Home / Financial Firm (Unknown - Insurer) / Determination 331094

Determination 331094

Denial of garage and kitchen damage claim under earth movement, wear and tear and structural defect exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2014-05-26
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's garage and kitchen were damaged, and the FSP denied the claim as caused by earth movement, wear and tear or defective construction. The Ombudsman found the leaking stormwater pipe the proximate cause, so the FSP must meet the damage claim, while the applicant bears the cost of repairing the pipe itself.

Under the proximate cause test the leaking pipe was the dominant cause of the damage, and the policy excludes the cost of repairing the item that leaked.

Issues

Subjects and remedies

home or building damagepay claimpay interestrepair or rectify

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 331094 Determination Page 1 of 12 Case number: 331094 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim 19 May 2014 Summary Description:  This dispute concerns a claim by the Applicant under a home insurance policy for damage to his kitchen and garage which claim has been denied by the FSP because of its expert opinion about the cause of damage which it says is excluded from cover. Basis for Determination:  The expert opinion varies but on the balance of probabilities it was accepted that the proximate cause of the claimed damage in the kitchen and garage is the escape of water from the broken stormwater pipe which cause of damage is covered under the policy.  The policy excludes the costs incurred in repairing the broken pipe. Determination:  The FSP is to meet its liability for the claimed damage in accordance with the terms and conditions of the policy.  The FSP is to arrange the necessary quotations and repairs to the Applicant‟s garage and the kitchen floor.  The Applicant is responsible for any costs associated with the repair of the leaking stormwater pipe.  If the FSP seeks to cash settle the Applicant‟s claim, the FSP is to pay interest in accordance with Section 57 of the Insurance Contracts Act 1984 from 8 August 2013 being the date of the FSP‟s IDR decision to date of payment of the claim. Determination Case No: 331094 Determination Page 2 of 12 Background 1. The Applicant held a home insurance policy with the Financial Services Provider (FSP) covering his property for a number of listed events. The policy was incepted on 13 December 1997 and was renewed each year. 2. On 7 March 2013 the Applicant‟s son contacted the FSP t o report a hairline crack in the garage had increased following rain. He also reported the garage floor was damp and appeared to be sinking. Later he claimed damage to the kitchen tiles too. 3. After assessing the Applicant‟s claim, the FSP denied liability o n the basis the damage to the garage was due to earth movement and the damage to the kitchen was due to wear and tear. Both causes are excluded from cover. The FSP has since added „faulty workmanship‟ to its reasons for denying the claim. 4. The Applicant dis agrees with the FSP‟s decision and maintains the damage to his property was caused by water escaping from a broken stormwater pipe and thus should be covered under the terms and conditions of the policy. The cost of repairs has not been quantified to date. Summary of Applicant’s position 5. The Applicant has been assisted by his son for the purposes of pursuing this dispute. For the sake of brevity and convenience, submissions made by the Applicant‟s son will be treated as having been made by the Applicant for the purpose of this Determination. 6. The Applicant says he lodged a claim with the FSP in March 2013 when he noticed damage to his garage following large amounts of water coming up through the garage slab from the side of the home whenever it rained. 7. He says the assessor sent by the FSP immediately dismissed the damage being due to anything but soil movement and it was only after his son‟s persistence did the assessor agree to have the pipes at the property tested for any leaks. 8. The Applicant submits the leak detection company appointed by the FSP subsequently discovered a break in the stormwater line under the house towards the left hand side of the garage. The Applicant also said the broken pipe is under the damaged kitchen tile area and this was the area he first noticed was damaged. 9. The Applicant says he could not see the stormwater pipe and thus had no knowledge of any problems with it until the leak detection company located the break. Case No: 331094 Determination Page 3 of 12 10. The Applicant has since repaired the leaking pipe but considers the FSP should be liable for these costs as the damage was not intentional and arose due to an unknown cause. 11. The Applicant disagrees with the FSP‟s contention that the damage to his garage is due to earth movement and/or faulty workmanship and the damage to the kitchen floor tiles is due to wear and tear. 12. The Applicant submits he and his family have lived in the property since early 1998 and had no problems until the stormwater pipe failed. He says the property has been well maintained with any works undertaken by qualified tradespeople and with the necessary Council approvals. In 2003 the Applicant rendered the outside of the garage and put in a new roller door. 13. Early photos of the house show no brickwork damage. 14. Furthermore, the Applicant submits the concrete in fill slab in the garage is more than 25 years old and showed no signs of damage until the stormwater pipe began to leak. 15. The Applicant maintains water leaking from a broken stormwater pipe has caused the damage to his home and as such his claim should be met by the FSP. The pipe has been repaired. The damage to the garage has remained the same. The water logged area is no longer pooling and is drying up. 16. In support of his claim the Applicant relies on an advice report prepared by a prescribed buildi ng practitioner (“S”) following his inspection of the property on 28 October 2013. S also considers the damage to the property is the direct result of water leaking from the broken stormwater pipe. 17. The Applicant is aggrieved the FSP has not given any credence to the report of S and is maintaining its decision to deny his claim. He cannot understand why S‟s opinion has less weight than that of the engineer appointed by the FSP. 18. The Applicant acknowledges that when E inspected the garage it hadn‟t been raining heavily and so there was no pool of water on that day but E was told there was a pool of water in the garage after heavy rain. Summary of FSP’s position 19. The FSP accepts the insured home has sustained damage, however it does not consider the damage can be attributed to an event insured against under the Policy. 20. Furthermore, the FSP submits the cause of the damage falls within exclusions from cover such as „wear and tear‟ and „structural defect‟ in any event. Case No: 331094 Determination Page 4 of 12 21. The FSP relies upon the findings of engineer “E” who was appointed to identify the cause and extent of the damage to the Applicant‟s property. 22. The FSP notes E identified the distress to the concrete in-fill slab of the garage was inconsistent with recent cracking due to its aesthetic appearance and was the result of various specific structural defects. 23. Additionally, the FSP notes E did not consider the leaking stormwater pipe had contributed to the distress because floor level surveys showed no evidence of local heave. 24. The FSP also accepts E‟s view that the cracking to the garage lintel and western wall was, on the balance of probabilities, the result of long term deflection and movement of the lintel. 25. The FSP says the policy explicitly excludes loss or damage caused by or arising from structural defects and but for the defective construction of the garage and ongoing wear and tear, the damage claimed by the Applicant would not exist. 26. Regarding the cracking to the floor tiles in the kitchen, the FSP says it also relies upon E‟s opinion which found the damage to be long-term and due to normal wear and tear. It notes a floor level survey conducted by E showed no evidence of heave, which would be present if the stormwater pipe had leaked. 27. The FSP considers that the photographic evidence on file supports E ‟s view insofar as the cracking appears old in nature and is randomly placed in the kitchen. 28. The FSP submits it is therefore entitled to refuse the claim for damage to the kitchen tiles on the basis there is insufficient evidence to support that a leaking stormwater pipe or any other insured event caused them to crack. 29. Further, the FSP notes the cracking is consistent with wear and tear which is specifically excluded from cover. 30. The FSP submits the Applicant has failed to prove, on the balance of probabilities, a loss or damage caused by an insured event. Further, the FSP submits it has satisfactorily proven the claimed damages fall within exclusions from cover in view of the expert evidence of E . 31. The FSP says that qualifications and expertise of E are to be preferred to the opinions of the Applicant‟s experts as they are supported by robust engineering methodology. 32. The FSP relies on the following policy provisions: “ Home insurance cover Home insurance - What IS covered Home insurance - What is NOT covered Case No: 331094 Determination Page 5 of 12  Escape of liquid from the following. • Any water main or fi xed pipe, gutter or guttering, fixed tank or drain. • A sink, toilet, bath, basin or waterbed. • A fi xed heating or cooling system. • A dishwasher or washing machine. • An aquarium.  Costs incurred in repairing or replacing the item from which the liquid escaped.  Damage caused by condensation. General exclusions applicable to your policy You are not covered under any section of this policy for damage, loss or liability caused by, arising from or involving any of the following. General exclusions applicable to your policy  ...  Water entering your home  as a result of your failure to perform adequate maintenance on your home, or a structural defect, or faulty design or workmanship,  through any opening made for the purpose of repairs or alterations to your home unless you can prove that the loss or damage was caused by the negligence of someone other than you.  ...  Wear and tear, lack of maintenance or inherent defect.  ...  Structural defects or faulty workmanship, settling, shrinkage or expansion. ” Issue 33. Whether the FSP is entitled to deny liability for the Applicant‟s claim. Reasons for decision 34. As advised to the parties, FOS has considered it appropriate to expedite the dispute in accordance with the Operational Guidelines to the FOS Terms of Reference. This is due to the circumstances of the dispute. This matter has not been the subject of a FOS Recommendation and has proceeded directly to Determination. 35. I am satisfied a full exchange of information has taken place between the parties and each party has had the opportunity to address any issues raised. 36. As the Applicant is seeking indemnity under the policy, the onus is on him to establish the damage to his property was caused by an event covered by the Case No: 331094 Determination Page 6 of 12 policy. Once the Applicant has established an insured event is responsible for the damage, the onus is then on the FSP to establish the damage claimed is excluded or not covered by the policy. 37. The parties do not disagree the Applicant‟s property has suffered damage. However, there is disagreement over the cause of the damage. The FSP maintains it is due to faulty workmanship and wear and tear, whereas the Applicant contends it is due to water leaking from a broken stormwater pipe. 38. The damage to the Applicant ‟ s property was initially assessed and photographed by a staff member of the FSP (“T”) on 13 March 2013. The Applicant told T that they had started to notice a crack in the garage wall and it had increased in size and water comes up though the concrete slab in the garage when it rains. 39. The Applicant also advised T a plumber had attended the property for another matter and suggested the damage to the garage might be due to a leaking stormwater pipe underneath. In view of this, T arranged for a leak detection service to check the stormwater pipes on the property. 40. On 26 March 2013, a leak detection service attended the property and inspection of the stormwater lines identified a break in join under house towards the back left hand side of the garage. The lines were otherwise clear. 41. The Applicant then submitted photographs of the kitchen which he also included in the claim then. In view of this and the finding from the leak detection service, T arranged for the damage to be further assessed by an engineer (“E”) not only as to cause but also as to scope. 42. E inspected the property on 24 June 2013. E‟s report dated 8 July 2013 noted the following:  The land is flat and has poor drainage. When it rains the water discharges under the concrete slab in the garage onto the side street. The Applicant found water had ponded under the slab;  The Applicant told E cracking above the garage door was first noticed in late 2012 and has increased since then;  Floor levels survey of the main building showed no discernible pattern of abnormal movement;  Floor levels survey of the garage showed a general relative pattern of settlement towards the southern and northern sides of the garage (E assumed the house faces west).  E assumed highly reactive clay foundation which swells when it rains;  The distress to the concrete in-fill slab of the subject garage does not appear to be recent with the cracks having smooth weathered edges suggesting it has been present for a prolonged period of time; Case No: 331094 Determination Page 7 of 12  The distress is due to a combination of inadequate construction of the concrete in-fill slab and long term consolidation of poorly compacted filling materials underneath;  The broken stormwater pipe has not caused or contributed to the damage to the garage or the kitchen floor as there is no evidence of local heave which would be expected with soil swelling;  The floor level survey did not indicate a pattern of heave in the kitchen floor and E concluded the distress to the floor tiles observed in the kitchen does not appear to be recent and is attributab le to long term „wear and tear; and  The distress above the garage opening is consistent with the long term deflection/movement of the lintel which is supporting the immediate wall surface above it. 43. The FSP did not consider it was imperative to undertake soil testing. 44. In an email dated 5 September 2013, E answered some specific questions of the FSP as follows:  The damage would have occurred regardless of the broken storm water pipe;  E clarified that it suspected the lintel is undersized;  As for the comment about wear and tear, E clarified that the house is about 40 years old, the floor is flat, and the cracks have worn edges and are in areas of traffic. 45. The Applicant did not agree with the findings of E and sought a report from a prescribed building practitioner (“S”) in response. S inspected the Applicant‟s property on 28 October 2013 and prepared a report the same day. 46. S‟s report dated 28 October 2013 specifies the following:  Inspection of the garage revealed cracking propagating across the rendered front wall;  Google maps elevation photo taken in 2011 shows the front rendered masonry wall of the garage to be crack free;  The character of the cracking indicates the front right/southern corner of the garage has experienced a slight outward rotation as well as a slight subsidence;  The front southern corner of the garage has been adversely affected by uncontrolled ground movements resulting in this corner of the garage to rotate outwards as well as subsiding slightly;  The cracks appear to be recent, possibly occurring over the past few months;  The separation between the brick pier & the single skin brick wall at the southern end of the boundary wall indicates the wall has slipped Case No: 331094 Determination Page 8 of 12 outwards rotated outwards. The separation seems to have occurred recently, possibly within the past few months;  Testing the moisture level in the internal garage boundary wall base brickwork revealed an elevated moisture level ranging up to approximately 50%;  Testing the moisture level in the internal garage house wall base brickwork revealed an elevated moisture level ranging up to approximately 48%;  Inspection of the concrete floor inside the garage revealed high moisture content ranging up to approximately 30% in parts;  The moisture levels in the concrete floor slab measured to be the greatest towards/at or around the southern corner of the garage, indicating the greatest amount of moisture has pooled under this section of the garage floor slab which corresponds with the natural topography of the land with this point being the lowest;  Water that leaked out of the broken stormwater pipe would have accumulated and then directed into the sub floor towards the centre of the family room running towards the southern corner of the garage following the natural topography of the land;  Photographs supplied by the property owner showed the condition of the stormwater drain pipe prior to repair. The surface is saturated;  The cracking to the floor tiles in the kitchen indicates uncontrolled movements of the concrete footing along the side eastern walls of the meals area; and  The uncontrolled ground movements can be attributed directly to water accumulation along the length of the concrete footing of this wall resulting directly from the water leaking out from the damaged stormwater drain. 47. S concluded the damage to the house and garage was the direct result of:  Water accumulation along the strip footing of the house resulting from the leaking stormwater drain pipe located under the meals/kitchen area;  Water accumulation along the strip footing of the garage resulting from the leaking stormwater drain pipe; and  Water retained & pooling underneath the concrete floor of the garage resulting from the leaking stormwater drain pipe;  The cracking in the garage wall occurred sometime after 2011 and about early March 2013;  Damage occurred “sometime within the past few months” (that is, on or before October 2013). 48. The Applicant also obtained a report from the plumber (“P”) who repaired the damaged stormwater pipe. P‟s report dated 30 October 2013 states: Case No: 331094 Determination Page 9 of 12 “I the plumber [plumber‟s name] was called to investigate as to why there was flooding in garage and surrounding footings to garage. After investigating I found suspended storm water pipe under house had come apart. It appeared that the water was running on an old concrete path under the house and tracking towards garage causing flooding and damage to footings...” 49. The FSP sought a further report from E in response to the reports of S and P. The additional report from E dated 29 November 2013 refuted the findings of both S and P. Specifically, E‟s supplementary report states:  P has not detailed the alleged damage to the garage footings, nor has he provided details of the mechanism by which leaked water might damage the footings;  The floor level survey taken on 24 June 2013 does not indicate any heave between the leak location and the garage;  S has described water accumulation along the strip footing and water pooling under the concrete floor however, ponding was not observed nor reported by the owner at the 24 June 2013 inspection;  S says the damage is due to uncontrolled ground movements attributed directly to water accumulation but this conclusion has been reached without taking measurements to objectively assess building movement;  S infers the foundation soils would have subsided due to the water leak but this is contrary to accepted engineering knowledge on the behaviour of reactive clay soils. Heave not settlement is e xpected in reactive foundation soils when there is increased moisturise content;  There is inadequate damp proof course at the base of the wall and if was performing adequately there would be no rising damp regardless of the moisture content of the soils;  There is no structural connection between the wall of the garage and the slab, therefore any alleged relative movement between the wall and the slab would not impose force on the edge of the slab;  It is not physically possible for fully cured concrete to ha ve a moisture content of 30%. E says S did not measure the moisture content. Typically it is 6%;  S has not taken floor level surveys in the kitchen area and has therefore drawn a conclusion regarding the damage without having taken sufficient measurements;  The photo of the Applicant‟s property on Google Earth was taken in January 2010 not 2011 and the resolution is not sufficient to state the garage wall was crack free at that time;  S has provided structural advice but he is not a structural engineer;  The repair recommendation made by S is not consistent with the guidance provided in the Australian Standards; and Case No: 331094 Determination Page 10 of 12  The reports of S and P have not provided any new technical information relevant to determining the cause of the observed damage to the building. 50. In relation to the video provided by the Applicant showing rainwater collecting at the property on a wet day, E made the following comments:  The water collection and puddling observed was typical for a wet day;  The wet areas shown on the video are remote from the reported leak in the stormwater pipe and the video does not demonstrate any correlation between that leak and the wet area; and  The efflorescence on the concrete in the garage has been caused by an inadequate/ineffective vapour barrier underneath the slab. 51. Clearly there is no dispute there has been an escape of liquid from a fixed pipe at the Applicant‟s property. The issue in dispute, however, is whether it was this escape of liquid that caused the damage which is the subject of the Applicant‟s clai m. 52. Courts have determined that in order to identify whether a particular damage is covered by a policy of insurance, it is necessary to establish the proximate cause of the damage. This is generally done by determining the dominant or effective cause of the damage. 53. The experts have provided conflicting evidence as to the cause of the damage to the Applicant‟s property. The Applicant‟s expert (S) believes the damage is due to water inundation from the broken stormwater pipe, whereas the FSP‟s expert (E) sa ys the damage is due to wear and tear and faulty workmanship, both excluded from cover. 54. E has stated the observed distress to the western wall of the garage is consistent with the long term deflection/movement of the lintel and the damage to the floor is due to inadequate construction of the concrete in-fill slab or consolidation of the poorly compacted materials underneath. 55. E‟s opinion has been formed based on observations and taking into account the type of soil the property is constructed on and floor le vel surveys in the damaged areas. E does not consider any of the property damage to be due to the leaking stormwater pipe. 56. However, E has not provided comment as to why the damage to the garage has only originated now, some 35 years after the property was built. 57. I have no reason to doubt the Applicant‟s assertion that the damage to the garage and kitchen tiles only appeared after the stormwater pipe broke. There is no evidence before me to indicate otherwise. 58. I accept the resolution of the Google photograp h showing the front of the Applicant‟s property in 2010 is not clear enough to rule out the possibility of small cracks, however it does show the garage door being level with the driveway and no significant wall movement is apparent. Case No: 331094 Determination Page 11 of 12 59. E has stated the Applicant did not report ponding of water in the garage at the time of the initial inspection, however this is at odds with E‟s initial report which states: “The owner stated that during heavy rainfalls large volume of water discharges from SW corner of the garage underneath the concrete in-fill slab into the [name] court at southern side of the property.” 60. The Applicant has provided video evidence showing water build up adjacent to the SW corner of the garage on a rainy day. E says these observations are consistent with what could be expected in wet weather and notes the area is remote to the location of the leak in the stormwater pipe. 61. The Applicant has advised FOS since the leak to the stormwater pipe was repaired, the water logged area to the SW of the garage no longer pooling and the area is slowly drying up. I note natural slope of the land falls to the southern side of the property. 62. The lack of pooling and drying up of the water logged soil adjacent to the SW corner of the garage post repair persuades me that there was a link between the broken stormwater pipe and the excessive water build up in that area. 63. This is consistent with the report of S submitted by the Applicant. 64. E has put forward a number of arguments as to why the opinion of S is flawed. E notes S reached his conclusion without performing floor level surveys to objectively assess whether there has been any actual ground movement. 65. Whilst I appreciate E has undertaken floor level surveys as part of her method in assessing whether there has been any soil movement, I do not consider this evidence resolute given E has also formed her opinion relying on assumptions given the absence of soil testing and the true soil composition being unknown. 66. In my view, if the damage to the garage was due to faulty design and/or workmanship as contended by E, it would be reasonable to expect the damage to have occurred much earlier considering the dwelling was constructed in the 1970‟s. Having considered the expert reports carefully, I therefore find, on the balance of probabilities, the proximate cause of the damage is the leaking stormwater pipe. 67. Furthermore, given the location of the leak in the stormwater pipe, the proximity of the kitchen tiles with damage and the lack of any other damage to the internal part of the property I am also persuaded, on the balance of probabilities, the cracking to the kitchen tiles also occurred as a result of the leaking stormwater pipe. 68. In view of the above, I am satisfied that the Applicant has established, on the balance of probabilities, a valid claim under the terms of the policy. I am not satisfied on the balance of probabilities that the FSP has established that an Case No: 331094 Determination Page 12 of 12 exclusion applies under the terms of the policy to defeat the Applicant‟s claim. 69. The policy states any costs incurred in repairing or replacing the item from which the liquid escaped is not covered. I am satisfied that the policy is clear and unambiguous in this regard. Therefore the Applicant is responsible for the cost of repairs to the broken stormwater pipe. (I note that S suggests at Paragraph 8.1 of his report that the pipe is to be repaired correctly ensuring it is crack free. The Applicant may refer this comment to P to ensure he has no further issues with the pipe). 70. Otherwise, the FSP is responsible for all claimed damage in the kitchen and garage. Determination 71. On the basis of the available information, and for the reasons stated I determine:  The FSP is to meet its liability for the claimed damage in accordance with the terms and conditions of the policy;  The FSP is to arrange the necessary quotations and repairs to the Applicant‟s garage and the kitchen floor;  The Applicant is responsible for any costs associated with the repair of the leaking stormwater pipe; and  If the FSP seeks to cash settle the Appli cant‟s claim, the FSP is to pay interest in accordance with Section 57 of the Insurance Contracts Act 1984 from 8 August 2013 being the date of the FSP‟s IDR decision to date of payment of the claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.