Home / Financial Firm (Unknown - Insurer) / Determination 356775

Determination 356775

Denial of kitchen and laundry water damage claim under wear and tear and climatic exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2014-12-11
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$21,296
SourceAFCA PDF

Summary

The applicant claimed $21,296 for water damage to kitchen and laundry floors, attributed to a dishwasher leak. The insurer denied it, and AFCA decided in favour of the insurer, finding the damage more likely caused by long-term poor sub-floor ventilation.

The applicant bears the onus to prove the loss was caused by a covered event, and the expert evidence better supports long-term humidity damage excluded by the policy.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Motor Vehicle- Comprehensive - FSP Decision - Denial of Claim Determination Case No: 356775 Determination Page 1 of 6 Case number : 356775 4 December 2014 1 Overview 1.1 Dispute The Applicant’s claim for water damage to his kitchen and laundry was denied by the Financial Services Provider (FSP) on the ground the policy excludes damage caused by wear and tear, atmospheric or climatic condition. The Applicant believes he is entitled to full indemnity of $21,296 because the damage was caused by a water leak from a faulty dishwasher approximately two and a half years prior. This dispute has not been the subject of a Financial Ombudsman Service (FOS) Recommendation. Due to its nature, it was appropriate to proceed directly to a Determination in line with the Operational Guidelines to the FOS Terms of Reference. 1.2 Issue and key findings Can the FSP deny the claimed loss? The FSP can deny the claimed loss because:  There is insufficient evidence to support the claimed damage arose from the 2011 dishwasher leak.  Available evidence is more consistent with a proposition that the damage was attributable to long term effects of poor sub-floor ventilation and a humid environment. 1.3 Determination This Determination is in favour of the FSP. The FSP is entitled to deny the claimed loss. Case No: 356775 Determination Page 2 of 6 2 Reasons for Determination I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties. There has been a full exchange of all documents relied on to make this Determination and each party has had the opportunity to address any issues raised by the other. Expert opinion as to the cause of the damage has been provided. I must take it into consideration but I am not bound by it in reaching my decision. 2.1 Can the FSP deny the claimed loss? Applicant’s onus to prove claim covered by policy The onus is on the Applicant to establish a claim under the policy in respect to the dishwasher leak. It is insufficient for the Applicant to assert the FSP should be responsible for the water damage merely because:  the FSP accepted there was a leak from the dishwasher  t he FSP’s builder’s moisture reader was inoperable at the time of his inspection  his moisture reading returned a normal reading  his plumber did not find any other leakages. The Applicant must provide persuasive evidence the damage was linked to the dishwasher leak. Applicant’s evidence is insufficient to support the view that the 2011 dishwasher leak caused the damage While the Applicant alleged that the FSP’s builder’s moisture reader was not working at the time of his inspection, photographic evidence indicates it was operating and had in fact returned a high moisture reading. The Applicant also conducted his own moisture test. Although his test results returned low moisture readings, they were taken several months later when all the floor tiles, dishwasher and cabinetry had been removed. By this stage, it was highly likely that the floorboards would have been drier because the exposed floorboard allowed for more rapid moisture e vaporation. The Applicant has provided a report from his plumber (PP) but his evidence also does not support the proposition that the damage was caused by the dishwasher leak. Whilst PP says this was the primary cause of the damage to the flooring, he has not:  R ebutted the FSP’s expert evidence , which supported that the damage to the floor tiles is attributable to long term effects of poor sub-floor ventilation and a humid environment.  Provided any plausible explanation for his conclusion other than merely stating that there was no evidence of any other leakages. Case No: 356775 Determination Page 3 of 6  Disputed that the leakage from the dishwasher was minor and therefore it would have dried out at the time of his inspection. Evidence more consistent with the damage being attributable to long term effects of poor sub-floor ventilation and a humid environment While there is no dispute that the flooring in the Applicant’s k itchen and laundry areas have suffered damage, the various reports by the FSP’s experts support the view that the damage was consistent with being attributable to long term effects of poor sub-floor ventilation and a humid environment. According to the FSP ’s building consultant (AA), the lifting of the floor tiles occurred because:  Inadequate sub-floor ventilation had resulted in high humidity existing within the sub-floor spaces under the laundry and meals area for extended periods of time, causing partial deterioration of the particleboard flooring and the floor tiles to subsequently dislodge.  T he Applicant’s ceramic floor tiles w ere glued directly onto a timber substrate inadequate installation process, as it led to bond failure (particularly in wet areas). AA came to this conclusion because:  The vast majority of water leaked from the dishwasher would have been contained in the kitchen area due to the floor levels being graded towards the west side of the kitchen.  The water leak from the dishwasher two and a half years ago would have dried completely or, at most, would return only slightly elevated moisture readings.  The moderate structural deterioration and high moisture readings taken from the particleboard surfaces suggest the moisture detected was from a recent occurrence.  Particleboard flooring containing moisture to the point of saturation over an extended period exceeding two years would exhibit severe structural deterioration and decay and offer no support to foot traffic.  There was no excessive swelling and deterioration to the particleboard, which does not seem to support the proposition that the damage was caused by the dishwasher leaking.  Floor levels throughout the house were taken, showing the highest point to be along the west side of the meals area, suggesting the water leak would have been prevented from spreading into the laundry until other areas within the home were flooded. Insufficient evidence to support damage arising from an event covered by the policy Based on the available evidence, it is more likely that the damage claimed was attributable to long term effects of poor sub-floor ventilation. As there is insufficient evidence to support the damage was caused by an event covered by the policy, the FSP is entitled to deny the claimed loss. Case No: 356775 Determination Page 4 of 6 3 Supporting information 3.1 Expert Evidence Record Key points FSP’s Building Consultant (AA) Report 30.12.2013  M inor fracturing to grout joins and loose drummy tiles were noted throughout the areas , particularly within m eals and laundry, indicating the vast majority of tiles had become dislodged .  About three floor tiles located within the l aundry door frame had become dislodged completely, exposing the particleboard flooring.  The d arkened appearance of the particleboard floor surface suggest s the existence microbial activity which in all probability also extends under other floor tiles within the general vicinity.  Moisture readings taken from the exposed particleboard surfaces returned high moisture con tents throughout.  Water inundating floor surfaces from a leak occurring to a dishwasher two and a half years ago would in all probability have dried completely or , at most, return only slightly elevated moisture readings.  P articleboard flooring containing moisture to the point of saturation over an extended period exceeding two years would exhibit severe structural deterioration and offer n o support to foot traffic.  The structural deterioration to particleboard appeared relatively moderate, suggesting the moisture detected was considered to be from a more recent occurrence.  Fl oor levels throughout the kitchen, mea ls and laundry areas were taken . A high point (datum) established to be along the west side of the meals would initially prevent water runoff into the laundry until other areas within the home were flooded to depth of approximately 13mm.  Floor levels taken along the west and east sides of kitchen were relatively leveled and appeared generally 13mm below datum .  No excessive swelling and deterioratio n ( typically a ssociated with water saturation) was evident .  Water discharging from a leaking dishwasher located along the east side of kitchen would in all probability initially pool toward the west side of kitchen.  Kitchen surfaces appeared in poor condit ion with edges of doors missing and deteriorated exhibiting evidence of widespread wear and tear.  Limited inspection to sub - floor areas showed dried ground surfaces with no evidence of water inundation.  M usty and moist odor emanating f rom sub - floor spaces suggests moisture present in areas unable to be inspected. Case No: 356775 Determination Page 5 of 6  Inspection to sub - floor spaces under kitchen area using a telescopic inspection camera shows a masonry sub structure severely restricting cross flow air ventilation.  Inadequate sub - floor ventilatio n is extremely conducive to creating a humid environment and subsequent adverse effects to sub - floor timbers and undersides of flooring particularly particle board where uptake and absorption of excessive moisture is most prevalent.  T he vast majority of wat er leaking from the dishwasher would have been contained within the kitchen area as floor levels were graded toward s the w est side of kitchen.  M oisture present s within particleboard flooring at the time of inspection would not have originated from the leaking dishwasher two and a half years ago as remaining moisture would have dried .  L ong term effects of moisture uptake in particleboard flooring will result in an increase in moisture content with irreparable deterioration imminent.  I nadequate sub - floor ventilation had resulted in high humidity within sub - floor spaces under l aundry and m eals area for extended periods of time , causing partial deterioration of partic leboard flooring and subsequent floor tile dislodging. FSP’s Assessor (C & L) Report No. 2 14.01.2014  Damage to floor tiling within the home and particleboard flooring substrate had not occurred due to the reported dishwasher leak.  F loor levels would have confined any leak to the kitchen area.  No damage to k itchen cabinetry due to water inundation was apparent and therefore any leak that had occurred had been minor.  Damage to the floor tiles is attributable to the long term effect of poor sub - floor ven tilation and damp/humid environment within the sub - floor, resulting in suspected microbial contamination.  In some sections, no air vents or provision for airflow under the residence have been fitted. Applicant’s expert (PP ) Report 5/2/2014  The damaged ti les and flooring in the kitchen was caused by the leaking dishwasher.  This was the primary reason for the damage because upon inspecting the hot/cold water supplies to the sink, they were not leaking and waste was in good condition.  Inspection of the sub - f loor, hot/cold water supplies and stormwater pipes shows that they were all in sound condition, making the dishwasher the only appliance or plumbing that had been faulty. Case No: 356775 Determination Page 6 of 6 3.2 Relevant Policy Provisions 11. Water or other liquid damage (Applicable whether you have buildings and/or contents cover) We will pay for loss or damage which results directly from the bursting, leaking, discharging or overflowing of: …  dishwashers … When we will not pay a claim under your policy 1. This policy does not cover loss, liability, injury or damage: … f) due to lack of maintenance, wear and tear, or neglect ... 2. Unless we state differently in your policy, we will not pay for: c) loss or damage caused by the action of light, atmospheric or other climatic conditions unless caused by:  lightning or thunderbolt, or  storm, rainwater or run-off; …

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.