Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - Service - Delay in claim
handling
Determination
Case No: 359935 Determination Page 1 of 10
Case number : 359935 25 November 2014
1 Overview
1.1 Dispute
The Applicants lodged a claim in April 2012 against their landlord ’ s insurance
policy held with the Financial Services Provider (FSP) for cracking to their
tenanted home building that was built in 2002.
The FSP denied the claim on the basis that the damage was due to inherent
defects in the foundations of the building which resulted in differential footing
movements.
1.2 Issues and key findings
Is the FSP liable for the damage to the Applicants’ home building ?
The FSP is not liable for the damage to the Applicants’ home building because
the proximate cause of the damage:
to the right hand side of the property was inadequate footings given the soil
type, and
to the left rear of the property was from faulty design and expansion of
foundations.
These causes are excluded under the policy.
Is the FSP required to pay the engineer ’s and plumber’s costs incurred by
the Applicants?
The policy only requires the FSP to pay professional fees in limited circumstances
that do not apply in this case.
Is the FSP required to pay the Applicants compensation for non-financial
loss?
The FSP is not required to pay compensation to the Applicants for non-financial
loss because there are insufficient grounds for such an award.
1.3 Determination
This Determination is in favour of the FSP.
The FSP is entitled to deny the Applicants’ claim and is not required to pay the
professional costs they incurred or any compensation for non-financial loss.
Case No: 359935 Determination Page 2 of 10
2 Reasons for Determination
I have decided this dispute on its merits, doing what is fair in the all the
circumstances, having regard to the relevant law, good industry practice, codes of
practice and previous FOS decisions. I have taken into account all the material
submitted by the parties. I am satisfied that the documentation I have relied on
has been provided to both parties.
This dispute has been expedited to a Determination. No Recommendation was
issued.
2.1 Is the FSP entitled to deny the claim?
The policy excludes loss or damage caused by gradual deterioration and
subsidence
The policy provides cover for accidental loss or damage to the building that
occurs within the period of insurance.
However, the policy excludes cover for loss or damage caused by or arising
directly or indirectly from or in any way connected with:
gradual deterioration
structural defects or faulty design,
expansion in foundations and slabs, and
subsidence (unless it occurs within 72 hours of, among other things, liquid
escaping from a fixed pipe).
The FSP bears the burden of establishing the loss or damage falls within an
exclusion in the policy.
The proximate cause of the damage was inadequate footings given the soil
type, faulty design and expansion of foundations
The damage to the Applicants’ building takes the form of cracking to the walls,
floor tiles, skirting boards and ceilings, as well as doorways out of square with
doors not shutting properly. The damage is primarily to the kitchen, dining/lounge
room. A significant crack runs east-west across the ceiling in the hallway leading
to the bedrooms.
The tenants at the property advised that some cracks existed at the property
when they moved in approximately three years prior, but they had progressively
worsened and had become severe.
There are numerous reports from both parties in respect of the cause of the loss.
The reports ultimately identify a number of factors that ha ve caused the damage
resulting from differential movement of the footings. Those factors are:
the composition of the soil – highly reactive and uncontrolled fill
a leak in the plumbing at right side of the building, and
poor drainage at the rear left side of the building.
Case No: 359935 Determination Page 3 of 10
The difficulty is in determining the proximate cause of the loss. The Applicants
assert the FSP has not established, with sufficient certainty, that the cause of the
loss is one that falls within an exclusion. This is because there are conflicting
views in the reports as to the significance of a leaking pipe at the right side of the
property. The Applicants therefore consider a reasonable outcome is for the FSP
to bear 50% of the cost of the necessary repairs.
I have carefully considered each of the reports. I find the analysis conducted by
the FSP’s engineer “N” to be persuasive. N’s report was the most thorough. It
considered two soil tests and the plumber’s report, as well as examining the
original geotechnical report and engineering drawings for the footings design
when the home was first constructed.
I accept N’s conclusions, namely:
Movement damage to the building appears to be the result of differential
footing system movements.
The level survey indicates that the right side of the slab has subsided, in
particular at the rear of the buildings where significant depths of fill materials
have been confirmed.
Localised patterns of heaving were also noted at the rear left corner of the
slab, where poor surface water drainage provisions were noted.
Both the fill and the natural materials have been confirmed as extremely
reactive clays.
The footings ought to have been extended down to natural materials. Had this
occurred, no subsidence due to fill settlement would be expected to have
adversely affected the footing system. This is an inherent defect in the original
founding of the footing system.
While it is apparent that N was unable to be definitive in its views, on the balance
of probabilities I conclude that the proximate cause of the loss and damage is
inadequate footings given the composition of the soil (highly reactive and
uncontrolled fill).
This has affected the right hand side of the property.
The left rear of the property has suffered from “heave” as a result of water
ponding in this area. The recommendations by N for rectifying this problem
illustrate that the design of the property is flawed. No damage is specifically
identified as being caused by the “heave”.
The leaking pipe is not the cause of the damage
In respect of the leaking pipe, I also accept N’s findings that:
The damage to the pipework was likely caused by the settlement of the filled
foundation material and the leakages should be considered as a symptom of
the foundation movement rather than a cause.
The effects of the plumbing leak are not significant in relation to the overall
movement that has occurred.
The level survey information indicates a general subsidence of the right side
of the house, however it does not indicate any localised subsidence which
would be expected from such a leak.
Case No: 359935 Determination Page 4 of 10
I agree with N’s conclusions that the breakage to the pipework is a symptom of
the foundation movement rather than its cause.
The policy exclusion for structural defects, faulty design and expansion
applies
The FSP has therefore established the application of the policy exclusion for
damage to the right side of the building caused or arising from “inherent defects,
structural defects or faulty workmanship of design”.
In reaching this conclusion I have considered the Applicants ’ submission that they
consider it unlikely that the experienced builder / developer responsible for the
development of the houses in their cul-de-sac would have made such an error or
that a certificate of occupancy would have been issued had this been the case.
Even in the event the footings and the fill were not the cause of the subsidence,
but rather the leaking pipe, such subsidence has occurred over a significant
period of time and would therefore not be covered by the policy (as it did not
occur within 72 hours of the pipe leaking). While the leak was under a concrete
slab (and the Applicants say they were therefore unaware of it), the Applicants
were aware of the damage from early 2011 and the condition of the property has
continued to deteriorate over the years.
The FSP has also established that the heave of the concrete slab at the left rear
of the building falls within the exclusion of faulty design of the property and
expansion of the foundations. In any event, it is not apparent from the information
before me that the building has suffered any damage as a result the “heave” at
the left rear of the building (as opposed to the damage caused by the subsidence
of the right side of the building).
Accor dingly, the FSP is entitled to deny the Applicants’ claim.
2.2 Is the FSP required to reimburse the Applicants for the engineer’s
and plumber’s costs ?
Professional fees are only payable if incurred for repairing the building
The policy provides that the FSP will pay specific professional fees and incidental
costs incurred, with its consent, in the process of repairing, replacing or rebuilding
the damage to the building.
The payment of professional fees will only be made in circumstances where a
claim for accidental loss or damage to the building is accepted by the FSP.
Professional fees incurred by the Applicants are not payable
The Applicants say that in December 2012 (after incurring engineer B’s fees and
plumber T’s fees) the FSP’s loss adjuster, CL, agreed that the FSP should
reimburse these costs to them.
However, the FSP is not required under the policy to reimburse the Applicants for
these fees given they were not obtained:
Case No: 359935 Determination Page 5 of 10
with the FSP’s consent
in the process of repair (or replacement or rebuilding of the damage)
for estimates, plans and specifications, applications for building or
construction consents, quantities, tenders or supervision, or
in relation to damage for a claim the FSP accepted.
Accordingly, there is no requirement under the policy for the FSP to reimburse to
the Applicants the costs of the reports from B and T.
Further, there is no apparent evidence to sup port the Applicants’ contention that
CL agreed in December 2012 that the FSP would pay these costs. Even if it were
accepted that CL did so advise the Applicants, the Applicants have not suffered
any prejudice from any such advice because by December 2012, they had
already incurred the costs of B and T’s reports.
2.3 Is the FSP required to pay the Applicants compensation for
non-financial loss?
The Applicants are unhappy with the length of time it has taken for the FSP to
decide the claim.
Under paragraph 9.3 of its Terms of Reference, the FSP can be required to pay
up to $3,000 compensation for non-financial loss, but only in circumstances where
an unusual degree or extent of physical inconvenience, time taken to resolve the
situation or interference with the Applicants ’ expectation of enjoyment or peace of
mind has occurred.
After considering the submissions from the parties and the timeline for the FSP’s
management of the claim (and noting that the process involved the
commissioning of multiple tests and repor ts), I am satisfied that the FSP’s conduct
was fair in all the circumstances and that there are no grounds for the award of
any compensation for non-financial loss. This was a difficult claim with multiple
experts providing differing views. This is best illustrated by the seven party
meeting at the premises on 17 December 2012. Ultimately, the FSP was correct
in persisting in identifying the proximate cause of the damage.
3 Supporting information
3.1 Policy provisions
Section 1 – Building Cover
What is covered
…
We agree to cover You for Accidental loss or damage to Your Building that occurs during
the period of insurance.
…
Case No: 359935 Determination Page 6 of 10
We also agree to cover You for Additional Benefits below.
…
What is NOT covered
We will NOT cover Your Building’s for any loss or damage that is excluded by any of the
General Exclusions (see page 26)
…
Additional Benefits
…
The costs of losses covered by the Additional Benefits numbered 1, 4, 5, 6 and 9 will only
be paid when they result from Accidental loss or damage to Your Building covered and
accepted by Us under Section 1.
…
5. Professi onal fees
Fees and incidental costs reasonably and necessarily incurred by You (with Our prior
written consent) of architects, surveyors, consulting engineers and lawy ers for:
Estimates
Plans and specifications
Applications for building or construction consents
Quantities
Tenders and
Supervision
in the process of repairing, replacing or rebuilding the damaged portion of the Building.
However, We will not be liable for the costs of preparing any claim under this Policy or any
other policy.
…
General Exclusions
This policy does not cover any loss, damage, liability, compensation, payment, cost, fee or
expense caused by, arising directly or indirectly out of, or in any way connected with:
…
4. Any gradual deterioration, depreciation, wear and tear, rust or corrosion.
…
13. Inherent defects, structural defects, or faulty workmanship of design.
14. Settlement, shrinkage, vibration or expansion in buildings, foundations, slabs, walls,
payments or driveways.
…
32. Erosion, landslide or subsidence unless the loss or damage occurs within 72 hours of,
and is caused by:
An earthquake or ex plosion
a Storm
Case No: 359935 Determination Page 7 of 10
liquid escaping from a fixed pipe, or an object attached to a pipe, fixed gutter, fixed
tank or drain.
3.2 Key events and reports
Record Key points
21 December 2009
Applicants ’ plumber
“AH”
Tax invoice states “cleared broken sewer drain on house, out
front garden area, full of tree roots, drain is cracked at 1.6
metres down in ground, blocking up the whole house.”
cost of repairs was $169.40
The Applicants state the work was completed.
AH confirmed that he recalls the repairs, he has attended the
property a few times to clean up the roots but that the broken
pipe was not replaced.
AH considers the br eakage to be approximately 1 metre from
the front boundary line and is 1.6 metres below the ground level.
The pipe is not in the proximate area of the house.
This is ultimately accepted by all parties.
6 January 2011 Applicants made aware of possible ho use movement by
property manager.
16 May 2011 Policy incepted
5 January 2012 Applicants again made aware of house movement by property
manager.
7 February 2012
Applicants’ plumber
“T”
Plumbing test cost $484
Drains failed both the “underslab and main house drain test” as
well a “stormwater test”. There were tree roots entering the
drain indicating it had been broken for some time.
The breaks are on the right hand side of the property.
Doubt is later cast abo ut this report given AH’s belief that the
plumbing is not located where T says it is and also because
there were no other inspection sites AH could find to verify T’s
findings.
11 April 2012
Applicant s ’ engineer
“B”
Visual inspection of property occurred on 17 February 2012 at a
cost of $1,375.
A soil test was undertaken on 12 March 2012 showing highly
reactive clay and uncompacted fill material. The soil tester also
noted that the house drained to the “right / rear.”
A level survey showed maximum differ ence of 66mm, the lowest
recorded was along the right hand side of the building.
Poor drainage conditions were noted around the building.
Movement was related to a combination of moisture changes in
the reactive clay and inadequate founding material used during
construction, being influenced by the leaking pipes.
The defects observed at the site inspection indicate the original
Case No: 359935 Determination Page 8 of 10
Record Key points
construction and design of the footing system may be poorly
suited to the site.
B made a number of recommendations to mitigate t he damage.
16 April 2012
Applicants’ quote
Quote for $23,914 to repair the damage, excluding some listed
costs.
24 April 2012 Applicant lodged claim
4 June 2012
FSP’s loss adjuster
“CL” report 1
Identified damage
Notes that B does not clearly identify whether or not the leaking
water services are a direct cause of the change in moisture
content or whether the leaking water services have been
damaged by the movement of the building.
CL has the impression that the c ontinuous changes in moisture
content within the reactive clay soil with the inadequate founding
materials of fill used when the building was constructed were
the most prominent causes of the damage.
21 June 2012
CL report 2
B was requested to clarify th e cause and effects of the leaking
water issue.
17 July 2012
CL report 3
B clarified the water leaks from the household plumbing most
probably caused the movement of the building and resultant
damage.
The leaks will have flushed loose filled material away from the
leak to cause observed settlement which is confirmed by levels
taken by the engineer onsite and also by soil testing identifying
fill around the leak area.
Since the leaks have occurred around the fill area, it is more
likely that the leaking wa ter services have caused the
movement and not the other way around.
There was no way to provide a definitive answer. It is not just
movement related to moisture that caused the damage, but
rather movement relating to the flushing away of loose fill
materi al due to water leaks in the fill areas.
Further information was required to determine the history of
when the problems were first reported.
August -
September 2012
CL report 4 – 6
FSP tried to determine what damage was known in 2009 and
what repairs were carried out particularly in respect of the
cracked drain.
24 September 2012
CL report 7
No repair work had been undertaken since first identified in
2009.
Tree roots may be the proximate cause of the breaking pipe.
3 January 2013
CL report 10
Seven parties met at the property (although no one had
arranged access to the site which was tenanted) on 17
December 2012.
AH advises the sewer inspection point was about 2 metres
below building floor level and that the waste dispersal pipes
Case No: 359935 Determination Page 9 of 10
Record Key points
(including th e one containing the broken pipe) were even further
in ground from that point.
He has attended the property several times to clear tree roots.
Since water cannot travel uphill he considered the root
blockages and broken pipes had no direct connection and
cannot be attributable to any water leakages that may affect the
building. All parties agreed.
There was also reason to question T’s report.
CL recommends an independent engineer and plumber be
engaged.
5 February 2013
FSP’s e ngineer “N”
– report 1
The level contour information indicates that the footing system
has suffered subsidence at the right side of the house and
localised heaving of the rear left corner of the house.
Significant depths of uncontrolled fill had been identified on the
site, in particular at the right side of the house. This correlates
with the location of the lowest levels measured across the floor
slab.
The most likely mechanism of movement of the footing system
is the consolidation settlement of the fill materials. Given the
patterns of movement recorded in the level survey, it appears
highly probable that the footing system does not extend into the
natural materials.
The slab levels indicate a more general subsidence of the right
side of the house, rather than localised subs idence in the
immediate vicinity of the location of the leak.
Any leakages from broken plumbing were likely caused by the
settlement of the fill materials and should be considered as a
symptom of the movement rather than a cause.
The primary cause of the subsidence is a likely inherent defect
posed by the original founding of the house on the inadequately
compacted fill materials.
During periods of heavy rainfall, water is able to pond around
the rear left corner of the building, which can contribute to the
heaving of the slab in this area.
4 March 2013
FSP soil tester “AP”
The site is classified “P” due to poor bearing capacity, the depth
of uncontrolled fill and abnormal moisture conditions.
The soil is extremely reactive.
The test holes each showe d “very moist and uncontrolled.”
19 April 2013
N – report 2
The soil testing confirmed the presence of significant depths of
fill materials overlying extremely reactive natural clays across
the site.
In the absence of relevant certification, the fill cannot be relied
upon as having been controlled. This is even though the
original geotechnical report (27 March 2001) stated “it is
understood that the fill has been certified as having been placed
in a controlled manner under level 1 supervision, and is suitable
for the support of high level footings.”
The footing system appears to rely on the fill as suitable
Case No: 359935 Determination Page 10 of 10
Record Key points
foundation materials.
The footing design does not meet the requirement for a class E
site.
The footings ought to have been extended down into nat ural
materials. Had the footings been founding into natural materials,
the subsidence currently evident would not be expected to have
occurred.
The plumbing leak appears to be a symptom of the initial
settlement of the fill, and not a cause of movement. T he level
survey indicates a general subsidence of the right side of the
building, rather than a localised subsidence which might be
caused by leaking moisture into fill materials.
Further leaking moisture into extremely reactive clays would be
expected to cause upward heaving, rather than subsidence.
Given the foundational material present and footing system
design details, the effects of the plumbing leak are not
significant in relation to the overall movement that has occurred.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.