytic capacitors that will dry out and lose efficiency after an extended period in service particularly where the unit is powered 24 hours a day  as this process develops the tolerance be gin to drift and the voltage output on the PSU will gradually fall below normal operating limits  the PSU output was only marginally below the tolerance limit for this unit and not sufficient to prevent correct operation  had there not been the fault with UM B assembly, there is little doubt that this machine would have operated correctly  it is likely the PSU was in this condition prior to the incident  whilst the cause of damage to the UMB assembly has not been determined, the evidence indicates it is highly u nlikely this is as a result of a power surge  had a power surge occurred, the adverse voltage would need to pass through the PSU and upstream to UMB without damaging other components  this is not a plausible occurrence particularly in the absence of other eq uipment being affected  we consider the cause of the damage the UMB is as a result of an internal electronic breakdown within the machine operating components Applicant’s expert OEM service report 21 Oct 2013  system shutting down with no indication of direct cause  monitor displays no video signal at point of failure  PSU remains but UMB not logging  suspect UMB/video card failure  try to repair using new 9800 video cards including software system upgrade for compatibility  if problem persists, new UMB assembly unit will be required Applicant’s expert OEM Service Report 24 Oct 2013  original problem reported was system shutting down with no indication of cause  monitor displays no video signal at point of failure  PSU remains but UMB not logging  new vi deo cards installed and reloaded new software system but system still failed to process correctly  new UMB assembly required  also marginal supply below system operating Case No: 363715 Determination Page 7 of 7 specifications, replacement of PSU advised Applicant’s expert Analysis Report 29 Apr 2013  the system shutdown abnormally  the system is starting up without having been shut down properly  corrective action includes:  asked if the site had lost power or if the user turn the power of for any reason  various issues can cause a system to hang requiring the user to switch off the power  verify that no one entered Tech admin in the setups, which can reset event logs and incorrectly indicate an abnormal shutdown  assuming that the system powered off by itself , likely cause is a defective PSU or a de fective PCB  with such failures the system loses all power and causes an indicator to flash  depending on the cause there may or may not be a user recovery  a hard fault is not recoverable  a marginal voltage or overcurrent error may allow a circuit breaker cy cle to reset supply and allow the system to restart  majority of overcurrent faults are due to either a defective channel board or SPD assembly  the majority of power supply voltage faults are due to variation of the voltage which may be corrected by readjus ting the supply  replace the defective component or perform power supply adjustment

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.