Home / Financial Firm (Unknown - Insurer) / Determination 331832

Determination 331832

Denial of claim

FirmFinancial Firm (Unknown - Insurer)
Decided2014-03-27
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed for interior water damage from a June 2013 storm. The FSP denied the claim, and AFCA found the water entered through a deteriorated roof flue seal rather than an opening created by the storm.

Under the storm cover, rain entering the building is covered only if it entered through an opening created by the storm, and the seal failure was wear and tear.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 331832 Determination Page 1 of 7 Case number: 331832 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim 26 March 2014 Summary Description  This dispute involves a claim by the Applicant under a home building insurance policy issued by the Financial Services Provider (FSP) for water damage to his home during a storm. The FSP denied the Applicant’s claim on the basis that the damage was not caused by the storm or any other event insured under the policy, but was due to wear and tear. Basis of Determination  On the basis of the available information, the damage to the Applicant’s home was caused by the deterioration of a seal around the flue on the roof which allowed water to enter the property during the storm. The Applicant’s policy only provides cover for damage caused by water entering during a storm where the water has entered through an opening created by the storm. Accordingly, the claimed damage did not fall within the scope of cover under the policy. Determination  The FSP is entitled to deny the Applicant’s claim. Summary of Applicant’s position 1. The Applicant says that the interior of his home sustained damage when water entered the lounge during very heavy rain falls on 21 and 22 June 2013 (with over 20.2 millimetres of rain recorded during this two day period). 2. The Applicant says that:  the various contractors engaged by the FSP to inspect the property were unable to agree on the cause of the water entry;  the reports relied on by the FSP contain a number of errors and therefore it is unfair for the FSP to rely on them; and Determination Case No: 331832 Determination Page 2 of 7  the plumber appointed by the FSP carried out repairs to the property, which prevented him from arranging for his own plumber to examine the roof of the property to determine the cause of the water entry. Summary of FSP’s position 3. The FSP says that the Applicant’s policy only provides cover for water entering the property during a storm in circumstances where the water has entered through an opening caused by the storm. 4. The FSP relies o n the report of its builder (“C”) and plumber (“ M ”) in support of its position that the cause of the water entry to the Applicant’s home was the deterioration of a Dektite seal around the flue on the roof. Accordingly, the FSP says that it is entitled to deny the Applicant’s claim on the basis that the claimed damage:  was not subject to cover under the insured event of storm, as it was not caused by water entering through an opening created by the storm; and/or  was excluded from cover under the general policy exclusion for wear and tear and deterioration. 5. The FSP acknowledges that there were factua l errors in the report provided by its builder (C). However, the FSP says that these errors do not impact on its decision to deny the claim. 6. The FSP also acknowledges that its plumber (M) failed to obtain the Applicant’s consent to repair the Dektite seal, but says that M acted reasonably in this regard, by carrying out the repairs at no cost to the Applicant, in order to prevent any further damage. Issue 7. Whether the FSP is entitled to deny the Applicant’s claim. Reasons for decision 8. I am satisfied that there has been an exchange of material information between the parties and that each party has had an opportunity to comment on the issues raised by the other. 9. It is an accepted principle of general insurance law that an insured bears the onus of establishing that, on the balance of probabilities, they have suffered a loss caused by a risk insured under the policy. This is known as a prima facie claim. If the insured is able to establish a prima facie claim, the onus then shifts to the insurer to show that, on the balance of probabilities, the Case No: 331832 Determination Page 3 of 7 loss falls within an exclusion clause under the policy or that it is otherwise entitled to deny liability. 10. Accordingly, as the Applicant brought the claim under the policy, he bears the onus of establishing that the damage to his house was caused by a risk insured under the policy (in this case, the storm in June 2013). Terms of policy 11. The Applicant’s policy is a defined events policy, which provides cover for loss or damage caused by certain specified insured events, including the insured event of “Storm”, subject to the conditions and exclusions set out in the policy. 12. The policy provides for the insured event of storm on the following terms: “ Storm What is Covered? Loss or damage to the insured property caused by storm, lightning, wind and storm water overflow from roof gutters and their downpipes or from the area immediately around the premises. ... What is not Covered? Any loss, damage or legal liability caused by: … • rain, wind or any item entering the building unless it entered through an opening created by the storm; ” 13. The cover provided under this insured event is also subject to the general exclusion under the policy for loss or damage to property caused directly or indirectly by “wear and tear, rust, corrosion or deterioration”. Available information 14. The FSP’s claims notes reflect that, when the Applicant lodged his claim on 22 June 2013, he reported water under the floating floor boards in the area of the fireplace. He commented that the water appeared to have come through the fireplace and may have originally entered via the roof. 15. After the Applicant lodged his claim, the FSP arranged for its assessor (“TE” ) to attend the property and inspect the damage. TE attended the property on 25 June 2013 and reported that:  damage to the gas heater, floating floor and surrounding skirting boards in the lounge/dining room had occurred as a result of water entering the wall cavity and/or the chimney during the storm. The gas heater was starting to rust; Case No: 331832 Determination Page 4 of 7  the roof was colourbond with a valley gutter directly above the area suggesting a possible bank up of rainwater. There was also a flue above the area that appeared to be slightly “off angle” possibly as a result of having moved during the storm;  the property was in immaculate condition and very well maintained. The Applicant had advised that there had not been any similar problems with water entry previously; and  based on his inspection and the information supplied by the Applicant, it appeared the Applicant had submitted a genuine claim for storm damage. However, this needed to be confirmed by the builder who had been appointed to report on the damage. 16. The FSP’s builder ( C) inspected the property on 26 June 2013 but was unable to determine the cause of the damage. As there was pipe work running down the chimney cavity, C considered that this might have been the cause of the water entry and arranged for a plumber to attend the site. 17. The plumber (M) attended the property on 1 July 2013 (together with C). In his report dated 2 July 2013, C stated that:  the roof was in good condition and did not require any maintenance;  further investigations in the roof cavity showed water staining to the back edge of the heater flue and rusting to the fire box; and  a roof inspection revealed the Dektite seal had failed under the silicone sealant which had caused liquid to escape into the roof cavity and run down the heater flue, into the gas heater and onto the floor below. This was the cause of the claimed damage. 18. The FSP has also provided a copy of an undated report from the plumber (M) which states that:  his inspection of the log fire revealed corrosion on the steel cabinet and the rear of the flueing which was dry. This suggested that the leak was not constant (as would be the case if there was a leaking water pipe);  when he entered the roof cavity and inspected the flueing for the gas heater in the lounge, he found water marks down the rear of the flueing;  when he gained access to the outside of the roof and inspected the Dektite seal around the flue, he found that when weight was applied to the roof sheet, a crack in the silicone appeared, due to the breakdown of the silicone seal; and  he had resealed the Dektite seal with roof and gutter silicone at no expense to the Applicant. 19. During the course of this dispute, the Applicant raised concerns that the damage to his property could have been caused by water entering through the roof, rather than because of the failed Dektite seal. Case No: 331832 Determination Page 5 of 7 20. The FSP communicated these concerns to the builder (C), who provided a further report dated 3 December 2013 in which he confirmed that, at the time of his inspection:  there was no evidence of water staining to the walls or ceiling, which would be expected if water had entered through the roof; and  he had not found any water damage to the ceiling insulation when he inspected the roof cavity. 21. In his further report, C also confirmed that when he attended the property with M they found that, when the top side of the Dektite seal was subjected to weight, it was apparent that the seal had not adhered correctly. This had allowed water to pool on the roof, enter into the roof cavity and then run down the heater flue and onto the heater and floor below. Analysis 22. I have carefully reviewed the information provided by the parties in relation to the cause of damage, including the various reports provided by the FSP’s contractors. In summary, I consider that the findings of the contractors were as follows:  the assessor (TE) confirmed that the damage to the property had been caused by water entering during the storm. However, he did not express a view as to the cause of the water entry and appointed a builder (C) to assess this;  the builder (C) confirmed that the roof did not appear to be leaking but was otherwise unable to determine the cause of the water entry. He noted water pipes, which he thought might provide a possible explanation; and  the plumber (M) determined that the cause of the water entry was the deterioration of the Dektite seal around the flue on the roof, which had allowed water to enter during the storm. 23. The Applicant says that the FSP’s contractors were unable to agree on the cause of the damage. 24. In my view, while TE and C expressed preliminary views about the possible cause of the damage, neither reached a definitive view and both considered that it was necessary to appoint another contractor to undertake further investigations. As a result of these further investigations, it was confirmed (by C) that the cause of the damage was not the roof and (by M) that the cause of damage was not the pipes identified by C (as these were gas pipes, not water pipes). It was not until M identified the issue with the Dektite seal that the cause of the damage was finally determined. 25. Accordingly, I do not consider that the reports of the FSP’s contractors are inconsistent – rather, they are reflective of interim steps in the investigative process undertaken by the FSP. In my view, the FSP acted appropriately in Case No: 331832 Determination Page 6 of 7 arranging for additional contractors to inspect the property when the cause of damage could not initially be determined. 26. I am satisfied that M’s findings (as supported by CS’s report) provide a logical and reasonable expl anation as to the cause of the water entry. C’s report confirms that the roof was generally in good condition. Further, there is no information to suggest that the water entered through any other means. 27. Under the terms of the Applicant’s policy (as set out in paragraph 12 above), no cover is provided for damage caused by rain entering the property unless the rain enters through “an opening created by the storm”. 28. In his submissions, the Applicant says that the damage to the Dektite seal was not caused by wear and tear, but was due to the ferocity of the rain hitting the seal during the storm. 29. Given the nature of the damage identified by M (being the deterioration and/or lack of adhesion of the sealant), I consider that this is more likely to have occurred gradually as a result of deterioration over a long period of time, rather than as the result of the storm on 21 and 22 June 2013. Further, I note that the FSP’s contractors identified rust to the fireplace, which is more consistent with water having entered over a period of time. 30. Accordingly, I consider that, on the balance of probabilities, the failure of the Dektite seal occurred due to wear and tear and/or gradual deterioration, rather than as a result of the storm on June 2013. As the claimed damage did not result from water entering the property through an opening created by a storm, it is not subject to cover under the policy. 31. In relation to the other issues raised by the Applicant, I note that:  the Applicant has identified factual errors in C’s report. In particular, the report states that the plumber (M) carried out an electronic audio and pressure test to determine whether there was a burst pipe and that the Applicant had paid M for the repairs to the Dektite seal. However, the FSP has clarifie d that the tests referred to in C’s report were not carried out because the relevant pipe was a gas pipe and not a water pipe. While the errors in C’s report are disappointing, I am satisfied that the nature of the errors are such that they do not have the effect of altering my findings as to the cause of the water damage to the Applicant’s property;  the Applicant says that C and M did not carry out a pressure test on the Dektite seal as they did not take any hoses onto the roof. However, in my view, it is clear from the reports provided by C and M that the “pressure” test to which they have referred involved putting weight on the seal, rather than applying water pressure. I am satisfied that the pressure test carried out would have been sufficient to reveal a gap in the silicone sealant, as identified by C and M in their reports; and  the Applicant says that the repairs to the Dektite seal carried out by M without his consent prevented his plumber from determining the cause Case No: 331832 Determination Page 7 of 7 of the water entry (including, if relevant, the reason why the Dektite seal failed). The FSP has acknowledged that M should have sought the Applicant’s permission before undertaking repairs, but says that he carried out the repairs in good faith at no cost to the Applicant, in order to prevent further damage. I consider that M acted inappropriately in failing to obtain the Applicant’s consent before carrying out the repairs. I also accept that this has limited the Applicant’s ability to obtain an independent expert opinion as to the cause of the damage. However, given the nature of the issues with the Dektite seal and the limited scope of cover provided under the policy for water entry, I am satisfied that M’s actions have not prejudiced the outcome of the Applicant’s claim. 32. For the reasons outlined above, I consider that the FSP is entitled to deny the Applicant’s claim. Determination 33. On the basis of the available information I determine that the FSP is entitled to deny the Applicant’s claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.