Home / Financial Firm (Unknown - Insurer) / Determination 360460
Determination 360460
Claim declined for tiling as excluded building defect
Summary
Applicants claimed for tile and skirting damage after a fish tank overflow. The FSP accepted the claim, then declined the tiling as a building defect and withdrew its $5,800 settlement offer. AFCA found the overflow was the dominant cause and ordered reassessment and payment of the tiling.
Where the overflow was the dominant cause of loss rather than an excluded building defect, the exclusion does not apply, and the FSP was not entitled to withdraw its offer.
Issues
- Claim denial primary · upheld
“The loss does not arise from a cause specifically excluded from cover under the policy.”
- Poor claim handling secondary · upheld
“It is not appropriate to withdraw the offer of settlement in the circumstances of this matter; the Applicants were prejudiced by the change.”
Subjects and remedies
home or building damagepay claimreassess claim
Text of the determination
Determination
General Insurance - Domestic Insurance - Residential Strata Title - FSP Decision -
Denial of Claim - Exclusion/Condition
Determination
Case No: 360460 Determination Page 1 of 7
Case number : 360460 13 January 2015
1 Overview
1.1 Dispute
The Applicants hold a strata insurance policy underwritten by the Financial
Services Provider (FSP) for which a claim was lodged in August 2013 in respect
of damage sustained to the building.
The Applicants says the damage arose as a result of an overflowing fish tank
which has caused damage to the tiled areas and skirting boards of the home.
The FSP accepted the damage to the skirting boards, however, denied to cover
the damaged tiling on the basis this was not caused by the claimed event, but
rather; arose as a result of a building defect which is specifically excluded under
the terms of the policy. The Applicants dispute that decision.
1.2 Issues and key findings
Was the FSP entitled to decline the claim?
The FSP was not entitled to decline the claim because:
The Applicants have discharged the onus on them to establish a valid claim
under the policy.
The loss does not arise from a cause specifically excluded from cover under
the policy.
Was the FSP entitled to withdraw its offer of settlement?
The FSP is entitled to withdraw its offer of settlement pursuant to Section 3.5.4 of
the General Insurance Code of Practice (the Code). It is not appropriate to do so
in this dispute.
1.3 Determination
This Determination is in favour of the Applicants.
Case No: 360460 Determination Page 2 of 7
2 Reasons for Determination
I have decided this case on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous Financial Ombudsman Service
(FOS) decisions. I have taken into account all the material submitted by the
parties. There has been a full exchange of all documents relied on to make this
Determination and each party has had the opportunity to address any issues
raised by the other.
This dispute has not been the subject of a FOS Recommendation. Due to its
nature, it was appropriate to proceed directly to a Determination in line with the
Operational Guidelines to the FOS Terms of Reference.
There has been conflicting expert opinions provided as to the cause of damage to
the tiles. This is often the case when expert evidence is provided by parties to a
dispute. I am satisfied that each expert was appropriately qualified and
experienced to comment in this matter. I accordingly must take into account these
opinions but ultimately must make a decision after weighing all the evidence
before me.
2.1 Was the FSP entitled to decline the claim for the tiling?
The onus rests with the Applicants to establish a valid claim under the
policy
The FSP’s policy is an accidental damage policy which is subject to certain
exclusions. The onus rests with the policyholder to establish that they have
suffered a loss which is covered by the terms of the contract. Once the Applicants
have discharged this onus, it then shifts to the FSP to demonstrate that one or
more of the listed exclusions operate to defeat the claim.
The FSP agrees it originally accepted the tiling under the policy and was in the
process of arranging repairs for same, when it determined an error had been
made in accepting this aspect of the claim and withdrew its offer of settlement
based on an exclusion clause in the policy.
The policy specifically excludes coverage for the cost of repairing or replacing
building defects or faults or fixing building design problems.
The nature of the property and the damage claimed
The Applicants ’ property was a three storey building estimated to be 25 year old.
The Applicants had a fish tank, situated in the first floor dining room. It overflowed
and then flowed around the open plan first floor and eventually down to the
ground floor.
A short period later, following some hot weather, the Applicants noticed tiles lifting
in the dining room, kitchen and study. The Applicants assert this was the
consequence of the overflowing fish tank.
The FSP’s expert evidence is that the tile distress has arisen as a result of poor
building practices whereby the tiled areas were not equipped with appropriate
Case No: 360460 Determination Page 3 of 7
expansion joints. The FSP argues that the damage arose from causes specifically
excluded from cover.
The evidence supplied supports the Applicants' position
The Applicants have provided an expert opinion in a report from engineering firm
“ J ” . J concluded that the overflowing fish tank was the main factor in the loss
occurring. J did not consider the tiled area was required to have expansion joints
fitted, as these are recommended only for areas over 6m² as per the relevant
Australian Standard.
On the other hand, e ngineering firm “D” inspected the damaged building at the
instruction of the FSP. D concluded the damage had arisen as a result of the lack
of appropriate expansion joints in the tiling to allow for movement and expansion
of the tiles. In particular, D notes that the tiled area is continuous throughout the
floor, an area of approximately 55m² of tiling.
Where there are two competing expert opinions tendered as to the cause of the
damage, the evidence must be considered and appropriate weight accorded to
the reports in order to reach a decision as to which scenario is, on balance, more
likely.
In weighing these opinion I must take into account the surrounding circumstances.
Photographic evidence and a floor plan layout tendered by D demonstrate that the
distress is widespread throughout the floor and not isolated to the immediate
location of the fish tank. This is consistent with the Applicants ’ evidence as to the
extent of the overflow from the fish tank.
I must also take into account the fact the FSP initially accepted the claim after an
inspection by an assessor. It would appear that there was a scope of work
prepared which included repairing of skirting boards and replacing of tiles to which
the parties agreed. The FSP is entitled to alter its decision if an error is discovered
but it is of some significance that an assessor was satisfied with the cause of the
damage at the time of the claim.
There is no persuasive evidence before me that there was a problem with
distressed tiles prior to this incident and it seems coincidental that there would be
lifting of the tiles after the fish tank overflow.
According to the Wayne Tank and Pump Co Ltd v Employers Liability Assurance
Corporation Ltd 1 where there are two concurrent causes of a loss where one is
subject to cover and the other is not, an insurer is not liable for the loss. However,
the judicial authorities have long recognised the causes must be of rough
equivalence. Mansfield J, in Elilade’s Case 2 quoted the following from
Countrywide Finance Ltd v State Insurance Ltd 3 per Hammond J:
“It appears that the principle then is this: if there is a dominant cause of the loss, then
the court will have regard to that. But if there are two approximately equal, or, I would
1 [1974] QB 57
2 [2002] FCA 909
3 [1993] 3 NZLR 745
Case No: 360460 Determination Page 4 of 7
say co-mingled causes, the insurer can effectively rely on one of those causes not
being within the policy.”
On balance, I am satisfied the dominant cause of the damage was the water
overflowing from the fish tank and not incorrect building practices or faults at the
time of construction, whereby the area was not equipped with appropriate
expansion joints.
Accordingly, such a loss is not excluded by the terms of the policy and the FSP is
not entitled to decline this aspect of the claim.
The FSP has offered settlement in the sum of $5,800 in respect of the damaged
skirting boards and flooring from this incident. The FSP should reassess the cost
of repairing the skirting boards and replace all tiles in accordance with the original
scope of works, together with any tiles that have been affected by the delay in the
finalisation of this claim.
2.2 Was the FSP entitled to withdraw its offer of settlement?
The FSP is entitled to rectify an error made
The Code (Section 3.5.4) provides that an insurer may remedy an error it
identifies it has made in dealing with the claim. Accordingly, the FSP's decision
can be in accordance with the provisions as set out in the Code. It is not
appropriate to do so in the circumstances of this matter.
The Applicants state that the delay in providing them with a claim decision led to
further damage occurring as additional tiles tented, became drummy and cracked
whilst they were continually walked over.
In this instance, the conflicting information provided to the Applicants was not an
ideal situation, especially given the time taken by the FSP to change the decision.
I am satisfied there is evidence the Applicants were prejudiced by the FSP
changing its attitude as to meeting the claim.
It is for this reason that I find that the FSP should cover the cost of the
replacement of tiles that have become drummy or lifted during the course of the
claim.
Case No: 360460 Determination Page 5 of 7
3 Supporting information
3.1 Expert Reports
Record Key points
FSP’s expert (D)
Engineer's Report
07 Jan uary 2014
the dwelling is a corner strata with the frontage facing east,
which is a three story split level property
the ground floor is concrete slab on ground with load
bearing full masonry brickwork, the first floor is suspended
concrete s lab with brick veneer walls and the second floor
is timber framed flooring and brick veneer walls
the property is estimated to be around 25 years old
around six months ago the fish tank in the dining room
overflowed whilst being refilled
the insured advise d the water flowed around the open plan
first floor ; it eventually flowed down the staircase to the
ground floor
shortly afterwards the uplifting of tiles was observed in the
dining room as well as the kitchen and study
the first floor consists of tiled op en plan living areas
the floor had been consistently tiled with no obvious
expansion joints
the floor tiles were measured to be 600mx600m thick and
at some locations the grout joints were less than 1mm thick
there were swollen MDF skirting boards around the kitchen
areas
the skirting boards had been installed over the tiles
the tiles in the first floor area have de - bonded resulting in a
cavity/hollow space between the tile and substrate with a
“drummy” sound when tapped
the overflow from the fish tank is unlikely to be the cause of
the distress
the tile drumminess extended throughout the first floor
rather than locally around the fish tank area
the distress to the first floor tiles is likely to be a
combination of structural building movements, natural lo ng
term tile growth, lack of expansion/movement joints and
potential other variants such as unsuitable substrate
preparation and inadequate application of fixative
it is usually the combined effect of two or more factors that
produces stresses of significa nt magnitude to result in the
distress observed
the existing tiles and skirting boards should be removed
and expansion joints installed in accordance with
Australian Standard AS3958
Applicant s ’ expert (J)
Engineer's Report
20 Jun e 2014
the site was visually inspected and de - bonded and cracked
tiles as a result of the fish tank overflowing were observed
the property is a three story property where the damage
was in the dining room near the fish tank
Case No: 360460 Determination Page 6 of 7
Record Key points
there were tiles tented in the hallway near the WC
a lso damaged MDF skirting board in the kitchen area and
various areas of damaged paint above the skirting boards
when tiles are subject to flood, the tiles will tent and de -
bond
porcelain tiles are impervious and water would not migrate
through it but will migrate to some degree through the
cementious grout joints which do not absorb water, and the
water travels through the grout under the tile
as the adhesive is sensitive to water, it will be loosened
and if there were voids under the tile then this might f urther
perpetuate water migration into the underlayment, which
creates a hydrostatic uplift pressure
cracking will add to the problem and will mainly be caused
by walking on the tiles afterwards
assuming the tiles had not been installed properly then
they would have tented long before
if there was no flood then they would ha ve stayed attached
the flooding was the main factor which contributed to the
failure and de - bonding
the failure was not as a result of drummy tiles as there
were other undamaged tiles de spite the existence of some
drummy tiles
structural building movements are unlikely to happen as
the building is more than 10 years old
as the tiles are porcelain they will have negligible long term
growth
as the building dimensions are small, the building will not
be subject to great stresses and those that do occur are
likely to be mainly of temperature change origins
joints in tiles are not needed if the dimensions of the tiled
area are below 9m and are only recommended where
stresses are likely to be ex treme
the joints are not needed as the building is not subject to
large temperature changes
de - bonding has occurred in small areas such as in front of
the WC which has a surface less than 2m ² where no
expansion joints were needed
FSP's Expert D
Engineer's Report
08 Jul y 2014
J's report has been reviewed and comments are as follows:
some of the points J raised were unclear in their meaning
the hydrostatic pressure head would not have been
sufficient to break the bond between the tiles and the
subs trate
hydrostatic pressure would also not be significant enough
to overcome the weight of the tiles
the extent of the distress was not confined to the
immediate area but extended throughout the floor plan
area, and damage was observed in areas at the oppos ite
Case No: 360460 Determination Page 7 of 7
Record Key points
end of the house
the concrete slab has experienced long term creep and
shrinkage movements over the duration of its life which will
have a cumulative effect on tiled surfaces especially where
there is no allowance for differential movement and
minimal width of grout joints
it is difficult to differentiate between porcelain and ceramic
tiles by sight alone and J has not detailed what methods he
used to clarify the tiles are porcelain
however porcelain tiles do experience some moisture
intake and tile growth albeit at lower rate than ceramic tiles
the first floor is open plan in nature and the tiling has been
continued across the thresholds throughout the floor
therefore although individual rooms are small the greater
floor area will experience greater distress which is
exacerbated by restraint from changes in room dimension,
small grout widths and lack of expansion joints
as such, the rooms should not be considered in isolation
AS3958 provides that intermediate joints should be
provided for internal flo ors where the dimensions exceed
6m if subject to sunlight
the tenting has occurred along the longest area, the hall,
kitchen and dining areas which is a total length of
approximately 12.7m
the continuously tiled area is measured to be
approximately 55m ² , t herefore the first floor requires
perimeter and intermediate joints as per AS958.1.