Home / Financial Firm (Unknown - Insurer) / Determination 340453

Determination 340453

Denial of water damage to investment apartment under gradual deterioration exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2014-09-01
ProductGeneral Insurance · Strata
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The owner of an investment apartment claimed water damage from a storm event under a strata title policy, which the FSP denied under exclusions. AFCA found the real cause was gradual deterioration and lack of maintenance, so the claim was excluded and no payment was ordered.

On the balance of probabilities the proximate cause was excluded gradual deterioration, lack of maintenance and faulty workmanship, which the insurer bore the onus of establishing.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Residential Strata Title - FSP Decision - Denial of claim-Exclusion/ condition Determination Case No: 340453 Determination Page 1 of 7 Case Number: 340453 1 September 2014 1 Overview 1.1 Dispute In May 2013, the Applicant lodged a claim under a residential strata title insurance policy with the Financial Services Provider (FSP) which provided cover for his investment apartment. The Applicant’s claim was for water damage to the timber flooring and skirtings in his apartment, which he said was caused by heavy rainfall in May 2012. The FSP denied the Applicant’s claim on the basis that the damage occurred over an extended period of time and was caused by factors which were excluded under the policy, such as faulty materials or workmanship, gradual deterioration and/or lack of maintenance. 1.2 Issues and key findings Is the water damage covered under the policy? The engineers’ reports obtained by both the Applicant and the FSP establish that, on the balance of probabilities, the water damage to the Applicant’s apartment was caused by a combination of gradual deterioration and lack of maintenance and not by the storm events on 2 May 2012. Damage caused in this manner is not covered under the policy. 1.3 Determination This Determination is in favour of the FSP. The FSP is not liable for the Ap plicant’s claim. Case No: 340453 Determination Page 2 of 7 2 Reasons for Determination 2.1 Is the water damage covered under the policy? Application of policy depends on cause of damage Section 1 of the strata title policy provides cover for accidental damage to the Applicant’s investment apartment, subject to the conditions and exclusions set out in the policy. The cover provided under Section 1 is subject to specific exclusions for damage arising directly or indirectly out of or in any way connected with:  faulty materials or faulty workmanship;  lack of maintenance or any other failure to keep the building in good repair; or  wear and tear, gradual deterioration, normal upkeep or making good. The Applicant says that the damage to his apartment occurred as a result of torrential rainfall on or around 2 May 2012, which, together with a blockage in the building’s drainage system , caused water to overflow into the apartment, damaging the timber floating floor and wall skirtings in several rooms. However, the FSP says that the damage was not caused by a si ngle incident but occurred over time due to a combination of the breakdown of the sealants in the window/wall joint and poor maintenance of the balcony drainage systems. Accordingly, it is necessary to determine the proximate cause of the water damage to t he Applicant’s apartment (that is, the real, effective or predominant cause). As the FSP is seeking to rely on a policy exclusion to deny the Applicant’s claim, it bears the onus of establishing that, on the balance of probabilities, the relevant exclusion applies. Damage was caused by factors excluded under the policy Although water entered the Applicant’s apartment during one or more rainfall events, the available information establishes that, on the balance of probabilities, the real or effective cause of the damage was gradual deterioration and a lack of adequate maintenance. The consulting engineer (O) appointed by the FSP to inspect the damage concluded that it had been caused over an extended period of time by a combination of:  the failure of the seals between the windows, walls and balcony paving due to gradual deterioration and inadequate maintenance and repairs, which had allowed water to enter through the joins in these areas; and  poor maintenance of the balcony drainage systems, which had allowed leaves and other debris to build up, particularly around the air conditioner condensers , thereby preventing effective drainage . I consider that, as an engineer, O is suitably qualified to determine the cause of the water entry to the Applicant’s apartment . O’s report is detailed and comprehensive, and was prepared following a thorough inspection of the Case No: 340453 Determination Page 3 of 7 property. O’s report separately c onsiders each of the areas in which water damage was identified and provides a logical and reasonable explanation as to how water entry occurred in each case. O’s explanation is consistent with the nature and location of the damage as shown in the photographs provided. The Applicant disputes O’s findings as to the cause of the damage. He says that the damage occurred during the storms on 2 May 2012 when strong winds blew leaves and other debris onto the roof of the building, where they blocked the box gutter which, together with the torrential rain, caused the water table in the box gutter to rise and overflow inside the apartment via the roof cavity between the box gutter and the roof decking. The Applicant says that water then travelled alongside the internal wall before coming to an end where the floor meets the wall, resulting in damage to the floorboards and skirtings. However, I do not consider that the information provided by the Applicant is sufficient to refute O’s findings and establish that the damage was caused in the manner he has described. In this regard, I note that:  O expressly dismissed the suggestion that the damage had been caused solely by the storm events on 2 May 2012. While the Applicant says that O did not give sufficient weight to the extent of rainfall which occurred, it is apparent from O’s report that he accepted that the re had been considerable rainfall in the local area on the relevant date;  the Applicant’s position that the damage was caused solely by the storms on 2 May 2012 is inconsistent with the fact that there was still significant moisture in the skirtings in June 2013 (as shown by the moisture tests carried out by the FSP’s builder (S )); and  while the Applicant has provided photographs of the box gutters showing a build-up of leaves and debris, these photographs are undated and there is nothing to indicate that this build-up occurred solely as a result of the storms on 2 May 2012, rather than on an ongoing basis due to lack of maintenance (as indicated by O). The Applicant has provided a relatively brief report from his own engineer (P) which states that the claimed damage was caused by the failure of the waterproof membrane at the junction between the concrete slab in the common landscaped area of the building and the precast wall and waste outlet. However, P’s conclusion as to the cause of damage is not consistent with the explanation provided by the Applicant. Further, even if P’s vi ews are accepted, the damage would still be excluded from cover under the policy exclusions for gradual deterioration and lack of maintenance (or, if the original installation of the waterproof membrane was faulty, under the exclusion for faulty materials or workmanship). Accordingly, for the reasons outlined above, I am satisfied that, on the balance of probabilities, the real, effective or predominant cause of the water damage to the Applicant’s apartment was not the storm events of 2 May 2012, but the factors referred to above which are excluded under the policy. Case No: 340453 Determination Page 4 of 7 3 Supporting information 3.1 Terms of policy Subject Terms Cover provided under Section 1 Subject to the terms, conditions, exclusions and limitations applying to Section 1 (including those applying to all Sections of the Policy), We agree to indemnify You in accordance with the Basis of Settlement applicable to Section 1, up to the Limit of Liability applicable to Section 1, agains t Damage to:  Any Building and  Common Area Contents ... occurring during the Policy Period. Definition of Damage Any accidental physical loss, destruction or damage to Insured Property that has the result of lessening its value. Section 1 exclusions In addition to the general exclusions applying to all Sections of the Policy, We will not pay for ... 4. Damage arising directly or indirectly out of or in any way connected with …  faulty materials or faulty workmanship ...  lack of maintenance or any other failure ... to keep any Insured Property in good repair  wear and te ar, corrosion ... gradual deterioration or developing flaws ... normal upkeep or making good 3.2 Reports Report Key points Plumber appointed by building manager (C) Report – 26 June 2012 (as referred to in M’s report (see below))  His inspection revealed that the seal between the balcony and the building had perished and needed replacing.  He cleaned, dried, taped and re - sealed the area.  He also drained the box gutter and removed a bucket load of polystyrene and plastic from a blocked downpipe. FSP’s managemen t services company (M) (incorporating assessment by builder (S)) Report – 13 June 2013  S has confirmed that, in the areas where water had entered the apartment, the floor of the apartment was higher than the balcony floor. According ly, it is unlikely that water has entered through these areas.  Further, S has confirmed that moisture readings of the affected skirting boards (for example, in the living room) show that they a re still saturated. As the area between the balcony and the building was re - sealed by C in June 2012, this cannot be the cause of the water entry .  S considered it more likely that rainwater had entered the apartment through the un sealed vertical join s where the Case No: 340453 Determination Page 5 of 7 Report Key points window frame meets the pre - cast concrete panels of the wall , rather than through the seals between the balcony floor and the building (as indicated by the plumber (C)) . FSP’s engineer (O) Report – 12 July 2013  The building is approximately 11 years old.  The damage to the lounge room starts adjacent to the down pipe / floor waste unit on the balcony next to the window and runs for 5 metres along the west wall. The damage in the master bedroom appears to have been caused by moisture travelling across/under the wall plate from the lounge room side.  The damage in these areas was most lik ely caused by water entering through the building facade via the junctions of the window frame and the facade and terrace. This area of the facade is the most exposed to prevailing winds and rain. The fact that the water damage starts next to the windows, together with evidence of recent resealing in this area, suggests a causal connection.  The moisture readings carried out by M indicate that the problem in this area has not been corrected by the repairs carried out by P in June 2012. While the vertical joi nt between the window jamb and the pre cast wall was resealed, this is probably faulty and will need stripping out and resealing. The caulking under the window sill should also be replaced.  There is water damage in bedroom 2 in and around the corner window , which faces onto the north - east terrace where the balustrade at this end of the terrace is set back from the wall. The gap is also at a low point in the terrace and surface water tends to migrate across to this opening and drop over the side at the end o f the terrace. There is a build - up of dirt and moss growth along the length of the window sill, which has created an effective pathway for moisture to migrate from the terrace under the window sill and into the apartment.  There is an air conditioner conden ser at the other end of the window in bedroom 2, which has an extensive build up of debris and a significant amount of water around it. There is no evidence of a dedicated condensate drain point / floor waste. The location of the damage points to the conde nser as the likely cause.  His experience of similar buildings suggests that poorly maintained terraces and water points contribute to the downgrading of the drainage systems, allowing water to enter apartments. In this case, the build up of organic matter and misdirected water back to the sill line has in all probability provided a pathway for water into the bedroom. The absence of any obvious sealant to the vertical joints at the window jambs may also have contributed to the problem, although to a limited extent.  There was water damage to the north and east walls of the upper level TV room extending approximately 3 metres along Case No: 340453 Determination Page 6 of 7 Report Key points each wall. The building manager had advised that this area had been repaired after having previously suffered water damage.  The dam age to the TV room appears to have been caused by the location of the air conditioner condenser, the lack of an effective drainage point and the failure of the sealant between the wall and the terrace paving, which has contributed to water getting under th e wall, across the slab and through to the TV room. There was also a cracked and leaking downpipe which is likely to have contributed to the water leak into the north wall.  The water damage to the apartment was not caused by any one rain event but was the result of many rain events over a period of time. It was not surprising that damage appeared in 2012, as by that time the original caulking/sealant compounds used in the construction of the building were over ten years old. Assuming they were the more com monly used water soluble type, they would by that time be reaching their normal life expectancy. For this reason, the facades of high rise buildings should have their sealants replaced as part of long term maintenance.  In summary, the main cause of the wat er entry is due to a combination of a breakdown of the sealants and poor maintenance of the terrace drainage systems, particularly around the air conditioner condensers. A lack of maintenance to the down pipe on the north wall had also contributed to the w ater problems in that area. Applicant’s engineer (P) Report – 26 February 2014  The water damage is confined to the southern side of the apartment between the bedroom and living area, adjacent to a down pipe and floor waste on the upper balcony next to the windows.  The water damage has affected the plasterboard, skirting and floating floor. There is also evidence that water in penetrating through the cracks in the upper balcony slab as seen by the build - up of efflorescence on the soffit of the balcony slab. It is also evident that some attempts have been made to reseal some of the external joints between the paver and the wall and the window sills to the balcony slabs. However, this would be only a short term solution.  For the type of construction (with exte rnal floor areas), the slabs need to have a waterproof membrane applied to the external surface to prevent entry of storm water and overflow from sprinklers in the garden beds.  It is likely that the entry of water into the Applicant’s apartment is as a res ult of the failure of the waterproof membrane at the junction of the common area slab to the precast wall and the outlet waste. Case No: 340453 Determination Page 7 of 7

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.