Home / Financial Firm (Unknown - Insurer) / Determination 347171

Determination 347171

Denial of claim - Exclusion/condition

FirmFinancial Firm (Unknown - Insurer)
Decided2014-08-22
ProductGeneral Insurance · Business / commercial
OutcomeFor the complainant in part
Amount awarded$15,750
Non-financial loss—
Amount claimed$31,500
SourceAFCA PDF

Summary

The insurer denied a storm-damage claim for a collapsed retaining wall under the structural defects exclusion. AFCA found the insurer did not establish the defect was a direct cause, apportioned the loss equally, and ordered it to pay half the $31,500 repair cost plus interest.

Where multiple concurrent causes exist, the insurer must show an excluded cause was a direct cause, and a contributing structural defect alone does not defeat the claim.

Issues

Subjects and remedies

home or building damagenatural disasterpay claimpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim-Exclusion/ condition Determination Case No: 347171 Determination Page 1 of 5 Case number : 347171 21 August 2014 1 Overview 1.1 Dispute The Applicant holds a Commercial/Retail/Industrial Business Pack policy (the policy) with the insurer (FSP) to cover a business premises. The Applicant lodged a claim for damage to the retaining wall of the premises following a storm event on or about June 2013. The Applicant states the proximate cause of the damage to the wall was the storm and is therefore covered under the terms of the policy. The FSP denies the claim, based on an exclusion in the policy relating to structural defects in the retaining wall. 1.2 Issues and key findings Is the FSP entitled to deny the Applicant’s claim? The FSP is not entitled to deny the Applicant’s claim. There were multiple causes to the collapse of the wall. The FSP did not establish the structural defect was a direct cause of the collapse of the wall. It is fair in all the circumstances to apportion the loss equally between the Applicant and the FSP. 1.3 Determination This Determination is in favour of the Applicant. The FSP is required to meet 50% of the cost of the repair, plus interest in accordance with the Insurance Contracts Act. Case No: 347171 Determination Page 2 of 5 2 Reasons for Determination I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties. I am satisfied that the documentation I have relied on has been provided to both parties. 2.1 Is the FSP entitled to deny the Applicant’s claim? The policy provides cover for the collapsed wall except in the event of structural defects to the wall or subsidence The policy provides cover for damage to retaining walls caused by or arising from a storm (up to $25,000) subject to certain exclusions, including structural defects or faulty design as well as subsidence or settling. Burden of proof shifts in respect of the Applicant’s claim The onus rests with the Applicant to prove, on the balance of probabilities, he sustained a loss caused by an event insured for under the policy in force, at the date of loss. Once the Applicant satisfies this onus, the burden shifts to the FSP to establish the claim falls within an exclusion from cover. Insurer may deny claim where there are multiple concurrent causes but one cause is excluded under the policy Where there are multiple concurrent causes to the Applicant’s loss, the FSP need only establish that one of the causes is excluded by the policy in order to defeat the claim (Wayne Tank principle). The experts identified multiple causes to the collapse of the wall It is not in dispute that a storm event occurred and the water pressure from the storm ultimately led to the failure of the southern part the retaining wall (which was made of concrete blocks). However, there were multiple causes to the collapse of the wall, as supported by both the Applicant’s expert and the FSP’s expert. The Applicant’s expert (WE) observed two penetrations on the concrete driveway slab adjoining the property, within the vicinity of the failed portion of the wall. WE concluded the absence of adequate drainage off the neighbouring driveway led to a large volume of stormwater being directed at the two penetrations, which led to a build of up water pressure at the rear of the wall. WE said there was no evidence of subsoil drainage behind the wall to relieve the increase of water pressure. WE therefore identified three causes to the collapse of the wall: defects in the neighbouring driveway, defects in the retaining wall, and the storm. The FSP’s expert (K) concluded the failure of the wall was caused by the inadequate construction of the wall, which did not meet general engineering principles, including:  the lack of subsoil drainage behind the blocks Case No: 347171 Determination Page 3 of 5  there were no footings below the blocks  there were no connections between the blocks, and  the blocks were inadequately thick. K reported that these defects would have resulted in long term settlement and rotation and would have compromised the wall prior to the storm event. In support of this, K noted the northern portion of the wall that remained was leaning and bowed and concluded the southern part of the wall was most likely in this condition prior to the storm. K did not access the neighbouring driveway and therefore did not view the penetrations or the issues with surface drainage. K nevertheless concluded that while the penetrations would have increased the flow of water into the retained ground, it was not possible to predict to what extent. Further, suitable subsoil drainage would have reduced the likelihood of collapse. K maintained the primary cause of the failure was the inadequate construction of the wall. Structural defect to wall not a direct cause of its collapse The lack of subsoil drainage, confirmed by both experts, supports the conclusion the construction of the wall was inadequate to begin with. Further, both e xperts accept that the penetrations in the neighbouring driveway contributed to the pressure on the wall during the storm. The wall was approximately 43 years old. There is no evidence of any issues with the wall prior to the storm. That the remaining northern end of the wall had rotated after the storm does not support the conclusion that the southern part of the wall was leaning and bowed prior to the storm. This damage could have resulted from the storm. The blocks were four high in the northern section but only two high in the southern section, where the wall collapsed. The FSP has not established that the damage was caused by subsidence or settling. The inadequate construction of the wall is a structural defect and therefore excluded under the policy if it is a direct cause of the collapse of the wall. The FSP has not established that, given the period of time the wall had stood and the problems identified with the neighbouring property, that the structural defect was a direct cause of the collapse of the wall, but rather was a contributing factor. As such, the Wayne Tank principle does not apply. Apportionment of damage is fair in all the circumstances Given the multiple causes to the damage, I consider it fair in all the circumstances to apportion the loss equally as between the Applicant and the FSP. The Applicant has supplied a quote for repair works of $31,500. This has not been disputed by the FSP. Half the costs of the works is $15,750, which is within the $25,000 cap set out in the policy for storm damage to retaining walls. Interest is payable Interest is payable on half the costs of the repair works, in accordance with the Insurance Contracts Act, from denial of the claim until settlement. Case No: 347171 Determination Page 4 of 5 3 Supporting information 3.1 Expert evidence Record Key po ints FSP’s expert (K ) Report dated 4 August 2013  There is no evidence of footing below the blocks or subsoil drainage behind the blocks.  The retaining wall did not meet the requirements of relevant Australian standards or general engineering principles due to issues such as lack of footings below the wall, inadequate thickness of the blocks and lack of connections between the blocks.  The damage to the wall was due to the wall being inadequate and prone to rotation, settlement and possible collapse.  The damage to the northern section of the wall exhibited damage as a result of these long term effects.  The collapsed section of the wall was caused by the exacerbation of long term movements in response to the retained and supporting ground being ingressed wi th water.  Additional lateral loading occurred due to hydrostatic pressure behind the wall and additional settlement in the supporting ground. Applicant’s expert ( WE ) Report dated 3 October 2013  The concrete driveway slab had two penetrations of 100mm in diameter within the vicinity of the failed portion of the wall.  The absence of adequate surface drainage off the driveway led to a large volume of stormwater being directed at the two penetrations. This led to a build up of water pressure on the r ear of the wall.  There was no evidence of subsoil drainage behind the wall to relieve the rapid increase of the water pressure. K’s report dated 4 November 2013  K did not access the neighbouring property and therefore did not observe penetrations in the d riveway within the vicinity of the failed portion of the wall.  The penetrations would have most likely increased the flow of water into the retained ground. However, the increase in the development of hydrostatic pressure behind the wall cannot be quantifi ed. As such, it is not possible to predict how much this added to the problem.  Based on the remaining section of the wall, the failed section was likely to be leaning and bowed prior to the storm event due to long term settlement and rotation due to inadequate construction.  The lack of subsoil drainage contributed to the overall inadequacy of the construction of the wall. Case No: 347171 Determination Page 5 of 5 Record Key po ints  Even though adequate footings would have reduced the risk of settlement and rotation, the wall would still have been inadequate du e to thickness, lack of connections between the blocks and the absence of subsoil drainage. 3.2 Product Disclosure Statement “ Limitations of cover 6. Storm, rainwater, wind, hail or snow Cover for damage to …retaining walls caused by or arising from storm, rainwat er, wind, hail or snow is limited to a maximum of $25,000 in total, any one event. … Exclusions ... ... 3. We will not pay for damage caused by or arising from: ... (i) Erosion, landslide, mudslide, rockslide, subsidence, settling, seepage, shrinkage or expansion of earth, vibration or other earth movement, unless caused by or arising from a direct consequence of an earthquake, subterranean fire, volcanic eruption or water escaping from a wat er main owned by a water supply authority. 5. We will not pay for damage caused directly by or arising directly from: ... (d) latent defect, inherent defects, faulty workmanship, faulty material, structural defects or faulty design.”

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.