Home / Financial Firm (Unknown - Insurer) / Determination 351551

Determination 351551

Denial of pool enclosure structural damage claim

FirmFinancial Firm (Unknown - Insurer)
Decided2014-09-04
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The FSP denied the applicant's claim for pool enclosure damage from leaking stormwater pipes under exclusion provisions. AFCA found the leaking pipes were an insured event and ordered the FSP to settle 70% of repair costs once a current quote is obtained.

Once the insured shows an insured event caused the loss, the insurer must prove an excluded event was a dominant or proximate cause, and it did not, so the loss is apportioned 70:30.

Issues

Subjects and remedies

home or building damagepay claim

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim Determination Case No: 351551 Determination Page 1 of 9 Case number: 351551 3 September 2014 1 Overview 1.1 Dispute This dispute arises as a result of the denial by the Financial Services Provider (FSP) of the Applicant’s claim for damage to the structure of a pool enclosure. The FSP has denied the claim on the basis the damage was not caused by a listed insured event but was caused by excluded events. 1.2 Issue and key findings Is the FSP entitled to deny the Applicant’s claim? The FSP is not entitled to deny the Applicant’s claim because:  the Applicant has established that the cause of the damage was a leaking pipe which is an insured event  the FSP has not established that a dominant cause of the damage was inherent defects in the construction of the pool enclosure. However, issues with the construction of the pool enclosure have most likely exacerbated the damage. It is fair in all the circumstances to apportion the loss such that the FSP is responsible for 70% of the damage. 1.3 Determination This Determination is in favour of the Applicant. The FSP must obtain a current quote for the cost of repairs within 30 days of the Applicant’s acceptanc e of this Determination. Within 30 days of receiving the quote for the cost of repairs, the FSP must:  provide a copy of the quote to the Applicant, and  settle 70% of the cost of the repairs with the Applicant. Case No: 351551 Determination Page 2 of 9 2 Reasons for Determination I have decided this dispute on its merits, doing what is fair in the all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties. I am satisfied that the documentation I have relied on has been provided to both parties. 2.1 Was the FSP entitled to deny the claim? The policy provides cover for water damage except in the event of structural defects The FSP’s policy is a defined events policy. This means the policy only responds where the damage has been caused by one of more of the listed events, which are then subject to exclusions. The policy covers loss or damage caused by, among other things:  earthquake  storm, rainwater or run-off (unless this is caused by soil movement including subsidence, shrinkage of earth or land or hydrostatic pressure) and  water or other liquid damage resulting directly from the leaking of fixed pipes. The policy excludes loss or damage caused directly or indirectly through inherent defects, faulty design, structural defects or poor workmanship. Burden of proof shifts in respect of the Applicant’s claim The onus rests with the Applicant to prove, on the balance of probabilities, he sustained a loss caused by an event insured for under the policy in force, at the date of loss. Once the Applicant satisfies this onus, the burden shifts to the FSP to establish the claim falls within an exclusion from cover. Insurer may deny claim where there are multiple concurrent causes but one cause is excluded under the policy Where there are multiple concurrent causes to the Applicant’s loss, the FSP need only establish that one of the causes is excluded by the policy in order to defeat the claim (Wayne Tank principle). The FSP engaged a series of experts After the Applicant engaged an engineer in support of his claim (L), the FSP engaged a series of experts as follows:  Engineer (M) who concluded damage was caused by inadequate drainage.  Leak Specialist (AL) who detected multiple cracks and leaks in the stormwater drain surrounding the pool.  Engineer M again, who after considering AL’s report concluded the damage was caused by inadequate drainage and leaking pipes.  Engineer (H), who provided a variety of reasons for the damage, including inherent defects. Case No: 351551 Determination Page 3 of 9 The damage to the pool enclosure was caused by leaking fixed pipes Having considered all the evidence, on the balance of probabilities, the damage to the pool enclosure was caused directly from leaking pipes. In support of this position is the following:  L that found the substantial cracking and ground movement was a result of changes in moisture content of the soil below the concrete slab and swimming pool caused by cracked and leaking stormwater pipes.  AL detected multiple breaks and blockages to the PVC stormwater line at the rear of the area. The breaks were significant and occurred across both sides of the pool enclosure.  M stated the subsidence of the structure and concrete slab was due to the long term water penetration and subsequent weakening of the underlying subsoils due to leaking pipes (70%) and inadequate drainage (30%). The Applicant has been unable to establish that an earthquake caused the cracked pipes An earthquake is an insured event and as such the onus is on the Applicant to establish it caused the damage to the pipes and the pool enclosure. The Applicant suggested the cracking in the pipes was due to an earthquake in mid 2012. The Applicant made a claim with the FSP for a cracked pipe at the front of his house, which followed the earthquake. That claim was accepted by the FSP, although the claim details do not establish it was accepted on the basis of earthquake damage. M stated that no significant earthquake activity had occurred during the relevant period to cause the damage to the broken pipe. M also noted that information regarding movement, cracking or damage to the home was not provided by the Applicant or found during the inspection. M stated there was no link between the front pipe leak and the damage to the pool enclosure at the rear of the property. M did note that it was unusual for the pipes to be broken in four locations under the concrete surrounding the pool. M stated that it cannot be categorically determined how the pipes became cracked or broken. The onus is on the Applicant to establish that the earthquake caused the damage to the pool enclosure. On balance, the Applicant has not satisfied this onus. However, the Applicant has established that the leaking pipes caused the damage to the p ool enclosure. The Applicant’s claim is therefore satisfied unless the FSP can demonstrate the damage was caused by an excluded event. The FSP has not established an excluded event caused the damage The FSP’s engineers have not established that there were other concurrent causes to the damage to the pool enclosure, in particular that the damage was due to structural defects. This is because: Case No: 351551 Determination Page 4 of 9  While M stated the three rear posts, rear wall and concrete slab subsided due to, in part, inadequate drainage, the Applicant stated M did not perform any water tests on site. A video supplied by the Applicant during heavy rain showed there was no drainage issue.  AL stated water in the soil was likely to be from breaks in the stormwater lines.  M stated that pipe leakage would be localised, causing the reactive clays to swell, but not long term subsidence of the pad footings and concrete slab. However, M also states that the rear posts, rear wall and concrete slab have subsided due to the penetration of water into the underlying soils. The pad footings supporting the rear of the structure are subsiding into the weakened sub soils. M and H hypothesised that the damage may have been caused by:  the surrounding soils, which may have been weakened by the excavation of the pool and lack of ground compaction  the leaking pipes, which may have broken during compaction and which were inadequately installed  the footings, which were inadequate  the concrete, which was not reinforced, and  a lack of flexible joints in the paving and tiles installed over breaks in the pour. Expert M attributed 70% of the damage to leaking pipes and 30% to inadequate drainage. Expert H identified three types of damage:  Wall movement caused by inadequate construction and seasonal moisture changes.  Cracks on the timber fascia which was due to inadequate construction of the roof framing and / or from movement in the walls.  Damage to paving tiles, mortar bedding and concrete sub base, due to all of the reasons listed above. When asked by the FSP what percentage of damage to the paving tiles, mortar bedding and concrete sub-base could be attributable to leaking from the pipes, H responded that: “an equal percentage to each of the issues as in our opinion we can’t isolate one cause from another.” When asked by the FSP whether the cracking would have occurred if there was no leaking pipe, H responded that: “it is possible that cracking and movement of the paving would have occ urred.” Having considered all the evidence, I am not satisfied that the FSP has established that the problems identified by the two experts, M and H (other than the leaking pipes), are a proximate cause of the damage to the pool enclosure. As referred to above, M stated it cannot be determined how the pipes became cracked or broken. Even for the “wall movement” (which H states is not related to the escape of water from the cracked and broken storm water drains) H notes that wall movement is a result of not only inadequate construction but also seasonal moisture changes. Case No: 351551 Determination Page 5 of 9 The leaking pipes would have exacerbated “seasonal moisture changes” and hence caused the walls to move and crack. In reaching this conclusion I have also considered the material provided by the Applicant to demonstrate the pool enclosure was adequately constructed. The Applicant submitted the building permit, the blueprints and the certificate of final inspection for the swimming pool enclosure. He also provided a letter from the engineers prior to construction of the pool enclosure stating that the proposed structure would meet all structural and serviceability requirements and is adequate in all respects to support the design loading. Expert H noted that the footings were not included in the drawings. The documentation, while supporting a conclusion that the pool enclosure was constructed with proper advice, does not establish that there were no defects in the construction of the enclosure, the compaction of the soil or the installation of the drainage. As the certificate states, it is not evidence that the pool enclosure complied with building regulations. FSP’s submissions were flawed The FSP made some incorrect comments in its submissions. These errors may have led to the FSP’s decision t o deny the claim. The FSP stated that:  Neither experts M or H referred to the leaking pipe as a cause of the damage, whereas both experts did refer to it.  Neither expert considered the leaking pipe was a predominant cause of the loss, even though M apportioned 70% to the leaking pipes.  There was limited material in support of damage being caused by leaking pipes other than footage of broken pipes and says the pipes were not identified and therefore cannot be confirmed, when expert AL drew a sketch of the pipes around the property identifying where they were broken and provided video evidence.  There was no evidence to support how the pipes and blockages occurred, despite previously accepting the Applicant’s claim for a burst pipe without having to establish why the pipe burst.  Both experts indicated the damage to the property would have occurred if there were any leaks or not, when it is not apparent that M was asked this question and, in any event, did not answer it, and H responded it was “possible”. Further, the FSP:  inserted a requirement for the Insured Event to be “sudden and immediate” and “sudden and unforeseen” which is not supported by the policy, and  stated the Applicant had to establish that the damage had been caused solely by an Insured Event, as opposed to it being a dominant or proximate cause. Case No: 351551 Determination Page 6 of 9 While the policy covers leaking pipes, it excludes loss or damage caused as a result of the gradual escape of liquid over a period of time, where it is reasonable to have been aware of the gradual escape of the liquid. As the pipes were underground, it would not have been reasonable for the Applicant to have been aware of the leaking pipes until the damage was visible and investigations complete. As such, this exclusion cannot apply. Apportionment of loss is fair in all the circumstances While I have concluded that the leaking pipe is the cause of the loss, the damage to the pool enclosure was most likely greater than it otherwise would have been had there been adequate footings and correct installation of the pipes. As noted by the FSP, inherent defects are not covered by the policy. It is therefore fair in all the circumstances to apportion the loss. In this respect, I have followed expert M’s assessment that 70% for the damage resulted from the leaking pipe. As such, the FSP is responsible for 70% of the damage, and the Applicant 30%. 3 Supporting information 3.1 FOS approach for this dispute This dispute has not been the subject of a FOS Recommendation. Due to its nature, FOS has considered it appropriate to proceed directly to Determination in line with the Operational Guidelines to the FOS Terms of Reference. There has been a full exchange of the relevant material between the parties and each party has had the opportunity to address the issues raised. 3.2 Key points from relevant supporting materials Record Key points Engineer (JK) Letter 19 Apr 2001  The proposed structure will meet all structural and serviceability requirements and is adequate in all respects to support the design loading. Applicant’s Engineer (L) Report 20 Nov 2013  The pool enclosure has experienced substantial cracking and ground movement as a result of changes in moisture content o f the soil below the concrete slab and swimming pool. This is caused by cracked and leaking stormwater pipes. FSP’s Engineer (M) Report 28 Nov 2013  Pre - existing issues  The concrete pavement to the outside falls towards the rear wall where a small shower waste is utilised as a drain. The shower waste is inadequate to drain rainwater and can easily block. Any ponding of water will penetrate into the ground and under the brickwork.  Proximate cause and effect  The three rear posts, rear wall and concrete slab have subsided due Case No: 351551 Determination Page 7 of 9 to inadequate drainage and penetration of water into the underlying soils.  The rear of the structure is supported by three posts that are typically embedded into pad footings that are subs iding into the weakened subsoils.  Contributing factors may be: o The surrounding soils may have been weakened by the excavation of the pool during its construction. o There is a possibility the pad footings were not adequately founded into natural clay and constructed in fill. FSP’s Leak Specialists (AL) Report 19 Dec 2013  The PVC stormwater line to the rear “stratco” area has multiple breaks and a blockage.  The PVC line partially exposed beside the pool has multiple cracks and breaks. The line is blocked externally beneath the sliding door.  The stormwater line where two down pipes enter from rooves above have two major breaks allowing water to leak from the lines to the ground below.  The slotted PVC drain directly beside the pool has a large amount of wat er sitting in line, indicating the pool has a large amount of water surrounding it. This is likely to be from breaks to the stormwater lines.  Beside the pipe where the crack in the pipe is evidence is solid concrete. FSP’s Engineer (M) Report 19 Dec 201 3  No significant earthquake activity has occurred during the relevant period to cause the damage to the broken pipe.  Pipe leakage would be localised and cause swell of the reactive clays but not the long - term subsidence of the pad footings and concrete slab.  Pipe leakage is localised and affects the immediate area rather than all three pad footings across the rear of the structure similarly.  The removal of the plants and root system of the garden bed would cause further wetting of the soils due to the r educed moisture absorption by the plants.  There is a large gap between two paving slabs. Water would enter the gap and penetrate the subsoils.  The movement for the leaking pipe at the front of the property is different to the subsidence experienced to the rear structure. The leak to that pipe has not affected the rear structure. Pre - existing issues  Ground and drainage layout and construction is not in accordance with the relevant Australian Standards Proximate cause and effect  The subsidence of the structur e is due to long - term water penetration and subsequent weakening of the underlying subsoils due to inadequate surface protection and inadequate drainage as required by Australian standards.  The crack in the pipe has not caused the consistent subsidence acr oss the rear of the structure. Case No: 351551 Determination Page 8 of 9 FSP’s Engineer (M) Report 24 Dec 2013  The Applicant considers damage to the pipes was caused by an earthquake. Information regarding movement, cracking or damage to the home was mot provided by the Applicant or found during the inspection.  The nominated pipe breaks are noted to be within the enclosed area and under the concrete pavement.  It is unusual that the pipes are broken in four locations under the concrete surrounding the pool.  It cannot be categorically determined ho w the pipes became cracked or broken, but possible causes of are ground movement and settlement due to lack of ground compaction around the pool, pipe breakage during ground compaction, inadequate pipe installation.  The subsidence of the structure and conc rete slab is due to long - term water penetration and subsequent weakening of the underlying subsoils due to the leaking pipes, inadequate drainage and inadequate surface protection.  Apportionment for inadequate drainage / surface protection: leaking pipes of 30%: 70% may be fair and reasonable in the circumstances. FSP’s Engineer (H) Report 28 Jan 2014  The design certification and drawings of the rook and the supporting posts including the pad footings for the pool enclosure received form the local Council were reviewed. There are no footings details for the walls of the enclosure in the drawings.  The concrete appears to be unreinforced and the cracks are generally occurring along breaks in the concrete pour.  The cracked and broken stormwater drains may have resulted from inadequate cover between the top of the drains to the underside of the paving.  The inspection of the standpipe showed that there was no high level of water in the pipe as reported by expert A L.  The concrete footing for the brick below the door is well below the depth required.  The walls of the enclosure have been constructed on a shallow footing and not on a structural footing.  The stormwater drains within the concrete sub - base are not lagge d as required to reduce the stress placed on the drains. “Therefore, in our opinion, the cracking and movement evident on the paving tiles, mortar bedding and concrete substrate are a result of a combination of: settlement of the soil below the concrete wh ich could be distributed soil with the excavation of the swimming pool and was not adequately compacted, inadequate construction of the concrete substrate, the paving tiles installed to bridge over the breaks in the pour of the concrete, inadequate install ation of the stormwater drains resulting in weakened areas of the conc rete, also from the report ed saturation of the soil around the swimming pool below the concrete sub - base due to the escape of water from the cracked and broken stormwat er drains, and fro m lack of flexible joints in the paving to allow for thermal expansion and cont raction of the paving tiles.”  Water escaping from the cacked and broken stormwater drains can saturate the solid below the concrete substrate and this can result in settlement o ccurring of the soil and the paving poured and lid over the soil.  The movement evident to the walls of the pool enclosure is typical Case No: 351551 Determination Page 9 of 9 of problems due to inadequate construction.  The walls are built over a shallow footing. If the footings are shallow, a gre ater amount of cracking and movement than normal can occur.  The wall movement is a result of inadequate construction and not related to the escape of water from the cracked and broken stormwater drains.  The cracked timber fascia is due to possible inadequa te construction of the roof framing in this area and/or from movement of the brick wall/pier at the northeast corner due to shallow footings below where the beam fixed to the timber fascia spans across to. FSP’s Engineer (H) 4 Feb 2014  FSP asked the engineer “what percentage or extent of damage to paving tiles, mortar bedding and concrete sub base do you believe can be attributed to water leaking form these pipes?  H responds: “We would apportion an equal percentage to each of the issues as in our opin ion we can’t isolate one cause of damage from another.”  FSP asks H: “One interpretation of this report is that the damage to the paving tiles, mortar bedding and concrete sub base would have occurred anyway due to points a, b, c as noted above, regardless of whether the storm drain broke or not. What are your thoughts on this or is it just not possible to comment on this?  H responds: “In our opinion, it is possible that cracking and movement of the paving would have occurred if there was no leaking pipe as there are other causes for cracking and movement to occur.”

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.