Home / Financial Firm (Unknown - Insurer) / Determination 340174

Determination 340174

Denial of property damage claim under earth movement and cracking exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2014-06-26
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The owner of an industrial unit claimed for broken sewer pipes, slab movement and cracking. The FSP denied under the earth movement and cracking exclusions. AFCA accepted the engineers' evidence that long-term subsoil settlement was the proximate cause, not a burst pipe, so the FSP is not liable.

The proximate cause was long-term settlement of the subsoil, so the earth movement exclusion applies and the 72-hour burst-pipe carve-out does not.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Small Business/Farm Insurance - Commercial Property - FSP Decision - Denial of claim Determination Case No: 340174 Determination Page 1 of 6 Case number : 340174 23 June 2014 1 Overview 1.1 Dispute The Applicant is the owner of a unit located in an industrial property which is insured under a building and common contents insurance policy with the Financial Services Provider (FSP). In June 2013, the Applicant lodged a claim for damage to the amenities area of the unit. The damage included broken sewerage pipes, movement of the concrete slab and cracking of the tiles and ceiling. The FSP denied the Applicant’s claim on the basis that the damage was cracking damage and/or was caused by earth movement, each of which is excluded under the policy. 1.2 Issues and key findings What was the cause of the damage? The engineers ’ reports obtained by the parties establish that the proximate cause of the damage was the settlement of the subsoil underneath the sewer pipes at the property over an extended period of time, which caused the pipes to crack and water to leak out, resulting in the claimed damage. Is the damage covered under the policy? No. As the proximate cause of the damage was long term settlement of the subsoil, the FSP is entitled to rely on the policy exclusion for earth movement to deny the Applicant’s claim. The policy also excludes cracking damage of the type claimed by the Applicant. 1.3 Determination This Determination is in favour of the FSP. The FSP is not liable to pay the Applicant’s claim . Case No: 340174 Determination Page 2 of 6 2 Reasons for Determination 2.1 What is the cause of the damage? Application of policy depends on proximate cause of damage The Applicant’s policy provides cover for accidental damage (being damage caused by a sudden, unexpected and unintended event), subject to the conditions and exclusions set out in the policy. The Applicant says that the damage was caused by a burst sewer pipe which caused water to run into the earth, resulting i n earth movement. He says that the damage resulting from the burst pipe should be covered under the policy as “accidental damage”. However, the FSP says that the damage was caused by earth movement, which is specifically excluded under the policy. The policy contains an exclusion for damage “directly caused by” earth movement (including subsidence, seepage, saturation, shrinkage, settling, expansion or heaving). However, this exclusion does not apply to damage which occurs as a direct result of, and within 72 hours of, water overflowing, leaking or bursting from a fixed pipe (which is subject to cover). In order to determine whether or not the damage is covered under the policy, it is necessary to identify which, out of the possible causes suggested, is the proximate cause of the damage (that is, the real, predominant or effective cause). Proximate cause of damage is long term settlement of subsoil The engineers ’ reports obtained by both the Applicant and the FSP confirm that the real, predominant or effective cause of the claimed damage is the long term settlement of the subsoil underneath the sewer pipes, which has caused the pipes to crack. In his report dated 11 July 2013 , the FSP’s engineer (H) stated that: “the cracking and movement at the site have resulted from the waste pipes initially dropping and cracking due to long term settlement of inadequately compacted fill material (or excavated soil) below the pi pes”. While H acknowledged that the consequential escape of water from the cracked pipes had contributed to the damage at the property, he clearly identified the underlying cause of the damage as being the settlement of the fill material or excavated soil below the pipes over an extended period of time. The photographs included in H’s report clearly show the void under the concrete slab where the fill material or excavated soil has been washed away. H has confirmed that the slab would originally have been poured on top of the fill material with no void between the two. Case No: 340174 Determination Page 3 of 6 T he Applicant’s engineer (V) noted that the damage was due to the effects of the broken pipe. However, he also concluded that the underlying cause of the breakage was due to the pipe not having been properly secured in bedding or the soil underneath it having been poorly compacted, which caused the pipe to move over time and led to its eventual fracture. Accordingly, I am satisfied that both engineers have identified a chain of events that occurred over time, beginning with the settlement of the subsoil, followed by the movement and cracking of the sewer pipe. The cracked pipe resulted in water leaking into the surrounding subsoil, washing away the fill material and causing further settlement. This ultimately caused the movement of the concrete slab and the cracking of the tiles in the amenities area. The Applicant says that the damage cannot have been caused by settlement as in this case it would have become apparent much earlier. He says that the building has been in good condition since it was constructed in 1984 with no signs of cracks. The Applicant has not provided any information which establishes the condition of the building prior to the current claim. In any event, it is possible that the damage caused by the long term settlement of the subsoil was not immediately noticeable and only became apparent when it finally caused the sewer pipe to crack. It has also been suggested that the claimed damage was caused by the footings at a nearby building undermining the insured premises or by works undertaken during the construction of that building. However, I am satisfied that the supplementary report prepared by FSP’s engineer (H) specifically excludes this as a possible cause of the damage, having regard to the location of the claimed damage relative to the nearby building. 2.2 Is the damage covered under the policy? Policy exclusion for earth movement applies As outlined above, the policy excludes cover for damage caused by earth movement, except where the damage occurs as a direct result of, and within 72 hours after, the escape of water from a burst pipe. In my view, the carve-out for damage caused by earth movement following the escape of water from a broken pipe is intended to provide co ver in circumstances where the broken pipe itself is the underlying event which causes subsequent earth movement and property damage. In the current case, the engineers’ reports establish that the underlying event which caused the damage was the settlement of the subsoil, which was occurring for an extended period prior to the escape of water from the sewer pipes. The FSP’s engineer (H) has noted that the dusty nature of some of the cracks indicates that the earth movement is likely to have occurred several years ago. Case No: 340174 Determination Page 4 of 6 In these circumstances, the damage has not occurred “as a direct result of” and within 72 hours of the broken pipe, but rather as a result of earth movement over time which has led to various consequences, including the pipe breaking. Accordingly, I consider that the FSP is entitled to rely on the policy exclusion for earth movement to deny the Applicant’s claim. Policy excludes cracking damage The policy excludes cracking damage of the type claimed by the Applicant unless such damage is caused by fire, lightning, earthquake, storm, explosion, burglary, theft, vandalism or impact by a vehicle, aircraft or aerial device. There is no suggestion that the damage which is the subject of the Applicant’s claim was caused by any of the events listed. Accordingly, to the extent the damage consists of cracking damage, it is also excluded under the policy on this basis. 3 Supporting information 3.1 Terms of policy Subject Relevant term Exclusion for earth movement Your policy does not insure you against: 1. damage directly caused by : ...  earth movement no matter how caused, including erosion, vibration, subsidence, seepage, saturation, creeping, landslide, mudslide, collapse, shrinkage, settling, expansion or heaving, unless the loss or damage occu rs as a direct result of: (a) earthquake; or (b) water overflowing, leaking or bursting from a fixed pipe or fixed system and that loss or damage occurs within 72 hours of such overflowing, leaking or bursting. Exclusion for cracking damage Your policy does not insure you against: 4 . damage that is ...  cracking (other than cracking of bath tubs, shower recesses, wash basins, sinks, toilet bowls and cisterns) ... unless caused by fire, lightning, earthquake, storm, explosion, burglary, theft, vandalism or impac t by a vehicle, aircraft or aerial device. Case No: 340174 Determination Page 5 of 6 3.2 Expert reports Expert report Conclusion FSP’s engineer (H) Initial report dated 11 July 2013  An inspection of the premises revealed that the waste pipes had dramatically dropped, were cracked and broken and some were blocked. A large void was evident between the top of the fill material and the bottom of the concrete slab.  The pipes had been laid within fill material or from backfill of the excavated soil for the trench for the concrete footing below the wall panels.  The extent of the cracking and movement of the waste pipes indicates that they were laid within fill material or excavated soil that was not adequately compacted.  As long term settlement of the fill material/soil has occurred, the bottom of t he pipes has lost support and cracking and movement have subsequently occurred.  Water escaping from the cracked and broken pipes has then saturated the fill material/soil which has further added to the settlement of the fill material/soil and also washing away of the fill material/soil.  Settlement and washing away of the fill material /soil has caused subsequent settlement of the concrete slab from the loss of support to the underside of the slab. Cracks have then occurred in the tiles and ceiling of the ame nities area. FSP’s engineer (H) Supplementary report dated 12 September 2013  A further inspection of the premises and surrounding area confirmed H’s opinion (as set out in his initial report) as to the cause of the damage.  A more extensive inspection of the soil underneath the infill concrete slab was possible because of the plumbing works. This confirmed that the fill material was most likely excavated soil.  The fill material contained fine tree roots which appeared to be from mature trees in a reserve a djoining the property. These may also have contributed to the settlement of the fill material and the subsequent cracking and movement in the amenities area.  These problems have not resulted from the construction works within the adjoining building as ther e were no problems evident in the concrete wall panels closest to the building works. Applicant’s engineer (V) Report d ated 10 February 2014  The floor had settled causing gaps to the walls.  It appeared that the waste pipes had fractured causing water and water spreading into the surrounding fill causing the foundation material to be saturated causing the surrounding material to settle. Case No: 340174 Determination Page 6 of 6 Expert report Conclusion  There is no evidence of trees in the reserve causing the damage to the floor.  The damage is due to the effects of the brok en waste pipe. The cause of the broken pipe is now difficult to determine but is most likely due to the pipe not being secured in bedding or poor compaction leading the pipe over time to move and eventually fracture.