Home / Financial Firm (Unknown - Insurer) / Determination 343390

Determination 343390

Denial of house damage claim attributed to footing movement

FirmFinancial Firm (Unknown - Insurer)
Decided2014-09-01
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicants claimed for house damage they attributed to a neighbour's leaking water tank, which the FSP denied as long-term differential footing movement. AFCA found the damage was not caused by an insured event and the FSP was entitled to deny the claim.

Under an insured events policy the insured must prove the proximate cause of loss was an insured event, and the expert evidence shows the damage was from soil moisture changes in reactive clay.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance – Home Building - FSP Decision - Denial of claim-Exclusion/condition Determination Case No: 343390 Determination Page 1 of 4 Case number : 343390 2 8 August 2014 1 Overview 1.1 Dispute The Applicants lodged a claim under their home insurance policy with the Financial Services Provider (FSP) for damage to their property. The FSP denied liability on the basis the damage was due to long term, ongoing differential footing movement. The Applicants disputed this noting the damage was caused by their neighbour’s leaking water tank. 1.2 Issues and key findings Whether the FSP is entitled to deny the claim? The FSP is entitled to deny the claim because:  The Applicants’ policy is an insured events policy. The onus is on the Applicant to establish that an insured event caused the loss.  The evidence establishes that the damage was most likely as a result of differential footing movement unrelated to any water leak from neighbouring water tanks. The available evidence does not support that the damage occurred as a result of an insured event. 1.3 Determination This Determination is in favour of the FSP. The FSP is entitled to deny the claim. Case No: 343390 Determination Page 2 of 4 2 Reasons for Determination 2.1 Whether the FSP is entitled to deny the claim? The policy is an insured events policy The policy is an insured events policy that covers damage sustained as a result of certain specified events. In making the claim, the Applicants need to establish that the proximate cause of the damage was an insured event. The Applicants maintain that water from a neighbour’s water tank had been leaking under the Applicants’ house every time it rained. Under the terms of the policy this should be covered as damage caused by the escape of liquid. Was the water leaking from the neighbour’s water tank the cause of the damage? The Applicants maintain that water leaking from a neighbour’s water tank has entered the soil, causing foundational movement and subsequent cracking. This view is supported as the damage ceased once the neighbour addressed the issue. I note the FSP originally obtained a report from HCE following an earlier claim by the Applicant with respect to internal cracking to the home. That report dated 12 October 2012 identified that the cracking and movement in the home was as a result of differential movement occurring to the footings due to changes in the moisture content of the foundation material. The Applicants believed that the damage at the time was due to water escaping from a burst water main however HCE considered those problems were unrelated to a burst water main. The FSP obtained an engineering report from FM. Although the Applicant has expressed concern that FM did not conduct a thorough inspection, I am satisfied having considered the report that FM is appropriately qualified to provide an expert opinion on the matters in dispute. In a report dated 11 September 2013 FM considered that the foundation soils in the area were highly reactive clay soils. Prolonged water ingress as suggested by the Applicants would have caused swelling of the clay soils resulting in footing heave. There was no evidence of heave in the south-east corner of the building near where the neighbour’s water tank would have overflowed. The movement was most likely caused by differential soil moisture content in the reactive clay foundation and was not related to water escaping from the neighbour’s water tanks. In a further report of 14 March 2014, FM considered that whilst rainfall was a possible contributing factor, it was not the primary cause of the differential moisture content. Case No: 343390 Determination Page 3 of 4 FM concluded that the footing movements causing the damage were not consistent with an increase in the moisture content that would be expected from a leaking pipe. The Applicants have not provided any evidence to contradict the findings of FM or the earlier findings of HCE. The available evidence is persuasive that the ground movement that has caused the damage to the Applicants’ property was not caused by an insured event. As the Applicants are unable to establish an insured event was the proximate cause of their loss, the FSP is entitled to deny liability for the claim. 3 Supporting information 3.1 Expert Evidence Record Key points FSP’s expert ( HCE ) Report 12 Oct 2012  Cracking was identified in most internal areas of the house .  An inspection of the subfloor showed the foundation ma terial was dry at the time of inspection .  The inspection also showed an attempt to repair cracking and movement by installing additional stumps and packing and re - levelling the subfloor framing.  No heaving or efflorescence of relevant areas have occurred t o suggest that the sub - base below has become saturated from water escaping .  Water escaping from the burst water main has not drained to or concentrated around the house.  The cracking and movement is therefore a result of differential movement occurring of the footings due to changes in the moisture content of the foundation material.  It is also occurring due to the poor re - blocking and re - levelling of the subfloor framing.  These problems are unrelated to a burst water main. FSP’s expert (ALD ) Report 26 Aug 2013  Cold and hot water line pressure tested – passed .  CCTV camera inspection to stormwater line – passed .  All of the PVC stormwater in the house in very good condition .  No sewer in area of damage.  Possibly water coming from next door’s water tank overflow . FSP’s expert (FG) Report 11 Sep 2013  The subject site is relatively flat and is considered to have poor drainage .  The subfloor soils generally appeared dry but a localised puddle of water was observed to the south east corner of the dwelling. No leaks were located to explain the source of water ingress . Case No: 343390 Determination Page 4 of 4  The neighbour’s large water tank was near the south east corner of the building .  No structural damage observed. The observed distress in the property was limited to Categories 1 or 2 .  The foundati on soils are highly reactive clay soils. They experience volumetric changes with relative changes in moisture content .  Prolonged water ingress will swell the foundation clay soils resulting in footing heave. Based on the floor level surveys conducted, no evidence of heave at the south east corner of the building .  Conversely, floor level surveys indicate footing settlement toward the east side of the dwelling.  The building distress is due to normal and expected long term differential footing movement caused by differential soil moisture content variation in the reactive clay foundation as a result of one or more of the following: - Changes in soil moisture content - Drought conditions in Victoria - Inadequate drainage of the external perimeter - Recent low rainfall during Dec 2012 and Jan 2013 FSP’s expert (FG) Report 14 Mar 2014  The rainfall referred to in the previous report was a possible contributing factor .  However, it is not to be considered the primary cause of differential moisture content.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.