Home / Financial Firm (Unknown - Insurer) / Determination 331514

Determination 331514

Plaster ceiling collapse claim denial

FirmFinancial Firm (Unknown - Insurer)
Decided2014-10-22
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicants claimed for a plaster ceiling collapse they attributed to a storm. AFCA accepted the FSP expert's evidence that incorrect adhesive installation caused the collapse, a building defect not covered by the defined-events policy, so the denial was upheld.

The applicants had to establish loss from a covered storm event under a defined-events policy, and the expert evidence showed building defect as the cause, which is excluded.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim Determination Case No: 331514 Determination Page 1 of 3 Case number : 331514 2 1 October 2014 1 Overview 1.1 Dispute The Applicants ’ claim is under a home building and contents insurance policy and relates to the collapse of the plaster ceiling in the family/dining room at the insured property. The FSP has denied the claim on the basis that the damage did not occur as a result of an event insured against under the policy. 1.2 Issue and key findings Was the FSP entitled to deny the claim? The FSP is entitled to deny the claim as the Applicants have not established that the loss and damage arose as a result of an event covered by the terms of the policy. 1.3 Determination This Determination is in favour of the FSP. The FSP is entitled to deny the Applicants ’ claim. Case No: 331514 Determination Page 2 of 3 2 Reasons for Decision This Determination has been the subject of a Recommendation issued by the Service on 6 August 2014. It was the Case Manager’s Recommendation that the FSP was entitled to deny the Applicants ’ claim as the Applicants have not established that the loss and damage arose from an event covered by the terms of the policy. The Applicants have disputed the Recommendation and ha ve provided further submissions in relation to the cause of the loss. I have carefully considered all of the material provided by both parties, before and after the Recommendation, whilst making this Determination. 2.1 Was the FSP entitled to deny the Applicants ’ claim? The Applicants ’ policy is a defined events policy which mea ns that the Applicants are covered for loss and damage arising from causes or events detailed within the terms of the policy. The Applicant s’ coverage for loss and damage does not extend to any loss and damage but only to loss and damage arising from an event detailed within the terms of the policy. The policy provides coverage for storm and the Applicants say that the collapse of the plaster ceiling in the family/dining room was as a result of a storm event. Whilst the FSP’s expert has stated that when contacting the FSP, the male Applicant stated that he was laying mice bait on the ceiling when he fell on to the ceiling causing it to crack, the Applicants say that the area where he was laying mouse poison was in the hallway some 15 metres from the damage ceiling. Further, the Applicants say that the FSP has not provided all of the photographs taken by their expert and some of the photos withheld show storm affected areas in other parts of the house. The Applicants have provided a number of photographs to support their position, including photographs of broken tiles and gaps in the roof. On the other hand, the FSP’s expert confirms details of the inspection which was carried out three days after the plaster ceiling collapsed. The FSP’s expert confirms that the primary cause of the damage to the plaster board ceiling lining in the family/dining room, is the incorrect spacing and installation of adhesive. The expert says that the incorrect spacing and installation of adhesive, combined with accidental pedestrian impact, has allowed the plaster board ceiling lining to eventually detach from the bottom chord of the truss roof frame and collapse on the floor below. The FSP’s expert regards the incorrect spacing and installation of the adhesive to be defective building work. Case No: 331514 Determination Page 3 of 3 Whilst the FSP’s expert was of the view that an inspection of the roof tiles from below reveal no evidence of openings for water to enter the roof void, the presence of the water stains on the bottom chord of the truss roof frame is an indication that there may have been a previous water entry into the roof void. How ever, it is the FSP’s expert’s opinion that if this was the case, the damage would have been localised and resulted in minor damage such as water staining of the ceiling lining as opposed to the collapse of the entire ceiling lining. The Applicants have not produced expert evidence to challenge the opinion of the FSP’ s expert. I have had the opportunity to carefully examine the repo rt from the FSP’s expert, together with the attached supporting photographs. I am satisfied that the report is thorough and logical and the conclusions are persuasive. Given the conclusions of the FSP’s expert, I am satisfied that the cause of the loss or damage was building defect rather than as a result of a storm as claimed by the Applicants. The policy does not provide coverage for building defect and as such, the Applicants have not established a loss or damage arising from an event covered by the terms and conditions of the policy. In those circumstances, the FSP is entitled to deny the Applicants ’ claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.