Home / Financial Firm (Unknown - Insurer) / Determination 353143
Determination 353143
Garage cracking from burst pipe denied under earth movement and settling exclusions
Summary
The applicant's farm insurer denied a claim for cracking to a garage after a burst water pipe, attributing the damage to long-term soil movement and tree roots. AFCA accepted the engineer's evidence that the pipe did not cause the damage, found the exclusions applied, and ordered no payment.
Where accidental damage cover is established, the insurer may rely on the earth movement and settling exclusions if it shows the damage was caused by excluded long-term foundation movement.
Subjects and remedies
home or building damageno remedy
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of
claim
Determination
Case No: 353143 Determination Page 1 of 5
Case number : 353143 24 September 2014
1 Overview
1.1 Dispute
The Applicant held a farm insurance policy with the Financial Services Provider
(FSP) under which he lodged a claim for cracking to a garage caused by a burst
pipe.
The FSP denied the claim on the basis the damage did not occur as a result of
leakage of water from the pipe, rather it was as a result of occurrences excluded
under the terms of the policy.
1.2 Issues and key findings
Has the Applicant established a prima facie claim?
As there is no dispute there was a burst pipe at the Applicant‟s property and the
policy provides cover for damage arising from a leaking pipe, the Applicant has
established a prima facie claim.
Is the FSP entitled to deny the claim?
The FSP is entitled to deny the claim because:
there is insufficient evidence to show the water which escaped from the burst
pipe caused the soil to heave resulting in the cracking to the garage building
the cause of the damage is most likely the result of occurrences excluded
under the terms of the policy.
1.3 Determination
This Determination is in favour of the FSP.
The FSP was entitled to deny the Applicant‟s claim and is not required to pay the
cost of repairing the damage to the garage building.
Case No: 353143 Determination Page 2 of 5
2 Reasons for Determination
2.1 Has the Applicant established a prima facie claim?
Although the FSP in its Notice of Response has referred to the cover being a
defined events cover, it is clear from the policy schedule that the Applicant‟s cover
is accidental damage cover.
Under Part B Section A Home Cover, it clearly identifies two types of cover being
available. One is Defined Events Cover and the other is Accidental Damage
Cover. The cover type selected is shown on the schedule.
The schedule provided identifies a number of different properties and the cover
varies for the different properties. The property that is subject of this dispute
according to the schedule is covered for accidental damage.
The policy does not define accidental damage however given its usual meaning, it
means „ unforeseen and unexpect ed‟ damage.
There is no dispute that at some time after 20 November 2012, a water pipe burst
at the Applicant‟s property affecting the garage and remained undetected until the
Applicant‟s return to the pr operty on or about 22 December 2012.
There is no doubt that the burst water pipe would be considered unforeseen and
unexpected and accordingly I am satisfied that the Applicant has established a
prima facie claim under the terms of the policy.
2.2 Is the FSP able to establish the application of an exclusion?
The policy specifically identifies under the heading „What you are not insured for‟
a number of exclusions including exclusions caused by:
earth movement, vibration, erosion, landslide or subsidence (except when
caused by earthquake)
settling, shrinkage or expansion in the building, its foundations or any walls or
pavements
tree roots.
The FSP maintains that the building movement was due to differential changes in
the moisture contents of the foundation soils and not due to the burst water pipe.
There is evidence of damage pre-existing or pre-dating the burst water pipe
event
Following lodgement of the claim, the FSP appointed a loss adjustor to inspect
the property.
The loss adjustor attended the property on 27 June 2013. The loss adjustor noted
that the concrete slab/floor of the garage had subsided. The report identifies gaps
between the frame and the wall but also identified that where the fascial boards
meet at the northwest corner of the garage, there was a gap of approximately
4cms which appears to have been previously filled with a compound which they
Case No: 353143 Determination Page 3 of 5
believe pre-dated the burst water pipe event. The loss adjustor recommended the
appointment of an engineer.
The FSP arranged for the attendance of an engineer at the property on 29 July
2013. F provided a detailed report and observed that the damage to the building
was not entirely recent and that the building had been subject to ongoing, long
term movement in particular noting evidence of previous attemp ts to repair
damage and evidence of movement.
Although the Applicant refers to some of the damage as being minor cracking, the
Applicant has provided no evidence to dispute the findings of the engineer.
Damage was caused by ongoing long-term differential movements of
footings due to differential changes in the moisture content of the soil
After an inspection of the Applicant‟s property, F concluded the damage to the
garage arose from:
the reactivity of the soil at the site
tree root drying of the foundation soils
the drought conditions between 1997 and 210 followed by the return of
normally expected rainfall
the recent very hot and dry summer
seasonal changes in the soil moisture content.
The movement was not caused or contributed to by the burst water pipe but had
resulted from ongoing long-term foundation movements caused by the
combination of factors identified above.
The Applicant has challenged these findings and believes that the soil moisture
content changed due to the burst water pipe and that this se verely escalated the
movement in the garage wall in the short term.
In response, engineer F noted that if moisture content increases in the clay soils,
it will cause the soil to swell causing relative “heave” of the building footings. If the
moisture content decreases, then the clay soils will shrink causing relative
settlement of the building footings. According to F no localised heave was
identified along the western side of the garage as would be expected if the leak
event had increased the moisture content of the foundation soils.
The Applicant was given the opportunity of providing his own expert evidence to
support his statements but has elected not to do so.
In the absence of any evidence to the contrary, I accept the evidence of the
engineer and accept that the damage was due to ongoing long term foundation
soil movement as identified by F and not as a result of the burst water pipe.
The policy exclusions relating to earth movement, subsidence and settling,
shrinking or expansion in the building, its foundations or any walls together with
the exclusion relating to damage caused by tree roots applies in this case to
defeat the Applicant‟s claim.
Case No: 353143 Determination Page 4 of 5
3 Supporting information
3.1 Part B - Farm Insurance Policy Terms and Conditions
Record Key points
Section A – Home Cover
Accidental Damage Cover
We will pay for accidental loss of or
damage to your Building or Contents at
the Address other than the Occurrences
or items referred to in “What you are not
insured for”.
What you are not insured for under
Section A – Ho me Cover, we will not pay
for:
Loss of or damage to your property
caused by:
…
- earth movement, vibration, erosion,
landslide or subsidence (except when
caused by earthquake)
- settling, shrinkage or expansion in the
Building, its foundations, or any walls
or pavements
…
- tree roots.
Renewal Schedule 5 March 2014
The Claim Report 27 March 2013
Loss Adjustor CL‟s Report July 2013 We have no reason to doubt the Insured has
suffered an Insurable Event in December
2012 when a water pipe burst and water
kept pumping because of the pressure pump
attached to the pipe.
However, we noted signs indicative of a
previous problem with the g arage, which
would appear to pre - date the date of loss of
this claim and recommend an Engineer be
appointed to prepare a Causation Report
and a Scope of Works for the required
reinstatement.
Engineering I nvestigation Report
9 August 2013
The floor levels survey did not identify any
localised heave at the reported leak location
along the western side of the garage;
localised heave would be expected if the
leak event had increased the moisture
content of the foundation soils.
The following observations also indicate that
the damage to the building is not entirely
recent and that the building is subject to on -
Case No: 353143 Determination Page 5 of 5
going , long term movements:
The previous attempts to repair the
wall cracks at the southern end of
the garage .
The foam packed into the control
joint in the southern wall of the
g arage.
The gap at joint in paving slab at
northern side of house that has
previously filled/repaired with mortar.
Evidence of movement between the
paving slab and the house in areas
remote from the distressed garage.
Therefore it is FMG‟s opinion that the leak
event has not caused, nor contributed to, the
observed distress to the garage. Instead it is
FMG‟s opinion that the building movement
and associated building distress has been
caused by on - going long - term differe ntial
movements of the footings due to differential
changes in the moisture contents of the
foundation soils due to a combination of the
following:
a) The reactivity of the soils at this site.
b) Tree root drying of the foundation
soils. In particular by the tre es
located near the northwest corner of
the building.
c) The relatively low rainfall (drought
conditions) in Victoria from 1997 to
2010, followed by the return of
“normal” rainfall levels recently.
d) The recent very hot and dry summer.
e) Seasonal changes in soil moisture
contents.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.