Determination 342387
Denial of claim
Summary
The applicant claimed for cracking and sinking of concrete around his pool, attributing it to a leaking spa pipe. AFCA found the proximate cause was gradual earth movement from rainwater entering a poorly designed joint, which the policy excludes, and ordered nothing.
The proximate cause of the damage was earth movement and faulty design, which are excluded under the policy, rather than an insured leak.
Issues
- Claim denial primary · not upheld“the FSP is not liable for the Applicant's claim.”
- Inadequate claim investigation secondary · not upheld“these assumptions were not critical to S's conclusions as to the cause of the damage.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of
claim
Determination
Case No: 342387 Determination Page 1 of 6
Case number : 342387 28 August 2014
1 Overview
1.1 Dispute
In June 2013, the Applicant lodged a claim under his home insurance policy with
the Financial Services Provider (FSP) for cracking and sinking damage to the
concrete area surrounding his swimming pool, which he believed had been
caused by a leaking water pipe.
The FSP denied the Applicant’s claim on the basis that the damage was not
caused by the leaking pipe or by any other event insured under the policy but was
due to earth movement, which is excluded under the policy.
1.2 Issues and key findings
Is the damage covered under the policy?
The available information establishes that the proximate cause of damage to the
concrete pool surrounds was earth movement which occurred gradually over time,
due to the poor design of the pool area which allowed rainwater run-off to enter
through a mortar joint between the pool tiles and the surrounding concrete slab
and run down behind the pool, eroding the soil under the slab.
The claimed damage was not caused by a leaking spa pipe and therefore does
not fall within the cover provided for this insured event. Further, the FSP is entitled
to rely on one or more relevant exclusions under the policy (for earth movement,
faulty design and/or gradual deterioration by rainwater) to deny the Applicant’s
claim.
1.3 Determination
This Determination is in favour of the FSP.
The FSP is not liable for the Applicant’s claim .
Case No: 342387 Determination Page 2 of 6
2 Reasons for Determination
2.1 Is the damage covered under the policy?
Application of policy depends on cause of damage
The Applicant’s policy is a defined events policy, which provides cover for
damage caused by certain specified events (including water leaking from pipes or
spas), subject to the conditions and exclusions set out in the policy.
The policy contains a general exclusion for damage caused by or resulting from
any earth movement not caused by an earthquake, including erosion, subsidence,
and collapse.
The Applicant says that the damage to the concrete pool surrounds was caused
by a broken pipe leading to the spa. He says that the leaking water from the spa
pipe caused the soil in the area to erode, which in turn led to subsidence and the
cracking and si nking of the concrete surrounds.
The FSP disagrees with the chain of causa tion described by the Applicant and
says that the underlying cause of the claimed damage was earth movement. The
FSP says that, if the spa pipe has in fact cracked and leaked, then this has
occurred as a consequence of earth mo vement in the area (rather than being the
cause).
In order to apply the terms of the policy, it is necessary to determine the
proximate cause of the damage to the concrete pool surrounds (that is, the real,
effective or predominant cause of the damage).
Proximate cause of damage was ongoing earth movement due to the effects
of rainwater run-off and the poor design of the pool area
On balance, the available information establishes that the proximate cause of
damage to the concrete pool surrounds was earth movement which occurred
gradually over time due to the poor design of the pool area which allowed
rainwater run-off to enter and run down behind the pool.
The engineer (S) appointed by the FSP to identify the cause of the damage
concluded that the primary cause was the poor design of the mortar joint between
the edge of the swimming pool and the surrounding concrete slab. S explained
that:
the joint should have been designed to include a kerb or upstand that would
have prevented rainwater from entering;
as it was, when the joint cracked and the mortar fell out, this allowed rainwater
to run through and down behind the pool, washing away some of the earth
under the slab and causing it to settle; and
this in turn caused the probable break in the spa pipes which resulted in the
flow of additional water from the pool, thereby accelerating the damage
process.
Case No: 342387 Determination Page 3 of 6
I consider that, as an engineer, S is appropriately qualified to determine the cause
of the cracking and sinking damage to the concrete pool surrounds. S’s report
provides a detailed and logical explanation as to how the damage occurred, which
is consistent with the photographs available.
The Applicant sa ys that S’s report should not be relied upon as it is highly
speculative and relies on broad assumptions about the manner in which the pool
has been constructed. In particular, the Applicant disputes S’s comments that the
backfill material around the pool was not highly compacted and the concrete slab
was not reinforced. The Applicant says that he was present when the pool was
built and can confirm that both these measures were taken.
While the non- intrusive nature of S’s investigations meant that he could not
confirm his assumptions about the backfill material and the lack of slab
reinforcement, I am satisfied that these assumptions were not critical to S’s
conclusions as to the cause of the damage. S identified the primary reason for the
flow of rainwater under the pool as being the poor design of the tile-slab joint,
which was easily visible in the photographs provided. The Applicant’s
submissions do not address this issue. Further, the Applicant has not provided
any independent information (for example, copies of the plans for the swimming
pool area or a report from his builder) to confirm that the backfill material was
sufficiently compacted and the slab reinforced.
The Applicant also disputes S’s findings on the basis that any rainwater run -off in
the swimming pool area was very minimal and did not run towards the area where
the crack is located. However, this is not consistent with the slope of the property
from north to south (as noted by S). Further, the Applicant had previously
mentioned the rainwater runoff to the FSP’s assessor, which suggests that at the
time he considered it to be significant.
The Applicant has not provided any independent information (such as a report
from his own engineer) which refutes the findings in S’s report or supports the
Applicant’s position that the real or effective cause of the cracking and sinking
damage was the leaking spa pipe.
In the circumstances, I am satisfied that, on the balance of probabilities, the
damage to the concrete pool surrounds was caused by ongoing earth movement
resulting from rainwater run-off running through the openings in the poorly
designed tile/slab joint, and not a leaking spa pipe.
Damage is excluded under policy
The Applicant’s policy contains general exclusions for earth movement and
damage caused by faulty workmanship o r design. The insured event of “Storm,
rainwater and flood” also contains a specific exclusion for gradual deterioration
caused by rainwater.
Given my findings as to the cause of damage, I am satisfied that the FSP is
entitled to rely on one or more of these exclusions to deny the Applicant’s claim.
Case No: 342387 Determination Page 4 of 6
3 Supporting information
3.1 Terms of policy
Subject Terms
Leaking of water Insured event – you are covered for loss or damage to your
home or contents caused by ...
Bursting, leaking, discharge or overflow of water or liquids
from pipes, taps, dishwashers, washing machines, baths, spas,
sinks, toilets, basins, hot water systems, refrigerators, air
conditioners, roof gutte rs, rainwater down pipes, drainage and
sewerage systems or aquariums at your home.
Rainwater Insured event – you are covered for loss or damage to your
home or contents caused by ...
Storm, rainwater and flood
Our exclusions (see also General Exclusions , pg [xx] ) – you
are not covered for
Loss or damage : ...
c aused by gradual deterioration from rainwater
General e xclusion s You are not covered for any loss or damage caused by or
resulting from:
inherent defects, structural faults, faulty workmanship o r faulty
design; ...
any earth movement not caused by earthquake, including
erosion, subsidence, landslide, mudslide, collapse, earth
shrinkage and expansion …
3.2 Reports
Report Key points
FSP’s assessor (A)
Report – 28 August
2013
The Applicant had advised him that in June 2013 the water
level in his swimming pool had dropped below the spa jet
outlets and water was seeping into his neighbour’s yard.
When the Applicant temporarily blocked the spa outlets and
refilled the pool, the le vel of the pool remained constant and
the seepage of water ceased.
The Applicant had also advised that during extended periods
of rain, runoff from a higher neighbouring property had
entered his yard.
His inspection revealed that sections of the concrete slab
path area had cracked and subsided and there were cracks
in the retaining wall adjacent to the subsided concrete path.
The damage has been caused by a combination of age,
ground movement/settlement and inadequate design.
A section of ground adjacent to the pool and its plumbing
Case No: 342387 Determination Page 5 of 6
Report Key points
ha d subsided , causing sections of the concrete path
surrounding the pool to sink and drop. This in turn appears
to have caused a crack in the plumbing to the spa section of
the pool. However, an eng ineer would need to be appointed
in order to confirm the cause of the damage .
FSP’s engineer (S )
R eport – 27
September 2013
The house was built about 15 years ago and the pool area
(which incorporates the spa) was developed about 2 years
later. The block slopes steeply downward from north to
south.
While the spa pipes are located mostly under concrete and
therefore have not been uncovered, it is reasonable to
assume that at least one of them is broken.
A wide expanse of the concrete slab at the southern en d of
the pool (where the spa is located) has settled, opening a
gap of up to 15 millimetres in the mortar joint between the
underside of the tiles surrounding the pool and the top of the
slab.
The greater part of the settlement has occurred between a
straight construction joint on the eastern side and a random
crack on the southern side. The damage is worse closer to
the pool.
The movement in both the joint and the crack indicate that
there may not be any reinforcement in the slab and that it
may have been simply poured over a sand base on natural
earth.
Much of the mortar in the joint between the pool tiles and the
concrete has broken out , allowing water to run into the gap
in the joint . This breakage does not appear recent and may
have been occurring over several years.
As t here is no drainage syst em in or around the slab, it is
highly probable that much rainwater has flowed into the gap
in the tile - slab joint and down behind the pool .
It is likely that s ome of t he excavated material from the pool
area has been used as backfill around the pool. This
material would likely not have been compacted to a very
high standard or provided with subsoil drainage. When water
flowed into it, it would readily form aquifers that al low the
water to drain to lower areas, such as the neighbour’s
property.
Settlement at the southern end of the pool has been
occurring gradually over several years as soil lea ched away
from under the slab. This f low would have accelerated when
the slab set tled and cracked allowing more water into the
sub - base. It is probable that this only became noticeable
when the settlement caused the spa pipe to break.
The settlement is unlikely to have been caused by changes
in the moisture content of the surrounding earth which, due
to its nature, exhibits practically no reaction to changes in
moisture content.
Case No: 342387 Determination Page 6 of 6
Report Key points
The more likely cause is leaching away of the earth under
the slab due to rainwater runoff, which has been caused by
the poorly designed joint between the sla b and the edge of
the pool that has allowed water to flow into it and then under
the slab. The j oint should have been designed to keep water
out of it.
The settlement of the slab has increased to the point that
pool piping embedded in the earth under the s lab has
broken.
FSP’s engineer (S)
Response to
Applicant’s comments
– 10 January 2014
As explained in his earlier report, the damage was caused
when the joint between the edge of the pool and the
surrounding concrete slab cracked and the mortar fell out,
causing water to run through and down behind the pool and
then to run through the earth under the slab to the
neighbour’s yard. The water washed away some of the earth
under the slab, causing it to settle which probably caused a
breakage in the spa piping , which induced water flow from
the pool, accelerating the dam a ge process.
The prime cause of the damage was the very poor design of
the joint, which should at least have included a kerb or
upstand that would have prevented the rainwater from
running down behind the pool and into the earth under the
slab.