Home / Financial Firm (Unknown - Insurer) / Determination 331787

Determination 331787

Claim denied under general exclusions for water seepage, inherent defects and gradual deterioration

FirmFinancial Firm (Unknown - Insurer)
Decided2014-07-11
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed under a home and contents policy for rot to her balcony caused by water entering over a long period. The FSP denied the claim relying on exclusions for water seepage, defects and gradual deterioration, and AFCA found the FSP entitled to deny liability.

Water seepage over an extended period and gradual deterioration fell within the policy exclusions, and section 46 of the Insurance Contracts Act did not invalidate them because they have no temporal aspect.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 331787 Determination Page 1 of 4 Case number: 331787 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim - Policy Exclusion 4 July 2014 Summary Description:  The claim arises under a Home and Contents Insurance Policy following water related damage sustained to the balcony of the Applicant‟s home.  The FSP has denied liability relying upon exclusions contained within the policy. Basis for Determination:  The Applicant‟s policy is an accidental loss and damage policy including specified events. There is no dispute that the damage identified at the property was accidental damage.  The FSP has obtained reports from three specialists that identify most likely the cause of damage was the gradual deterioration of the timber d ue to water entering through inadequate water proofing of the vertical face.  The opinions provided by the FSP‟s experts , supported by the latest opinion offered by the Applicant‟s builder , identified water had been entering through the fascia flashing allowing the gradual deterioration of the fascia beam and floor joists.  The evidence considered as a whole establishes that the damage was most likely due to inherent defects, structural defec ts, faulty workmanship or faulty design or wear and tear or gradual deterioration. Determination:  The FSP is entitled to deny liability for the Applicant ‟s claim in accordance with the terms and conditions of the policy. Determination Case No: 331787 Determination Page 2 of 4 Background 1. The Applicant lodged a claim under her home and contents insurance policy after identifying damage to her balcony in March 2013. 2. The balcony had suffered rot due to water penetration and required demolition. 3. Following investigation of the claim, the FSP has declined the claim relying upon exclusions contained within the terms of the policy including: a) Damage caused by water seeping through a wall or floor; b) Damage caused by inherent defects, structural defects, faulty workmanship or faulty design; or c) Damage caused by wear, tear, rust, corrosion, depreciation or gradual deterioration. 4. The Applicant disputes the FSP‟s position and maintains that many insurers pay claims that involve gradual deterioration and for various reasons. The Applicant believes that as she had no way of identifying the damage and as the balcony was not structurally defective, then the FSP should meet its liability under the terms of the policy. Conclusions in Recommendation 6. This matter has been subject to a Recommendation which was issued by the Service on 22 January 2014. A copy of the Recommendation is attached. 7. It was the Case Manager‟s Recommendation that the FSP be entitled to deny indemnity for the Applicant‟s claim. 8. The Applicant has rejected the Recommendation. Further submissions 9. Following rejection of the Recommendation, the Applicant has provided a further report from her builder. 10. The Applicant maintains that in the opinion of her builder Z supported by the findings of the FSP‟s consultant HC , the water entered through the vertical fascia beam of the balcony. 11. There were no structural defects in the building of the balcony, however Z concedes that the overlapping flashing seal has deteriorated over time which has allowed the water to enter. Case No: 331787 Determination Page 3 of 4 12. The Applicant has also supplied particulars from the Council relating to the building inspection and occupancy permits. Based on the information provided the building was structurally sound and did not contain faulty workmanship, faulty design or inherent defects. 13. In response to the Applicant‟s further submissions, the FSP maintains that there is no dispute that the damage to the balcony was not the result of strong winds or storm but due to water entering the balcony over a long period of time, resulting in long term rotting and deterioration of the timber framing members and its surroundings. 14. The FSP relies on the general exclusions contained within the policy and in particular that the damage was due to water seeping through a wall or floor, or caused by inherent defects, structural defects, faulty workmanship or faulty design or by wear, tear, rust corrosion, depreciation or gradual deterioration. 15. Insofar as Section 46 of the Insurance Contracts Act may apply, the FSP maintains it has no application as the exclusions could not be said to be made by reference to a condition of a thing at a time the contract was entered into. Ombudsman’s consideration 16. I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties, both before and after the Recommendation. I am satisfied that the documentation I have relied on has been provided to both parties. 17. I have carefully co nsidered the case manager‟s Recommendation, and I am satisfied that it contains an accurate summary of the background to this dispute, the parties‟ positions, the issues to be determined, any applicable paragraphs of the Terms of Reference and any relevant law. 18. In considering Section 46 of the Act, the Recommendation correctly identifies that an insurer is entitled to exclude cover for particular events irrespective of when they occur. 19. Unless the exclusion is made by reference to the condition of a thing at the time the contract was entered into, the FSP is entitled to rely upon the exclusion. It cannot be said that the general exclusions insofar as they relate to wear and tear or depreciation, inherent defects etc operate by reference to a condition of the balcony at the time the contract was entered into. 20. I note that the Applicant accepts this aspect of the Determination. 21. I am satisfied having looked at the further submissions made by the Applicant that the property was inspected and that following the inspection prior to the occupancy certificate being issued, there were no obvious Case No: 331787 Determination Page 4 of 4 structural defects or faulty workmanship. At the time the building was completed, it was most likely structurally sound and water tight. 22. The evidence however and in particular the evidence from the Applicant‟s own builder is that due to a deterioration over time of the vertical flashing , the ingress of water was allowed and was absorbed into the timber. This transferred to the floor joists allowing gradual breakdown of the fascia beam and floor joists to the point of eventual collapse. 23. Whilst I accept the Applicant had no way of knowing this was occurring or the stage that it had reached, I am satisfied that the evidence of all of the experts including the Applicant‟s builder su pports a finding that the damage to the balcony was caused by the gradual deterioration of the fascia beam and floor joists. 24. I have considered the further submissions and information exchanged in this matter. I agree with the Case Manager‟s Recommendation and am satisfied that the FSP has established on the balance of probabilities the application of the relevant exclusions contained within the terms of the policy. Determination 25. I determine that the FSP is entitled rely upon the terms and conditions of the policy to deny liability for the Applicant‟s claim. Case No: 331787 Recommendation Page 1 of 6 Case number: 331787 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim - Policy Exclusion 22 January 2014 Background 1. The Applicant held a home and contents insurance policy with the Financial Services Provider (FSP) which was current at the time of the loss. 2. On 25 March 2013, the Applicant lodged a claim for storm damage sustained to the balcony of her home. 3. As part of the FSP‟s claims assessment process, a loss adjuster (CC), a builder (JL) and an engineer (HC) were appointed to report on the damage claimed. 4. Upon receipt of their reports, the FSP denied indemnity for the claim on the basis the damage was not attributable to a single storm event but had been occurring as a result of water ingress into the balcony over an extended period of time and thereby excluded under the policy. 5. The Applicant disagrees with the FSP‟s decision and expects it to honour the claim. Summary of Applicant’s position 6. I note the Applicant has a nominated representative in relation to this dispute. For the purposes of this Recommendation, any reference to the Applicant includes her representative. 7. The Applicant submits the damage was caused by storm/rainwater which is covered under the policy. Further, she could not reasonably have been aware of the damage and therefore the FSP should honour the spirit of section 46 of the Insurance Contracts Act 1984 (the Act). Recommendation Case No: 331787 Recommendation Page 2 of 6 Summary of FSP’s position 8. The FSP relies upon the reports by CC, JL and HC in establishing the damage was a result of water ingress into the balcony over an extended period of time which is excluded from cover under the policy. Issue 9. Whether the FSP was entitled to deny indemnity for the Applicant‟s claim. Reasons for Recommendation 10. I am satisfied there has been a full exchange of material between the parties and each party has had the opportunity of clarifying the issues that arise from the material. 11. I have reviewed the submissions of the parties in relation to the terms and conditions of the policy and will only refer to the relevant s ubmissions and materials raised. 12. The onus is on the Applicant to establish, on the balance of probabilities, they have suffered a loss caused by a risk insured against under the policy. This is known as a prima facie claim. If such a claim is established, the onus shifts to the FSP to show, on the balance of probabilities, the claim falls within an exclusion under the policy. 13. I note (in addition to specified events) the policy provides cover for accidental damage sustained to the Applicant‟s home. There i s no dispute between the parties the balcony at the home has suffered physical damage. I am therefore satisfied the Applicant has established a prima facie claim. 14. The onus therefore shifts to the FSP to show on balance the claim falls within an exclusion under the policy. 15. In denying the claim, the FSP relies upon the damage assessment reports provided by CC, JL and HC who state: CC‟s report dated 12 April 2013  there was extensive rot to the timbers beneath the sheeting and fascia boards which appeared to have been caused by ongoing seepage via the balcony tiling; and  the damage would have been occurring unbeknownst to the Applicant as no external damage would have been noted to the external facade of the balcony; JL‟s report dated 23 April 2013 Case No: 331787 Recommendation Page 3 of 6  in his expert opinion, the damage as presented was not a result of the claimed storm event or any other storm event;  the damage was due to inadequate or no waterproofing membrane and subsequent failures have proven catastrophic to the balcony; and  the rotten hardwood timber would have taken many years to be in such an advanced deteriorated state and evident to the southern end of the balcony including the face beam. HC‟s report dated 30 May 2013  the rotting and collapse of the soffit lining sheets and floor framing members to the second floor balcony area are typical of problems that occur due to inadequate water proofing of the vertical face and the junction of the balcony. This has allowed water to enter the area and resulted in rotting and deterioration of the timber beams;  the rotting and deterioration is occurring at the southern end which is exposed to more of the weather than the northern end;  some problems were evident with the northern end which would indicate water is also entering into this area and into the timber floor framing members;  rotting and deterioration of timber does not occur in one isolated storm but occurs over a long period of time. Therefore, it would appear the water has been entering inside the balcony for some time due to the extent of rotting and deterioration of the timber;  it would appear in this case that all of the linings were in place which means the extent of rotting and deterioration of the timber members was only found once the section of soffit lining sheets and floor framing recently fell;  in their opinion strong winds would not have resulted in the collapse of the balcony as the problem is related to water entering into the balcony and long term rotting of the timber floor joists; and  ply sheeting had been used for the support of the tiles whereas current codes require cement sheeting to be used in balconies exposed to the weather. HC‟s letter dated 29 October 2013  it appears when the property was constructed, plywood (as opposed to cement) was an approved method of sheeting for the balcony;  the exact reason for water to be entering the balcony and damaging the timber framing was difficult to determine as extensive rotting, deterioration and collapse had occurred in several areas of the framing;  in this case, it is possible water could have flowed over the edges of the balcony and entered through that area or the waterproof membrane may have failed thereby allowing water penetration; and Case No: 331787 Recommendation Page 4 of 6  in their opinion, it would appear more likely water was entering through the edges of the balcony due to inadequate drip grooves being provided and inadequate waterproofing down the side of the balcony. This allowed water to penetrate underneath the tiles and into the balcony. 16. The FSP therefore submits it is entitled to rely upon the following policy exclusions in denying indemnity for the claim: “ When you are not covered General exclusions applying to Parts A and B [of] this Policy 2. This policy does not cover: ... b) loss or damage resulting from or caused by:  water seeping through a wall of floor, other than escaping from a gutter, drain, tank, pipe, water-bed or other apparatus designed to store or carry any liquid located on or outside the home site; ...  inherent defects, structural defects, faulty workmanship or faulty design;  wear, tear, rust, corrosion, depreciation or gradual deterioration.” 17. With regards to materials used during the construction of the balcony, I am satisfied HC in their letter of 29 October 2013 clarified plywood sheeting was likely an approved material at the relevant time and therefore address the Applicant‟s original submissions on this point. 18. The Applicant has not provided any expert evidence to challenge the reports provided by CC, JL or HC, but submits:  on 21 March 2013, the Applicant‟s home was subjected to wind gusts recorded at 70kmph to 100kmph;  while opinions have been put forward, no-one is certain how the water entered the balcony;  with regards to „gradual deterioration‟, the existence of the ex clusion and its intended application, may be difficult to define and apply to the current dispute;  the loss resulted from storm/rainwater which is covered under the policy. The only question is the period over which the damage took place; and  the Applicant has been insured with the FSP in excess of 10 years and does not have a record of any prior claims. 19. The FSP has not provided any evidence to challenge the Applicant‟s assertion her home was subjected to wind gusts of 70kmph to 100kmph on the day the damage occurred. I am therefore prepared to accept same occurred. Case No: 331787 Recommendation Page 5 of 6 20. However, even if I accept high wind was a trigger mechanism for some of the balcony material separating and falling to the ground, in my view the claim surrounds balcony replacement costs required as a result of the deteriorated condition of the timber structure. 21. It appears clear that deterioration in the condition of the timber is the result of water ingress as opposed to high winds. 22. Whilst accepting the Applicant‟s submission that „no one i s certain how the water entered the balcony‟, in my view there is no dispute water has somehow entered the balcony in order to cause the damage. 23. I also accept the Applicant‟s submission that „the only question is the period over which the damage took place, but there is no question that it took place during [FSP]‟s time on risk‟. 24. With regards to this time period, I note CC, JL and HC all opine the extensive rot throughout the timber indicates this occurring over an extended period of time and possibly years. 25. In light of these expert opinions, I am satisfied such water ingress over an extended period of time, constitutes „loss or damage caused by or resulting from ... water seeping through a floor‟ and/or „gradual deterioration‟ for the purpose of the policy and thereby excluded from cover. 26. However, CC and HC also opine the damage would not have been noticeable to the Applicant until the failure on 21 March 2013. On this basis, the question arises as to whether section 46(2) of the Act has any application. 27. Section 46(2) of the Act states: “(2) Where, at the time when the contract was entered into, the insured was not aware of, and a reasonable person in the circumstances could not be expected to have been aware of, the defect or imperfection, the insurer may not rely on a provision included in the contract that has the effect of limiting or excluding the insurer's liability under the contract by reference to the condition, at a time before the contract was entered into, of the thing.” 28. In the case of Nelson v Hollard Insurance Company Pty Ltd (2010) NSW SC199 (Nelson) the Court considered whether the section would prevent an FSP from relying on an exclusion relating to inherent defects, structural faults, faulty workmanship and faulty design. In applying the pri nciple laid down in an earlier case ( Asteron Life Ltd v Zeiderman [2004] NSWCA 47), the Court held that section 46(2) does not invalidate an exclusion unless that exclusion itself relates to a condition of being or an event at a time before the contract was entered into. 29. Put in a simpler way, section 46(2) of the Act has been interpreted to only apply to exclusions that have a temporal aspect, that is, it only applies to a Case No: 331787 Recommendation Page 6 of 6 clause that makes reference to a defect or imperfection that existed before an insurance contract was entered into. 30. On this basis, I am not satisfied there is any temporal aspect to the relevant exclusion clauses. 31. The Applicant acknowledges this Service is required to follow the decision in Nelson, and it is on this basis I cannot be satisfied section 46 of the Act has application to this dispute notwithstanding her associated comments. 32. Finally, I accept the Applicant has been insured with the FSP in excess of 10 years. However, this Service does not have the jurisdiction to direct the FSP to make any „good will‟ or „ ex-gratia ‟ payment in light of same. 33. For the reasons stated above, I am satisfied the FSP was entitled to deny indemnity for the Applicant‟s claim. Recommendation 34. On the basis of the available information, I recommend the FSP was entitled to deny indemnity for the Applicant‟s claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.