Home / Financial Firm (Unknown - Insurer) / Determination 354765

Determination 354765

Denial of claim-Exclusion/condition

FirmFinancial Firm (Unknown - Insurer)
Decided2014-11-13
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicants' storm claim for a collapsed veranda was denied on the basis that no violent wind was shown and the damage arose from faulty workmanship. AFCA found no storm was established and faulty workmanship is excluded, deciding in favour of the FSP.

The applicants had the onus to prove a storm event, the evidence did not establish a violent wind, and faulty workmanship is excluded under the policy.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim-Exclusion/ condition Determination Case No: 354765 Determination Page 1 of 6 Case number : 354765 12 November 2014 1 Overview 1.1 Dispute The Applicants held a home building insurance policy with the Financial Services Provider (FSP) under which they lodged a claim for storm damage to a veranda. The FSP denied the claim on the grounds the damage was not as a result of a storm rather, that it arose from faulty workmanship which is excluded under the terms of the policy. The Applicants dispute the FSP‟s findings and seek a review of the decision to deny their claim. The Applicants are represented. For the sake of brevity, both the Applicants and their representative will be referred to as “the Applicants”. The Case Manager provided the parties with a Recommendation on the issues in dispute. The Recommendation was in favour of the FSP. The FSP accepted the Recommendation but it was not accepted by the Applicants. In the circumstances, the dispute has been referred to me for Determination. 1.2 Issue and key findings Was the FSP entitled t o deny the Applicants’ claim ? The FSP was entitled to deny the claim because:  there is no evidence a storm as defined occurred on the night of the loss  the evidence suggests the damage arose from faulty workmanship  damage arising from faulty workmanship is excluded under the terms of the policy. 1.3 Determination This Determination is in favour of the FSP. The FSP is entitled to deny the Applicants‟ claim and need take no further action. Case No: 354765 Determination Page 2 of 6 2 Reasons for Decision I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties, both before and after the Recommendation. I am satisfied that the documentation I have relied on has been provided to both parties. After the Recommendation was rejected, the Applicants made further submissions and provided further material from a building inspector, C. The FSP provided no new material but said the report from C corroborates the findings of the FSP‟s builder that the damage to the home was as a result of substandard building rather than storm damage as alleged by the Applicants. 2.1 Was the FSP entitled to deny the Applicants’ claim ? The policy provides cover for damage arising from storm In this matter the Applicants must establish on the balance of probabilities the damage was caused by a storm. If this is established, the FSP must show the damage was caused by faulty design, workmanship or because the veranda was not structurally sound. The damage was not caused by a storm as there is no persuasive evidence that there was a violent wind The Applicants made a claim on 7 October 2013 and said that “during the early hours of the morning there was a strong wind storm which caused the back outside decking on the second storey to collapse.” The Applicants have provided a daily weather observation from Nelson Bay, a weather station proximate to their home. The reading closest to the early hours of 7 October 2013 is a reading at 9am which records a wind from the South recorded at 28kmph. No wind gusts are recorded. The FSP says that the search of the BOM site at the closest weather station did not display any unusual reports of high wind in the vicinity to cause a structure the size of a veranda to fall down. And they say that no other claims were made for storm related claims on 7 October 2013. The Beaufort Wind scale can be found in the website of the Bureau of Meteorology (BOM). Item 6 of the Beaufort Scale lists Strong Winds which are winds 40-50kmph. The Scale progresses to item 11 Violent Storm where winds are 103kmph. The FSP‟s assessor was told that the Applicants were awakened by loud banging and glass breaking. The Applicants told him they then discovered a section of hand rail and a brick supporting pier had moved in the strong wind and collapsed to the ground below. The breaking glass was a table below which was shattered by the fall. Case No: 354765 Determination Page 3 of 6 The assessor attended the site on 7 October at 1pm and took photographs. The photographs show the debris referred to on the ground. But I consider the photographs do not show any other damage consistent with a violent wind. There is no sign of any other debris that would be caused by such a violent wind. Light garden furniture and pots are evident in the photographs and appear undamaged. To succeed, the Applicants must establish the damage was caused by a storm as defined in the policy. A storm is defined amongst other things as a “violent wind, cyclone or tornado”. The Beaufort Scale says strong win ds are those of 40- 50kmph. I consider a violent wind would be greater than that if not as great as a wind in a violent storm where there are winds as great as 103kmph. Even if I was to accept that there was a violent wind but that wind or gust was not detected and not recorded, I would then expect there to be more extensive damage which is not claimed by the Applicants and not seen in the photographs taken on 7 October 2013. On the material to hand, I am not satisfied that the Applicants have established on the balance of probabilities that there was an insured event – namely a violent wind which caused the damage to the veranda. The FSP’s assessor saw the veranda’s structure at the time of the loss and was best placed to comment on the workmanship The FSP says that the cause of the damage was not a storm as defined but faulty workmanship of the veranda when it was extended about a year before. This was shortly before the Applicants purchased the house. Three experts have reported on the veranda and commented upon its construction. C inspected the veranda on 21 October 2013 and admits that as most of the damaged structure had been cleaned up he couldn‟t really comment on the cause of failure. He does criticise the lack of bracing and the mortar in the bricks. In all the circumstances I do not consider his report carries the necessary weight to support the Applicants. Further neither of the Applicants‟ experts actually say that the veranda was damaged in a storm. It is not clear that the other expert relied on by the Applicants (HV) has ever actually inspected the property. But if he did, as his first report is written on 10 December 2013, he also does not have the advantage enjoyed by the FSP‟s assessor of inspecting the damage contemporaneously with the claim. It is noted that the “remaining columns” are pulled down on 10 October 2013 by the assessor and when the building was made safe the veranda was dismantled and the new floor joists removed. In all the circumstances I am persuaded on the balance of probabilities that if the veranda was damaged in a storm (and I do not accept this is established) that the faulty workmanship identified by both C and the assessor operate to defeat the claim. Case No: 354765 Determination Page 4 of 6 3 Supporting information 3.1 FOS Approach It is an accepted principle of general insurance law that an insured bears the onus to establish on the balance of probabilities that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. 3.2 Extract Policy documents Storm If loss or damage is caused by a storm …….. Covered violent wind, cyclone or tornado We don't cover loss, damage, injury or death arising from: faulty design or workmanship ….. you not maintaining your home in good repair and condition. This means your home must be watertight, structurally sound, secure and well maintained. 3.3 Expert evidence Report Findings BOM report at the location of the Applicants‟ property on 7 October 2013  The search area is calculated at a 50km radius  No reports or observations of strong winds – that is sustained winds above 50km/h or gusts above 90km/h  It is possible that some strong winds are not detected because no reports are received  Terrain may cause localized wind gusts stronger than those detected by the “sparse observation network.” And the gusts may not be recorded or identified as many stations o nly record wind speeds on an hourly basis BOM daily weather observations  Winds at 9am 7 October 2013 S 28km/h AG‟s report 7 Oct 2013 and emails 10 February 2014  The Applicants said the veranda was damaged in a high wind in the early hours on 7 October 2013  AG inspected and photographed the veranda on 7 October and pulled down remai ning columns on 10 October 2013  The Applicants informed him the verandah was built approximately 12 months ago s hortly before they purchased it Case No: 354765 Determination Page 5 of 6  The damage was caused by poor construction methods which allowed the verandah to move in windy conditions  The floor joists were spaced at 600mm centres whereas to accommodate the pine decking they should be at 450mm centres.  There is no lateral strap bracing to the jois ts to prevent si deways movement  The timber handrails were installed using thin plastic plugs instead of masonry anchors.  The timber handrail slats have been nailed instead of being screwed  The original veranda may have been cantilevered and then extended about 12 - 14 months ago with new floor joists bolted to the existing protruding floor joist (see photos). The brick piers were put up then too  Original veranda was built to Standards but the extension was not  AG reviewed the report from HV and said HV would have seen t he remaining original floor joists and not the new extended work as when it was made safe, the veranda was dismantled and the new floor joists were removed HV‟s report 10 December Oct 13  The hou se and patio were built in 1989  The spacing of the floor jo ists being 600mm was acceptable at that time  No further lateral strap bracing is required or would improve the struc tural adequacy of the structure  The method of fixing the handrails is not relevant.  The fixing of the handrail slats is not relevant to the structural design  The use of galvanised clouts would have been and still is acceptable HV‟s report 21 February 2014  HV reviewed the FSP „s IDR letter 13 February 2014  HV noted the length of the joists varied and the extension length of the joists for the 1800mm wide patio varied  If the patio was extended it would be reasonable to assume that all the extensions would be the same length  There is no evidence of relocation of the three brick piers and the appearance of the brick and mortar indicates they were built at the same time as the house  The patio was built with the extended joists at the same time as the house and met the relevant Standards C Building inspections reports 28 October 2013  C attended on 21 October 2013  Most of the damaged structure had been cleaned up so he couldn‟t fully comment on the cause of failure of the rear deck  There was lack of bracing on front and rear decks and both decks should have been braced  The mortar in the brick piers of the front deck was soft and some missing an d some movement in the piers. If the rear deck the same then this would have contributed to its failure  Most of the original joists were still in place as they are a continuation of the floor joist of the main building  Further the joists are made of Oregon pine and this material has Case No: 354765 Determination Page 6 of 6 not been used in deck construction since the early 1990‟s  The deck was built during the construction of the main building Photographs attached to letters 8 October 2014 and 20 May 2014  Photos produced to show that joists are part of the original construction as they continue through to the front of the house and are said to show the deck has not been modified since its original construction and that there is no difference in building materials or appearance of any part of the deck

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.