Home / Financial Firm (Unknown - Insurer) / Determination 358448
Determination 358448
Claim denial
Summary
The Applicant's strata unit suffered cracking from moisture-driven ground movement and the FSP denied the claim. AFCA found the earth movement, subsidence and seepage exclusions applied, so the FSP is not liable and nothing is ordered.
Broadly drafted earth movement and normal settling exclusions applied to damage connected with excessive groundwater, so the FSP was entitled to deny the claim.
Issues
- Claim denial primary · not upheld“The FSP is not liable for the damage to the Applicant's unit; the earth movement and seepage exclusions apply.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
General Insurance - Domestic Insurance - Residential Strata Title - FSP Decision -
Denial of claim
Determination
Case No: «reference_id» Determination Page 1 of 5
Case number : 358448 6 October 2014
1 Overview
1.1 Dispute
The Applicant owns a double storey unit in a residential development, which is
insured under a residential strata insurance policy issued by the FSP and held by
the owners’ corporation.
In December 2013, the Applicant notified the owners ’ corporation of cracking and
movement damage to his unit and the owners ’ corporation lodged a claim under
the policy.
The FSP denied the claim on the basis that the damage was caused by seeping,
normal settling and earth movement, each of which is excluded under the policy.
1.2 Issues and key findings
Is the FSP liable for the damage to the Applicant’s unit ?
The cracking and movement damage to the Applicant’s unit occurred as a result
of earth movement caused by excessive moisture in the surrounding soil due to
the effects of groundwater and/or surface water run-off. The policy excludes cover
for damage caused in this manner.
1.3 Determination
This Determination is in favour of the FSP.
The FSP is not liable for the damage to the Applicant’s unit .
Case No: 358448 Determination Page 2 of 5
2 Reasons for Determination
2.1 Is the FSP liable for the damage to the Applicant’s unit ?
Application of policy depends on cause of damage
The strata title policy provides cover for accidental damage to the Applicant’s unit,
being damage caused by any sudden or unexpected or unforeseen occurrence
which is not otherwise excluded under the terms of the policy.
The policy contains general exclusions for damage that arises directly or indirectly
out of, or is in any way connected with:
erosion, subsidence, earth movemen t or collapse ( unless caused by an
earthquake ; or
normal settling, seepage, shrinkage or expansion in buildings, foundations or
walls.
It is an accepted principle of general insurance law that an insured bears the onus
of establishing that, on the balance of probabilities, they have suffered a loss
caused by a risk insured under the policy. This is known as a prima facie claim. If
the insured is able to establish a prima facie claim, the onus then shifts to the
insurer to show that, on the balance of probabilities, the loss falls within an
exclusion clause under the policy or that it is otherwise entitled to deny liability.
The expert reports establish that the Applican t’s unit has suffered movement and
cracking damage. In these circumstances, given the broad cover for accidental
damage under the policy, the Applicant has established a prima facie claim.
As the FSP is seeking to rely on a policy exclusion to deny the claim, it bears the
onus of establishing that, on the balance of probabilities, the relevant exclusion or
condition applies.
Damage was caused by earth movement due to excessive moisture
The available information establishes that the cracking and movement damage to
the Applicant’s unit was caused by differential movement of the foundations due
to excessive moisture in the soil under and around the building.
The engineer (M) appointed by the FSP to determine the cause of the damage
concluded that the excessive moisture in the soil was the result of groundwater
flows. M noted that:
the Applicant’s unit was located at a low point in the surrounding area and was
subject to a significant amount of groundwater flow from higher ground, as
evidenced by the fact that holes dug by the Applicant to monitor the situation
contained water even when there had been no recent rain;
the soil at the front of the property was higher than the surface soil in the sub-
floor area at the front of the unit, which resulted in moisture seeping through
the sub-floor brickwork;
the layer of clay at a depth of approximately 1 metre acted as a water seal
creating a perched water table, which resulted in groundwater flowing through
the sandy layers above; and
Case No: 358448 Determination Page 3 of 5
given the nature of the foundation materials, excessive moisture would cause
settling of the soil due to vibrations transmitted through the foundations from
the unit above.
In his report and subsequent emails, M confirmed that the moisture in the soil was
not the result of localised flooding or surface runoff and could not be attributed to
any particular storm event. Based on his inspection of the property, he concluded
that surface run-off could not generally enter the sub-floor area.
The Applicant has provided a report from his b uilder (A) who inspected the
property in November 2012. A’s findings are inconsistent with those of M, in that A
focussed on the flow of surface water down the sloping driveway at the front of
the unit as the main source of the excessive moisture in the sub-floor area. A
concluded that the issue could be addressed by installing appropriate surface
drainage (rather than the sub-surface drainage recommended by M).
The Applicant says that, during periods of heavy rainfall, water flows over the
wood framework under his front doorstep and the over top of brick footings, and
dams up against the front foundations. He has also provided photographs which
show staining of these areas.
Exclusions for earth movement, subsidence and normal settling apply
As outlined above, the policy excludes cover for damage that arises directly or
indirectly out of, or is in any way connected with, earth movement, subsidence or
normal settling of buildings and foundations.
While the FSP’s engineer (M) and the Applicant’s builder (A) di ffer in their views
as to the source of the excessive moisture in the sub- soil of the Applicant’s unit,
both agree that the resulting movement damage to the unit was due to differential
movement and settling of the building and foundations.
The Panel considers that, as an engineer, M is appropriately qualified to
determine the cause of the movement damage to the Applicant’s unit. M’s report
provides a logical and reasonable explanation as to how the movement damage
occurred, which appears consistent with the observed facts (including the staining
damage observed by the Applicant).
However, e ven if the Panel accepts the Applicant’s position that the excessive
moisture is due to surface water run-off, the reports and other information
provided suggest that this has occurred in the course of ordinary and usual
weather events.
In these circumstances, given the broad drafting of the relevant exclusion clauses,
the resulting damage to the Applicant’s unit is appropriately characterised as
being “connected with” ea rth movement, subsidence or normal settling of
buildings and foundations.
Accordingly, the FSP is entitled to rely on these exclusions, with the result that it
is not liable for the Applicant’s claim.
3 Supporting information
3.1 Terms of policy
Case No: 358448 Determination Page 4 of 5
Subject Terms
Accidental damage
cover
We will pay You in accordance with the applicable Basis of
Settlement if any of the Property Insured shown in the Schedule
under this Section is Damaged at the Situation by any sudden or
unexpected or unforeseen occurrence wh ich is not otherwise
excluded which occurs during the Period of Insurance .
General exclusions We will not pay for any Damage arising directly or indirectly out of
or in any way connected with: …
g. erosion, subsidence, earth movement or collapse, unless
Damage is caused by or results from an earthquake or
seismological disturbance;
h. normal settling, seepage, shrinkage or expansion in Buildings
or foundations, walls, pavements, roads an d other structural
improvements
3.2 Experts’ reports
Report Key points
Applicant’s builder
(A)
Report – 12 November
2012
There was minor cracking and movement damage in a number
of areas, which was attributable to settlement of the building.
There was evidence of minor subsidence to the footings.
The unit had considerable settlement damage to the common
wall. The settlement should be monitored for a further four
months. If it worsens, a structural engineer should be appointed
to assess the movement.
The surface water drainage at the front of the Applicant’s uni t
appears to be inadequate. Drains should be installed to divert
seepage and surface runoff water away from the building to
prevent structural damage. Agricultural drains at the rear of the
building may also be required .
FSP’s engineer (M )
R eport – 7 Janu ary
2014
The Applicant’s unit was approximately 10 years old.
The external and common party walls of the unit were
supported on concrete strip footings while the internal walls and
floor were supported on concrete stumps.
There was slight to moderate crack ing on the first floor of the
unit, which was consistent with differential movements in the
foundations.
The surface of the sub - floor soil was damp and, according to
the Applicant, gets wetter after rainfall. A hole dug by the
Applicant at the entrance to the sub - floor had water pooling.
A damaged storm water pipe in the sub - floor area had been
repaired more than 12 months previously and was unlikely to
be causing the current excessive moisture, given the nature of
the foundation soils.
Water was not pooli ng under the house and t here was no
evidence of rising damp.
The moisture in the soil is not from localized flooding or surface
runoff and cannot be attributed to any particular storm event.
The only point of entry from external surface flows is through a
Case No: 358448 Determination Page 5 of 5
Report Key points
sub - floor air vent in the front wall under the verandah, but water
would only flow through this vent during extreme weather
events.
The most likely source of the ongoing soil moisture is from
groundwater flows. The Applicant’s unit is at a low point in the
surrounding area and there is a significant amount of
groundwater flow from higher ground. This is supported by the
fact that the water level in the holes left open increases after
rainfall .
Soil tests established that the foundation material was sandy
soil, which can settle if there are vibrations in the soil or
transmitted through the foundations (for example, from sources
inside the house).
There was a layer of clay at a depth of approxim ately 950
millimetres, which was likely to act as a water seal creating a
perched water table. This meant that the groundwater will flow
in the sand layers above this clay layer.
The movement damage on the first floor was due to differential
movement in th e foundations which could be from either the
stumps or the external walls.
The soil at the front of the property was higher than the surface
soil in the sub - floor area at the front of the unit. Moisture was
therefore seeping through the sub - floor brickwork which is why
the Applicant had noticed that the timber bearer along the front
wall under the front door sill was wet at times.
This issue could be addressed by installing subsurface
drainage to limit groundwater flows entering the sub - floor area.
FSP’s engineer (M )
Emails – 25 & 26
February 2014
The excessive moisture is caused by groundwater flow and not
surface water flow (contrary to A’s conclusions about the need
for additional surface drainage).
This is apparent from the fact that the holes dug by the
Applicant were full of water when he attended the property in
January 2014, despite there having been no recent rain.
The issue has been ongoing since the breaking of the drought
in March 2010, when normal rainfall patterns resumed and
groundwater flo ws (which may have ceased during the drought)
were re - established.
Applicant’s
restumper (B)
Report and quotation –
6 August 2014
When he attended the Applicant’s property, the b rick footings
were wet and stained and the timber frame under the front door
step was stained . The soil under the unit was wet with definite
signs of mould.
The load carrying walls required restumping.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.