Home / Financial Firm (Unknown - Insurer) / Determination 354665

Determination 354665

Denial of home building claim for cracking and movement

FirmFinancial Firm (Unknown - Insurer)
Decided2014-11-27
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The Applicants claimed on their home building policy for cracking and movement to their home, which the FSP denied. AFCA found the damage arose from long-term subsidence, an excluded earth movement, and the FSP need take no further action.

The Applicants did not link a covered leaking pipe to the damage, and the policy excludes loss from earth movement.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim Determination Case No: 354665 Determination Page 1 of 7 Case number: 354665 25 November 2014 1 Overview 1.1 Dispute The Applicants hold a home building and contents policy with the Financial Services Provider (FSP) covering their home address for a sum insured of $235,000. On 4 June 2012 the Applicants lodged a claim with the FSP in respect of cracking and movement to the home which had been occurring over a period of years. After considering the claim and expert opinions the FSP denied it on the basis that the loss had not arisen as a result of an event which was covered by the policy. The Applicants dispute that decision. 1.2 Issues and key findings Was the FSP entitled to deny the claim? The FSP was entitled to deny the claim because:  the damage did not arise as a result of an insured event  the loss arose from earth movement which is a cause specifically excluded from cover under the policy 1.3 Determination This Determination is in favour of the FSP. The FSP was entitled to deny the Applicants‟ claim and need take no further action. Case No: 354665 Determination Page 2 of 7 2 Reasons for Determination 2.1 Was the FSP entitled to deny the claim? Damage was not caused by the insured event of leaking pipes The FSP‟s policy is a defined events policy. Therefore, the policy only responds where the damage has been caused by one or more of the listed events, subject to any policy exclusions. One of the listed events is damage from leaking pipes. The policy will also respond to subsidence damage to the home which is caused by a leaking or burst pipe. The onus rests with the policyholder to establish on the balance of probabilities that a loss has been suffered by a cause covered by the terms of the policy. Once the Applicants have discharged this onus, the onus then shifts to the FSP to demonstrate that on the balance of probabilities one or more of the listed exclusions operates to defeat the claim. It is not disputed between the parties that the damage to the home has arisen as a result of soil and foundation movement at the site. The Applicants assert the reason for the soil movement is due to an extensive pipe leak in around 2002/2003, which has disgorged liquid into the surrounding soils causing movement. As the policy includes the insured event of „burst pipes, leaks and overflows‟ from a pipe, the Applicants assert the pol icy should respond. The Applicants have provided evidence of a noticeable spike in their water usage for about 12 months from November 2002 which supports that there was a substantial leak at the premises. They also say that the leak was directly under a major support area and this fact and the sheer volume of the water must have caused the damage. They also rebut some of the underlying premises relied on by the FSP‟s expert – they say there is no creek at the rear of the property (although their own expert C notes a low lying creek area at the rear of the block) and that there had been other bad drought years before 2003 and yet no damage had been noted to the house. But in order to trigger the policy coverage, a clear causal link between the leaking pipe and the damage which is now evident, some 11 years later, must be established. Although the Applicants make certain assertions they have produced no expert evidence is support of their contentions. Further the FSP‟s expert has dealt with the assertions. But most critically the material provided by the soil expert C supports the opinion of the FSP‟s expert. In all the circumstances I am not satisfied the Applicants have provided sufficient evidence to link the leak to the damage. On this basis, the Applicants have not discharged their onus to establish on the balance of probabilities the damage was caused by an insured event and have not established on the balance of probabilities the policy responds to the claim. Case No: 354665 Determination Page 3 of 7 Loss arose from earth movement which is specifically excluded from cover Further, the material supplied does not support the Applicants‟ position that the damage arose as a result of a leaking pipe. The engineering firm “JH” inspected the damaged building at the instruction of the FSP. JH concluded the damage had arisen as a result of soil settlement, caused by the fact that the home was constructed on an infill site which had not been properly compacted. The piers of the home were also not founded on stable soil but infill, which has meant that over time, the infill has settled causing the foundations to subside. JH considered the effect the leak may have had on the property, if any, but concluded that there was no evidence to suggest it had been a dominant or even contributing factor to the loss. JH considered damage caused by a leak would be localised to the immediate surrounding area, whereas in this instance, the entire house has settled at the rear along a plane. Further, as the block slopes rearward toward a creek bed, any leak would flow downhill toward the creek rather than uphill back toward the house. Had the leak caused any damage, this would be localised, whereas the damage to the house is across the rear as a whole, along a plane. It is accepted that JH is appropriately qualified and e xperienced to comment on this matter and in the absence of conflicting information, the FSP is entitled to rely on his findings. The Applicants disagree with JH‟s findings and submit he has not considered the effect and sheer volume of water being disgorged onto the site. However, the Applicants have not provided sufficient supporting information from a suitably qualified person to contradict the findings on which the FSP has relied. The Applicants have provided a brief email from “RR” who they say is an engineer, although no evidence of qualifications have been supplied. The content of RR‟s email is suggestive of him not having physically inspected the site. Rather, he has formed his view on the basis of the soil report from C commissioned by the Applicants. Accordingly, this report cannot be considered to hold the weight that JH‟s reports do, given his personal inspections at the site. Moreover RR is supportive of the FSP‟s position. RR concluded that the subsidence has occurred as a result of either the drying of the highly reactive clay soils or as a result of settlement of the soft layer immediately under the infill. Whilst RR does opine that the settlement could have been contributed to by the leaking pipe, he raises this only as a possibility, whe reas he considers the „probable‟ cause of the settlement is the drying out of the highly reactive soils. Accordingly, the evidence presented confirms that on the balance of probabilities the damage to the home has arisen as a result of long term subsidence at the site caused by a combination of factors including improperly compacted infill, inadequate foundations and the long running drought. As the policy specifically excludes loss or damage arising from any form of earth movement, the FSP is entitled to deny the claim. Case No: 354665 Determination Page 4 of 7 3 Supporting information 3.1 FOS approach for this dispute This dispute has not been the subject of a FOS Recommendation. Due to its nature, FOS has considered it appropriate to proceed directly to Determination in line with the Operational Guidelines to the FOS Terms of Reference. I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties. I am satisfied that the documentation I have relied on has been provided to both parties. Material supplied by the parties will only be referred to in this decision where relevant and in context. 3.2 Extracts from policy The Notice of Response sets out the relevant policy extracts. 3.3 Expert Evidence Record Key points FSP’s expert (JH) Master Builder and Engineer‟s Report 10 Jul 2012  the block the house is located on is relatively flat but the rear of the block sets down approximately two metres to a creek  the property is estimated to be about 23 years old  it is constructed of external concrete footings supporting brick walls. The internal timber floor of the dwelling is supported on the external brick footings and then on individual brick piers. There is a con crete slab at the rear of the dwelling  the owner advises there is significant movement occurring since 2003 which has increased over time. In 2003 there was a water leak which went undetected over a number of months before it was repaired  the brick garage toward the front of the block has not been affected and shows no sign of distress  inspection found that there was significant evidence of substantial movement to the foundations of the dwelling  the floors were out of level and extensive cracking of brickwo rk and plasterwork was observed  the damage has been occurring for a considerable time and there is evidence of previous repairs and attempts to rectify the damage  a laser level survey was undertaken around the perimeter of the building and the interior  the results of the laser level survey found the dwelling has settled towards the rear of the building by 60mm Case No: 354665 Determination Page 5 of 7  the extent of the movement was relatively consistent across the rear of the dwelling  the evidence indicates the dwelling was constructed on fill  it a ppears the natural ground level of the block was to slope from front to rear where the creek was  the block has been filled to raise the ground level above potential flood level and to provide a level block to construct on  review of the plans found that the foundations that were installed did not specify any piers into natural ground  the movement of the dwelling is typical of dwellings that are constructed on a wedge of fill  the deepest section of the fill settles the greatest and hence the dwelling slopes f rom front to back mirroring the fill  if the soil was affected by the water leak in 2003 then the movement of the foundations would have been localized around the leak  the laser level survey indicated that the settlement of the house is on a plane, the plan e slopes relatively evenly from front to rear down the block  the evidence does not support a water leak  the evidence suggests up until 2003 the soil would have been in moist condition as since the original construction to that time, normal weather conditio ns prevailed  from 2003 to 2008 the worst drought in 100 years occurred  as the soil dries out over depth, it loses volume and shrinks  areas of deep poorly compacted fill will shrink the most compared to the original consolidated soil  the foundations follow as the soil shrinks  the breaking of the drought and extreme weather events over the last couple of years will help wash fines thought the fill, which again leads to further settlement of the fill  the movement of the foundations is well outside acceptable standards and the structural integrity of the house has been compromised  the movement has occurred over time and is not attributed to a single event . Applicant’s expert (C) 24 March 2014  C carried out soil testing on 13 March 2014  low lying alluvial area s with rear intermittent watercourse  sand and clay fills overlying natural alluvial silts and sands  house cracked at rear as the rear footings have settled  highly reactive clay fill as the rear of the block overlaying a low lying creek area  noted he was t old of the leaking pipe but makes not comment re causation . Applicant’s expert (RR) Emailed Report 01 Jul 2014  RR is described by the Applicant as a structural engineer  the soil report was reviewed by RR  RR understands the rear of the house has undergone significant settlement compared to the front of the house Case No: 354665 Determination Page 6 of 7  the footings seem to be founded through the fill material into the natural ground  at the rear where the footings are founded 1400mm below ground level there is a layer of soft material at 1600mm depth which is approximately 700mm thick. Below this is reasonable material again  it is likely there are two probable causes of the damage 1. the footings have settled because of the drying out of the highly reactive clays 2. more likely, the footings have settl ed because of the layer of soft material immediately below the founding depth of the footing at the rear  it is possible this could have been exacerbated by a leaking pipe . FSP’s expert (JH) Supplementary Engineer‟s Reports 23 September and 14 October 201 4  JH was asked to provide advice and interpretation of the soil report prepared for the owner by soil testers “C” and considered it confirmed the probable cause of the movement as set out in his earlier report  That is that the movement of the house is attr ibuted to long term settlement of the fill and soils on the site made worse by the drought 2002 - 2009  There is no evidence to indicate that the leak at the rear of the house has caused the gross moment of the house  His earlier report concluded that the caus e of the damage was due to the compaction of the fill that the property was constructed on, causing the house to subside  the house had moved along a plane which is indicative of the deeper levels of fill compacting at a greater rate  given the vicinity of the creek it was suspected that the soils would of unconsolidated soils which would have a high capacity for consolidation under load, as the greater the fill, the greater capacity for consolidation  the load was applied by the construction of the house  the soils in the area are highly reactive which means as they lose moisture the soil will shrink and to a certain extent, they will swell when they absorb water  often during a period of drought (such as from 2002 to 2009) as the soil shrinks the house compres ses the soil  when wetter periods return, the amount of shrinkage is not recovered and the house remains in a titled and distressed condition  the soil report confirms fill was placed at the site  the fill depth ranges from 500mm at the front of the house to 1.6metres deep at the rear  the fill is also defined as highly reactive towards the rear of the dwelling  there are a large mix of different soils on the site given that the sands at the front were not found at the rear  this is typical of a site near a creek where various soils are washed towards the creek  the larger movement is at the rear of the site which is Case No: 354665 Determination Page 7 of 7 consistent with the movement associated with the soils profiles as recorded in the soil report  the creek is lower than the rear of the house  hydraulic principles would note that the water from the leak which occurred would not travel uphill toward the house but rather downhill directly toward the creek  hence any damage attributed to the leak would be localised  this is not reflected in the level survey u ndertaken or the damage observed to the house  as noted in 2012, the whole house has moved, which is far removed from the original location of the leak  the movement is all related to the type of soil the building is constructed on and the footings that were installed  a leak in the soil would have resulted in swelling and potential uplift (heave) in the soil  sinking is attributed to a loss of moisture and shrinkage of the soil  the premise of a water leak being the cause of the damage is inconsistent with the soil properties on site, the levels measured and the extent of obvious distress of the house and garage .

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.