Home / Financial Firm (Unknown - Insurer) / Determination 353989

Determination 353989

Denial of home building cracking claim under soil movement exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2014-08-22
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicants claimed for cracking in their home and attributed it to a leaking sewer pipe, and the FSP denied the claim as soil settlement. AFCA found the damage was caused by excluded soil settlement and ordered nothing.

The policy excludes loss caused by soil movement or settlement, and the evidence showed settlement rather than leak-induced heave.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim-Exclusion/ condition Determination Case No: 353989 Determination Page 1 of 5 Case number : 353989 21 August 2014 1 Overview 1.1 Dispute The Applicants lodged a claim against their home building insurance policy (Policy) held with the insurer (FSP) for cracks to the ceiling, walls and concrete slab. The Applicants state that water from a leaking pipe has caused the damage. The FSP denied liability for the damage on the basis that it was caused by soil settlement, which is excluded from cover. 1.2 Issues and key findings Is the FSP liable for the damage to the Applicants’ home building ? The FSP is not liable for the damage to the Applicants’ home building because:  On the balance of probabilities the damage was caused by settlement of the soil on the north-western side of the home, which was the older part of the home. Significant cracking was at the junction of the older and newer parts of the home.  The damage is therefore not caused by an event covered by the Policy.  Further, the Policy specifically excludes damage caused by soil mo vement or settlement.  Water from a leaking sewer pipe was not the cause of the soil settlement observed at the site. The water leak would have caused the soil to expand rather than to subside. It was the subsiding soil that caused the cracking. 1.3 Determination This Determination is in favour of the FSP. The damage is not covered by the Policy and the FSP is entitled to deny the Applicants’ claim. Case No: 353989 Determination Page 2 of 5 2 Reasons for Determination I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties. I am satisfied that the documentation I have relied on has been provided to both parties. 2.1 Is the FSP liable for the damage to the Applicants’ home ? The Policy provides cover for certain water leaks but excludes loss caused by soil movement or settlement The Policy provides cover for certain events, including “liquid escaping suddenly and unexpectedly from a fixed pipe” subject to certain exclusions, including any loss caused by or arising from or involving “soil movement or settlement”. Burden of proof shifts in respect of the Applicants’ claim The onus rests with the Applicants to prove, on the balance of probabilities, they sustained a loss caused by an event insured for under the policy in force, at the date of loss. Once the Applicants satisfy this onus, the burden shifts to the FSP to establish the claim falls within an exclusion from cover. Damage caused by settlement on north-western side of home The evidence shows that the cracking in the Applicants’ home has been caused by movement of the structural foundations, caused by subsidence of the soil under the northern part of the home. The Applicants’ engineer (“M”) provide d a preliminary report suggesting that there were two possible causes for the movement of the buildings’ foundations, either:  uplifting of the ground at the site of the cracking (the join of the old and new parts of the home), or  subsidence of the soil on the southern side of the home. M noted that the primary soil type in the area was such that water entering below the slab would cause the soil to swell resulting in an upwards reaction on the underside of the concrete slab, causing it to bow upwards. M recommended an investigation of the existing pipework to determine any leakage points. If no pipe leak could be found, a soil test should be carried out. The FSP’s engineer (“MP”) undertook a level survey which demonstrated that the older northern side of the home had significantly subsided relative to the site of the crack and the newer southern side of the home. MP was also of the view that the soils in the area were reactive clay that expands with moisture and shrinks when moisture content reduces, but no soil tests were undertaken. A leakage test conducted by “J” revealed a leak in the sewer drainage pipe in the north-western corner of the property. Case No: 353989 Determination Page 3 of 5 MP concluded that the cause of the damage was gradual settlement of the foundation soil under the older part of the home, most significantly along the north-western wall. The settlement was most likely caused by gradually reducing soil moisture as a result of seasonal and environmental factors. M did not consider the leak caused the subsidence given:  it was isolated to one corner of the home, whereas the entire side of the home had subsided, and  the soil type would have expanded, not subsided. Together, the level survey and the water leakage report by J, demonstrate that the two possible causes identified by M did not cause damage to the Applicants ’ home. This is because:  While no soil test was conducted, both M and MP agreed the soil was likely to be reactive such that it expanded with moisture and shrunk when moisture was reduced.  Uplifting at the site of the cracking would need to be caused by a leak near the location of the crack. However, J’s report indicates the leak was in the far north west corner, away from the main crack. Despite the leak, this part of the home subsided rather than buckled from expa nding soil.  The level survey shows the southern side of the home was subject to only minor subsidence (-24) compared to the northern side (-207). I conclude the cause of the damage was settlement of the foundation soil on the northern side of the crack (the north-western side of the building). As such, the Applicants have not established that the damage was covered by an insurable event. Water from leaking pipe did not cause or contribute to damage The Applicants say the sewer drainage leak which was identified on the northern side of the home was significant, and contend it must have contributed to the moisture related soil movement and settlement on that side of the home. However, MP confirmed that:  The leak detected was confined to the north corner of the home, while the settlement was on the entire north-western side of the building.  Increased moisture in the clay soil would cause swelling in the soil, resulting in heave-related damage. It would not result in settlement of the soil, which is what occurred on the north-western side of the building.  The soil in the area of the leak was not significant in that any added moisture from the leak was less than that which was being extracted from seasonal and environmental factors. After considering the evidence provided, I conclude that the leak from the water pipe did not cause or contribute to the settlement of the soil which resulted in the damage to the Applicants’ home. Case No: 353989 Determination Page 4 of 5 3 Supporting information 3.1 Reports from respective parties Re port Key points Applicants’ engineer “M” 25 May 2013  Based on site observations, it is suspected that the structural foundations have been subjected to signific ant movements which has resulted in damage to the ceiling and concrete floor with the front south eastern room , misalignment of the window and door fixings (mainly on the eastern side), and cracking of the brick veneer wall on the western side of the home .  T he soil in the area consists of shallow red brown clay with a thin lime or calcrete layer on calcareous bedro ck. These soils are characterised to be of medium to high reactivity .  I t is suspected the structural foundations of the Applicants’ home have been subjected to significant movement .  T he cracking is due to a prying force pulling apart of the ceiling and f loor.  T he prying force could be due to eit her upswelling of the founding soil under the slab at the crack location (which may be due in part to local inclusion of wat er into the soil beneath the slab), or subsidenc e in the founding soil at the southern end of the building .  I f excess water entered the soil below the slab, the clay soil would swell, resulting in an upwards reaction on the slab. This would cause the slab to bow upwards and crack on its upper surface (if the bending capacity of the slab was ins ufficient), and movement of the structure supported on the slab.  I f soils at the southern end of the building lost bearing capacity and subsided, the foundations would sink. This would result in rotational movement along the line of the area where the cra ck has propagated resulting in the damage seen.  To determine the root cause of the damage, an investigation of the existing pipework for local leakage is recommended. If no pipe leak is detected, the soil should be tested to determine the exact characteristics of the soil profile along the southern foundation. FSP ’s engineer “MP” 30 August 2013  A level survey indicates that the part of the building north of the major crack has settled relative to its originally constructed position, while the part on the southern side has remain relatively stable.  Expanding and shrinking of the soil will lead to upward heaving and downward settling movements (res pectively).  The soil in the vicinity is likely to include reactive clay, which will expand if its mo isture level increases (and shrink it the moisture level decreases).  The actual foundation conditions at the site and their relative moisture can be objectively determined by carrying out a soil test at the site. The expert could organis e such testing if w arranted.  The home consists of two constructions; an original northern construction and a southern addition constructed at a later date. Case No: 353989 Determination Page 5 of 5 Re port Key points  The junction bet ween the two constructions is the location of the significant cracking.  The cracking and movement has b een caused by gradual settlement of the home’s foundation soil on the northern side, most likely caused by gradually reducing moisture content as a result of seasonal and environmental factors.  A leak test undertaken by “J” revealed a leak in the home’s se wer drainage. The leakage rate under test conditions was 7 litres per minute.  The sewer leak has likely existed for some time and does not appear to be causing any heave - relat ed cracking or movement and is therefore not the cause of the observed damage.  Ho wever, because the sewer leak could possibly cause future heave - related damage, it is should be repaired. 3.2 Product Disclosure Statement “ What we cover – insured events You are covered for damage or loss to your home building occurring during the period of cover and caus ed by the following events: Liquid escaping suddenly and unexpectedly from a: Water main, drain, fixed pipe…” “What we do not cover – general exclusions You are not covered under any section of the policy for damage, loss, cost or liability caused by or arising from or involving: … soil movement or settlement. ”

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.