Home / Financial Firm (Unknown - Insurer) / Determination 348411

Determination 348411

Claim denial: storm damage to garage under faulty design or structural defect exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2015-09-09
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The insurer denied a storm damage claim for a garage as caused by faulty design or structural defect. AFCA found the insurer had not proved that exclusion and ordered the claim paid, plus container storage costs and 50% of the engineer's report cost.

The insurer bore the onus of proving the exclusion, and its evidence did not establish that the garage failed to meet building standards when built.

Issues

Subjects and remedies

home or building damagenatural disasterpay claimpay compensation

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim Case number : 348411 10 August 2015 1 Overview 1.1 Dispute The Applicant lodged a claim for storm damage to his garage. The Financial Services Provider (FSP) denied the Applicant’s claim on the grounds the garage caused by faulty design and structural defect. The Applicant disputes the FSP’s decision to deny his claim. He seeks to have his claim accepted and repairs to his property paid for by the FSP. The Applicant also seeks reimbursement of his costs associated with:  obtaining an engineer’s report  the cost of hiring a shipping container to store the contents of his garage while awaiting the FSP’s decision. 1.2 Issues and key findings Has the Applicant established a claim under the terms of the policy? The Applicant has established a claim under the terms of the policy as the policy is an accidental damage policy and there is no dispute that the Applicant’s property was damaged following a storm. Is the FSP entitled to refuse the claim? The FSP is not entitled to refuse the claim. The FSP has not established on the balance of probabilities, the application of the exclusion relating to faulty design or structural defect. 1.3 Determination This Determination is in favour of the Applicant. The FSP is liable to meet the Applicant’s claim, including any relevant repairs to bring the property up to current standards. Subject to the Applicant providing relevant invoices the FSP is to pay the Applicant’s costs of hiring a shipping container and 50% of the cost of the engineer’s report. Case No: 348411 Determination Page 2 of 7 2 Reasons for Determination 2.1 Has the Applicant established a claim under the terms of the policy? The Applicant has established a claim under the terms of the policy. The Applicant’s policy provides cover for accidental damage subject to relevant exclusions. There is no dispute that the Applicant’s property was damaged during a storm on 28 November 2012. The Applicant advised the Assessor he believed a lightning strike at the front of the house during the storm caused the damage. The Assessor found no visible marks where the lightning had struck, but acknowledged impact damage. He could not confirm it was a lightning strike as the main power was not affected. The Applicant subsequently provided an invoice from an electrician confirming the need to reinstate the electricity following the lightning strike. I also note that the FSP’s structural engineer KC indicated it was hard to determine whether the damage was caused by the lightning strike or storm, although he believed the Applicant’s statements add credibility to the Applicant’s claim. He confirmed that the wind forces would also have caused damage. Regardless of whether the damage was caused by the lightning strike or high winds, the damage would be assessed under the terms of the policy as accidental damage being damage that was sudden, unintended and unexpected. The onus is therefore on the FSP to establish the application of an exclusion if it is to refuse payment of the claim. 2.2 Can the FSP refuse payment of the claim? The FSP has not established the application of an exclusion The FSP maintains that the damage sustained to the Applicant’s garage was a result of the failure to secure the roof truss with bottom cord tiles. The FSP maintains that this is defective building work and seeks to rely upon the general exclusion that relates to:  a defect in an item, faulty workmanship, structural defects/faulty design A building consultant SG considered that the roof truss did not have bottom cord ties and that this was a failure to meet the appropriate Australian standards. In his initial report, SG referred to standards introduced in 1997 which related to timber roof trusses. SG recommended a structural engineer be appointed. The FSP appointed KC to undertake relevant structural engineering investigations. KC identified the garage roof system as being a light weight steel truss with steel sheet roofing. The trusses ran parallel with the garage door and he noted there was cross bracing located underneath the roof sheeting, supported Case No: 348411 Determination Page 3 of 7 by a hard wooded beam running across the brick piers. The beam was tied down to the brickwork via a galvanised steel strap. He noted that normally a strut or multiple struts would be provided at the bottom cord of the truss. SG provided a supplementary report on 21 August 2013. On this occasion, SG referred to the relevant standards for domestic metal framing. There is no reference in those standards requiring a light gauge steel truss to be secured by bottom cord ties. SG believed industry best practise at the time the garage was built in 1995/1996 would be to have bottom cord ties. On this basis, he did not believe the roof had been braced in accordance with domestic Australian standards. I note from the supplementary report he confirms that there were brick tie downs and dynabolts hanging from the truss that were removed as part of the clean up. Significantly, in an email to the FSP, SG concedes that the relevant Australian standards relating to the bracing do not specify what is required in order to comply with the standards and in these circumstances, it may therefore be difficult to determine whether the construction does comply. The Applicant provided a report from his own engineer WB, an engineer of 38 years experience. WB disagreed with the findings of SG but did not comment on the use of bottom cord ties on the truss. I do not accept that the evidence from SG establishes that there was no bracing. There is evidence of brick tie downs and dynabolts hanging from the trusses, evidence of cross bracing underneath the roof sheeting and evidence that the truss was supported by a hard wood beam. The Applicant has provided evidence that the work on the property was approved by the council and following inspection of the roof frame in April 1996, the building was considered suitable for occupation. In the circumstances, I am not satisfied the evidence as presented by the FSP is sufficient to establish on the balance of probabilities that at the relevant time when the property was built, it did not reach relevant building standards. I am not satisfied the FSP has established that the damage sustained was due to a defect, faulty workmanship, structural defects or faulty design. Other matters The Applicant has sought, in addition to the cost of repair of the home, the costs of having to purchase a shipping container to store items and the costs of engaging an engineer. I accept that the Applicant has incurred the additional cost to store the items. I am satisfied that the Applicant is entitled to be reimbursed for such costs incurred in accordance with the terms of the policy, subject to the Applicant providing a relevant invoice for those costs prior to payment of the same. Case No: 348411 Determination Page 4 of 7 Insofar as the Applicant’s claim for the cost of the engineering report, paragraph 9.4 of the Terms of Reference provide that FOS may decide an FSP contribute to such professional costs incurred in the course of a dispute. In determining whether an FSP should contribute to such costs, it is appropriate to consider the complexity of the issue in dispute, whether the expert assistance was required and whether it assisted in the dispute. The report from WB was brief. Whilst he disagreed with SG, he did not address the main issue that is, whether the roof required the truss be secured by bottom cord ties. The report was of limited assistance in resolving the dispute. In the circumstances, I am of the opinion the FSP should contribute 50% of the cost of obtaining the report subject to the Applicant providing the invoice to the FSP. Case No: 348411 Determination Page 5 of 7 3 Supporting information 3.1 Policy wording The following wording from the Product Disclosure Statement is relevant to this matter: “ Accidental Damage cover What is covered … We will cover your buildings and your cont ents for accidental loss or accidental damage. There is some loss or damage we will only cover under specific conditions. … What we will not pay for We will not cover your buildings and your contents for any accidental loss or accidental damage caused by:  …  A defect in an item, faulty workmanship, structural defects or faulty design. … Additional things we will pay for when you have insured your buildings If you have cover for your buildings, the following will be paid in addition to the sum insured as listed on your schedule. We will pay these costs when they relate to loss or damage caused by or arising from accidental loss or accidental damage that is covered by this policy:  …  We will pay the costs necessary to meet the requirements of any statutory authority in connection with rebuilding or repairing the buildings at the situation. We will not pay any costs which re sulted from any notice which a statutory authority served on you before loss or damage to your buildings occu rred. The most we will pay in any on period of insurance is $25,000.” 3.2 Expert evidence Record Key points Council Approval Documents Dated 1994 - 1996  Part A indicates the property was inspected by a building surveyor and approval was granted subject to conditions, on 31 May 1995. One of those conditions was “Engineer details of roof trusses being submitted to council prior to loading roof.”  Part C shows records of inspection. The only further inspection relevant to the roof was 26 April 1996. This reads: “Roof frame inspection. O.K. Spoke to owner re - flashings in wet areas.”  The building surveyor permitted occupation of the premises on 9 August 1996. FSP’s Builder ( RG )  House was not structurally stable and a make - safe was Case No: 348411 Determination Page 6 of 7 Report 12 December 2012 undertaken. The Applicant had removed the damaged roller doors and some bricks.  House has been impacted by something, probably not lightning.  Substantial damage done to garage and interior fittings.  Recommend a structural engineer to attend. FSP’s Buildin g Consultant ( SG ) Report 14 March 2013  Three roller doors and brickwork were observed as damaged and piled adjacent to the front of the garage.  There was no evidence of a lightning strike to the building.  The garage was constructed of single skin brick wal ls with engaged piers on a concrete slab.  Metal roof sheeting was supported by light gauge welded trusses at approximately 900mm centres.  There were no bottom cord ties from the steel truss at the front of the garage which would have tied it to the remai ning roof trusses.  The front wall of the garage had brick columns supporting three steel lintels over the roller doors which support five rows of double brickwork. The top of the double brickwork was tied to the bottom cord of the truss.  Australian Standar d (AS) 4440 details the installation of nailplated timber roof trusses, including appropriate bracing. The Applicant’s garage roof does not meet this standard.  The cause of the damage is due to racking forces from strong winds caused the partial collapse of the front wall of the garage due to failure of the installation of bottom cord ties attached to the bottom cord of the truss in accordance with AS 4440, section 4, clause 4.4.1. SG Supplementary Comments Report 21 August 2013  The correct AS applying to this property is AS 3623 – 1993 and states: “This Standard sets out the performance requirements, in terms of structural adequacy and serviceability, for the framing of domestic buildings of up to two storeys in height and roof pitches of up to 35  .”  Sect ion 2 of AS 3623 – 1993, part 2, clause 2.7.1 states, “Permanent bracing shall be designed to resist the wind forces specified in AS 4055. Bracing shall be as evenly distributed as practi cable and shall be provided in two orthogonal directions.”  SG is of t he opinion industry best practice before, during and after construction of the Applicant’s property is bottom cord ties are to be installed so the entire roof truss system is rigid and can resist racking by wind forces.  All truss manufacturers have required bottom cord ties since light weight trusses were first manufactured.  The roof truss installation is defective building work. FSP’s Engineer (KC) Report 1 March 2013  The damage noted is consistent with a storm event.  Due to the way the roof frame was constructed, no restraint was provided to the brick lintel at ceiling height Case No: 348411 Determination Page 7 of 7 which allowed the lintel to deflect inwards under wind pressures. The wall eventually collapsed during the storm event in question.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.