Home / Financial Firm (Unknown - Insurer) / Determination 337582

Determination 337582

Swimming pool storm damage claim denied under hydrostatic pressure exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2014-03-25
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicants claimed for storm-related cracking of their swimming pool after heavy June 2013 rain, and the FSP denied the claim under the hydrostatic pressure exclusion. AFCA found the damage arose from run-off, an insured event, and ordered the FSP to indemnify the pool damage with interest if cash settled.

The insurer bears the onus of proving an exclusion applies, and it did not establish that hydrostatic pressure caused the damage rather than the covered storm run-off.

Issues

Subjects and remedies

home or building damagenatural disasterpay claimpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 337582 Determination Page 1 of 9 Case number: 337582 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim 18 March 2014 Summary Description  A claim under a home building and contents insurance policy following damage to the Applicants ‟ pool. Basis of Determination  A consideration of the evidence leading to the loss and the coverage provided by the policy. Determination  I determine the FSP is required to indemnify the Applicants for the damage to their swimming pool under the terms and conditions of the policy. Background 1. The Applicants held a home buildings and contents insurance policy with the FSP that was incepted on 19 January 2006 and renewed on a yearly basis. 2. On 13 July 2013, the Applicants noticed a vertical crack in one of the walls of their swimming pool and lodged a claim with the FSP. The Applicants were uncertain as to the exact cause of the damage but noted there had been significant continuous rainfall in the area during June 2013. 3. Following assessment of the damage by an engineer (B), the FSP denied the Applicants‟ claim on the basis that the damage was due to hydrostatic pressure which is not an insured event. 4. The Applicants disagree with the FSP‟s decision to deny the claim as th ey consider B‟s findings regarding the cause of the damage are unsubstantiated. Determination Case No: 337582 Determination Page 2 of 9 Summary of Applicants ’ position 5. The Applicants say the information relied upon by the FSP in making its decision to deny their claim is flawed. The Applicants disagree with B‟s opinion that the cause of the damage was hydrostatic pressure due to the hydrostatic relief valve not operating. 6. The Applicants maintain the damage to the pool was caused by large amounts of water run-off from the rear property during a storm event lasti ng a number of days. They note the pool has been installed for 28 years and has never required repair. They have had heavy rain before but not as continuous as the deluge experienced in June 2013. 7. The Applicants contend the pool was almost full of water when the crack first appeared. The male Applicant drilled holes into the crack in an effort to prevent it from worsening but water came in from behind and the crack moved further downwards toward the bottom of the pool. They note the pool has not moved out of the ground and remains in its original position. 8. The Applicants note the hydrostatic relief valve opened as it should when the water level reduced to around 500mm deep upon emptying. Furthermore, the valve was removed once the pool had emptied and was inspected by a pool equipment design engineer who found it to be in working order. 9. The Applicants maintain the hydrostatic valve would not have operated when the pool was full given the water weight would have equalled around 41,000 kilos and the pressure from the ground water would have had to exceed this for the valve to open. 10. The Applicants have provided a report from an independent engineer (C) , who also disagrees with B‟s findings given the pool was full with water when the crack first appeared. Additionally, the Applicants have provided other evidence to show how hydrostatic release valve functions in support of their view that B‟s opinion regarding the cause of the damage is flawed. 11. The male Applicant advises he is a hydraulics and pneumatics engineer who has been building award winning pools in the Sydney area for 25 years. He considers B‟s report is wrong regarding the fundamentals of hydrostatic pressure and hydraulic pressure. He notes B found the valve to be at fault, despite an inspection showing it to be operational and in good condition. 12. The Applicants also note B‟s inspection of the pool only lasted 10 minutes and despite being offered the opportunity to view the hydrostatic valve, B declined, which leads the Applicants to believe B had already made up his mind as to the cause of the damage beforehand. 13. The Applicants have issues with B‟s supplementary report , noting he indicated it was not possible to measure the amount of water around the pool without a standpipe, yet his own opinion was formed without doing so. Furthermore, the Applicants note B says the pool is located on the low side of the property, but this is not the case. Case No: 337582 Determination Page 3 of 9 14. The Applicants note the FSP has said in its notice of response it is not possible to determine the pressure required for the hydrostatic valve to operate, yet it maintains failure of the hydrostatic valve was the cause of the loss. Furthermore, the Applicants submit the pool did not move out of the ground at all, despite the FSP‟s contention it did. 15. The Applicants maintain the damage to their pool was not a consequence of hydrostatic pressure and consider the FSP should meet their claim on the basis the damage arose due to hydraulic pressure caused by substantial amounts of rainwater run-off, due to the insured event “Storm”. Summary of FSP’s position 16. The FSP maintains the Applicants have not established the damage to their pool arose as a consequence of an insured event and as such they are not liable for the claim. 17. The FSP relies upon the reports of B in support of its decision to deny the Applicants‟ claim. It submits the Applicant‟s pool was damaged as a result of hydrostatic pressure due to the failure of the hydrostatic release valve to operate. 18. The FSP notes hydrostatic pressure is not an event covered by the policy. Furthermore, the FSP submits hydrostatic pressure is excluded under the listed event of “Storm”. 19. The FSP refutes the Applicants‟ submission that B‟s report was flawed and contends the report of C was overly simplistic. It also questions the Applicant s‟ ability to calculate the pressure exerted from the outside of the pool without being able to measure the ground water level. 20. The FSP says the age of the hydrostatic valve is unknown but commonly such valves require replacement every five years. It notes the Applicants‟ advice that in 28 years the pool has never been drained nor had any works carried out for repair. 21. The FSP relies on the following policy provisions: “ Types of loss or damage your buildings are covered for We will cover your buildings against loss or damage caused by one or more of the insured events occurring during the period of insurance. We will also cover you for the other benefits listed below. Details of the terms, conditions and exclusions which specifically relate to each insured event and other benefits are provided on the pages indicated. Insured events 1. Accidental breakage 2. Earthquake 3. Explosion 4. Fire or smoke Case No: 337582 Determination Page 4 of 9 5. Impact damage 6. Lightning or thunderbolt 7. Malicious acts 8. Riot or civil commotion 9. Storm, rainwater or run-off 10. Theft, burglary or housebreaking 11. Water or other liquid damage .... 9. Storm, rainwater or run-off ... We will not pay for loss or damage: ... (c) caused by:  soil movement including erosion, landslide, mudslide or subsidence,  shrinkage or expansion of earth or land, or  hydros tatic pressure” Issue 22. Whether the FSP is required to indemnify the Applicants for the damage to their swimming pool under the terms and conditions of the policy. Reasons for decision 23. As advised to the parties, FOS has considered it appropriate to expedite the dispute in accordance with the Operational Guidelines to the FOS Terms of Reference. This dispute has not been the subject of a FOS Recommendation and has proceeded directly to Determination. 24. I am satisfied there has been a full exchange of material between the parties and each party has had the opportunity of clarifying the issues that arise from the material. 25. The Applicants have the onus of proving, on the balance of probabilities, they have suffered a loss caused by an insured event. If so proved, the FSP has to prove, on the balance of probabilities, the loss falls within an exclusion clause in the policy. 26. The Applicants submit the damage to their pool was the result of water run- off due to the insured event “Storm”. The FSP submits the damage to the Applicants‟ pool was the result of hydrostatic pressure which is not an event Case No: 337582 Determination Page 5 of 9 covered under the terms of the policy and excluded under “Storm” in any event. 27. Having considered the reports from the FSP‟s expert B and in particular the supplementary report, I am satisfied that the damage to the Applicants‟ pool followed a large continuous amount of rainfall for nine days where water was “cascading over (the Applicants‟) retaining walls and into the pool...” 28. The policy provides coverage for „Storm, rainwater or run - off‟. 29. Given the circumstances, I am satisfied that the Applicants have established that their loss arose from an insured event under the terms of the policy. 30. The policy provides an exclu sion for „hydrostatic pressure‟ and the FSP seeks to rely upon their exclusion to deny the Applicant‟s claim. 31. It is established insurance law that the FSP carries the onus to demonstrate that the policy exclusion of „hydrostatic pressure‟, applies to the circumstances of this case. 32. The FSP‟s decision to deny the Applicants‟ claim is based on two reports from engineer B, dated 26 July 2013 and 10 September 2013. I note B‟s second report was prepared in response to additional information provided by the Applicants, including the report of engineer C, dated 22 August 2013. 33. B provided the following conclusion in his first report: “The vertical cracking to the wall of the pool shell and bulging of the base in our opinion has been caused by hydrostatic pressure effects. Where there is an imbalance between the internal and external water pressure, the hydrostatic relief valve should activate and allow water to enter the pool. The fact that the hydrostatic relief valve did not initially activate in our view caused the resultant damage to the pool shell from external pressure generated by the build up of ground water.” 34. In response, the Applicants sought a report from engineer C. C‟s report dated 22 August 2013, states: “In my opinion the findings of B report that ultim ately a faulty hydrostatic relief valve was the reason of the damage are not accurate because, I have been informed by the owner that the pool was full of water when the crack occurred and in this case the hydrostatic relief valve would not and should not activate. The role of the hydrostatic relief valve is to activate and let the water inside the pool only when the pool is empty to prevent the pool from floating in the underground water and being pulled of the ground” (sic) 35. The male Applicant also calculated the pressure being exerted by the pool water at varying depths, noting the pool holds around 41,000 litres when full. He concluded there would be nowhere near enough pressure to activate the hydrostatic relief valve when the pool was filled to a level of 1.8m, as the external pressure would have needed to be greater than 17.66Kpa. He says this is supported by the fact that the valve did activate on emptying the pool when the water was approximately 500mm deep exerting pressure of around 4.9Kpa. Case No: 337582 Determination Page 6 of 9 36. In his report dated 10 September 2013, regarding the report of C, B states: “This statement is incorrect in that the pool doesn‟t need to be empty for the hydrostatic relief valve to operate. The hydrostatic relief valve is designed to activate when there is an imbalance between the internal and external water pressure irrespective of the water level within the pool. It is acknowledged that the likelihood of an imbalance in the internal and external water pressure is increased where the water level in the pool is lower than the normal operating level and particularly when the pool is emptied for maintenance purposes. The author having inspected numerous fibreglass pool structures previously has seen first hand where the hydrostatic relief valve has activated where there has been a large amount of water within the pool. The insured has alleged that the hydrostatic relief valve activated when there was approximately 500mm of water within the pool.” 37. In regard to the other evidence put forward by the Applicants, B stated:  Under the weather conditions reported by the Applicants, a substantial amount of groundwater would have accumulated around the base and walls of the pool.  The groundwater levels particularly around the walls of the pool cannot be determined unless a measurement is taken with a standpipe.  A high external water level around the walls of the pool would result in a substantial pressure beneath the base of the pool.  The external water pressure under the base of the pool in heavy rainfall conditions is complex and difficult to ascertain without a thorough geotechnical assessment.  The male Applicant‟s attempt at an analytical assessment to dispel the fact that the structural distress to the pool shell is flawed in that whilst the internal pressure exerted by the water in the pool can be calculated, the actual external water pressure beneath the base of the pool at the time of the incident cannot be determined.  Groundwater can exert significant pressure to the base of pools or other water retaining structures which can far exceed the internal pressure exerted by water.  The base of the pool bulged due to external water pressure exceeding the internal water pressure and the fibreglass shell was unable to cope with the localized stress due to the failure of the hydrostatic relief valve to activate.  The internal and external water pressure differential did not lift the pool out of the ground but was sufficient enough to damage the base.  The vertical cracking to the pool shell has been caused by external water pressure effects.  Under extreme rainfall conditions where the backfilled material is submerged in water, the sand material can be undermined and collapse. Without the sand backfill and the high water level to the pool walls, the external pressure can stress and crack the shell which has occurred in this instance. Case No: 337582 Determination Page 7 of 9  The male Applicant asserts the hydrostatic relief valve appeared to be in good condition, however, the reality is the hydrostatic relief valve did not activate when it was required to. Hydrostatic relief valves can be prone to malfunction and fail to open when required.  He has prepared numerous technical reports in relation to structural distress to fibreglass pool shells. Of all the pools that have been inspected, there is a common theme in that the structural distress to the pool shell whether it be bulging or cracking, occurred after heavy rainfall conditions and where the hydrostatic relief valve failed to activate. 38. My first reaction to the supplementary report from B, is that B on the one hand, ch allenges the Applicants‟ assessment on the basis that the actual external water pressure beneath the base of the pool at the time of the incident cannot be determined. 39. However and on the other hand, B concluded that the base of the pool bulged due to external water pressure exceeding the internal water pressure. 40. I do not understand how B could reach this conclusion, if the actual external water pressure beneath the base of the pool at the time of the incident, cannot be determined. 41. The Applicants have provided a number of documents explaining hydrostatic pressure. I note they all indicate the purpose of the hydrostatic relief valve is to equalise the pressure when the pool is being drained or is empty. 42. The Applicants have also provided a diagram showing how hydrostatic pressure is impacted by a changing water table. It notes when a pool is full of water it exerts a downward force due to gravity that is larger than that of the hydrostatic pressure exerted upwards by the water table. When the pool is emptied the force exerted downward is much less, so if the water table is high, the pressure exceeds that exerted by the weight of the pool, causing the pool to move out of the ground. 43. There is no dispute the pool was relatively full at the time the crack was first noticed. The information provided by the Applicants defining hydrostatic pressure, together with the male Applicant‟s calculations of the pressure that would have been required for hydrostatic pressure to be the cause of the damage, is supported by the report of C. 44. C considered the hydrostatic valve should not have opened when the pool was full given its role is to activate and let water into the pool only when the pool is empty, to prevent the pool from floating in underground water and being pulled from the ground. 45. Whilst I accept the pool does not need to be empty for the hydrostatic valve to operate as suggested by C, I am not persuaded on the evidence that the valve would have opened when the pool was full given the groundwater pressure would have needed to exceed that being exerted by the weight of the filled pool under gravity. I note the pool did not move out of the ground. Case No: 337582 Determination Page 8 of 9 46. The FSP have also failed to provide evidence in support of B‟s assertion that the hydrostatic valve was faulty. Whilst the Applicants have not provided a report from the pool equipment manufacturer who inspected the valve and found it to be operational, I have no reason to doubt this was the case. The valve clearly opened as it should when the water level dropped to around 500mm. I note B did not even undertake a visual inspection of the valve despite the Applicants providing him with the opportunity to do so. 47. There is no dispute there was a significant weather event in the Applicants‟ area in the month before the damage to the pool was discovered. In this regard, I note the rainfall data provided by the Applicants confirms 159mm of rain fell in June 2013. 48. I have no doubt the Applicants‟ property was inundated with water over a period of days during June 2013 and on balance I accept the excessive groundwater which resulted as a consequence , was responsible for the damage to the Applicants‟ pool. 49. Accordingly and as stated, I am satisfied that the Applicants have established the damage to the pool arose due to “run - off” which is an eve nt covered under the terms and conditions of the policy. 50. Also, as stated, the FSP carries the onus to establish that the evidence supports its position that the damage was caused by „hydrostatic pressure‟. 51. Having considered all of the available evidence, I note the following:  I am not satisfied that the FSP has established that there was a fault with the hydrostatic valve, or that the value failed to operate when B claims it should have;  I am concerned that B‟s challenge to the Applicants‟ submission and in deed B‟s own conclusions are based upon an assessment of the external water pressure, which B himself, maintains cannot be determined; and  I prefer the explanation and conclusions of the Applicants and their engineer C, as to the circumstances and cause of the Applicants‟ loss. 52. The result is that I am not satisfied that the FSP has established that the policy exclusion „hydrostatic pressure‟ applies to the circumstances of the Applicants ‟ loss. Determination 53. On the basis of the available information, I determine the FSP is required to indemnify the Applicants for the damage to their swimming pool, under the terms and conditions of the policy. Case No: 337582 Determination Page 9 of 9 54. I note the only quote for repairs has been provided by the Applicants. If the FSP does not accept the Applicants‟ quo te, it must obtain its own quote(s) within 30 days of the Applicants accepting this Determination. 55. If the parties cannot reach agreement as to the resolution of this matter, in accordance with this Determination, either party may refer the dispute back to the Service for further Determination. 56. If the FSP cash settles the Applicants‟ claim, then the FSP is to pay interest, in accordance with the Insurance Contracts Act 1984 , from the date of denial of the claim, until the date of settlement.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.