Home / Financial Firm (Unknown - Insurer) / Determination 347408
Determination 347408
Denial of water damage claim under building policy
Summary
The landlord applicant claimed water entry damage to a rented building after a February 2010 storm. AFCA found the damage most likely resulted from gradual deterioration and water entry not through a storm-made opening, so the FSP was not liable.
The insurer established exclusions for gradual deterioration, seepage from structural defects and water entering through openings not made by storm.
Issues
- Claim denial primary · not upheld“This Determination is in favour of the FSP. The FSP is not liable for the damage to the Applicant's home building”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of
Claim
Determination
Case No: 347408 Determination Page 1 of 5
Case number : 347408 1 9 September 2014
1 Overview
1.1 Dispute
The Applicant lodged a claim against his Landlord Insurance policy held with the
Financial Services Provider (FSP) after water entered his home in February 2010.
The FSP denied liability for the claimed damage on the basis that the water did
not enter through a storm created opening but had entered the building as the
result of structural defects, faulty workmanship or failure to adequately maintain
the building.
The Applicant disagrees with the decision and seeks a review by the Service.
1.2 Issue and key findings
Is the FSP liable for the damage to the Applicant’s building ?
The FSP is not liable for the damage to the Applicant’s building because:
the damage sustained to the property most likely occurred over a long period
of time resulting in the gradual deterioration of the building.
insofar as there was damage as a result of storm in February 2010, that
damage was not caused through an opening made by storm.
1.3 Determination
This Determination is in favour of the FSP.
The FSP is not liable for the damage to the Applicant’s home building and is not
required to reimburse the Applicant for costs associated with the repairs .
Case No: 347408 Determination Page 2 of 5
2 Reasons for Determination
2.1 Is t he FSP liable of the damage to the Applicant’s building ?
It is an accepted principle of general insurance law that an insured bears the onus
to establish that they have suffered a loss caused by an event to which the policy
responds. This is known as a prima facie claim. Once so established, the onus
shifts to the insurer to prove the application of an exclusion if it wishes to deny or
limit its liability for the loss.
The Applicant reported that water entered his building, which he rents out to
tenants, during a rainstorm in February 2010, and the FSP arranged for building
services firm “L S ” to report on the claimed damage.
The report from LS dated 26 February 2010 confirmed that rain had entered and
caused damage to various parts of the building, and it is therefore accepted that
the Applicant has established a prima facie claim under the policy insured event
of storm, rain and runoff.
The onus now shifts to the FSP to prove the application of an exclusion.
The policy provides a number of exclusions that apply to the damage.
The FSP argues that the following exclusions apply:
damage by water seeping into the building
damage caused by inherent defects, structural defects, faulty workmanship or
faulty design
damage caused by gradual deterioration.
There is no dispute that the damage occurred over time.
The Applicant maintains water first entered the property in 2007 during a storm.
The Applicant employed a roofing plumber to repair what he believed were the
leaks and attended to the other repairs himself.
Following the February 2010 storm, the Applicant appointed water proofing
consultants to carry out work on the property. The consultant BT identified the
structure had been exposed to water ingress over a long period of time and
considered that that led to the gradual deterioration of the balcony.
BT identified water had entered through a section of tiles and considered that
there was a failure of the water proofing to the dividing wall.
BT concluded that the damage observed was not as a result of a storm or a one
off incident where water had breached a building component but was a result of a
longer term exposure to the timber structure due to a failure of the balcony water
proofing.
The FSP obtained a report from a building service company LS. Following
inspection of the property, LS identified large quantities of silicone and other
sealants had been laid over the grout lines between the tiles as well as the
perimeter of the tile balcony. LS considered that the problem appeared to be due
Case No: 347408 Determination Page 3 of 5
to a failure of or omission of proper membraning at the time of construction. A roof
inspection report was obtained by the FSP from PBS. PBS considered the first
point of water ingress was related to roof drainage at the property where the
apron flashings at the property had not been properly installed. The second issue
was identified above the kitchen where the balcony is situated.
PBS considered that there were cracks in the mortar of the balcony tiles and drain
caps were missing.
PBS considered the water ingress was related to water proofing issues which is
commonly seen when water proofing has been done incorrectly.
The Applicant strongly disputes the comments of BT, LS and PBS and maintains
the property had been constructed correctly and the water proofing done
correctly.
The Applicant relies upon water spray tests conducted by P&C that showed water
ingress occurred via the doorways. According to the report from P&C the water
damage to the ceiling was due to faulty seals on the balcony door and window.
The Applicant relies on the report from P&C as evidence that there was not a
failure of the water proofing membrane.
The report from P&C is dated 18 August 2012 and follows an inspection on that
day. The report follows rectification works being undertake n by BT in 2010. BT in
the report of 10 January 2013 confirmed that the rectification work was water
(flood) tested and found to be water tight.
Having considered the reports as provided, I am persuaded by the reports
presented by the FSP that the damage sustained was most likely due to gradual
deterioration caused by water seeping, percolating or otherwise penetrating into
the building as a result of structural defects, faulty design, faulty workmanship
and/or the failure to adequately maintain the building. As such damage is
specifically excluded under the terms of the policy, I am satisfied based on the
information exchanged that the FSP has established the application of the
relevant exclusion.
Further, P&C concluded that the cause of the damage was due to faulty seals on
the balcony doors and windows. The policy specifically excludes damage caused
by wind, rain water, hail or snow entering the buildings through an open window
or door or any opening not made by the storm unless the loss is caused by runoff.
There is no suggestion that the damage was caused by runoff. P&C consider the
damage due to faulty seals. This is not damage caused by an opening made by
the storm and therefore would be excluded under the terms of the policy.
3 Supporting information
3.1 Report from LS
“My inspection was completed in the presence of the tenant who has lived there for
several years and who reported the ingress of rainwater was somewhat of an
ongoing matter that had certainly worsened in recent times and when you complete
Case No: 347408 Determination Page 4 of 5
a clo se and detailed inspection of the tiles balcony areas above (Fig. 4 & 5) it is
clear some effort has been made to stop rain penetrating beyond.
Large quantities of silicone and other sealants have been laid over grout lines
between tiles (Fig.6) as well as around the perimeter of these tiled balcony areas
(Fig.7) but the problem seems more complicated than that and I suspect that failure
of / omission of proper membraning at the time of construction is the primary reason
these problems have developed. ”
3.2 Rep ort from PBS Services
“INSPECTION :
Inspection of this property was carried out on Wednesday 22nd August. They
attended the property as requested to provide a report on damages sustained and
determine cause of water entry via roof.
ISSUE :
The first point of water ingress is situated in the lounge room, this is a minor
dripping which is related to the roof drainage at the property. The apron flashings at
the property do not have lips installed. This is a very poor design and the plumber
who installed the fl ashings, should have noticed these issues during the
installation…
The second issue is above the kitchen where the balcony is situated. There are
cracks in the mortar of the balcony tiles and drain caps missing. The water ingress
is related to water proofi ng issues from the balcony. This is commonly issue seen
with water proofing being done incorrectly.” (sic)
3.3 Report from BT
“ BT inspected the property and provided recommendations and a quotation to carry
out remedial repairs to an existing first floor balcony…
During my site inspection I observed the following issues in regards to the balcony:
Little or no provision had been provided at the door seal to the balcony detail
An attempt had been made by the owner to seal areas of the balcony with
silicone s ealant, in particular sections of tile grout lines which had cracked
and to the up stand detail beneath the timber door sill.
The balcony had some debries from the trees and I noted a large brown stain
clearly visible on the tiled area in front of the door .
Internal damage was observed to the ceiling are on the ground floor (sic)
In my opinion and experience the damage as observed during our time on site was
as a result of the structure being exposed to water ingress over a long period of
time which had gra dually caused deterioration of the timber building components at
the wall to floor area of the balcony located beneath the timber door frame and
adjacent weatherboard clad dividing wall….
The failure of the waterproofing to the dividing wall also indicated that the upstand
detailing of the balcony had failed at this junction detail.”
Case No: 347408 Determination Page 5 of 5
3.4 Report from P&C
“ I now proceeded to flow test the bedroom door and windows onto the balcony
area. I noted that this is not sealed properly and is therefore allowing rain water to
leak onto the bedroom floor in front of the door. This rain water is then tracking
into the ceiling below from where it is then causing the damage to the ceiling
below.
The balcony door of the 2 nd balcony was also flow tested and one can see that the
door does not seal properly and is therefore allowing rain water to leak through it.
In my professional opinion, the cause of water damage to the ceiling is due to
faulty seals on the balcony doors and window. ”
3.5 Policy wording
Words with special meanings
…
“rainwater” means rain falling naturally from the sky onto buildings and/or the ground.
…
“run - off” means rainwater that has collected on or has flowed across normally dry
ground or has overflowed from swimming pools or spas.
…
“storm” means vio lent wind (including cyclones and tornadoes), thunderstorms and
hail which may be accompanied by rain or snow.
…
Insured events we will pay
…
9. Storm, rainwater or runoff
…
We will pay for loss or damage caused by storm, rainwater or runoff.
We will not pay for loss or damage:
…
g. caused by water seeping, percolating or otherwise penetrating into the buildings
as a result of:
structural defects
faulty design of the buildings
faulty workmanship in the construction of the buildings; or
your failure to adequately maintain the buildings;
h. caused by wind, rainwater, hail or snow entering the buildings through an open
window or door or any opening not made by the storm, unless the loss or damage
is caused by runoff; or
...”
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.