Home / Financial Firm (Unknown - Insurer) / Determination 349180

Determination 349180

Denial of storm damage claim to light pole under corrosion and gradual deterioration exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2014-07-22
ProductGeneral Insurance · Business / commercial
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

A sporting club claimed for a light pole that was damaged in a September 2012 storm and was denied as caused by long-term corrosion from installation directly into soil. AFCA found the corrosion and gradual deterioration exclusions applied under the Wayne Tank principle and that s46 of the Insurance Contracts Act gave no relief, so the FSP was entitled to deny the claim.

Where concurrent causes include one excluded cause, the whole loss is excluded under the Wayne Tank principle, and s46 does not apply to exclusions that operate irrespective of when the contract was entered into.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Small Business/Farm Insurance - Commercial Property - FSP Decision - Denial of Claim Determination Case No: 349180 Determination Page 1 of 4 Case number : 349180 14 July 2014 1 Overview 1.1 Dispute The Applicant is the club president of a sporting group which holds a business insurance policy with the Financial Services Provider (FSP). On 13 September 2013 the Applicant lodged a claim on behalf of the sporting group with the FSP for damage to a light pole which occurred during a storm on 6 September 2012. The FSP denied the claim on the basis the proximate cause for the damage was corrosion over a period of time due to faulty design and therefore excluded from cover. The Applicant considers section 46(2) of the Insurance Contracts Act (the Act) should provide relief because the corrosion to the base of the pole was underground and could not be seen. Furthermore, the Applicant notes there is an open water channel next to the subject pole and says rainwater runoff from this drain has more than likely contributed to the corrosion, particularly as the other light poles installed at the club did not fail. 1.2 Issues and key findings Was the FSP entitled to deny the Applicant’s claim ? The FSP was entitled to deny the Applicant‟s claim because:  the proximate cause of the loss was long term corrosion, which is excluded from cover  rainwater runoff and wind may hav e contributed to the loss but the „Wayne Tank‟ principle applies to exclude the entire loss from cover  section 46(2) of the Act does not provide the Applicant with relief because the exclusions relied on by the FSP operate irrespective of the time of entry into the contract. 1.3 Determination This Determination is in favour of the FSP. The FSP is entitled to deny the Applicant‟s claim. Case No: 349180 Determination Page 2 of 4 2 Reasons for Determination 2.1 Was the FSP entitled to deny the Applicant’s claim ? As the Applicant is seeking indemnity under the policy, the onus is on him to establish the damage was caused by an event covered by the policy. This is called a prima facie claim. Once the Applicant has established an insured event is responsible for the damage, the onus is then on the FSP to establish the damage claimed is excluded or not covered by the policy. The proximate cause of the loss was long term corrosion which is excluded from cover There is no dispute damaging winds occurred on 6 September 2012 which caused a light pole at the Applicant ‟s sporting club to lean. The policy provides cover for loss or damage caused by „wind‟. The Applicant has therefore established a prima facie claim under the policy. However, expert evidence provided by the FSP suggests the proximate cause of the damage to the light pole was not the strong winds but instead long term corrosion to the base of the pole as a result of being installed directly into soil without encasement in concrete. The FSP‟s expert, engineer (G) , has stated the steel light posts were insta lled at the club around 20 years ago. He notes the poles were installed directly into soil rather than being encased in concrete and as a result of the moisture conditions underground, the steel has started to corrode. G notes recent standards in relation to the installation of steel poles indicate the bases should be above ground but can be installed below ground if appropriately designed i.e. if the steel is encased. G has confirmed he is not familiar with the standards that would have been in place over 20 years ago but as the design principles are the same, he assumes the same conditions would have applied. G accepts rainwater runoff from a drain situated adjacent to the pole has more than likely contributed to the corrosion and weakening of the soil surrounding the pole, however, he does not consider a one off rainfall event would be a significant factor but instead a number of rainfall events over the life of the pole. G‟s opinion regarding the proximate cause of the damage is corrosion of the steel work as a result of being installed directly into soil without encasement in concrete. He says the corrosion weakened the steel making the light pole unable to resist winds greater than 50 km/h when it should have been able to withstand winds of at least 150 km/h. The Applicant has not provided any expert or other evidence to the contrary of G. The policy clearly excludes loss or damage arising from gradual deterioration and corrosion. Accordingly, the FSP has established, on the balance of probabilities, the damage claimed is due to circumstances excluded from cover. Case No: 349180 Determination Page 3 of 4 The ‘Wayne Tank’ principle applies to exclude the entire loss from cover It is settled law that where there is more than one concurrent cause of a loss and one cause is subject to cover and the other is not, the insurer is not liable for the loss (refer Wayne Tank and Pump Co v Employers Liability Assurance Corporation [1974] QB 57) (the “Wayne Tank principle”). Therefore, irrespective of whether the rainwater runoff from the open drain and /or the storm conditions on 6 September 2012 contributed to the loss, the entire loss is not covered under the policy because the causes “ gradual deterioration ” and “ corrosion ” are specifically excluded from cover. Section 46(2) of the Act does not provide the Applicant with relief The Applicant has sought to rely upon section 46 of the Act. Section 46 of the Act provides that if a claim is made in respect of a loss that occurred in whole or in part as a result of a defect or imperfection in a thing and the insured was not aware of the defect or a reasonable person in the circumstances could not be expected to have been aware of the defect or imperfection, the insurer may not rely on an exclusion clause that refers to the condition of the thing before the contract was entered into. For section 46 of the Act to have application, the FSP is required to rely on a provision in the contract that has the effect of limiting or excluding the insurer‟s liability under the contract by reference to the condition, at a time before the contract was entered into, of the thing ( Nelson v The Hollard Insurance Company Pty Ltd [2010] NSWSC199 ). In these circumstances, the exclusions relied upon by the FSP apply irrespective of when the contract was entered into. Accordingly, section 46 of the Act has no application and thus does not provide the Applicant with relief. 3 Supporting information 3.1 FOS approach to this dispute A full exchange of the relevant information has taken place between the respective parties and each party has had the opportunity of addressing any issues raised. 3.2 Key documents Record Key points FSP’s Assessor (C ) Report 19 Sep 2013  Wind damage to light pole 6 September 2012  Winds in excess 100km/h in Melbourne area  Inspection revealed corrosion – believe rusted base is primary reason for collapse  Base of pole is surrounded by earth therefore mois t conditions have caused deterioration of metal over time Case No: 349180 Determination Page 4 of 4 FSP’s Expert (G ) Report 14 Oct 2013  Poles installed 20 yrs ago or thereabouts  Localised weakening/softening of foundation material has adversely affected ability of foundation material to resist lateral movement  Lateral external influence = wind FSP’s Expert (G ) Report 08 Nov 2013  Foundation movement was considered primary cause but further exploratory investigation when excavation undertaken to expose base  Primary cause has now been determined a s excessive corrosion which has caused local weakening of affected steel work FSP’s Expert (G ) Email to FSP 02 Dec 2013  Current Standards say steel bases should be above ground but can be below ground if appropriately designed ( i.e. encasing the steel below ground)  Not familiar with Standards in place around 20 years ago but design principles still the same so can safely assume same conditions would have applied  One off rainfall event would not be a significant contributing factor bu t countless events over the life of the pole would be a contributing factor  Recommend inspection of all other light poles as soon as possible . Nature and extent of corrosion dependent on soil conditions/drainage. Life expectancy likely to be compromised if not adequately protected below ground  Corrosion has occurred over a prolonged period of time as a consequence primarily of the affected steel work being covered with soil and not encased  Excessive rainwater runoff would have contributed but if base of pol e was encased or not covered with soil it would not be a problem  Proximate cause: 1. Steel post base founded below ground without being encased to protect from corrosion 2. Steel work has corroded 3. Corrosion has weakened steel so it was unable to resist winds gre ater than 50 km/h (should be able to withstand 150 km/h) 4. Due to high winds the pole eventually/inevitably failed

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.