Home / Financial Firm (Unknown - Insurer) / Determination 352913
Determination 352913
Denial of claim for water leakage, mould and cupping damage
Summary
The applicants claimed under their home insurance for water, mould and cupping damage after the FSP denied the claim. AFCA found the damage was caused by concurrent excluded causes, including ventilation and floor construction, and that the FSP's conduct was not unsatisfactory.
Under the Wayne Tank principle, where an excluded cause operates concurrently with a covered cause, the exclusion prevails and defeats the claim.
Issues
- Claim denial primary · not upheld
“The FSP is entitled to deny the claim as the damage was caused by events excluded from cover.”
- Poor claim handling secondary · not upheld
“I do not accept that the FSP acted unreasonably or in a misleading manner in its approach to the claim.”
Subjects and remedies
home or building damageno remedy
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building & Contents - FSP Decision -
Denial of Claim
Determination
Case No: 352913 Determination Page 1 of 16
Case number: 352913 1 7 November 2014
Overview
Dispute
In January 2011 the Applicants made a claim under their home building and
contents insurance policy, which was issued by the Financial Services Provider
(FSP). They claim water from broken stormwater pipes pooled under their home,
resulting in damage to the home and contents and the spread of mould within the
home. They claim the mould has damaged the building and contents, as well as
ad versely impacted the Applicants‟ health.
The FSP denied the claim as it says the damage was caused by poor ventilation
and poor workmanship.
As the Applicants contend the damage has resulted from water leakage which is
an insured event, they seek a revi ew of the FSP‟s decision.
They also contend the FSP‟s claims management is inadequate and has led to
delays which caused deterioration of the building and caused the mould to worsen
which adversely affected the Applicants‟ health.
Issues and key findings
Is the FSP entitled to deny the Applicants’ claim?
The FSP is entitled to deny the Applicants‟ claim as they have not established the
loss and damage was caused only by the leaking pipes. Rather the information
provided establishes on the balance of probabilities that the loss and damage was
caused by causes which are excluded from cover. The loss or damage was due
to a lack of ventilation under the house which meant that mould developed
because of damp conditions within the home structure. The cupping of the floor
was caused by this cause and by poor workmanship when the floor was installed.
Was the FSP’s conduct unsatisfactory?
The material provided does not support the Applicants‟ allegations that the FSP‟s
conduct was unsatisfactory.
Determination
The Determination is in favour of the FSP.
The FSP is entitled to deny the claim and need take no further action.
Case No: 352913 Determination Page 2 of 16
Reasons for Determination
I have decided this case on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous FOS decisions. I have taken into
account all the material submitted by the parties. I am satisfied that the
documentation I have relied on has been provided to both parties.
2.1 Is the FSP entitled to deny the Applicants’ claim?
The Applicants must establish that the proximate cause of the damage was
water leaking from storm water pipes
The Applicants lodged a claim on 21 January 2011, because water from an
unknown source was pooling under their home. They observed cupping and
mould/mildew developing in the home and on the contents. They say the mould
also adversely impacted on the Applicants‟ health.
The Applicants have the onus of establishing the loss or damage to the property
was caused by an event covered by the policy. Once the Applicants ha ve done
so, the onus then reverts to the FSP to establish the loss or damage is not
covered because of the application of a policy condition or exclusion.
The Applicants contend the claim relates to an insured event, namely, water
leakage from storm water pipes. In support of their contentions the Applicants
have provided considerable material and have challenged the various reports
obtained by the FSP, in addition to criticising the FSP‟s submissions based on
those reports.
The parties have obtained a number of reports from various experts
The FSP‟s assessor, a building services company (TB) assessed the property on
2 February 2011 and 8 June 2011.
The assessor saw the mould and cupping in the floor. He noted mildew was
present in one of the bedrooms, low moisture levels in the flooring, and no mildew
was detected on the carpet but it was seen on the second visit.
TB said the areas of damaged floating floor appeared to be related to the damp
conditions. TB also said:
“An inspection under the house indicated water pooling in several low lying areas but
no indication of a water leak from the visible pipe work or sewerage pipe.”
TB suggested a leak specialist be engaged but instead the Applicants had already
engaged a plumber.
R also inspected the house on 1 March 2011 and said there is not a lot of mould
and suggested it was from rising damp under the house and condensation from
the shower. However the latter cause was eliminated as new fans did not alleviate
the mould.
Case No: 352913 Determination Page 3 of 16
R inspected the house again on 8 June 2011 and noted mould in the bedroom but
not in the carpet and said the moisture reading in the floor was at the high end of
normal. R said the condensation in the house is due to no ventilation.
The FSP inspected the house this day too and noted the bedside was mouldy as
was a suitcase under the bed.
C also inspected the house in June and didn‟t identify any visible mould or smell
although C did no formal testing. C did note the state on the western side of the
house and said this impacted on moisture levels and rising damp.
The Applicants‟ plumber (SB) inspected the property and made a report on 7
March 2011. He concluded the joints in the eastern pipe appeared to have failed
as a result of movement. This was the cause of the reports by the Applicants of
constant wetness under the house - puddles of water and a muddy subfloor.
However on the day of inspection the plumber found the subfloor dry on both the
east and west side of the house save for rings of moist ground at the joints of the
east pipe. He tested both the east and west pipes and only replaced the east pipe
in April 2011 as he saw no water pooling on the west side. The inspection of the
west side was visual only.
SB later confirmed the eastern storm water earthenware pipe with cement mortar
joints was severely damaged at the majority of joints.
IC says the damage is caused by poor sub floor ventilation and unsuitable
installation of the new floor
A building consultant was engaged by the FSP. (IC) inspected the house on 10
June 2011, and read the report from the plumber. He saw moisture (not
saturation) on the east side of the subfloor of the house, and moisture staining to
brick piers. He noted high humidity levels in the boards outside the main
bedroom. He said there was “virtually no sub floor ve ntilation” on the north, west
and south sides of the house and dead airspace in 50% of the subfloor.
IC reported on 17 June 2011:
there are issues with site drainage and sub -floor ventilation which causes the
cupping of the timber floor as the original floor absorbs moisture while the top
floor has air
the timber floor should not have been laid this way
a lack of ventilation has not allowed for the reasonable drying of the soil in the
sub-floor region, irrespective of the cause of the leaks
if the floor is always wet then there is not just a problem with the pipes but run
off seepage too.
IC emailed the FSP on 18 July 2011 about the testing of the western stormwater
line and concluded it was leaking too and water ran to the eastern side of the
house so the repair of the eastern pipe only had not alleviated water under the
house if it rained.
IC notes that the water from the pipes did not come into contact with the upper or
lower floor or the bearers or joists. He essentially repeats his opinion that the floor
Case No: 352913 Determination Page 4 of 16
would not have cupped if the new floor had not been overlaid the old floor and if
there was better ventilation in the subfloor.
IC inspected again on 14 September 2011 and noted:
the western line had been replaced with PVC a week earlier
there was dampness and increase in mould growth especially on the west
side of the house
he agrees there is damp in the subfloor causing mould but says even if the
western pipe had been leaking and was associated with moisture in the sub -
floor he reiterates this is compounded by a lack of sub-floor ventilation.
The Applicants continued to be concerned that the mould in their home was
causing health issues. As a result, the Applicants obtained a mould assessment
report from an expert on the topic (M). M provided a report dated 26 September
2011, which included a mould analytical report from “ML”, also dated 26
September 2011.
M says there is mould in the home and points out it is worse where the
ventilation is worse
M saw mould in the bedroom and lounge but also commented that there was no
mould on the eastern side of the house indicative of high ventilation under that
side of the house.
ML concluded the levels of identified mould in the home were high to very high
and therefore it constituted a health risk.
M provided a further report dated 25 October 2011 concerning the further testing
and remedial work needed which he said nay cost $20,000.
M subsequently provided another report, dated 10 July 2014, as a result of the
Applicants asking for comment on the inspections M carried out in 2011, three
years earlier. M said under the house was dry when M attended on 19 September
2011, but there was evidence of where the water had been running previously. M
noted the damaged western pipe was repaired in August 2011.
M said the physical damage to the Applicants‟ property was not due to a lack of
ventilation (although M conceded the lack of ventilation was less than optimum)
but due to high water activity. M said the damage was due to water ingress under
the home and M referred to the mould and swelling on a particular piece of
furniture in support of this contention that the water level must have been high.
DE does not comment on the cause of damage
An engineer DE also inspected the property at the Applicants‟ request i n March
2014 and said the Applicants had controlled the stormwater from the house. DE
took photographs of the subsoil which was now severely cracked. He said the soil
was highly reactive to moisture.
On balance the material supports that inadequate ventilation and poor
construction of the floor were the cause of the mould and cupping
From the information available the following chronology is noted:
Case No: 352913 Determination Page 5 of 16
2005 house purchased and was bricked in (see Applicants‟ photographs) .
Approx 2006/7 new floor put in (Applicant s‟ chronology) and JB noted
newspaper under floor was dry (JB letter 17 February 2014).
2009 - no mould before then (see M report 10 July 2014).
Approx June 2009 water noticed under house (see FSP file note 8 June
2011).
Approx June 2009 cupping started (see IC report 17 June 2011)
Cupping began about the same time as front path jack hammered near
western line.
Approx June 2009 mould noted (see IC report 17 June 2011).
Approx 2009 symptoms of environmental allergies began (Dr A‟s report) .
Beginning 2011 discovered sub floor damage and reported it to FSP (letter to
FSP 15 July 2011).
February 2011 cupping noted by assessor and some mould.
4 March 2011 plumber under house and it is dry save for ri ngs near joints in
eastern pipe.
March/April 2011 eastern storm water pipe replaced.
May 2011 subfloor dry until rain (letter to FSP 15 July 2011).
May to August 2011 44 days of rain (BOM records provided by Applicants).
June 2011 FSP noted mould.
June 2011 IC measured high moisture levels where there was mould. Soil
moist.
June 2011 fans made no difference (letter to FSP 15 July 2011).
I July 2011 male Applicant tests with IC and works out western line leaking
too.
15 July 2011 male Applicant says house now dry (see FSP file note) (and
letter to FSP 15 July 2011).
August/ September 2011 western line replaced with PVC.
14 September 2011 IC inspected again and noted dampness and mould
worse on west of house.
19 September 2011 M identifies high level of mould in the west of the house
Noted it was dry under the house.
4 March 2014 DE photographs subfloor cracked.
Despite the Applicants having repaired the eastern storm water pipe in or about
April 2011 and the western pipe in or about August/September 2011, mould within
the house and in the contents still remai ned a problem. IC‟s two reports have fully
examined the possible causes for the growth of mould and if the Applicants‟
identified cause is fixed (the leaking pipes) then the possibility of another cause
must be explored.
I accept that IC did not go under the entire house but the photographs he took
indicate he went under the eastern side of the house. He is a building consultant
and is qualified to comment on the issues in dispute. IC‟s reports provide an in
depth analysis of the problem, and the findings on this issue are therefore highly
persuasive. IC‟s findings indicated the way the floor was built and the lack of
ventilation under the floor were largely the reason for the cupping and the growth
of mould. These causes are excluded from cover.
Case No: 352913 Determination Page 6 of 16
R also comments on the cause and agree it is because of the lack of ventilation
under the house.
Further, there is no evidence that the floor or area under the floor was actually
touched by water at any time.
When M carried out an assessment of the Applicants‟ pro perty, the objective was
to determine the extent of fungal damage and ML‟s report‟s objective was to
identify the mould and bacterial growth. This is the main extent of M‟s expertise.
However even M identifies the lack of mould on the east side of the house and
says it is because the east side is better ventilated. He later says that the lack of
ventilation would not cause the moisture issues identified although he still
concedes “ the ventilation on the high side of the block is less than I would like to
s ee.”
On balance I prefer the expert opinion of IC as he has the expertise to comment
and has been consistent all along in his view. M‟s expertise is in mould
remediation and there is ambivalence when one compares the first report with the
second about the cause of damage.
DE does not comment on the cause of the damage.
The Applicants’ criticism of IC does not derogate from his opinion
The Applicants say the FSP‟s consultants have provided inaccurate information
and have been instructed to intentionally mislead. The Applicants say the damage
is not limited to the western side but their own expert M says the damage is worse
on the western side. That is highly relevant due to the state of the sub floor on the
western side as commented on by M.
The Applicants say that all timber floors cupped but this is also due to the way it
was laid. They criticise the conclusions of IC as IC didn‟t go under house but only
looked under the house from the eastern side only. They contend therefore he
misunderstands the subfloor layout. The Applicants have produced photographs
and submit they show there is ventilation on the northern side, a vent in the
laundry and the rear southern vent shows an unobstructed path through the
northern openings
I have considered those photographs. However I have also carefully considered
the photographs taken by IC and his reports in totality and on balance I accept his
opinion as he is independent and I am satisfied that he has the expertise to
comment that the sub floor is badly ventilated and that the floor should not have
been built in the way that it was.
I accept that IC does not mention the testing of the western line in his reports but I
have considered his email to the FSP about the testing and do not accept that he
has provided inaccurate information when one considers the totality of his reports
and emails.
I also accept that the sub floor was not always damp and that the newspaper was
dry when inspected by JB in or about 2006/7 but this does not establish that the
sub floor is not properly ventilated. It merely establishes the sub floor may have
Case No: 352913 Determination Page 7 of 16
been dry at that time as the pipes were not damaged then or if they were
damaged that it had not been raining.
The principle in Wayne Tank applies to defeat the claim
Both parties have commented on the rule in the Wayne Tank legal decision. This
decision provides that where there are two concurrent contributing causes and
one is excluded from cover under the policy, the exclusion prevails and the FSP is
entitled to deny the claim.
The FSP therefore argues that even if it is accepted that the leaking pipes were a
cause of the loss as the mould and inadequate ventilation were also proximate
causes of the loss and these are excluded under the terms of the policy, then the
exclusions apply to defeat the Applicants ‟ claim.
The Applicants rely on M who said concurrent events were not operating as there
was no mould or cupping until 2009. I accept the damage was not noted then but
the most probable explanation is that the pipes were not leaking at that time.
The Applicants do not complain of the damage until 2011. The question arises as
to what was the proximate cause of the damage then. If it was the leaking pipes
then this caused the mould and the policy responds. But I am persuaded that the
expert material establishes that when pipes leaked, there were other causes of
the damage operating at the same time – the inadequate ventilation under the
house and the way the floor was constructed. I also accept that these causes are
excluded from cover as they represent faulty design and workmanship that the
Applicants knew about or should have reasonably known about as they were
responsible for the floor construction and other work done to the house.
Accordingly I accept that the principle in Wayne Tank operates to defeat the
claim.
The FSP is entitled to deny the claim as the damage was caused by events
excluded from cover
The Applicants have not established on the balance of probabilities that the sole
cause of the loss or damage was the leaking pipes. Rather from the material
provided and for the reasons stated I am satisfied on the balance of probabilities
that the damage was caused by causes operating concurrently which causes are
excluded from cover under the policy. Accordingly, the FSP was entitled to deny
the claim.
Was the FSP’s conduct unsatisfactory?
The material provided does not support the Applicants’ allegations
The Applicants have made a number of adverse comments about the FSP. They
say the FSP used delaying tactics; its consultants have written misleading reports;
its consultants have not diligently inspected the house and damage; and the FSP
is holding the Applicants “to ransom in a toxic environment under severe duress”.
The Applicants further allege the FSP has only released selective information that
suits its position and hid the balance of information or influenced the outcome or
Case No: 352913 Determination Page 8 of 16
instructed their consultants to intentionally mislead prior to visiting the house.
They say this is a pattern of behaviour relying on a website detailing anot her claim
by another insured against the FSP.
They say the mismanagement has led to an unnecessary prolongation of the case
and has increased their loss and damage and adversely affected their health.
The FSP says that the Applicants have misunderstood the terms of the policy and
what has been communicated to them in relation to the claim. The FSP says it
has acted in good faith at all times, investigated and kept them informed and even
though the cover is outside the policy have made offers for part of the claim which
offer was not accepted.
Having carefully read the information provided, I am unable to accept the
Applicants‟ assertions. Rather, I am persuaded that the material provided
establishes the FSP responded in a timely manner when the Applicants lodged
their claim. Further, from the information provided I do not accept that the FSP
acted unreasonably or in a misleading manner in its approach to the claim and the
dispute.
Case No: 352913 Determination Page 9 of 16
Supporting information
3.1 Policy Provisions
“ The events we cover
…
Water and oil leaks
If loss or damage is caused by water or oil leaking or escaping from an item shown
in this section.
Covered
► water leaking or escaping from:
- house gutters, drainpipes or pipes
…
General exclusions
The exclusions shown in this section apply to all cover under your policy.
We don’t cover
Loss, damage, injury or death arising from:
…
► mould
…
► atmospheric conditions or extreme temperature
…
Maintaining and occupying your home
We don‟t cover loss, damage, injury or death arising from:
…
► faulty design or workmanship that you knew about or should have reasonably
known about
…”
3.2 Various reports/documentation –
Report Dr A
17 October 2011
Dr A is the male Applicant‟s GP .
The male Applicant has symptoms (symptoms for the last 2
years) which indicate “environmental allergy” most likely
caused by exposure to mould in his old house .
Recent blood test ruled out allergy .
Report Dr B
29 September 2014
The home situation is leading to significant illness .
Photograph of affected toe nails .
Case No: 352913 Determination Page 10 of 16
FSP’s assessor’s
reports
Various
Inspected property 2 February 2011 and 8 June 2011 to
confirm cause of damage and cost to repair .
Investigated why water pooling under Applicants‟ house
Applicants unsure why water pooling and home and contents
have mould .
Applicants thought next door neighbors‟ storm water pipe may
be the cause .
Observed flooring cupping in various rooms due to moisture .
Cupping consistent throughout house and appears to be
related to damp conditions .
Some mould seen and low level moisture levels detected in
flooring .
Appears to be related to damp conditions .
No undue accumulation of moisture in grassed area soil .
Inspected under house – noted water pooling in certain low
lying areas but no indication of water leak from visible pipes;
and no sign of cracked pipes in earthenware pipes along west
side of house .
Because of the concreting and the position of pipes, did not
believe next door‟s piping related to problem .
No leaks from water pipes or any excess water usage .
Leak detection speciali st to be engaged to investigate pipes .
Estimated cost of repairs $24,909 .
On inspection 8 June 2011 noted mildew in listed contents, no
mildew detected in carpet, low moisture level detected in
flooring .
FSP file note
1 March 2011
R attended for FSP that day. FSP‟s notes say:
There is not a lot of mould/not toxic/ no health risk .
Humidity inside 12% higher than outside .
Mildew on sills not on glass .
Caused by condensation from shower and rising damp under
house .
FSP file note
9 March 2011
Read plumb er‟s report and will fix damage from pipe but not
pipe itself .
FSP file note
10 May 2011
Repairs to pipe completed but still a lot of water under house
and need to wait for sub floor to dry out before tenders are
obtained.
FSP file note
1 June 2011
On e pipe fixed but other leaking but he can‟t afford to fix it and
there is still water under house .
Male Applicant says house making him sick .
Must mitigate loss so mould won‟t grow .
Will inspect and cash settle so pipe can be fixed .
FSP file note
8 June 2011
FSP attended house and west pipe still not fixed .
Was told noticed water under the house about 2 years ago .
Inspected and noted floating floors, bedside mouldy, suitcase
under bed mouldy .
Inspected and measured floor and carpet and agreed to send
out R again .
FSP file note R said there is mould in the bedroom but no mould in the
carpet .
Case No: 352913 Determination Page 11 of 16
8 June 2011 Moisture reading in floor is 10% (5 - 10% is normal) .
R believes condensation in house due to no ve ntilation and
house sitting low.
Arranged IC and C to at tend .
Told Applicant s to mitigate loss by repairing pipe, removing
suitcase and cleaning mould .
FSP’s building
consultant’s (IC’s)
report
17 June 2011
IC is a building consultant who inspected 10 June 2011 .
He inspected all internal rooms, the perimeter of the house
and a small section of the subfloor on the eastern side .
He was told the new timber floor was put in about 5/6 years
earlier and attached to original boards .
IC notes the Applicants said they first started to notice a rear
section of floor s tarted to cup about 2 - 3 years ago. IC said this
indicative of differing moisture content between the underside
of the board and the upper surface. The moisture from the
subfloor is absorbed into the original timber floor because of
insufficient cross flow ventilation and dead air spaces and the
upper floor dries because of airflow from open doors and
windows in the house .
T he Applicants said first noticed mould problem within house
around 2 - 3 years ago and considers there is mould on the
underside of floori ng.
P lumber replaced storm water line on eastern side after
testing in March 2011 and his report was reviewed .
M oisture content readings of the boards were taken and
highest readings were noted outside bedroom 1 where mould
was note on contents items - des cribes the readings as high
humidity levels .
IC noted “virtually no sub floor ventilation” on north, west and
south sides of house .
O n south side and east side of house, brick course laid to stop
rainwater runoff .
S outhwest corner bricked in stopping venti lation .
I nspected under the floor on the east side up to where the new
pipe laid - the subfloor soil is set below the outside path and
water would tend to pool here – saw moisture but not
saturation .
S aw daylight coming through opening on the north side bu t
some shrubs there too .
A ll soil he could see was moist not just near pipe .
M oisture staining to brick piers .
I ntersection walls tend to restrict airflow and dead airspace in
50% of sub floor .
T here are issues with site drainage and sub floor ventilation
T he storm water line on eastern side may have been
problematic at time of inspection by plumber in early March
2011 and had been recently replaced .
A s the Applicant s said the soil is constantly wet, this constant
dampness not indicative of just a problem when it rains with
the leaking pipe but there is run off seepage too which
contributes to the moist atmosphere in the subfloor .
Case No: 352913 Determination Page 12 of 16
L ack of ventilation has not allowed for the reasonable drying of
sub - floor soil – this is irrespective of cause of leaks and thi s
damp environment has transferred into hardwood flooring
substrate and into „new‟ boards .
T imber floors should not be laid over moist subfloor spaces .
P hotos provided in support .
FSP file note
22 June 2011
Applicant s advised he has blocked western pipe and it is now
like a lake under the house .
FSP file note
15 July 2011
Applicant s advised the house is now dry as no recent rain –
the west pipe is causing the damage .
Applicant letter to
FSP
15 July 2011
Beginning 2 011 discovered sub floor damage .
Cupping in floor had been evident for 2 years .
April 2011 replaced eastern line .
May 2011 subfloor dry until period of rain .
June 2011 fans replaced in bathroom yet moisture readings
the same.
1 July 2011 IC attends and the Applicant s and he plug up the
high storm water line and it empties quickly. Under the house
water oozing out onto subfloor soil.
Cupping occurs at about the same time as front path was jack
hammered up and re - laid near the west line .
14 July 2011 subsoil dry as no rain so ventilation working .
He has gone under house as has the plumber and IC .
Remains concerned to repair west line because of claim
ramifications.
FSP’s building
consultant’s (IC’s)
email
18 July 2011
He was at testing with the Applicant s and says there is a
problem wi th the western storm water line.
Water escaped at some unknown point .
The water percolated through and first appeared toward to
eastern side of the subfloor (midway) and formed shallow
pools on this low side .
He did not see w ater on the west side .
The water would run like this in heavy rain .
He thinks the problem with the western line was there for
some time and the eastern line masked it .
The water leaking from either pipe has not come into direct
contact with the new timber flooring the original floor below it
or the bearers or joists .
The only way the moisture can get there is by hygroscopic
action – that is the timber absorbs air borne moisture from a
sub floor with very high humidity .
The high humidity in combination with the restricted
evaporation effect of the new flooring being laid over the
original has created an environment where the cupping can
occur – differential moisture contents between the top and
bottom surfaces – the top surface remains dry .
The moisture is tr apped between the old and new floor and
keeps this area damp.
The area retains an above recommended moisture content
which is greater than the top surface and so it cups.
Case No: 352913 Determination Page 13 of 16
The cupping would not have occurred if the new floor had not
been overlaid or if ther e was better ventilation or lower
humidity in the subfloor environment .
FSP file note
18 July 2011
Decision made to cash settle the claim because there is
damage resulting from an insured event but the ventilation
issues may mean the cupping would occur again and can‟t
warrant repairs .
R to re - inspect re contents damage .
FSP file note
25 July 2011
Assessed damage to contents as listed and floor.
Recommended offer of $21,000 plus 3 weeks accommodation .
FSP file note
29 July 2011
Offer discussed - sco pe of works, time to repair and whether
house livable or not while under repair .
Told holes in floor preexisting and FSP not liable .
Written offer made - re contents, Applicant s to supply quotes
to replace items listed .
FSP file note
11 August 2011
Called to discuss .
Insured on holidays and will review when return on 21 August .
FSP file note and
email from C
30 August 2011
FSP called C as had no report.
C advised he had attended in June and did not identify any
visible mould or smell of mould .
C concluded mould was non toxic and will dry when sub floor
dries .
Problems claimed in master bedroom (on western side) and C
noted concrete floor had been built up on the western edge so
ground level higher than floor level of house .
This will impact on moi sture levels and rising damp within the
house .
No sub floor ventilation would contribute to mould growth .
C says his inspection preliminary and he would need to take
samples to rule out pathogenic mould and bacteria .
FSP’s building
consultant’s (IC’s)
rep ort
16 September 2011
14 September 2011 re inspection of dampness in TV
cupboard in bedroom 1 and mould growth on west side of
house.
IC noted dampness and increase in mould growth e specially
on west side of house.
Harwood flooring laid on top of pine floo ring and Applicants
were concerned mould in the layer between .
Storm water line on west of house had breaks and was
recently r eplaced with PVC.
IC agrees there is a damp environment in sub floor and this is
causing mould .
Prior to the new PVC water may have been infiltrating the soil
during heavy rainfall but the inadequate ventilation combined
to maintain the moist environment .
50% of the subfloor ventilation is inadequate to the west .
N eeds to be a significant increase in ventilation and air
movement u nder western area to allow soil and timbers to dry
and this would help create environment less susceptible to
fungal growth .
T he problem with the floor is unknown until the floor is
Case No: 352913 Determination Page 14 of 16
removed at least in part .
H e agrees there is mould and it is associated wi th moisture in
the sub floor and this is compounded by lack of subfloor
ventilation .
FSP file note
19 September 2011
Discussion with IC .
IC says mould growth because there is no ventilation .
Applicant told IC repairs are $50,000 to $150,000 and or that
house might have to be knocked down .
BOM Extracts Shows 44 days of rain in May – August 2011 .
Applicants’
plumber’s (SB’s)
report
7 March 2011
SB inspected under the house 4 March 2011 .
The male Applicant told him that under the house it is
constantly wet with large pools of water and sloppy mud .
SB says the water service is sound .
He went under the house from the eastern driveway which
was tight as there is only 350mm crawl space .
At 2 meters in found an old earthenware storm water pipe laid
on the gr ound .
It collects the roof water for more than half the house .
Visual evidence that the sand cement joints in earthenware
storm water pipe no longer water tight .
When under the house he noted the sub - floor was dry and
firm. Rings of moist ground evident about half a meter
diameter radiating from all the cement joints of the pipe .
The subfloor fell away from the pipe and the subfloor on the
other side of the pipe was moist but appeared fairly firm and
he couldn‟t see puddles or mud .
The only way to the oth er side of the house was to squeeze
over the pipe – the crawl space is tight and the pipe subject to
movement when crossing it .
Kitchen and bathroom sewer services – no visible evidence of
leaking joints – domestic water services sound .
The storm water pip e on the west side had limited visual
inspection points. He ran a hose in the gutter for about 15
minutes and water ran to the kerb and no water seen pooling
on subfloor on west side .
On the east side the hose in the gutter lead to a large pool of
water ga thering in a short time and when hose turned off the
water entered the kerb .
This pipe fails after rain .
The joints and pipe have appeared to have failed as a result of
movement because of limited access to the other side of the
house - by persons inspecti ng or installing a service under the
house .
Following this report the Applicants replaced the storm water
line on the eastern side of the property .
Quote
24 August 2011
To lift and replace carpet $2,850 .
Applicants’ mould
assessor’s (M’s)
report and mould
P roperty assessed 19 September 2011 to de termine extent of
fungal damage.
I dentified mould and bacterial growth on contents in bedroom
Case No: 352913 Determination Page 15 of 16
laboratory
analytical reports
Both dated 26
September 2011
and on co ntents and lounge suite in living room .
T he particle board under the loun ge room was not fit for
purpose.
B edrooms on the other side of the house had no mould
indicative of high ventilation under that side of the house .
L evels of mould in pier under house, particle board, lounge
suite, wall hangings and carpet in main bedroom high to very
high and constitute a health risk .
P remises requires mould remediation and he described scope
of works .
Applicants’ mould
assessor’s (M’s)
report
25 October 2011
T he ( w estern) d amaged storm water pipe would be expected
to create greater vapor levels in the main bedroom side of the
house as the drying there would be less due to lower levels of
ventilation .
The (eastern) storm water pipe more open and flooding from
that pi pe would dry quicker with less water vapor intrusion into
the house .
Because of financial considerations testing limited to areas of
main concern of odor and the main bedroom .
Further sampling and remediation may cost around $20,000 .
Applicants’
plumber’s (SB’s)
report
18 February 2014
C larification of 2011 report .
T he 100mm storm water pipe with cement mortar joints on the
east side of the house was “severely” damaged at a majority
of joints .
T he clearance of 350mm was from the top of the pipe to the
underside of the floor .
Applicants’
engineer’s (DE’s)
report
4 March 2014
DE inspected the property as Applicants say mould has
continued to increase .
DE agrees that there had been a serious drainage issue
resulting from the damaged sto rm water lines which have
been subsequently replaced with PVC pipes.
Applicants were concerned about drainage after purchase in
2005 and undertook improvements including a concrete path,
replacing earthenware pipes with PVC pipes and installing
grated tren ch drains along the west path .
From observation DE says the Applicants have controlled
storm water generated from their property by directing it away
from the house towards the street .
DE took photographs of the subsoil under the dwelling and
says it show s severe cracking of soils indicating sub - soils are
highly reactive to moisture variations. They shrink and swell
depending on moisture.
The photo graphs support this observation.
DE was therefore concerned about long term structural
stability of building w orks constructed on these soils .
Applicants’ mould
assessor’s (M’s)
report
10 July 2014
C ommented on 2011 report .
C ommented on Wayne Tank principle and said there were not
concurrent events as there was no microbial issues before
2009 and the fungi found was that normally found in water
damaged building.
Case No: 352913 Determination Page 16 of 16
I nspection in 2011 was carried out in dry weather and the lack
of ventilation although less than optimum would not cause the
phys ical moisture issues documented.
T he cupping was only noted in 2009/10 not occurred in the
previous 4 years .
T he western pipe was repaired in August 2011 .
W hen he inspected under the house in 2011 it was dry but
there was evidence of where water had been running
previously .
D amage is due to water ingress under house as can be seen
from mould and swelling on a photograph of a piece of
furniture - the water mark on the back of the furniture in dicates
there must be a huge amount of water under the house .
T he fungi found is “water loving” and react to high water
activity .
T his fungi found in skirting boards, carpets in bedroom and on
pier under house and does not occur without high water
activity .
DVD of western
storm water line
Shows inspection of storm water on right hand side of house
pathway .
Photographs H ouse when purchased in 2005 – north face bricked in and
now opened up .
M ould damage to various contents .
V entilation on the northern side and a vent in the laundry and
the rear southern vent is described as showing an
unobstructed path through the northern openings .
2013 Edition of
Health and Amenity
Minimum height is 400mm .
Timber frame house the space can be 200mm .
Even good ventilation is of little value if ground wet because of
poor drainage or seepage .
Letter JB
17 February 2014
About 8 years ago, he saw newspaper under the floor
covering which was not damaged by water .
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.