Determination 331514
Plaster ceiling collapse claim denial
Summary
The applicants claimed for a plaster ceiling collapse they attributed to a storm. AFCA accepted the FSP expert's evidence that incorrect adhesive installation caused the collapse, a building defect not covered by the defined-events policy, so the denial was upheld.
The applicants had to establish loss from a covered storm event under a defined-events policy, and the expert evidence showed building defect as the cause, which is excluded.
Subjects and remedies
home or building damageno remedy
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of
claim
Determination
Case No: 331514 Determination Page 1 of 3
Case number : 331514 2 1 October 2014
1 Overview
1.1 Dispute
The Applicants ’ claim is under a home building and contents insurance policy and
relates to the collapse of the plaster ceiling in the family/dining room at the
insured property.
The FSP has denied the claim on the basis that the damage did not occur as a
result of an event insured against under the policy.
1.2 Issue and key findings
Was the FSP entitled to deny the claim?
The FSP is entitled to deny the claim as the Applicants have not established that
the loss and damage arose as a result of an event covered by the terms of the
policy.
1.3 Determination
This Determination is in favour of the FSP.
The FSP is entitled to deny the Applicants ’ claim.
Case No: 331514 Determination Page 2 of 3
2 Reasons for Decision
This Determination has been the subject of a Recommendation issued by the
Service on 6 August 2014. It was the Case Manager’s Recommendation that the
FSP was entitled to deny the Applicants ’ claim as the Applicants have not
established that the loss and damage arose from an event covered by the terms
of the policy.
The Applicants have disputed the Recommendation and ha ve provided further
submissions in relation to the cause of the loss.
I have carefully considered all of the material provided by both parties, before and
after the Recommendation, whilst making this Determination.
2.1 Was the FSP entitled to deny the Applicants ’ claim?
The Applicants ’ policy is a defined events policy which mea ns that the Applicants
are covered for loss and damage arising from causes or events detailed within the
terms of the policy.
The Applicant s’ coverage for loss and damage does not extend to any loss and
damage but only to loss and damage arising from an event detailed within the
terms of the policy.
The policy provides coverage for storm and the Applicants say that the collapse of
the plaster ceiling in the family/dining room was as a result of a storm event.
Whilst the FSP’s expert has stated that when contacting the FSP, the male
Applicant stated that he was laying mice bait on the ceiling when he fell on to the
ceiling causing it to crack, the Applicants say that the area where he was laying
mouse poison was in the hallway some 15 metres from the damage ceiling.
Further, the Applicants say that the FSP has not provided all of the photographs
taken by their expert and some of the photos withheld show storm affected areas
in other parts of the house.
The Applicants have provided a number of photographs to support their position,
including photographs of broken tiles and gaps in the roof.
On the other hand, the FSP’s expert confirms details of the inspection which was
carried out three days after the plaster ceiling collapsed.
The FSP’s expert confirms that the primary cause of the damage to the plaster
board ceiling lining in the family/dining room, is the incorrect spacing and
installation of adhesive. The expert says that the incorrect spacing and installation
of adhesive, combined with accidental pedestrian impact, has allowed the plaster
board ceiling lining to eventually detach from the bottom chord of the truss roof
frame and collapse on the floor below.
The FSP’s expert regards the incorrect spacing and installation of the adhesive to
be defective building work.
Case No: 331514 Determination Page 3 of 3
Whilst the FSP’s expert was of the view that an inspection of the roof tiles from
below reveal no evidence of openings for water to enter the roof void, the
presence of the water stains on the bottom chord of the truss roof frame is an
indication that there may have been a previous water entry into the roof void.
How ever, it is the FSP’s expert’s opinion that if this was the case, the damage
would have been localised and resulted in minor damage such as water staining
of the ceiling lining as opposed to the collapse of the entire ceiling lining.
The Applicants have not produced expert evidence to challenge the opinion of the
FSP’ s expert.
I have had the opportunity to carefully examine the repo rt from the FSP’s expert,
together with the attached supporting photographs.
I am satisfied that the report is thorough and logical and the conclusions are
persuasive.
Given the conclusions of the FSP’s expert, I am satisfied that the cause of the
loss or damage was building defect rather than as a result of a storm as claimed
by the Applicants. The policy does not provide coverage for building defect and as
such, the Applicants have not established a loss or damage arising from an event
covered by the terms and conditions of the policy.
In those circumstances, the FSP is entitled to deny the Applicants ’ claim.