Home / Financial Firm (Unknown - Insurer) / Determination 354765
Determination 354765
Denial of claim-Exclusion/condition
Summary
The applicants' storm claim for a collapsed veranda was denied on the basis that no violent wind was shown and the damage arose from faulty workmanship. AFCA found no storm was established and faulty workmanship is excluded, deciding in favour of the FSP.
The applicants had the onus to prove a storm event, the evidence did not establish a violent wind, and faulty workmanship is excluded under the policy.
Issues
- Claim denial primary · not upheld“the faulty workmanship identified by both C and the assessor operate to defeat the claim”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of
claim-Exclusion/ condition
Determination
Case No: 354765 Determination Page 1 of 6
Case number : 354765 12 November 2014
1 Overview
1.1 Dispute
The Applicants held a home building insurance policy with the Financial Services
Provider (FSP) under which they lodged a claim for storm damage to a veranda.
The FSP denied the claim on the grounds the damage was not as a result of a
storm rather, that it arose from faulty workmanship which is excluded under the
terms of the policy.
The Applicants dispute the FSP‟s findings and seek a review of the decision to
deny their claim.
The Applicants are represented. For the sake of brevity, both the Applicants and
their representative will be referred to as “the Applicants”.
The Case Manager provided the parties with a Recommendation on the issues in
dispute. The Recommendation was in favour of the FSP.
The FSP accepted the Recommendation but it was not accepted by the
Applicants. In the circumstances, the dispute has been referred to me for
Determination.
1.2 Issue and key findings
Was the FSP entitled t o deny the Applicants’ claim ?
The FSP was entitled to deny the claim because:
there is no evidence a storm as defined occurred on the night of the loss
the evidence suggests the damage arose from faulty workmanship
damage arising from faulty workmanship is excluded under the terms of the
policy.
1.3 Determination
This Determination is in favour of the FSP.
The FSP is entitled to deny the Applicants‟ claim and need take no further action.
Case No: 354765 Determination Page 2 of 6
2 Reasons for Decision
I have decided this case on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous FOS decisions. I have taken into
account all the material submitted by the parties, both before and after the
Recommendation. I am satisfied that the documentation I have relied on has been
provided to both parties.
After the Recommendation was rejected, the Applicants made further
submissions and provided further material from a building inspector, C. The FSP
provided no new material but said the report from C corroborates the findings of
the FSP‟s builder that the damage to the home was as a result of substandard
building rather than storm damage as alleged by the Applicants.
2.1 Was the FSP entitled to deny the Applicants’ claim ?
The policy provides cover for damage arising from storm
In this matter the Applicants must establish on the balance of probabilities the
damage was caused by a storm. If this is established, the FSP must show the
damage was caused by faulty design, workmanship or because the veranda was
not structurally sound.
The damage was not caused by a storm as there is no persuasive evidence
that there was a violent wind
The Applicants made a claim on 7 October 2013 and said that “during the early
hours of the morning there was a strong wind storm which caused the back
outside decking on the second storey to collapse.”
The Applicants have provided a daily weather observation from Nelson Bay, a
weather station proximate to their home. The reading closest to the early hours of
7 October 2013 is a reading at 9am which records a wind from the South
recorded at 28kmph. No wind gusts are recorded.
The FSP says that the search of the BOM site at the closest weather station did
not display any unusual reports of high wind in the vicinity to cause a structure the
size of a veranda to fall down. And they say that no other claims were made for
storm related claims on 7 October 2013.
The Beaufort Wind scale can be found in the website of the Bureau of
Meteorology (BOM). Item 6 of the Beaufort Scale lists Strong Winds which are
winds 40-50kmph. The Scale progresses to item 11 Violent Storm where winds
are 103kmph.
The FSP‟s assessor was told that the Applicants were awakened by loud banging
and glass breaking. The Applicants told him they then discovered a section of
hand rail and a brick supporting pier had moved in the strong wind and collapsed
to the ground below. The breaking glass was a table below which was shattered
by the fall.
Case No: 354765 Determination Page 3 of 6
The assessor attended the site on 7 October at 1pm and took photographs. The
photographs show the debris referred to on the ground. But I consider the
photographs do not show any other damage consistent with a violent wind. There
is no sign of any other debris that would be caused by such a violent wind. Light
garden furniture and pots are evident in the photographs and appear undamaged.
To succeed, the Applicants must establish the damage was caused by a storm as
defined in the policy. A storm is defined amongst other things as a “violent wind,
cyclone or tornado”. The Beaufort Scale says strong win ds are those of 40-
50kmph. I consider a violent wind would be greater than that if not as great as a
wind in a violent storm where there are winds as great as 103kmph. Even if I was
to accept that there was a violent wind but that wind or gust was not detected and
not recorded, I would then expect there to be more extensive damage which is not
claimed by the Applicants and not seen in the photographs taken on 7 October
2013.
On the material to hand, I am not satisfied that the Applicants have established on
the balance of probabilities that there was an insured event – namely a violent
wind which caused the damage to the veranda.
The FSP’s assessor saw the veranda’s structure at the time of the loss and
was best placed to comment on the workmanship
The FSP says that the cause of the damage was not a storm as defined but faulty
workmanship of the veranda when it was extended about a year before. This was
shortly before the Applicants purchased the house.
Three experts have reported on the veranda and commented upon its
construction. C inspected the veranda on 21 October 2013 and admits that as
most of the damaged structure had been cleaned up he couldn‟t really comment
on the cause of failure. He does criticise the lack of bracing and the mortar in the
bricks. In all the circumstances I do not consider his report carries the necessary
weight to support the Applicants.
Further neither of the Applicants‟ experts actually say that the veranda was
damaged in a storm.
It is not clear that the other expert relied on by the Applicants (HV) has ever
actually inspected the property. But if he did, as his first report is written on 10
December 2013, he also does not have the advantage enjoyed by the FSP‟s
assessor of inspecting the damage contemporaneously with the claim. It is noted
that the “remaining columns” are pulled down on 10 October 2013 by the
assessor and when the building was made safe the veranda was dismantled and
the new floor joists removed.
In all the circumstances I am persuaded on the balance of probabilities that if the
veranda was damaged in a storm (and I do not accept this is established) that the
faulty workmanship identified by both C and the assessor operate to defeat the
claim.
Case No: 354765 Determination Page 4 of 6
3 Supporting information
3.1 FOS Approach
It is an accepted principle of general insurance law that an insured bears the onus
to establish on the balance of probabilities that they have suffered a loss caused
by an event to which the policy responds. This is known as a prima facie claim.
Once so established, the onus shifts to the insurer to prove on the balance of
probabilities that an exclusion applies if it seeks to deny or limit its liability for the
loss.
3.2 Extract Policy documents
Storm
If loss or damage is caused by a storm
……..
Covered
violent wind, cyclone or tornado
We don't cover loss, damage, injury or death arising from:
faulty design or workmanship
…..
you not maintaining your home in good repair and condition. This means your home must
be watertight, structurally sound, secure and well maintained.
3.3 Expert evidence
Report Findings
BOM report at
the location of
the Applicants‟
property on 7
October 2013
The search area is calculated at a 50km radius
No reports or observations of strong winds – that is sustained
winds above 50km/h or gusts above 90km/h
It is possible that some strong winds are not detected because no
reports are received
Terrain may cause localized wind gusts stronger than those
detected by the “sparse observation network.” And the gusts may
not be recorded or identified as many stations o nly record wind
speeds on an hourly basis
BOM daily
weather
observations
Winds at 9am 7 October 2013 S 28km/h
AG‟s report
7 Oct 2013 and
emails 10
February 2014
The Applicants said the veranda was damaged in a high wind in
the early hours on 7 October 2013
AG inspected and photographed the veranda on 7 October and
pulled down remai ning columns on 10 October 2013
The Applicants informed him the verandah was built
approximately 12 months ago s hortly before they purchased it
Case No: 354765 Determination Page 5 of 6
The damage was caused by poor construction methods which
allowed the verandah to move in windy conditions
The floor joists were spaced at 600mm centres whereas to
accommodate the pine decking they should be at 450mm centres.
There is no lateral strap bracing to the jois ts to prevent si deways
movement
The timber handrails were installed using thin plastic plugs
instead of masonry anchors.
The timber handrail slats have been nailed instead of being
screwed
The original veranda may have been cantilevered and then
extended about 12 - 14 months ago with new floor joists bolted to
the existing protruding floor joist (see photos). The brick piers
were put up then too
Original veranda was built to Standards but the extension was not
AG reviewed the report from HV and said HV would have seen
t he remaining original floor joists and not the new extended work
as when it was made safe, the veranda was dismantled and the
new floor joists were removed
HV‟s report
10 December
Oct 13
The hou se and patio were built in 1989
The spacing of the floor jo ists being 600mm was acceptable at
that time
No further lateral strap bracing is required or would improve the
struc tural adequacy of the structure
The method of fixing the handrails is not relevant.
The fixing of the handrail slats is not relevant to the structural
design
The use of galvanised clouts would have been and still is
acceptable
HV‟s report
21 February
2014
HV reviewed the FSP „s IDR letter 13 February 2014
HV noted the length of the joists varied and the extension length
of the joists for the 1800mm wide patio varied
If the patio was extended it would be reasonable to assume that
all the extensions would be the same length
There is no evidence of relocation of the three brick piers and the
appearance of the brick and mortar indicates they were built at
the same time as the house
The patio was built with the extended joists at the same time as
the house and met the relevant Standards
C Building
inspections
reports
28 October
2013
C attended on 21 October 2013
Most of the damaged structure had been cleaned up so he
couldn‟t fully comment on the cause of failure of the rear deck
There was lack of bracing on front and rear decks and both decks
should have been braced
The mortar in the brick piers of the front deck was soft and some
missing an d some movement in the piers. If the rear deck the
same then this would have contributed to its failure
Most of the original joists were still in place as they are a
continuation of the floor joist of the main building
Further the joists are made of Oregon pine and this material has
Case No: 354765 Determination Page 6 of 6
not been used in deck construction since the early 1990‟s
The deck was built during the construction of the main building
Photographs
attached to
letters 8 October
2014 and 20
May 2014
Photos produced to show that joists are part of the original
construction as they continue through to the front of the house
and are said to show the deck has not been modified since its
original construction and that there is no difference in building
materials or appearance of any part of the deck
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.