Home / Financial Firm (Unknown - Insurer) / Determination 351663
Determination 351663
Denial of timber floor damage claim after burst pipe
Summary
Owners claimed $47,124 for replacement of timber flooring after a burst pipe flooded their kitchen. AFCA preferred the insurer's contractor evidence that the floor damage was not caused by the escaped water, so the insurer was entitled to deny the claim.
The claimant must show the loss falls within cover, and on the balance of the expert reports the floor condition was not established as caused by the escaped water.
Issues
- Claim denial primary · not upheld“The condition of the floor boards was not due to the escape of water from the burst pipe as the expert evidence does not support such a finding.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of
claim-Exclusion/ condition
Determination
Case No: 351663 Determination Page 1 of 5
Case number : 351663 20 November 2014
1 Overview
1.1 Dispute
On 28 November 2013 a pipe to the sink in the Applicants ’ powder room burst
causing water to escape from the bathroom to the kitchen. The Applicants lodged
a claim under their home building insurance policy held with the Financial
Services Provider (FSP) for replacement of the timber flooring in the sum of
$47,124.
The FSP denied the claim on the ground no resultant damage occurred to the
flooring following the burst pipe incident.
This dispute has not been the subject of a Financial Ombudsman Service (FOS)
Recommendation. Due to its nature, it was appropriate to proceed directly to a
Determination in line with the Operational Guidelines to the FOS Terms of
Reference.
1.2 Issues and key findings
Was the condition of the floor boards due to water from the broken pipe?
The condition of the floor boards was not due to the escape of water from the
burst pipe because the expert evidence does not support such a finding.
1.3 Determination
This Determination is in favour of the FSP.
The FSP was entitled to deny liability for the damage claimed to the floor boards.
Case No: 351663 Determination Page 2 of 5
2 Reasons for Determination
I have decided this case on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous FOS decisions. There has been
a full exchange of all documents relied on to make this determination and each
party has had the opportunity to address any issues raised by the other.
I have taken into account all the material submitted by the parties.
2.1 Was the condition of the floor boards due to water from the
broken pipe?
The condition of the floor boards was not due to the escape of water from
the burst pipe as the expert evidence does not support such a finding
When making a claim under an insurance policy, the responsibility rests with the
policyholder to establish, on the balance of probabilities, that the cause of the loss
claimed falls within the cover provided by the contract. Once established, the
burden than falls on the FSP denying a claim to show, on the balance of
probabilities, that the claim does not succeed.
It is not in dis pute that a pipe to the vanity in the Applicants’ powder room burst
and a substantial volume of water flowed from the bathroom to the kitchen.
Three assessment reports have been obtained which:
describe the damage
report on the probable cause for the damage, and
the reasons for arriving at their decision.
The two contractors commissioned by the FSP, HR and CF, report the damage
claimed was not caused by the escaped water. Conversely, the contractor, CC,
appointed by the Applicants considered the damage was due to the escaped
water. As such the success of the claim depends on which report is relied on.
The expert evidence provided by the parties is only opinion. I must take it into
consideration but I am not bound by it in reaching my decision. However, after
careful analysis of the three reports, I am persuaded the reports provided by the
contractors commissioned by the FSP may be relied on.
The reports from HR and CF are comprehensive and address a number of factors
which assist in determining the probable cause for the condition of the flooring.
These include:
no damage observed to the vanity in which the pipe burst
moisture tests revealed normal levels of moisture
lack of moisture between the joins
gaps were present in the flooring which had not been inundated by the
escaping water
kick panels in the kitchen were not swelling.
Further, CF observed boards in some areas squeaked, noting damp floor boards
do not squeak – only dry boards do.
Case No: 351663 Determination Page 3 of 5
On the other hand, CC observed cupping had occurred in various areas
throughout the property but only occurred where the escaped water had reached.
He also observed significant shrinkage of the floor boards and gaps between
them. CC explained, shrinkage occurs as the edges move away from the centre
of the floor board. Contrary to CF, CC said he observed water damage to the
vanity unit doors in the form of swelli ng and rust on the hinges.
In response to CC’ s report, HR noted the damage to the vanity doors was to the
top of the doors. He explained, in this case he would expect the bottom shelf to
also be water damaged if the top of the vanity unit doors were water damaged by
the burst pipe. However, the bottom shelves remain unaffected by water.
HR further noted cracking between the floor boards was not consistent with the
effects of water, which causes swelling, not shrinkage.
While there are some differences in the evidence in relation to the effect of water
on the timber flooring, I am of the view that timber is more susceptible to swelling
when wet than contracting. Further, the presence of gaps between the joins in
locations other than where water covered the flooring, such as the living room, is
compelling.
For these reasons I consider the evidence does not establish the cause of the
damage claimed falls within the cover provided by the policy.
Case No: 351663 Determination Page 4 of 5
3 Supporting information
3.1 Expert evidence
Record Key points
FSP’s expert HR
Report
28 November 2014
Timber strip flooring in the kitchen was cupped slightly.
No damage to the vanity unit or skirting boards in the
hallway/kitchen were found.
No indication of cupping of the floor boards in any other
areas that water would have passed over to reach the
kitchen.
Moisture tests showed normal levels. He would have
expected much higher levels in the flooring if moisture
caused the damage.
He would have expected to see the clear finish bec o me
milky when exposed to water. T here was no indication of
this.
FSP expert CF
Report
12 December 2013
The vanity unit was not water damaged and the MDF door
frames and skirting boards had not swelled.
Floorboards were squeaking with large gaps at the joins in
the hallway. There was no apparent moisture between the
joins.
If wet , boards will swell not shrink.
There were no water stains on t he flooring.
The flo o r in the living room where there was no water
damage also had large gaps between the boards.
Flooring in the kitchen are a and kick panels were not
swelling
Floorboards in the hallway were lifting when stood on and
no moisture appeared but they squeaked.
Damp floor boards do not squeak only dry boards.
FSP expert CF
Report
20 August 2014
The top of the vanity unit d o ors do not support the claim
the unit was water damaged as the bottom shelf remains
undamaged. If the top of the unit door was damaged by the
escaped water it could be expected that the bottom shelf
would also be damaged. The bottom shelf remains
undamaged.
Cra cking between the floorboards is not consistent with the
effects of water damage which causes swelling not
shrinkage.
He has not seen e stablis h ed dried kiln solid timber floor
swell so badly that it cupps and then shrinks back so badly
that large gaps occ ur.
Applicant’s expert CC
Report
1 August 2014
1 - 2mm cupping of the timber floor boards in various areas
throughout the p roperty was damaged . It appeared to be
consistent with only occurring where water/flooding had
reached.
Case No: 351663 Determination Page 5 of 5
Record Key points
In the worst areas cupping was observed and significant
shrinkage of timber floorboards.
Shrinkage occurs as the edges move away from the centre
of the floorboard. When one floorboard adjoins the next a
gap is created.
Water damage to both vanity unit doors (swelling) and four
door hinges (rust and corrosion) had occurred.
Based on a significant number of similar events he has
seen, he believes the claim falls within the Applicants’
policy.
3.2 Relevant policy terms
“ Summary of insured events
...
Escape of liquid
But we do not cover wear and tear, or loss or damage caused by the escape of
liquid occurring as a result of a gradual process of bursting, leaking, splashing,
dripping or overflowing over a period of time when you could reasonably be
expected to be aware of this condition.
We do not cover loss or damage caused by flood under this insured event. ”
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.