Determination 354665
Denial of home building claim for cracking and movement
Summary
The Applicants claimed on their home building policy for cracking and movement to their home, which the FSP denied. AFCA found the damage arose from long-term subsidence, an excluded earth movement, and the FSP need take no further action.
The Applicants did not link a covered leaking pipe to the damage, and the policy excludes loss from earth movement.
Issues
- Claim denial primary · not upheld“As the policy specifically excludes loss or damage arising from any form of earth movement, the FSP is entitled to deny the claim.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of
Claim
Determination
Case No: 354665 Determination Page 1 of 7
Case number: 354665 25 November 2014
1 Overview
1.1 Dispute
The Applicants hold a home building and contents policy with the Financial
Services Provider (FSP) covering their home address for a sum insured of
$235,000.
On 4 June 2012 the Applicants lodged a claim with the FSP in respect of cracking
and movement to the home which had been occurring over a period of years.
After considering the claim and expert opinions the FSP denied it on the basis
that the loss had not arisen as a result of an event which was covered by the
policy. The Applicants dispute that decision.
1.2 Issues and key findings
Was the FSP entitled to deny the claim?
The FSP was entitled to deny the claim because:
the damage did not arise as a result of an insured event
the loss arose from earth movement which is a cause specifically excluded
from cover under the policy
1.3 Determination
This Determination is in favour of the FSP.
The FSP was entitled to deny the Applicants‟ claim and need take no further
action.
Case No: 354665 Determination Page 2 of 7
2 Reasons for Determination
2.1 Was the FSP entitled to deny the claim?
Damage was not caused by the insured event of leaking pipes
The FSP‟s policy is a defined events policy. Therefore, the policy only responds
where the damage has been caused by one or more of the listed events, subject
to any policy exclusions. One of the listed events is damage from leaking pipes.
The policy will also respond to subsidence damage to the home which is caused
by a leaking or burst pipe.
The onus rests with the policyholder to establish on the balance of probabilities
that a loss has been suffered by a cause covered by the terms of the policy. Once
the Applicants have discharged this onus, the onus then shifts to the FSP to
demonstrate that on the balance of probabilities one or more of the listed
exclusions operates to defeat the claim.
It is not disputed between the parties that the damage to the home has arisen as
a result of soil and foundation movement at the site.
The Applicants assert the reason for the soil movement is due to an extensive
pipe leak in around 2002/2003, which has disgorged liquid into the surrounding
soils causing movement. As the policy includes the insured event of „burst pipes,
leaks and overflows‟ from a pipe, the Applicants assert the pol icy should respond.
The Applicants have provided evidence of a noticeable spike in their water usage
for about 12 months from November 2002 which supports that there was a
substantial leak at the premises. They also say that the leak was directly under a
major support area and this fact and the sheer volume of the water must have
caused the damage. They also rebut some of the underlying premises relied on
by the FSP‟s expert – they say there is no creek at the rear of the property
(although their own expert C notes a low lying creek area at the rear of the block)
and that there had been other bad drought years before 2003 and yet no damage
had been noted to the house.
But in order to trigger the policy coverage, a clear causal link between the leaking
pipe and the damage which is now evident, some 11 years later, must be
established. Although the Applicants make certain assertions they have produced
no expert evidence is support of their contentions. Further the FSP‟s expert has
dealt with the assertions. But most critically the material provided by the soil
expert C supports the opinion of the FSP‟s expert.
In all the circumstances I am not satisfied the Applicants have provided sufficient
evidence to link the leak to the damage. On this basis, the Applicants have not
discharged their onus to establish on the balance of probabilities the damage was
caused by an insured event and have not established on the balance of
probabilities the policy responds to the claim.
Case No: 354665 Determination Page 3 of 7
Loss arose from earth movement which is specifically excluded from cover
Further, the material supplied does not support the Applicants‟ position that the
damage arose as a result of a leaking pipe.
The engineering firm “JH” inspected the damaged building at the instruction of the
FSP. JH concluded the damage had arisen as a result of soil settlement, caused
by the fact that the home was constructed on an infill site which had not been
properly compacted. The piers of the home were also not founded on stable soil
but infill, which has meant that over time, the infill has settled causing the
foundations to subside.
JH considered the effect the leak may have had on the property, if any, but
concluded that there was no evidence to suggest it had been a dominant or even
contributing factor to the loss. JH considered damage caused by a leak would be
localised to the immediate surrounding area, whereas in this instance, the entire
house has settled at the rear along a plane. Further, as the block slopes rearward
toward a creek bed, any leak would flow downhill toward the creek rather than
uphill back toward the house. Had the leak caused any damage, this would be
localised, whereas the damage to the house is across the rear as a whole, along
a plane.
It is accepted that JH is appropriately qualified and e xperienced to comment on
this matter and in the absence of conflicting information, the FSP is entitled to rely
on his findings.
The Applicants disagree with JH‟s findings and submit he has not considered the
effect and sheer volume of water being disgorged onto the site. However, the
Applicants have not provided sufficient supporting information from a suitably
qualified person to contradict the findings on which the FSP has relied.
The Applicants have provided a brief email from “RR” who they say is an
engineer, although no evidence of qualifications have been supplied.
The content of RR‟s email is suggestive of him not having physically inspected the
site. Rather, he has formed his view on the basis of the soil report from C
commissioned by the Applicants. Accordingly, this report cannot be considered to
hold the weight that JH‟s reports do, given his personal inspections at the site.
Moreover RR is supportive of the FSP‟s position. RR concluded that the
subsidence has occurred as a result of either the drying of the highly reactive clay
soils or as a result of settlement of the soft layer immediately under the infill.
Whilst RR does opine that the settlement could have been contributed to by the
leaking pipe, he raises this only as a possibility, whe reas he considers the
„probable‟ cause of the settlement is the drying out of the highly reactive soils.
Accordingly, the evidence presented confirms that on the balance of probabilities
the damage to the home has arisen as a result of long term subsidence at the site
caused by a combination of factors including improperly compacted infill,
inadequate foundations and the long running drought.
As the policy specifically excludes loss or damage arising from any form of earth
movement, the FSP is entitled to deny the claim.
Case No: 354665 Determination Page 4 of 7
3 Supporting information
3.1 FOS approach for this dispute
This dispute has not been the subject of a FOS Recommendation. Due to its
nature, FOS has considered it appropriate to proceed directly to Determination in
line with the Operational Guidelines to the FOS Terms of Reference.
I have decided this case on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous FOS decisions. I have taken into
account all the material submitted by the parties. I am satisfied that the
documentation I have relied on has been provided to both parties.
Material supplied by the parties will only be referred to in this decision where
relevant and in context.
3.2 Extracts from policy
The Notice of Response sets out the relevant policy extracts.
3.3 Expert Evidence
Record Key points
FSP’s expert (JH)
Master Builder and
Engineer‟s Report
10 Jul 2012
the block the house is located on is relatively flat but the
rear of the block sets down approximately two metres to a
creek
the property is estimated to be about 23 years old
it is constructed of external concrete footings supporting
brick walls. The internal timber floor of the dwelling is
supported on the external brick footings and then on
individual brick piers. There is a con crete slab at the rear of
the dwelling
the owner advises there is significant movement occurring
since 2003 which has increased over time. In 2003 there
was a water leak which went undetected over a number of
months before it was repaired
the brick garage toward the front of the block has not been
affected and shows no sign of distress
inspection found that there was significant evidence of
substantial movement to the foundations of the dwelling
the floors were out of level and extensive cracking of
brickwo rk and plasterwork was observed
the damage has been occurring for a considerable time
and there is evidence of previous repairs and attempts to
rectify the damage
a laser level survey was undertaken around the perimeter
of the building and the interior
the results of the laser level survey found the dwelling has
settled towards the rear of the building by 60mm
Case No: 354665 Determination Page 5 of 7
the extent of the movement was relatively consistent
across the rear of the dwelling
the evidence indicates the dwelling was constructed on fill
it a ppears the natural ground level of the block was to
slope from front to rear where the creek was
the block has been filled to raise the ground level above
potential flood level and to provide a level block to
construct on
review of the plans found that the foundations that were
installed did not specify any piers into natural ground
the movement of the dwelling is typical of dwellings that
are constructed on a wedge of fill
the deepest section of the fill settles the greatest and
hence the dwelling slopes f rom front to back mirroring the
fill
if the soil was affected by the water leak in 2003 then the
movement of the foundations would have been localized
around the leak
the laser level survey indicated that the settlement of the
house is on a plane, the plan e slopes relatively evenly from
front to rear down the block
the evidence does not support a water leak
the evidence suggests up until 2003 the soil would have
been in moist condition as since the original construction to
that time, normal weather conditio ns prevailed
from 2003 to 2008 the worst drought in 100 years occurred
as the soil dries out over depth, it loses volume and shrinks
areas of deep poorly compacted fill will shrink the most
compared to the original consolidated soil
the foundations follow as the soil shrinks
the breaking of the drought and extreme weather events
over the last couple of years will help wash fines thought
the fill, which again leads to further settlement of the fill
the movement of the foundations is well outside acceptable
standards and the structural integrity of the house has
been compromised
the movement has occurred over time and is not attributed
to a single event .
Applicant’s expert (C)
24 March 2014
C carried out soil testing on 13 March 2014
low lying alluvial area s with rear intermittent watercourse
sand and clay fills overlying natural alluvial silts and sands
house cracked at rear as the rear footings have settled
highly reactive clay fill as the rear of the block overlaying a
low lying creek area
noted he was t old of the leaking pipe but makes not
comment re causation .
Applicant’s expert (RR)
Emailed Report
01 Jul 2014
RR is described by the Applicant as a structural engineer
the soil report was reviewed by RR
RR understands the rear of the house has undergone
significant settlement compared to the front of the house
Case No: 354665 Determination Page 6 of 7
the footings seem to be founded through the fill material
into the natural ground
at the rear where the footings are founded 1400mm below
ground level there is a layer of soft material at 1600mm
depth which is approximately 700mm thick. Below this is
reasonable material again
it is likely there are two probable causes of the damage
1. the footings have settled because of the drying out of the
highly reactive clays
2. more likely, the footings have settl ed because of the layer
of soft material immediately below the founding depth of
the footing at the rear
it is possible this could have been exacerbated by a
leaking pipe .
FSP’s expert (JH)
Supplementary
Engineer‟s Reports
23 September and 14
October 201 4
JH was asked to provide advice and interpretation of the
soil report prepared for the owner by soil testers “C” and
considered it confirmed the probable cause of the
movement as set out in his earlier report
That is that the movement of the house is attr ibuted to long
term settlement of the fill and soils on the site made worse
by the drought 2002 - 2009
There is no evidence to indicate that the leak at the rear of
the house has caused the gross moment of the house
His earlier report concluded that the caus e of the damage
was due to the compaction of the fill that the property was
constructed on, causing the house to subside
the house had moved along a plane which is indicative of
the deeper levels of fill compacting at a greater rate
given the vicinity of the creek it was suspected that the
soils would of unconsolidated soils which would have a
high capacity for consolidation under load, as the greater
the fill, the greater capacity for consolidation
the load was applied by the construction of the house
the soils in the area are highly reactive which means as
they lose moisture the soil will shrink and to a certain
extent, they will swell when they absorb water
often during a period of drought (such as from 2002 to
2009) as the soil shrinks the house compres ses the soil
when wetter periods return, the amount of shrinkage is not
recovered and the house remains in a titled and distressed
condition
the soil report confirms fill was placed at the site
the fill depth ranges from 500mm at the front of the house
to 1.6metres deep at the rear
the fill is also defined as highly reactive towards the rear of
the dwelling
there are a large mix of different soils on the site given that
the sands at the front were not found at the rear
this is typical of a site near a creek where various soils are
washed towards the creek
the larger movement is at the rear of the site which is
Case No: 354665 Determination Page 7 of 7
consistent with the movement associated with the soils
profiles as recorded in the soil report
the creek is lower than the rear of the house
hydraulic principles would note that the water from the leak
which occurred would not travel uphill toward the house
but rather downhill directly toward the creek
hence any damage attributed to the leak would be
localised
this is not reflected in the level survey u ndertaken or the
damage observed to the house
as noted in 2012, the whole house has moved, which is far
removed from the original location of the leak
the movement is all related to the type of soil the building is
constructed on and the footings that were installed
a leak in the soil would have resulted in swelling and
potential uplift (heave) in the soil
sinking is attributed to a loss of moisture and shrinkage of
the soil
the premise of a water leak being the cause of the damage
is inconsistent with the soil properties on site, the levels
measured and the extent of obvious distress of the house
and garage .