Home / Financial Firm (Unknown - Insurer) / Determination 353143

Determination 353143

Garage cracking from burst pipe denied under earth movement and settling exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2014-09-26
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's farm insurer denied a claim for cracking to a garage after a burst water pipe, attributing the damage to long-term soil movement and tree roots. AFCA accepted the engineer's evidence that the pipe did not cause the damage, found the exclusions applied, and ordered no payment.

Where accidental damage cover is established, the insurer may rely on the earth movement and settling exclusions if it shows the damage was caused by excluded long-term foundation movement.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim Determination Case No: 353143 Determination Page 1 of 5 Case number : 353143 24 September 2014 1 Overview 1.1 Dispute The Applicant held a farm insurance policy with the Financial Services Provider (FSP) under which he lodged a claim for cracking to a garage caused by a burst pipe. The FSP denied the claim on the basis the damage did not occur as a result of leakage of water from the pipe, rather it was as a result of occurrences excluded under the terms of the policy. 1.2 Issues and key findings Has the Applicant established a prima facie claim? As there is no dispute there was a burst pipe at the Applicant‟s property and the policy provides cover for damage arising from a leaking pipe, the Applicant has established a prima facie claim. Is the FSP entitled to deny the claim? The FSP is entitled to deny the claim because:  there is insufficient evidence to show the water which escaped from the burst pipe caused the soil to heave resulting in the cracking to the garage building  the cause of the damage is most likely the result of occurrences excluded under the terms of the policy. 1.3 Determination This Determination is in favour of the FSP. The FSP was entitled to deny the Applicant‟s claim and is not required to pay the cost of repairing the damage to the garage building. Case No: 353143 Determination Page 2 of 5 2 Reasons for Determination 2.1 Has the Applicant established a prima facie claim? Although the FSP in its Notice of Response has referred to the cover being a defined events cover, it is clear from the policy schedule that the Applicant‟s cover is accidental damage cover. Under Part B Section A Home Cover, it clearly identifies two types of cover being available. One is Defined Events Cover and the other is Accidental Damage Cover. The cover type selected is shown on the schedule. The schedule provided identifies a number of different properties and the cover varies for the different properties. The property that is subject of this dispute according to the schedule is covered for accidental damage. The policy does not define accidental damage however given its usual meaning, it means „ unforeseen and unexpect ed‟ damage. There is no dispute that at some time after 20 November 2012, a water pipe burst at the Applicant‟s property affecting the garage and remained undetected until the Applicant‟s return to the pr operty on or about 22 December 2012. There is no doubt that the burst water pipe would be considered unforeseen and unexpected and accordingly I am satisfied that the Applicant has established a prima facie claim under the terms of the policy. 2.2 Is the FSP able to establish the application of an exclusion? The policy specifically identifies under the heading „What you are not insured for‟ a number of exclusions including exclusions caused by:  earth movement, vibration, erosion, landslide or subsidence (except when caused by earthquake)  settling, shrinkage or expansion in the building, its foundations or any walls or pavements  tree roots. The FSP maintains that the building movement was due to differential changes in the moisture contents of the foundation soils and not due to the burst water pipe. There is evidence of damage pre-existing or pre-dating the burst water pipe event Following lodgement of the claim, the FSP appointed a loss adjustor to inspect the property. The loss adjustor attended the property on 27 June 2013. The loss adjustor noted that the concrete slab/floor of the garage had subsided. The report identifies gaps between the frame and the wall but also identified that where the fascial boards meet at the northwest corner of the garage, there was a gap of approximately 4cms which appears to have been previously filled with a compound which they Case No: 353143 Determination Page 3 of 5 believe pre-dated the burst water pipe event. The loss adjustor recommended the appointment of an engineer. The FSP arranged for the attendance of an engineer at the property on 29 July 2013. F provided a detailed report and observed that the damage to the building was not entirely recent and that the building had been subject to ongoing, long term movement in particular noting evidence of previous attemp ts to repair damage and evidence of movement. Although the Applicant refers to some of the damage as being minor cracking, the Applicant has provided no evidence to dispute the findings of the engineer. Damage was caused by ongoing long-term differential movements of footings due to differential changes in the moisture content of the soil After an inspection of the Applicant‟s property, F concluded the damage to the garage arose from:  the reactivity of the soil at the site  tree root drying of the foundation soils  the drought conditions between 1997 and 210 followed by the return of normally expected rainfall  the recent very hot and dry summer  seasonal changes in the soil moisture content. The movement was not caused or contributed to by the burst water pipe but had resulted from ongoing long-term foundation movements caused by the combination of factors identified above. The Applicant has challenged these findings and believes that the soil moisture content changed due to the burst water pipe and that this se verely escalated the movement in the garage wall in the short term. In response, engineer F noted that if moisture content increases in the clay soils, it will cause the soil to swell causing relative “heave” of the building footings. If the moisture content decreases, then the clay soils will shrink causing relative settlement of the building footings. According to F no localised heave was identified along the western side of the garage as would be expected if the leak event had increased the moisture content of the foundation soils. The Applicant was given the opportunity of providing his own expert evidence to support his statements but has elected not to do so. In the absence of any evidence to the contrary, I accept the evidence of the engineer and accept that the damage was due to ongoing long term foundation soil movement as identified by F and not as a result of the burst water pipe. The policy exclusions relating to earth movement, subsidence and settling, shrinking or expansion in the building, its foundations or any walls together with the exclusion relating to damage caused by tree roots applies in this case to defeat the Applicant‟s claim. Case No: 353143 Determination Page 4 of 5 3 Supporting information 3.1 Part B - Farm Insurance Policy Terms and Conditions Record Key points Section A – Home Cover Accidental Damage Cover We will pay for accidental loss of or damage to your Building or Contents at the Address other than the Occurrences or items referred to in “What you are not insured for”. What you are not insured for under Section A – Ho me Cover, we will not pay for:  Loss of or damage to your property caused by: … - earth movement, vibration, erosion, landslide or subsidence (except when caused by earthquake) - settling, shrinkage or expansion in the Building, its foundations, or any walls or pavements … - tree roots. Renewal Schedule 5 March 2014 The Claim Report 27 March 2013 Loss Adjustor CL‟s Report July 2013 We have no reason to doubt the Insured has suffered an Insurable Event in December 2012 when a water pipe burst and water kept pumping because of the pressure pump attached to the pipe. However, we noted signs indicative of a previous problem with the g arage, which would appear to pre - date the date of loss of this claim and recommend an Engineer be appointed to prepare a Causation Report and a Scope of Works for the required reinstatement. Engineering I nvestigation Report 9 August 2013 The floor levels survey did not identify any localised heave at the reported leak location along the western side of the garage; localised heave would be expected if the leak event had increased the moisture content of the foundation soils. The following observations also indicate that the damage to the building is not entirely recent and that the building is subject to on - Case No: 353143 Determination Page 5 of 5 going , long term movements:  The previous attempts to repair the wall cracks at the southern end of the garage .  The foam packed into the control joint in the southern wall of the g arage.  The gap at joint in paving slab at northern side of house that has previously filled/repaired with mortar.  Evidence of movement between the paving slab and the house in areas remote from the distressed garage. Therefore it is FMG‟s opinion that the leak event has not caused, nor contributed to, the observed distress to the garage. Instead it is FMG‟s opinion that the building movement and associated building distress has been caused by on - going long - term differe ntial movements of the footings due to differential changes in the moisture contents of the foundation soils due to a combination of the following: a) The reactivity of the soils at this site. b) Tree root drying of the foundation soils. In particular by the tre es located near the northwest corner of the building. c) The relatively low rainfall (drought conditions) in Victoria from 1997 to 2010, followed by the return of “normal” rainfall levels recently. d) The recent very hot and dry summer. e) Seasonal changes in soil moisture contents.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.