Home / Financial Firm (Unknown - Insurer) / Determination 356331

Determination 356331

Denial of swimming pool damage claim (liner rupture, wear and tear exclusion)

FirmFinancial Firm (Unknown - Insurer)
Decided2014-12-09
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's swimming pool was damaged in August 2013 and the FSP declined the home building claim. AFCA decided there was no insured event and the liner ruptured from age and deterioration during cleaning, so the FSP correctly declined the claim.

The applicant did not establish a covered event such as a leaking pipe causing the loss, and the damage arose from wear and tear or gradual deterioration, which the policy excludes.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim Determination Case No: 356331 Determination Page 1 of 10 Case number : 356331 9 December 2014 1 Overview 1.1 Dispute The Applicant holds a home building policy with the Financial Services Provider (FSP) covering his residential property for a sum insured of $600,000. On 9 August 2013 the swimming pool at the property was damaged and a claim was subsequently lodged. After considering the claim, the FSP declined it on the basis that the loss had not arisen as a result of any event which would be covered by the policy. The Applicant disputes that decision. This dispute has not been the subject of a Financial Ombudsman Service (FOS) Recommendation. Due to its nature, it was appropriate to proceed directly to a Determination in line with the Operational Guidelines to the FOS Terms of Reference. 1.2 Issues and key findings Was the FSP entitled to decline the claim? The FSP was entitled to decline the claim because the loss did not arise as a result of an insured event. Further, the loss arose as a result of causes specifically excluded from cover by the policy. 1.3 Determination This Determination is in favour of the FSP. The FSP was entitled to decline the claim as the loss did not arise as a result of any event which would be covered by the policy. Insofar as the pool has sustained deterioration since the FSP’s decline of the claim, this cannot be attributed to the FSP. The responsibility remained with the Applicant to mitigate his exposure to further damage occurring once the claim had been declined. Case No: 356331 Determination Page 2 of 10 2 Reasons for Determination I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties. There has been a full exchange of all documents relied on to make this Determination and each party has had the opportunity to address any issues raised by the other. Expert opinion has been provided by the parties. The Applicant has provided a report from a plumber, DE, and an engineer’s report from NC, whilst the FSP has provided reports from two engineers, FC and NJ. Such opinions must be considered by me but they are not binding as I must weigh them in the context of all the evidence in reaching a decision. 2.1 Was the FSP entitled to decline the claim? The damage was not caused by an insured event The FSP’s policy is a defined events policy. Therefore, the policy only responds where the damage has been caused by one or more of the listed events, subject to any exclusions. Three of these listed events are earthquake, explosion and water damage from cracked or leaking pipes. The Applicant has, at various times, attributed the loss to one or all of these events. The Applicant has the initial onus of proving that an event covered under the terms of the policy had occurred in order to establish a prima facie claim. Once the Applicant has discharged this onus, it then shifts to the FSP to demonstrate that one or more of the listed exclusions operates to defeat the claim. For the sake of completeness, although the suggestion that the loss has been caused by either earthquake or explosion appears to have been abandoned by the Applicant, I am satisfied that there is no evidence to suggest either of those events occurred to cause damage to the property. Accordingly, this Determination will only address the issue as to whether a cracked or broken pipe caused or contributed to the damage occurring. The Applicant asserts that there is a leaking pipe in the pool surrounds, which has caused hydrostatic pressure to build up to the point where the concrete casing and inner liner of the pool have ruptured. In order to trigger the policy coverage, a clear causal link between the leaking pipe and the damage to the pool must be established. The Applicant has provided numerous photographs and a videos showing the pool, piping, water entering the pool and water gushing from a pipe, in support of his case. He also has a report from plumber DE stating the leaking pipe has caused the damage to the pool. DE’s report has been considered , however, whilst a plumber is able to comment on plumbing matters, there are limits on his qualification to comment on the structural matters in issue. Accordingly, limited weight can be placed on DE’ s Case No: 356331 Determination Page 3 of 10 report on the damage to the pool structure. DE’s report will be weighed in this light with the other evidence and, in particular, the reports of FC and NJ on file. It is accepted that FC and NJ are appropriately qualified and experienced to comment on this matter and the FSP is entitled to rely on their findings. It is of note that neither FC nor NJ attributed the failure to anything other than general wear and tear, which is specifically excluded from cover. The loss arose from causes specifically excluded from cover After considering the available evidence, the Applicant has not provided sufficient evidence to link the cracked pipe and/or its leak to the current issues which have arisen. On this basis, the Applicant has not discharged the onus on him to establish a valid claim under the terms of the policy. Engineering firm FC inspected the pool on the FSP’s instruction. FC concluded the damage had arisen as a result of the pool liner rupturing during the act of cleaning/vacuuming the pool. The liner was old and brittle and the pressure of the cleaning has caused it to rupture. FC considered there was no structural damage to the pool and it could be restored to its pre -loss condition by the fitting of a new liner. Engineering firm NJ also inspected the pool on the instruction of the FSP. NJ also concluded that the pool liner had most likely ruptured during cleaning as it had reached the end of its serviceable life. NJ was in agreement that there was no structural damage and the pool could be reinstated by the installation of a new liner. The Applicant disagrees with these findings and has provided his own engi neer’s report from NC. NC’s report has been considered as part of this review . In his report, NC does not mention the fact that the Applicant was cleaning the pool at the time the damage occurred or that the liner was said to have ruptured in the very spot that was being cleaned. This is a curious omission and it must be asked whether NC was made aware of this fact by the Applicant. On balance, it seems likely he was not. Accordingly, NC’s report can only be considered to carry less weight than FC ’s or NJ’ s as it appears likely he was not made aware of all relevant information, which may have affected his conclusions in the matter. In any event, NC has concluded that the cause of the structural failure evident at the time of his inspection, some eight months after the loss occurred, was as a result of the steel tensioning cable(s) breaking, causing the pre-cast panels to separate due to no longer being able to contain the hydrostatic pressures. NC states the steel cable(s) have broken because they were rusted out. NC does not attribute the loss in any way to a leaking pipe. On this basis, NC’s report does not assist the Applicant in establishing a valid claim under the policy terms as the FSP’s policy specifically excludes loss or damage caused by rust, gradual deterioration or wear and tear. Case No: 356331 Determination Page 4 of 10 In a later emailed addendum report, NC agrees with the Applicant that if there were a leaking pipe, this would hasten the rusting. However, it is notable that NC does not say there is a leaking pipe. Rather, he just agrees that if there were one (my emphasis), it would contribute to the rusting of the cables. Such a statement is not equivocal evidence to suggest there is in fact a leaking pipe, or that if there was one, the leak was a contributing factor to the loss. Photographs of the alleged leaking pipe taken at the time of NJ’s second inspection show the surrounding soil to be relatively dry, which is unsupportive of the Applicant’s assertion that this area is responsible for a leak. Further, NJ noted the crack was in the coupling rather than the pipe itself, making it unlikely that any moisture was escaping. No water was observed to escape from the area when water was introduced to the coupling. NJ did not consider the cracked coupling had either caused or contributed to the event and stood by their original conclusion that the liner had simply ruptured during the cleaning process, due to its age and condition. The Applicant has also not explained how a leaking pipe could fracture the waterproof inner liner without damaging the concrete pool shell. Both FC and NJ confirm that the pool remained structurally sound at the time of the respective inspections. It is difficult to see how an external event, such as a leaking pipe, could affect the liner without first damaging the concrete outer shell. Whilst it seems apparent at the time of NC’ s inspection of the pool some eight months after the loss had occurred, that there was structural damage which was evident and NC considered the pool was no longer salvageable, this is likely due to the pool being emptied of water for that period of time and the resultant changes in hydrostatic pressure and the broken cabling rather than anything related to the initial claimed event. I am satisfied that the evidence presented supports the conclusion that the damage to the pool has arisen as a result of the fracture of the liner during the cleaning process, most likely due to its age and deteriorated condition. As the policy specifically excludes loss or damage arising from any form of wear and tear or gradual deterioration, the FSP has correctly declined the claim. The pool has deteriorated after the refusal of the claim Insofar as the pool has suffered structural damage and further deterioration since the initial event occurring, such damage is not the responsibility of the FSP. The FSP informed the Applicant his claim was declined on 14 August 2013, some five days after lodgement. Accordingly, it was the Applicant’s responsibility to ensure he mitigated his exposure to further loss occurring by taking prompt remedial action to fix the pool. He did not do so and any further damage cannot be attributed to the FSP. Case No: 356331 Determination Page 5 of 10 3 Supporting information 3.1 Expert Evidence Record Key points FSP’s expert ( FC ) Engineer’s Report 23 Aug 2013  the owner reported that the liner of the pool was damaged on 9 August 2013  the insured was cleaning the pool with a handheld vacuum cleaner when he heard two loud noises consistent with an explosion  the pool shook in response to these noises and within a few seconds air injected into the pool via the north western pool filter return line  the pool water became aerated like a spa  the internal pool liner floated up and a tsunami like wave of water splashed over the northern pool wall  damage to the pool liner occurred as a result of the liner floating  the pool was reportedly constructed in 1985  it is a segmentally constructed concrete pool consisting of pre - cast concrete wall segments placed side by side and fixed with a perimeter tensioning cable  the pool has an internal PVC liner which was the original according to the owner  this places the liner as being 28 years old at the time of inspection  previous patch repairs to the liner were evident and there was a break in the liner evident at the western pool wall  the pool was partially de - watered at the time of inspection  the pool liner was found to be aged, weathered and extremely brittle, it snapped and tore apart in hand  the floor of the pool was traversed and the walls inspected visually. No significant deformations in the pool floor were identified which would lead to a conclusion the floor and wall elements had not sustained any structural damage  the pool water pump equ ipment was visually inspected and appeared to be in sound condition although it was not operational at the time of inspection. The loss adjuster had inspected it previously and found it operated satisfactorily  there was no significant damage to the pool st ructural walls or floor sufficient to cause explosion like noises  nor was there any damage to the pool that would have been caused by an explosion or shaking of the pool structure  the most likely explanation for the damage to the pool liner is aged related deterioration, which has ruptured during the cleaning process  it is possible rupture of the pool liner could have caused some release of air and modest aeration of the pool Case No: 356331 Determination Page 6 of 10 Record Key points  given the aged and brittle condition of the liner at inspection, any rupture of th e pool liner would have resulted in further rupture  the general lifespan for a pool liner is 10 - 15 years and most manufacturers warrant their pool liners for 8 years  the liner has been damaged by long term weather and pool chemical exposure which has cause d it to become weak and brittle over time  it most likely ruptured during the cleaning operation  no structural damage was sustained in the incident  the pool liner can simply be removed and a new liner fitted  the new liner should be fitted promptly so as to prevent leakage of pool water through the segmented pool structure into the surrounding soils  failure to complete the recommended repairs in a timely manner could result in structural damage FSP’s expert ( NJ ) E ngineer’s Report 09 Sep 2013  a visual inspection was conducted of the site  the pool was constructed in 1985, the base is of in situ reinforced concrete, the walls are of pre - cast concrete and bound externally with a steel tension cable, with a vinyl liner fitted internally  the liner h as been patched in the preceding five years  approximately three weeks ago the insured was undertaking routing maintenance with a hand held vacuum hose  the pool was filled to level at the time  during cleaning he heard two bangs like an explosion which caus ed a shockwave and miniature tsunami of water  the insured believes the explosion caused a shockwave bubbling of air and rupture of the liner  the insured believes the explosion may have been caused by mining activity in the area or heavy rains in the past 1 2 months  a PVC pipe was installed at the time of construction through the pool walls to allow any seepage which migrates through the pool shell to drain out  subsequent to the damage occurring, the insured observed water pouring out of the outfall  the pool filtration systems are all in working order including the chlorinator  the insured pointed out cracking to the base of the pool where water was seeping in from the ground and he believes the concrete shell has been compromised due to the pressure and this h as caused cracking which will prevent the pool from being relined  the liner had been removed at the time of inspection  there were various silicon - type patch repairs evident to the tiled section at the step outs Case No: 356331 Determination Page 7 of 10 Record Key points  minor concrete shrinkage cracks were noted to the base of the pool, with some minor seepage at the crack locations  a 50mm PVC pipe is installed through the western wall near the base which has an outfall near the house. The level of the outfall appears to be significantly higher than the inlet  no evi dence of structural distress, damage or movement was noted to the concrete pool shell  no obvious sources of combustible material or high pressure vessels or gases were noted in the vicinity of the pool  the insured advised the liner is 28 years old. Vinyl l iners typically have a useful serviceable lifespan of around 10 - 15 years and are considered a renewable component of the pool  liners become brittle over time as a result of exposure to ultra violet radiation and pool chemicals  photographs shown by the insu red show the liner was at least approaching, and possibly past, the end of its useful life  the insured advised he was cleaning the pool in the location where the liner ruptured and it is most likely that the action of cleaning and the friction from the rub bing has caused the brittle material to tear  there was no evidence of any explosion or shockwave in the vicinity of the pool  the circumstances as described by the insured would seem likely to have caused widespread damage to the pool shell and surrounds and possibly injury to the insured  an explosion would require a combustible source to be ignited or a sudden release of very high pressure. Nothing capable of causing this was noted in the vicinity  the walls of the pool are relatively rigid and robust and would not be expected to transmit any rapid externally applied forces which might create a shockwave in the pool  any bubbling up of air likely originated from one or both PVC pipes in the base of the pool, which would have filled up with water when the lin er tore  the turbulence from air bubbles and the water moving to the outside of the liner may have been sufficient to cause progressive tearing around the pool  there is some relatively minor cracking to the pool base which is normal concrete shrinkage, whic h affects most concrete structures  no evidence of significant cracking, damage or movement of the pool shell was evident or any indication it has been overstressed  the property is at least 1km away from any area influenced by mining and it is highly unlike ly the property has been Case No: 356331 Determination Page 8 of 10 Record Key points affected by mining works  the pool may be restored to its pre - loss condition by installing a new liner  any replacement liner would have a service life of approximately 10 - 15 years, after which it too would require replacement FSP’s expert (NJ) Engineer’s report 22 Dec 2013  the pipework associated with the filtration system has been exposed adjacent to the skimmer box, at a depth of approximately 300mm below ground level  the pipework is of relatively small diameter, typical of pool plumbing installations  a small crack was noted in one of the coupling pieces of the pipework  the crack appears fresh with no dirt in or around the crack  a garden hose was used to introduce water to the pipework and water was noted to flow out of one o f the water return outlets as would be expected during normal pool function  no water was noted to escape from the cracked section of pipe during the demonstration  the soil around the cracked section of pipe did not appear to be damp  it is not possible to d etermine the age of the crack , however , it is possible the crack developed sometime after the damage occurred to the pool liner  as the crack was noted in the coupling piece, it is possible the pipe remained intact and therefore may not be resulting in any moisture loss  typically, pool filtrations run between 3 - 6 hours a day which would limit the amount of water able to escape from the crack, if any  as the pool is effectively a closed system, should a significant water loss occur as a result of a leak, the w ater level would drop below the skimmer box and cease to be able to flow into the return pipework, effectively limiting the amount of water which is able to escape, unless the pool were topped up on a regular basis  the requirement to top up would be unusua l and be a signal to the owner that there was a problem. The insured advised the pool was operating normally prior to the liner being damaged  it is noted the cracked coupler is located well away from where the damage to the liner originated  even if the amo unt of escaped liquid was sufficient to trigger damage to the liner, it would not be expected to do so on the opposite side of the pool  there were no indications of any movement or damage to the pool shell having occurred which would be consistent with a b uild - up of external pressure due to water escaping Case No: 356331 Determination Page 9 of 10 Record Key points in to the backfill  the crack in the PVC coupling does not represent a viable mechanism by which the damage could have occurred to the liner  NJ stands by the original conclusion that the age d and brittle li ner failed during the process of vacuuming, which cause d a progressive failure around the pool  the pool was still able to be reinstated to its pre - loss condition by installation of a new vinyl liner Applicant’s expert ( DE ) Plumber 01 Jul 2014  there is a water leak at the back of the pool on the pump out line  the owner located the hole whi le excavating near the pool  the leak was coming from a high pressure fitting that was cracked as a result of the leak  it has run down the back side of the pool and has u pset the integrity of the pool  it caused the pool to shift and ultimately put pressure on the liner and cause it to float then rip Applicant’s expert ( NC ) Engineer’s report 16 Apr 2014  the pool is described as a module type construction built approximately 25 years ago  the structure consists of a poured in situ base and pre - cast wall panels held in place with a tensioned steel rope, and a waterproof liner  in the event that water does get underneath the waterproof liner it should drain out throu gh the relief pipe at the base of the pool  the owner advised he has only seen this happen once or twice over the life of the pool, each time has resulted in a small tear or split of the liner, which was subsequently repaired  the owner described the event w hen the damage occurred, which was similar to a small localised earthquake creating a loud noise similar to that of a car crash, creating large waves and air bubbles in the pool water  this has resulted in large rips/tears in the liner and most probably th e large extent of existing cracks in the shell  the owner conducted two experiments to show the damage  the first was pouring water down the existing pipe that feeds water to the pool returns. After pouring water into this pipe it was only a few minutes before it began to leak  the second aimed to show the extent of cracking in the floor and walls of the pool. This was done by pouring water down the back of the pool walls. After around 10 minutes water started to weep through the cracks  although further in vestigation is required, the structural event as described by the owner can only be explained by Case No: 356331 Determination Page 10 of 10 Record Key points a sudden release of stresses caused by one or more of the tensioned steel ropes breaking  as the steel has rusted, it has eventually become too weak to contain the pool’s hydrostatic pressure causing it to fail  this sudden release of stress has caused the waterproofing liner to rip extensively and without adequate tension holding the wall modules together, leaks have formed making the pool unusable

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.