Home / Financial Firm (Unknown - Insurer) / Determination 339839

Determination 339839

Denial of building damage claim attributed to reactive soil movement excluded under policy

FirmFinancial Firm (Unknown - Insurer)
Decided2014-07-21
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

An investor policyholder claimed for building damage from storm and flood water runoff, while the FSP said the damage was caused by excluded soil movement. AFCA's panel found the claim was not brought within the policy's 72-hour terms and that the dominant cause was reactive soil and construction, so it ordered nothing.

A defined-events policy responds only to listed events, and the insurer may rely on the earth movement exclusion where the excluded cause is dominant.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim Determination Case No: 339839 Determination Page 1 of 6 Case number : 3 3 39839 21 July 2014 1 Overview 1.1 Dispute The Applicant holds an investor insurance policy with the Financial Services Provider (FSP) for which a claim was lodged on 29 February 2012 in respect of damage sustained to the building. The Applicant says the damage arose as a result of storm and flood water runoff which caused damage to the property. The FSP denied the claim on the basis the damage is not the result of any insured event but rather occurred as a result of soil movement, which is specifically excluded under the terms of the policy. The Applicant disputes that decision. 1.2 Issues and key findings Was the FSP entitled to decline the claim? The FSP was entitled to decline the claim because:  the Applicant has not discharged the onus on him to establish a valid claim under the policy  the loss arises from causes specifically excluded from cover under the policy. 1.3 Determination This Determination is in favour of the FSP. The FSP was entitled to decline the claim as the loss did not arise from any of the insured events but rather arose from causes specifically excluded from cover. This decision has been made by a Panel consisting of an Ombudsman and two representatives with consumer and insurance expe rience. Case No: 339839 Determination Page 2 of 6 2 Reasons for Determination 2.1 Was the FSP entitled to decline the claim? The damage did not arise as a result of an insured event The FSP’s policy is a defined events policy. Therefore, the policy only responds where the damage has been caused by o ne or more of the listed events, subject to any exclusions. One of these listed events is storm and flood. The onus rests with the policyholder to establish that a loss has been suffered which is covered by the terms of the contract. Once the Applicant has discharged this onus, it then shifts to the FSP to demonstrate that one or more of the listed exclusions operates to defeat the claim. The Applicant initially asserted the damage was caused by a storm and/or flood water saturation of the soils during the extreme weather events in south western Queensland in 2011 and specifically November 2011. The saturated soils caused the foundations of the building to move and occasioned damage to the property. However, the later history gathered by engineers D and C refer to flooding in January 2011. The policy will respond to damage caused by soil movement provided that it occurs as a result of a storm or flood event, but only where such damage arises within 72 hours of the event. The Applicant asserts that the damage may have arisen within the 72 hour period although because the tenants were away, it was not noticed immediately. It was reported to the FSP as soon as he became aware. However, the Applicant did not lodge his claim until 29 January 2012, more than 12 months after the January 2011 event and more than 2 months after the November event. Therefore, even if it were to be accepted that the weather events of 2011 could reasonably be considered to be a proximate or contributing factor to the damage arising, it now cannot be determined whether any damage arose within the initial 72 hours immediately post the storm/flood. The Panel therefore considers the Applicant has not brought his claim within the terms of the policy. The loss arose from causes specifically excluded from cover However, in any event the evidence supplied does not support the Applicant’s position that the damage arose from this event. Engineering firm “D” inspected the damaged building at the instruction of the Applicant. D concluded the damage had arisen as a result of foundation movement due to moisture changes in the reactive clay soils. Although D does make mention of the possibility that the extreme weather events of January 2011, may have contributed or hastened the loss, it is clear he attributed the proximate cause of the damage to the reactive soils and inadequate design and construction of the building. Case No: 339839 Determination Page 3 of 6 Engineering firm "R" were subsequently engaged by the Applicant and did not attribute the damage in any way to the storm/flood event. Rather, R considered the sole cause of the damage was the incorrect classification of the soils originally, which led to a method of construction utilised which was never going to be able to adequately withstand the variations in soil moisture content. R considered the failure of the slab was inevitable due to the manner in which it was constructed. Engineering firm "C" inspected the damage at the instruction of the FSP. C also concluded the damage had arisen as a result of variations in the soil moisture content principally due to the extremely reactive soils at the site, although it had been contributed to by inadequate drainage. Whilst C considered the weather events of 2011, may have contributed or hastened the damage occurring, it is clear C did not consider this a primary cause of the damage. The Panel accepts the three engineers are appropriately qualified and experienced to comment on this matter and in the absence of conflicting information; the FSP is entitled to rely on their findings. Whilst there are minor variations in the experts' opinions, all are in agreement that the dominant cause of the movement to the slab and footings is the extremely reactive soils at the site combined with inadequate slab design and construction methods to combat this. Whilst the problem may not have been evident prior to the January and November 2011 events, the Panel is not persuaded that these events precipitated the loss as much as merely highlighted an existing problem with the soils at the property, one that both R and C state was inevitably going to occur due to the method and manner of the home’s construction. The Panel also recognises established case law which provides that if there are two proximate causes of a loss where one is subject to cover and the other is not, an insurer is not liable for the claim as the excluded cause is dominant. As the policy specifically excludes loss or damage arising from any form of earth movement, the FSP has correctly declined the claim. 3 Supporting information 3.1 Expert evidence Record Key points Applicant's expert ( D ) Engineer 14 Feb 2012  since the significant rainfall and flood events of 2011 cracking has been identified to the house  the property is a brick veneer slab on ground and was constructed in 2005  the current owners purchased it in 2007 Case No: 339839 Determination Page 4 of 6  there is significant surface cracking in the walls, cornices, external concrete slabs and external brickwork  there is significant evidence of ground movement  as the initial identification of the cracking aligned with the period of extreme weather in January 2011, it is likely the problem has been initiated by this phenomena  the primary factors at play are likely to be a combination of the original subdivision earthworks inadequate and the rolled slab was not properly prepared  the re is poor drainage to the rainwater tank in the backyard  there is poor surface drainage of the runoff from the backyard  there are approximately 1 - 2 other allotments draining towards this one including tank drainage from neighbours  the infiltration of back yard and adjacent surface drainage has the potential to enter the subsurface of the slab and create significant differential ground movement  it is possible the footings and foundations were inadequately designed and poor workmanship has left the substructu re and superstructure with the inability to deal with the imposed loads Applicant's expert ( R ) Engineer 10 Sept 2012  geotechnical testing was undertaken including two test holes and two shallow pits were excavated and a floor level survey completed  the soil classification at the site is classified "E", which are extremely reactive soils  the original pre - construction classification was "P" for problem soils however no laboratory testing was conducted to quantify the predicted ground surface movement chara cteristics of the soil  the original classification is a significant misinterpretation of the site conditions  the soil is actually capable of differential ground movements in the order of 200% more than those predicted by the original engineer  in the absenc e of geotechnical laboratory testing it is not considered reasonable to have made appraisals or classifications as to how the 'ripped' soil will behave  in order to provide control for moisture related movement in the soil the screw in pier system was requi red to be anchored at depths which exceed the seasonal soil moisture variation  in addition the ground was require to have been effectively isolated from the underside of the footing and slab system  as the footing and slab system are out of level it is appa rent that the extremely reactive clay soils have heaved against the underside of the floor which has led to movement and caused structural failure  the cutting and filling at the site have resulted in the Case No: 339839 Determination Page 5 of 6 underlying stratum of weathered rock becoming relati vely shallow  therefore the depth of the screw in piers system was inadequate and are not adequately founded to provide appropriate anchorage to resist soil related movement effects  the site had been ripped but the soil was not scarified even remotely to t he standard which would have provided the required isolation to ground heave  the slab system is not capable of resisting future ground movement and damage will be ongoing unless significant stablisation measures are implemented  this type of footing and slab system including the site ripping is not deemed to comply with the standards and is an extremely unreliable method when dealing with soils of this nature  the slab system is considered to have failed as it can no longer perform in the intended manner  a ny issues of site drainage are considered to be of secondary importance compared to the failure to have adequately scarified ground surfaces  there is poor drainage along the right side of the house which encourages moisture absorption and retention  this is exacerbated by pavers along the front of the house which restricts drainage toward the street  the rear and side are poor drained and hold water, elevating soil moisture during periods of heavy rain  the driveway slabs have heaved upwards at the interfaces between the concrete footings and the pavement  there is evident leakage to ground from the rainwater tank and there is at least one downpipe broken  the building has moved up to 42mm out of alignment as the slab has pulled away from the screw in piers and t he soil beneath has heaved  ongoing movement would be expected to occur as soil moisture conditions beneath the slab vary  it may be more economical to replace the house on a conventionally designed very heavily stiffened slab  significant remedial works are required (and outlined) FSP's expert ( C ) Engineer 14 Feb 2012  minor to moderate degrees of damage was found to a number of areas of the property, including cracks in the ceiling, cornices, separation of skirting boards, and differential movement between intersecting walls  a floor level survey showed differential mov ement of up to 45mm  this is a clear indication that the residence has experienced movement due to subsidence within the foundation soils  a number of newly installed drainage sumps were visible to arrest drainage issues at the site, as previously during Case No: 339839 Determination Page 6 of 6 wea ther events the land would retain water like a 'swimming pool'  there were inadequate provisions made for drainage of storm water that ponds on the surface  inadequate measures were taken to prevent water entering into the foundation of the dwelling  there wa s a number of trees and other vegetation close to the dwelling which would affect the moisture condition of the soil and be another contributing factor for the movement of the building  there was moderate concrete cracking of 2 - 10mm in the driveway at rando m intervals  no drainage of any type was provided to divert storm water away from the driveway area and the control joints installed did not comply with the standard  the soil classification indicates the property was situated on extremely reactive soils wit h moisture changes  the soil under the footings has a high potential for shrink/swell and a large degree of surface movement due to changes in the soil moisture content would be expected  it is therefore inevitable that the underlying soils will swell and/or shrink  the significant rainfall in 2010/2011 has exacerbated movement of the footings due to excessive volume changes of the extremely reactive soils, causing damage to the building, however pre - existing movement had occurred prior to that period of time  the degree of movement has gradually increased over the past years until it reached the extent that it was noticeable  in addition to the primary cause of the damage being reactive soils, inadequate drainage, vegetation, failure of soil isolation and inadeq uate control joint have contributed to the damage  remedial measures were required 3.2 Relevant Legislation Wayne Tank and Pump Co Ltd v Employers Liability Assurance Corp Ltd [1974] QB 57.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.