Home / Financial Firm (Unknown - Insurer) / Determination 348651

Determination 348651

Claim for gas explosion damage to garage denied as not caused by an insured event

FirmFinancial Firm (Unknown - Insurer)
Decided2014-06-05
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed that a gas explosion damaged his garage, and the FSP denied the claim as the damage was not caused by an insured event. AFCA found the applicant had not established the claimed cause and preferred the FSP's expert evidence, so it determined in the FSP's favour.

The insured bears the onus of proving on the balance of probabilities that the loss was caused by an event the policy covers, and the observed damage was inconsistent with the explosion account.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim Determination Case No: «reference_id» Determination Page 1 of 3 Case number: 348651 4 June 2014 1 Overview 1.1 Dispute The Applicant lodged a claim against his home building insurance policy held with the Financial Services Provider (FSP) for damage to his garage. The FSP denied liability for the damage on the basis that it was not caused by an insured event under the policy. For convenience, submissions by the Applicant’s representative will be taken to have been made by the Applicant. 1.2 Issue and key findings Has the Applicant established that the damage was caused by an insured event? The Applicant has not established that the damage to his garage was caused by a gas explosion as claimed:  the damage observed is inconsistent with the circumstances described by the Applicant  given the observed inconsistencies between the Applicant’s version of events and the claimed loss, the expert report provided by the FSP, is preferred to the report provided by the Applicant. 1.3 Determination This Determination is in favour of the FSP. The FSP is not liable for the claimed damage to the Applicant’s garage . Case No: 348651 Determination Page 2 of 3 2 Reasons for Determination 2.1 Has the Applicant established that the damage was caused by an insured event? Damage inconsistent with circumstances described by the Applicant According to the Applicant, the explosion which caused the damage to his garage occurred when he lit a gas heater about 10 minutes after he changed the gas bottle to the heater. The damage to the garage includes:  displacement of top course of blocks on the north wall  the lifting by about 80 mm of the upper metre of the central pier supporting the roof truss on south wall, with the top course of the pier east of the window being dislodged by about 50 mm  horizontal cracking of the east wall and buckling of the central track of the roller doors  minor cracking to one of the piers on the west wall  charring to some of the roof timbers and lifting of the nails fixing the roof sheeting. It is difficult to reconcile how a gas explosion could cause such damage to the structure of the garage, yet allow the Applicant to escape significant injuries, given it is likely he would have been at or close to the ignition point for the explosion. Further, the glass windows and fluorescent tubes were not affected by the explosion. The Applicant says the jars, bottles and other items were knocked from their shelves but he cannot provide photographic evidence of this. In addition, according to two statutory declarations provided by the Applicant’s neighbours, the explosion caused damage to m ore than one of the Applicant’s vehicles. The invoices for the repairs to these vehicles have been provided to the Service, yet they show that the repairs undertaken were relatively minor and there is no indication that the repairs were for damage caused b y the explosion. These inconsistencies have not been satisfactorily explained by the Applicant. Expert reports reach different conclusions about the cause of damage The FSP concedes that an explosion occurred at the Applicant’s premises on 16 September 2013, but does not accept that the claimed damage was caused by this explosion. The FSP has provided a report by engineer “C” , produced after an inspection of the property on 7 October 2013. C concluded that the observed damage was not the result of an explosion and opined that:  if the explosion had caused the walls to bow and the garage doors to become misaligned as claimed, it would cause more brittle items such as glass windows and fluorescent lights to shatter. This was not observed at the time of inspection. Case No: 348651 Determination Page 3 of 3  the uneven expansion and shrinkage of the foundation soils of the garage (which are reactive clay in the Applicant’s area ) had caused much of the observed damage. The close proximity of trees to the garage and poor site drainage have contributed to this differential movement  the damage and misalignment of the garage track was caused by impact. The Applicant has provided a report by engineer “B”, produced after an inspection of the property on 12 November 2013. B concluded that the damage incurred was caused by a significant internal pressure of the magnitude that could be expected from an explosion. B stated also that there is no evidence that the damage to the Applicant’s garage was due to soil movements as asserted by C, saying that:  damage associated with the presence of trees normally appears as diagonal cracking starting from the footings and increasing in width toward the top of the wall and no such cracking was observed  the footings on three of sides of the garage are constructed in such a way that they would have greater stiffness than normal footings and enabled the structure to resist increased soil movements from trees and there is no evidence of poor drainage at the site. In addition, B addressed some issues raised in the report b y C:  B understands that the southern side roller door was open at the time of the explosion and would have relieved the pressure from the explosion and explains why the windows and light fittings were not affected  The windows were also shielded from the full force of the explosion by the solid timber bench along the south garage wall  The cylindrical shape of the fluorescent lights gives good resistance to external pressure and this might explain why they remained undamaged. The explanations provided by B as to why the glass windows and lights did not break are not persuasive. If it were accepted that the open roller door on the southern side caused the explosion pressure to be relieved to the point that the windows and lights were not damaged, it is highly probably that the same relief in pressure would operate on the walls and piers of the garage and similarly spare them from damage. In light of this and the other inconsistencies outlined earlier, the evidence of C is considered to have more weight in this matter. Accordingly, the Applicant has not fulfilled the onus upon him to establish that the claimed damage was caused by an event to which the policy responds.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.