Home / Financial Firm (Unknown - Insurer) / Determination 362158

Determination 362158

Quality of fire repairs, temporary accommodation and compensation sought

FirmFinancial Firm (Unknown - Insurer)
Decided2014-11-19
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The insured claimed that the insurer's builders had not properly completed fire repairs, causing driveway stains, an unlevelled floor and ongoing temporary accommodation and compensation claims. AFCA found the repairs met the policy terms, the stains and floor were not established, and no temporary accommodation or compensation was payable.

The insured bears the onus to prove a covered loss caused by the insurer or its builders, and the evidence did not establish that the roof, driveway, floor or other works were defective or caused by the fire repairs; compensation requires a failing by the FSP under the policy.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - Service - Service Quality Determination Case No: 362158 Determination Page 1 of 8 Case number : 362158 1 8 November 2014 1 Overview 1.1 Dispute The Applicant has made a claim under his household insurance policy following a fire at the Applicant’s home in September 2012. The Financial Services Provider (FSP) accepted the claim and carried out the repairs. This dispute relates to whether the repairs have been completed, whether the FSP has caused additional damage, whether the FSP is required to pay the Applicant ongoing temporary accommodation costs and whether the FSP is obliged to pay compensation to the Applicant. 1.2 Issues and key findings Has the FSP completed the repairs to a satisfactory level and in accordance with the requirements of the policy conditions? The FSP has completed the repairs to a satisfactory level and in accordance with the policy conditions. Is the Applicant entitled to ongoing temporary accommodation costs? The Applicant is not entitled to ongoing temporary accommodation costs. Is the Applicant entitled to compensation? The Applicant is not entitled to compensation. 1.3 Determination The Determination is in favour of the FSP. The FSP has met its obligations in accordance with the requirements of the policy terms and conditions. Case No: 362158 Determination Page 2 of 8 2 Reasons for Decision This Determination has been the subject of a Recommendation issued by the Service on 7 October 2014. It was the Case Manager’s Recommendation that the FSP had met its obligations in accordance with its requirements under the policy and had completed the rectification of the repairs. Further, it was the Case Manager’s Recommendation that the Applicant was not entitled to ongoing temporary accommodation or compensation. The Applicant has provided a further submission as to the circumstances of the loss and the basis for the rejection of the Recommendation. The FSP has not provided a further submission but has relied upon the material previously provided. In making this Determination, I have decided the matter on its merits and in regard to the relevant law, good industry practise, codes of prac tise and previous FOS decisions. I have taken into account all of the material submitted by the parties both before and after the Recommendation and I am satisfied that the documentation I have relied upon has been provided to both parties. 2.1 Has the FSP completed the repairs to a satisfactory level and in accordance with the requirements of the policy conditions? Damage to the lower roof The evidence confirms that there was damage to the roof in February 2012, which pre-dates the fire, the subject matter of this dispute. The Applicant says that the original damage was fixed and the Applicant continued living in the home, without water leak, until the subject fire in September 2012. The Applicant says that the FSP’s builders “ took access to ” his home for 17 months until February 2014. The Applicant says that if there was a leak continuing from March 2012 it would have come to the notice of the builder during the renovation process. If it had come to the notice of the builder, the Applicant was not advised. Further, the Applicant says that to the best of his knowledge, there were workers in the area of the leak, and the leak happened a few days after the work in that area was performed. On the other hand, the FSP has produced reports to the effect that the cause of the leaking roof was incorrect flashing and faulty sarking. Subsequent reports have confirmed that the rectification of the flashing and faulty sarking was never completed. The Applicant argues that the FSP’s builder did not install the down pipes spreader to Australian standards and that this is the cause of the leaking. Case No: 362158 Determination Page 3 of 8 However, as detailed within the Case Manager’s Recommendation, the evidence confirms that the down pipes spreader was present on the lower roof at the time of the February 2012 event and it was in fact the incorrect flashing and faulty sarking which was the cause of the leak and not the spreader. Having considered all of these matters and given that the original problems which predated the fire (that is the incorrect flashing and fa ulty sarking) were never rectified, I am satisfied, on the balance of probabilities, that the leaking roof is not related to the fire, the subject of this dispute and thus the FSP has met its obligations in respect to the roof. Oil and other stains to the driveway The Applicant refers to oil and other stains on the driveway, of which he advised the FSP, by email of 7 April 2014. It is settled insurance law that the Applicant carries the initial onus to show that the loss claimed has arisen from an event covered by the terms of the policy. I accept that whilst the relevant event covered by the terms of the policy is the fire of September 2012, the obligations of the FSP extend to rectifying any damage which is caused by the FSP’s appointed builders during the home repair process. The difficulty for the Applicant is that the handover of the keys to the home took place after the completion of the fire damage repairs in February 2014 and even though the Applicant stood in the driveway, talking with the representative of the FSP’s builder, at that time, he did not raise the issue of the oil and other stains on the driveway at that time. It was only within the Applicant’s email of 7 April 2014 , that the question of stains to the driveway was raised. The Applicant says that it was getting dark at the time of the handover and the Applicant said he did not have the opportunity to go through the external checks of the house. In addition, the Applicant says that the driveway was covered with debris after the fire and that the driveway was the main and only access to the building for the builders. Whilst the Applicant confirms that he engaged a tiler and landscape gardener to attend the property after the handover, he says that the landscaping has not occurred and it is much more likely that the stains occurred during the 17 months of repairs to the building, rather than the one day that the tiler was on the premises after the handover. Finally, the Applicant says that there are stains along the side of the house. Notwithsta nding the Applicant’s argument with regard to the stains, it is difficult to understand why the FSP’s builder did not note the stains at the time of the handover or why the Applicant waited over a month to advise the FSP of the stains, after the handover. Case No: 362158 Determination Page 4 of 8 Whilst the Applicant says that it was getting dark on the evening of the handover and he did not have a chance to go through the external checks of the house, the Applicant has suggested that the driveway was covered in debris from the fire and the builders were present over a 17 month period. This suggests that the stains occurred during the period immediately after the fire and during the 17 months of repairs. It is not unreasonable to assume that the Applicant would have attended at his home during the repair period and if there were stains on the driveway, he would have observed the stains during that period. In those circumstances, it is hard to see why the Applicant waited until 7 April 2014, over a month after the handover, to bring the stains to the attention of the FSP. In the circumstances and on the balance of probabilities, I am not satisfied that the Applicant has met his onus to establish that the stains to the driveway were as a result of the fire event, or the actio ns of the FSP’s builders when carrying out repairs. Floating floor installed without levelling The Applicant says that the floating floor needs to be removed and reinstalled as it is not level. On the other hand, the FSP maintains that the flooring has been checked with a spirit level in the Applicant’s presence and there were no issues. The Applicant has provided a report from what he says is a flooring specialist, to the effect that the floor needs to be removed and reinstalled. Unfortunately, I have concerns regarding the qualifications of the flooring specialist engaged by the Applicant. I note that prior to the preparation of the Recommendation, the flooring specialist was asked for details of his qualifications. These were not provided. I note that the FSP wrote directly to the flooring specialist, requesting details of his qualifications in order to provide the report. A copy o f this request has been provided to the Applicant and the Applicant was aware that the FSP had requested these details. Within the Recommendation, the Case Manager has specifically questioned the absence of any information regarding the experience and qualifications of the flooring specialist. However, within the further submissions from the Applicant, post the Recommendation, the Applicant has failed to provide the details of the experience and qualifications of his flooring specialist. All evidence presented needs to be looked at in terms of what weight or reliance can be placed upon that evidence. Case No: 362158 Determination Page 5 of 8 Whilst the opinion of an expert is nothing more than an opinion, it is generally based upon experience and qualifications, which if demonstrated mean that weight and reliance can be placed upon that opinion. The question of the experience and qualifications were specifically raised with the Applicant regarding the flooring specialist, but the Applicant has not provided those details. In the circumstances an d given the FSP’s evidence to the effect that the flooring was checked with a spirit level in the Applicant’s presence and given the absence of details regarding the experience and qualifications of the Applicant’s flooring specialist, I am not satisfied that the Applicant has met his onus to establish that there is a problem with the flooring which relates to the insured event. Other Issues Originally, the Applicant had raised issues regarding the plumbing to the new fridge, the air conditioning and warranty documents apparently missing in respect to various electrical and plumbing works. Within the Recommendation, the Case Manager has rejected the Applicant’s arguments in respect to these three matters. Within his further submission, the Applicant has not responded to the Recommendation in respect to these three matters. Having viewed the evidence presented, I accept the FSP’s argument to the effect that the terms and conditions of the policy do not require the FSP to arrange for the installation of his new refrigerator. Further, I have noted the report from the air conditioning company to the effect that the air conditioning unit is working correctly and that any faults had been due to operator error. There is no evidence to challenge this view and given the Applicant has not raised the matter again after the Recommendation, I accept the FSP’s submission to the effect that work in respect to air conditioning has been completed. Finally, with regard to the question of the documents for the electrical and plumbing works, I note that the evidence confirms that these documents were provided to the Applicant at the first hand over. In the absence of the Applicant further pursuing this matter, I accept the FSP’s submission that they have complied with their obligations under the terms and conditions of the policy, in this regard. 2.2 Has the FSP met its obligations under the terms and conditions of the policy? Having considered all of the evidence and the submissions by both parties, I am satisfied that the FSP has met its obligations under the terms and conditions of the policy. Case No: 362158 Determination Page 6 of 8 Temporary accommodation Given my finding that the FSP has met its obligations under the terms and conditions of the policy, I am not satisfied that the FSP should be required to pay any further temporary accommodation. Compensation The Terms of Reference of the Service provide that in the circumstances where there has been an unusual degree or extent of physical inconvenience, time taken to resolve the situation or interference with the Applican t’s expectation of enjoyment or peace of mind, the Service may decide that the FSP compensate the Applicant for non-financial loss. I am satisfied it is only appropriate to make such a compensation award , where there is a failing on the part of the FSP in respect to its responsibilities and obligations to the Applicant, under the terms and conditions of the policy. Whilst the repair process has taken a lengthy period of time, this is substantially related to the seriousness of the fire event which destroyed the upper portion of the Applicant’s home and caused significant damage to the lower portion. Whilst there have been delays, I note that the delays have occurred for a variety of reasons, including the time it took the Applicant to sign the contract and the time it took the local council to approve the construction. Whilst there is no doubt that this has been a stressful period for the Applicant, I am not satisfied that it is appropriate that compensation be ordered in the circumstances of this dispute. Case No: 362158 Determination Page 7 of 8 3 Supporting information 3.1 Financial Ombudsman Service Approach It is an accepted principle of general insurance law that an insured bears the onus to show, on the balance of probabilities, that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. 3.2 Relevant policy provisions “ Temporary accommodation for home owners If a listed event causes loss or damage to your home and we agree you can’t live in it and you need to move out so it can be repaired or rebuilt. Covered under Buildings Insurance costs for temporary accommodation that we agree are reasonable and appropriate for you, your family and your pets that you normally keep at your site . ” 3.3 Terms of Reference Paragraph 9.3 9.3 Other compensation … b) Subject to paragraph 9.3 c) and paragraph 9.7, FOS may decide that the Financial Services Provider compensate the Applicant for non-financial loss but only where: (i) an unusual degree or extent of physical inconvenience, time taken to resolve the situ ation or interference with the Applicant’s expectation of enjoyment or peace of mind has occurred; … The maximum amount of compensation for non-financial loss will be $3,000 per claim made in the Dispute. 3.4 External reports Record Key points FSP’s builder (C) Email 13 September 2012  Roofer found old faulty repairs to sarking under area of downpipe spreader – needs to be resarked .  Some of the lead flashing under the spreader has been incorrectly installed. It is overlapping the wrong way which is pushing wat er into and over tile watercourse and then through faulty sarking. FSP’s roofer ( S ) Undated report inspection 15 April 2012  Swiss tile generally are not good having excess water on, as in the case of the downpipe spreader spilling onto the back section – this is a point of (water) ingress .  Lead step flashing all around the back side of the building has all been lapped incorrectly and has been glued unusually and is not good workmanship . Case No: 362158 Determination Page 8 of 8  Roof is unsarked too but they have put a little square of sarking underneath tile but then there are holes in the sarking. They have then put lead over the top of the tiles to try to stop it, the way they have put the lead on is pretty unsuccessful and been done to a low standard . Applicant’s flooring specialist ( H ) Ema il 26 June 2014  Laminate boards are lifting near first bedroom and landing downstairs, due to inadequate gaps along the perimeter of the room .  Seems to be excessive variance in the subfloor in certain areas of main bedroom a nd near entry to bedroom facing the park .  Subfloor was not levelled to required specs for an engineered floating floor to be installed over it . FSP’s email to flooring specialist (H) Email 26 June 2014  Can you also please advise your qualification in order to provide a report? FSP’s ai r conditioning tradesman (E) Undated letter  On inspection of system it was found that the unit is working correctly .  Upstairs and downstairs zones were checked and the temperature and air flow outputs tested ok.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.