Home / Financial Firm (Unknown - Insurer) / Determination 331832
Determination 331832
Denial of claim
Summary
The applicant claimed for interior water damage from a June 2013 storm. The FSP denied the claim, and AFCA found the water entered through a deteriorated roof flue seal rather than an opening created by the storm.
Under the storm cover, rain entering the building is covered only if it entered through an opening created by the storm, and the seal failure was wear and tear.
Issues
- Claim denial primary · not upheld“As the claimed damage did not result from water entering the property through an opening created by a storm, it is not subject to cover under the policy.”
- Inadequate claim investigation secondary · not upheld“I do not consider that the reports of the FSP's contractors are inconsistent; they reflect interim steps in the investigative process.”
- Repairs or contractors secondary · upheld“M acted inappropriately in failing to obtain the Applicant's consent before carrying out the repairs.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Case No: 331832 Determination Page 1 of 7
Case number: 331832
General Insurance - Domestic Insurance - Home Building - FSP Decision -
Denial of claim
26 March 2014
Summary
Description
This dispute involves a claim by the Applicant under a home building
insurance policy issued by the Financial Services Provider (FSP) for water
damage to his home during a storm. The FSP denied the Applicant’s claim
on the basis that the damage was not caused by the storm or any other
event insured under the policy, but was due to wear and tear.
Basis of Determination
On the basis of the available information, the damage to the Applicant’s
home was caused by the deterioration of a seal around the flue on the roof
which allowed water to enter the property during the storm. The
Applicant’s policy only provides cover for damage caused by water
entering during a storm where the water has entered through an opening
created by the storm. Accordingly, the claimed damage did not fall within
the scope of cover under the policy.
Determination
The FSP is entitled to deny the Applicant’s claim.
Summary of Applicant’s position
1. The Applicant says that the interior of his home sustained damage when
water entered the lounge during very heavy rain falls on 21 and 22 June
2013 (with over 20.2 millimetres of rain recorded during this two day period).
2. The Applicant says that:
the various contractors engaged by the FSP to inspect the property
were unable to agree on the cause of the water entry;
the reports relied on by the FSP contain a number of errors and
therefore it is unfair for the FSP to rely on them; and
Determination
Case No: 331832 Determination Page 2 of 7
the plumber appointed by the FSP carried out repairs to the property,
which prevented him from arranging for his own plumber to examine
the roof of the property to determine the cause of the water entry.
Summary of FSP’s position
3. The FSP says that the Applicant’s policy only provides cover for water
entering the property during a storm in circumstances where the water has
entered through an opening caused by the storm.
4. The FSP relies o n the report of its builder (“C”) and plumber (“ M ”) in support
of its position that the cause of the water entry to the Applicant’s home was
the deterioration of a Dektite seal around the flue on the roof. Accordingly,
the FSP says that it is entitled to deny the Applicant’s claim on the basis that
the claimed damage:
was not subject to cover under the insured event of storm, as it was not
caused by water entering through an opening created by the storm;
and/or
was excluded from cover under the general policy exclusion for wear
and tear and deterioration.
5. The FSP acknowledges that there were factua l errors in the report provided
by its builder (C). However, the FSP says that these errors do not impact on
its decision to deny the claim.
6. The FSP also acknowledges that its plumber (M) failed to obtain the
Applicant’s consent to repair the Dektite seal, but says that M acted
reasonably in this regard, by carrying out the repairs at no cost to the
Applicant, in order to prevent any further damage.
Issue
7. Whether the FSP is entitled to deny the Applicant’s claim.
Reasons for decision
8. I am satisfied that there has been an exchange of material information
between the parties and that each party has had an opportunity to comment
on the issues raised by the other.
9. It is an accepted principle of general insurance law that an insured bears the
onus of establishing that, on the balance of probabilities, they have suffered
a loss caused by a risk insured under the policy. This is known as a prima
facie claim. If the insured is able to establish a prima facie claim, the onus
then shifts to the insurer to show that, on the balance of probabilities, the
Case No: 331832 Determination Page 3 of 7
loss falls within an exclusion clause under the policy or that it is otherwise
entitled to deny liability.
10. Accordingly, as the Applicant brought the claim under the policy, he bears
the onus of establishing that the damage to his house was caused by a risk
insured under the policy (in this case, the storm in June 2013).
Terms of policy
11. The Applicant’s policy is a defined events policy, which provides cover for
loss or damage caused by certain specified insured events, including the
insured event of “Storm”, subject to the conditions and exclusions set out in
the policy.
12. The policy provides for the insured event of storm on the following terms:
“ Storm
What is Covered?
Loss or damage to the insured property caused by storm, lightning,
wind and storm water overflow from roof gutters and their downpipes
or from the area immediately around the premises.
...
What is not Covered?
Any loss, damage or legal liability caused by:
…
• rain, wind or any item entering the building
unless it entered through an opening created
by the storm; ”
13. The cover provided under this insured event is also subject to the general
exclusion under the policy for loss or damage to property caused directly or
indirectly by “wear and tear, rust, corrosion or deterioration”.
Available information
14. The FSP’s claims notes reflect that, when the Applicant lodged his claim on
22 June 2013, he reported water under the floating floor boards in the area
of the fireplace. He commented that the water appeared to have come
through the fireplace and may have originally entered via the roof.
15. After the Applicant lodged his claim, the FSP arranged for its assessor (“TE” )
to attend the property and inspect the damage. TE attended the property on
25 June 2013 and reported that:
damage to the gas heater, floating floor and surrounding skirting boards
in the lounge/dining room had occurred as a result of water entering the
wall cavity and/or the chimney during the storm. The gas heater was
starting to rust;
Case No: 331832 Determination Page 4 of 7
the roof was colourbond with a valley gutter directly above the area
suggesting a possible bank up of rainwater. There was also a flue
above the area that appeared to be slightly “off angle” possibly as a
result of having moved during the storm;
the property was in immaculate condition and very well maintained. The
Applicant had advised that there had not been any similar problems
with water entry previously; and
based on his inspection and the information supplied by the Applicant,
it appeared the Applicant had submitted a genuine claim for storm
damage. However, this needed to be confirmed by the builder who had
been appointed to report on the damage.
16. The FSP’s builder ( C) inspected the property on 26 June 2013 but was
unable to determine the cause of the damage. As there was pipe work
running down the chimney cavity, C considered that this might have been
the cause of the water entry and arranged for a plumber to attend the site.
17. The plumber (M) attended the property on 1 July 2013 (together with C). In
his report dated 2 July 2013, C stated that:
the roof was in good condition and did not require any maintenance;
further investigations in the roof cavity showed water staining to the
back edge of the heater flue and rusting to the fire box; and
a roof inspection revealed the Dektite seal had failed under the silicone
sealant which had caused liquid to escape into the roof cavity and run
down the heater flue, into the gas heater and onto the floor below. This
was the cause of the claimed damage.
18. The FSP has also provided a copy of an undated report from the plumber
(M) which states that:
his inspection of the log fire revealed corrosion on the steel cabinet and
the rear of the flueing which was dry. This suggested that the leak was
not constant (as would be the case if there was a leaking water pipe);
when he entered the roof cavity and inspected the flueing for the gas
heater in the lounge, he found water marks down the rear of the flueing;
when he gained access to the outside of the roof and inspected the
Dektite seal around the flue, he found that when weight was applied to
the roof sheet, a crack in the silicone appeared, due to the breakdown
of the silicone seal; and
he had resealed the Dektite seal with roof and gutter silicone at no
expense to the Applicant.
19. During the course of this dispute, the Applicant raised concerns that the
damage to his property could have been caused by water entering through
the roof, rather than because of the failed Dektite seal.
Case No: 331832 Determination Page 5 of 7
20. The FSP communicated these concerns to the builder (C), who provided a
further report dated 3 December 2013 in which he confirmed that, at the time
of his inspection:
there was no evidence of water staining to the walls or ceiling, which
would be expected if water had entered through the roof; and
he had not found any water damage to the ceiling insulation when he
inspected the roof cavity.
21. In his further report, C also confirmed that when he attended the property
with M they found that, when the top side of the Dektite seal was subjected
to weight, it was apparent that the seal had not adhered correctly. This had
allowed water to pool on the roof, enter into the roof cavity and then run
down the heater flue and onto the heater and floor below.
Analysis
22. I have carefully reviewed the information provided by the parties in relation to
the cause of damage, including the various reports provided by the FSP’s
contractors. In summary, I consider that the findings of the contractors were
as follows:
the assessor (TE) confirmed that the damage to the property had been
caused by water entering during the storm. However, he did not
express a view as to the cause of the water entry and appointed a
builder (C) to assess this;
the builder (C) confirmed that the roof did not appear to be leaking but
was otherwise unable to determine the cause of the water entry. He
noted water pipes, which he thought might provide a possible
explanation; and
the plumber (M) determined that the cause of the water entry was the
deterioration of the Dektite seal around the flue on the roof, which had
allowed water to enter during the storm.
23. The Applicant says that the FSP’s contractors were unable to agree on the
cause of the damage.
24. In my view, while TE and C expressed preliminary views about the possible
cause of the damage, neither reached a definitive view and both considered
that it was necessary to appoint another contractor to undertake further
investigations. As a result of these further investigations, it was confirmed
(by C) that the cause of the damage was not the roof and (by M) that the
cause of damage was not the pipes identified by C (as these were gas pipes,
not water pipes). It was not until M identified the issue with the Dektite seal
that the cause of the damage was finally determined.
25. Accordingly, I do not consider that the reports of the FSP’s contractors are
inconsistent – rather, they are reflective of interim steps in the investigative
process undertaken by the FSP. In my view, the FSP acted appropriately in
Case No: 331832 Determination Page 6 of 7
arranging for additional contractors to inspect the property when the cause of
damage could not initially be determined.
26. I am satisfied that M’s findings (as supported by CS’s report) provide a
logical and reasonable expl anation as to the cause of the water entry. C’s
report confirms that the roof was generally in good condition. Further, there
is no information to suggest that the water entered through any other means.
27. Under the terms of the Applicant’s policy (as set out in paragraph 12 above),
no cover is provided for damage caused by rain entering the property unless
the rain enters through “an opening created by the storm”.
28. In his submissions, the Applicant says that the damage to the Dektite seal
was not caused by wear and tear, but was due to the ferocity of the rain
hitting the seal during the storm.
29. Given the nature of the damage identified by M (being the deterioration
and/or lack of adhesion of the sealant), I consider that this is more likely to
have occurred gradually as a result of deterioration over a long period of
time, rather than as the result of the storm on 21 and 22 June 2013. Further,
I note that the FSP’s contractors identified rust to the fireplace, which is more
consistent with water having entered over a period of time.
30. Accordingly, I consider that, on the balance of probabilities, the failure of the
Dektite seal occurred due to wear and tear and/or gradual deterioration,
rather than as a result of the storm on June 2013. As the claimed damage
did not result from water entering the property through an opening created
by a storm, it is not subject to cover under the policy.
31. In relation to the other issues raised by the Applicant, I note that:
the Applicant has identified factual errors in C’s report. In particular, the
report states that the plumber (M) carried out an electronic audio and
pressure test to determine whether there was a burst pipe and that the
Applicant had paid M for the repairs to the Dektite seal. However, the
FSP has clarifie d that the tests referred to in C’s report were not carried
out because the relevant pipe was a gas pipe and not a water pipe.
While the errors in C’s report are disappointing, I am satisfied that the
nature of the errors are such that they do not have the effect of altering
my findings as to the cause of the water damage to the Applicant’s
property;
the Applicant says that C and M did not carry out a pressure test on the
Dektite seal as they did not take any hoses onto the roof. However, in
my view, it is clear from the reports provided by C and M that the
“pressure” test to which they have referred involved putting weight on
the seal, rather than applying water pressure. I am satisfied that the
pressure test carried out would have been sufficient to reveal a gap in
the silicone sealant, as identified by C and M in their reports; and
the Applicant says that the repairs to the Dektite seal carried out by M
without his consent prevented his plumber from determining the cause
Case No: 331832 Determination Page 7 of 7
of the water entry (including, if relevant, the reason why the Dektite seal
failed). The FSP has acknowledged that M should have sought the
Applicant’s permission before undertaking repairs, but says that he
carried out the repairs in good faith at no cost to the Applicant, in order
to prevent further damage. I consider that M acted inappropriately in
failing to obtain the Applicant’s consent before carrying out the repairs.
I also accept that this has limited the Applicant’s ability to obtain an
independent expert opinion as to the cause of the damage. However,
given the nature of the issues with the Dektite seal and the limited
scope of cover provided under the policy for water entry, I am satisfied
that M’s actions have not prejudiced the outcome of the Applicant’s
claim.
32. For the reasons outlined above, I consider that the FSP is entitled to deny
the Applicant’s claim.
Determination
33. On the basis of the available information I determine that the FSP is entitled
to deny the Applicant’s claim.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.