Home / Financial Firm (Unknown - Insurer) / Determination 345016
Determination 345016
claim_denial
Summary
The applicant's boat was damaged by electrolysis after repairs, and the FSP denied the claim relying on an electrolysis exclusion. AFCA found the repairer's negligence was the proximate cause, so the FSP must indemnify the claim, with interest if cash settled.
Under proximate cause principles the active cause was the repairer's negligence, so the general electrolysis exclusion could not be relied on to deny the claim.
Issues
- Claim denial primary · upheld“The FSP is not entitled to rely upon the exclusion for electrolysis, as the proximate cause of the loss was the negligence of the repairer.”
- Product terms interpretation secondary · upheld“The electrolysis exclusion cannot be looked at in isolation but must be considered in light of the proximate cause.”
- Repairs or contractors secondary · upheld“There was negligence on the part of the repairer which caused loss or damage to the Applicant's boat.”
Subjects and remedies
pay claimpay interest
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
General Insurance - Domestic Insurance - Personal and Domestic Property- Pleasure
Craft - FSP Decision - Denial of claim
Determination
Case No: 345016 Determination Page 1 of 4
Case number : 345016 2 3 October 2014
1 Overview
1.1 Dispute
The dispute relates to a claim for loss and damage to the Applicant’s boat, under
the Applicant’s Marine Insurance Policy , with the Financial Services Provider
(FSP).
The FSP has ultimately denied the Applicant’s claim on the basis that there was
no negligence on the part of the repairer and in any event that there is a specific
policy exclusion for any loss or damage caused by or resulting from, or the costs
incurred from or of, electrolysis.
1.2 Issues and key findings
Was there negligence on the part of the repairer that caused loss or damage
to the Applicant’s boat ?
The evidence establishes that there was negligence on the part of the repairer
which caused loss or damage to the Applicant’s boat.
Is the FSP entitled to rely upon the exclusion for electrolysis to deny the
Applicant’s claim?
The FSP is not entitled to rely upon the exclusion for electrolysis, as the
proximate caus e of the Applicant’s loss was the negligence of the repairer.
1.3 Determination
The Determination is in favour of the Applicant.
The FSP is required to indemnify the Applicant under the terms and conditions of
the policy.
Should the FSP cash settle any part of the Applicant’s claim, the FSP is required
to pay interest on that settlement, in accordance with the Insurance Contracts Act
1984 (the Act), from the date of denial of the claim until the date of the settlement.
Case No: 345016 Determination Page 2 of 4
2 Reasons for Decision
This Determination has been the subject of a Recommendation by the Service on
7 August 2014. It was the Case Manager’s Recommendation that the FSP was
required to make a payment of the claim in accordance with the policy terms and
conditions.
The FSP has disputed the Recommendation and has provided further
submissions in support of its denial of the Applicant’s claim.
I have carefully considered all of the material provided both before and after the
Case Manager’s Recommendation , in the preparation of this Determination.
2.1 Was there negligence on the part of the repairer that caused loss
and damage to the Applicant’s boat?
The Certificate of Insurance provided by the FSP confirms coverage in respect to
repairer’s negligence, where there is loss or damage to the Applicant’s boa t
caused by the negligence of any repairer engaged by the Applicant to repair the
boat.
It is not disputed that the repairer WDM, carried out repairs to the boat. The first
part of the dispute between the parties relates to whether the repairer was
negligent when completing the repairs.
Both parties have provided reports and submissions in respect to the work carried
out by WDM.
After having carefully considered the material, I am satisfied that there was
negligence on the part of the repairer which has led to loss or damage to the
Applicant’s boat.
In reaching this conclusion, I have given consideration to the following matters:
The repairer, WDM, accepts that the boat was not fitted with a Galvanic
Isolator. WDM agrees that all parties recommend that such an isolator should
be fitted to the boat. It is not clear to me as to why, when fitting a new engine
and engine coupling, WDM did not ensure that a Galvanic Isolator was fitted
to the boat.
Sufficient testing of the boat subsequent to the new engine and e ngine
coupling being fitted would have established whether or not electrolysis was
likely in the circumstances of the repair work which was completed by WDM.
After considering the evidence, I am not satisfied that WDM carried out
sufficient testing to overcome the potential problem which ultimately arose.
The missing isolator was repaired approximately 12 months after replacing the
engine and the Applicant’s statement that there has been no further damage
since that time has not been disputed.
Within correspondence of 24 April 2013, the FSP advised, “ On review of all
the information it’s clear that the repairer (WDM) has failed to properly test for
power continuity after the installation of the new motor ” . In a submission
subsequent to the Recommendation, the FSP acknowledges the
correspondence of 24 April 2013 and agrees that the contents as stated are
Case No: 345016 Determination Page 3 of 4
accurate but the FSP maintains that there was an error on the part of the
author of that correspondence. However, the FSP has made no effort to
explain what the error was or how it impacts upon the outcome of the dispute.
The Recommendation itself states , “T here is further no evidence of whether
the repairer did in fact run a continuity test to determine that everything was
operating correctly.” The material provided subsequent to the
Recommendation does not respond to this statement.
Having considered all of the available evidence, I am satisfied that the proximate
cause of the loss or damage to the Applicant’s boat is the repairer’s negligence.
2.2 Is the FSP entitled to rely upon the exclusion for electrolysis to
deny the Applicant’s claim?
The FSP seeks to rely upon the following exclusion to deny the Applicant’s claim:
“ General Exclusions
…
You are not covered for any loss or damage caused by or resulting from, or the costs
incurred from or of:
..
- Wear and tear, mould, gradual deterioration, timber rot, delamination, vermin, corrosion,
rust, electrolysis, osmosis or marine growth.
…”
In my view, the exclusion cannot be looked at in isolation, but must be considered
in light of the proximate cause of the loss or damage.
There is no dispute between the parties that the damage is electrolysis and as
stated above, in my view, the proximate cause of the damage is the repairer’s
negligence.
Case law has confirmed that the correct test for the proximate cause is the,
“ active, efficient cause that sets in motion a train of events without intervention of
any independent force.”
The proximate cause is not necessarily determined by the last event in line, but
rather the active or efficient cause that leads to the loss or damage.
As stated by the Case Manager, within the Recommendation, the electrolysis has
not occurred in and of itself to create the loss and damage. Rather the electrolysis
was the manifestation of t he repairer’s negligence and is merely the damage
resulting from the repairer negligence, not the proximate cause of the loss or
damage.
The FSP has pointed to the Service’s earlier Determination in dispute number
282911.
Firstly, the Terms of Reference of the Service make it clear that the Service will
not be bound by previous relevant decisions of the Service.
Secondly and in any event, Determination 282911 can be distinguished from the
current dispute on the basis that the electrolysis in 282911, was the proximate
cause of the loss and damage itself, rather than an insured event being the
proximate cause of the electrolysis.
Case No: 345016 Determination Page 4 of 4
The conclusion is that in the circumstances of the Applicant’s loss, the FSP is not
entitled to rely upon the specific exclusion, to deny the Applicant’s claim.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.