Home / Financial Firm (Unknown - Insurer) / Determination 330696
Determination 330696
Denial of claim
Summary
The applicants claimed under their home building policy for damage to a retaining wall, which the FSP declined. AFCA determined the FSP is entitled to deny the claim and ordered nothing.
The applicants bore the onus of showing impact by a motor vehicle caused the damage, and the evidence established instead that load from heavy vehicles caused it, which is not covered.
Issues
- Claim denial primary · not upheld“The FSP is entitled to deny the Applicants' claim.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Case No: 330696 Determination Page 1 of 6
Case number: 330696
General Insurance - Domestic Insurance - Home Building - FSP Decision -
Denial of claim
22 April 2014
Summary
Description
This dispute concerns a claim by the Applicants under a home building
insurance policy issued by the Financial Services Provider (FSP) for
damage to a retaining wall at their home. The FSP denied the claim on the
basis that the damage occurred because the wall was not structurally
sound.
Basis of Determination
The available information does not establish that the damage to the
Applicants’ retaining wall was caused by impact or any other event insured
under the policy. On the balance of probabilities, the damage was caused
by the additional load placed on the retaining wall as a result of heavy
vehicles using the access route next to it.
Determination
The FSP is entitled to deny the Applicants’ claim.
Summary of Applicants ’ position
1. The Applicants say that:
their retaining wall was hit by a heavy vehicle during construction works
at their home. The impact caused the wall to fall; and
the policy provides cover for loss or damage to the insured building
caused by impact from motor vehicles. Accordingly, they should be
entitled to indemnity for the damage to the retaining wall.
Summary of FSP ’s position
2. The FSP says that:
Determination
Case No: 330696 Determination Page 2 of 6
there is no definitive evidence of any impact to the retaining wall; and
even if there was an impact, this was not what caused the retaining wall
to collapse.
3. The FSP relies on reports by its assessor and structural engineer in support
of its position that the retaining wall collapsed because it was not structurally
sound. The FSP says that the retaining wall was not built well enough to
withstand the pressure placed on it by heavy vehicle traffic driving over the
access route next to the retaining wall.
Issue
4. Whether the FSP is entitled to deny the Applicants ’ claim for damage to their
retaining wall.
Reasons for decision
5. I am satisfied that there has been an exchange of material information
between the parties and that each party has had an opportunity to comment
on the issues raised by the other.
6. It is an accepted principle of general insurance law that an insured bears the
onus of establishing that, on the balance of probabilities, they have suffered
a loss caused by a risk insured under the policy. This is known as a prima
facie claim. If the insured is able to establish a prima facie claim, the onus
then shifts to the insurer to show that, on the balance of probabilities, the
loss falls within an exclusion clause under the policy or that it is otherwise
entitled to deny liability.
7. Accordingly, as the Applicants brought the claim under the policy, they bear
the onus of establishing that the damage to the retaining wall was caused by
a risk insured under the policy (in this case, impact by a motor vehicle).
Terms of the policy
8. The Applicants’ policy provides cover for loss or damage arising from certain
specified events, including impact by a motor vehicle.
9. However, the cover provided for impact is subject to the conditions and
exclusions set out in the policy, including the general exclusion for loss or
damage that is caused by, arises from or involves:
“ a defect, structural fault or design fault that [the Applicants] knew about (or
should reasonably have known about) and did not fix before the loss or
damage occurred (e.g. if there are signs that a defect previously caused
damage, [the FSP] will not pay a later claim for further damage from this
defect). ”
Case No: 330696 Determination Page 3 of 6
10. The FSP says that the Applicants have not established that their re taining
wall was damaged by impact from a motor vehicle and, even if they had
done so, their claim would be excluded because the underlying cause of the
damage was a structural or design fault in the retaining wall.
Available information
11. When the Applicants lodged their claim on 28 March 2013, they reported that
the property had sustained damage the previous week. The FSP’s systems
notes record that the Applicant described the circumstances of the loss as
follows:
“... We have had a few trucks driving up the side of the house causing the
retaining wall to collapse ...”
12. Based on the information provided by the Applicants, the FSP advised them
that their claim would be declined as there was no suggestion that the
damage to the wall had been caused by impact by a motor vehicle. The
Applicants subsequently advised the FSP that a truck had hit the corner of
the retaining wall, causing it to partially collapse.
13. The photographs provided by the parties show that the retaining wall is
located next to, and runs paral lel with, the Applicants’ driveway. It is about
1.5 metres high at its highest point (nearest the house) and approximately 30
centimetres high at its lowest point (nearest the street). A short section of the
retaining wall (the “front retaining wall”) runs perpendicular to the main
section of the retaining wall. On the other side of the main retaining wall from
the driveway is an access route approximately 3 metres wide which slopes
up towards the rear of the property and appears to consist of built up earth.
This route has been used by heavy vehicles to gain access to a construction
site at the rear of the property where the Applicants ’ daughter is building a
house.
14. In their submissions to FOS, the Applicants say that:
a truck or excavator reversed up the side access route and ran over the
front retaining wall;
this caused the front retaining wall to instantly break off, which resulted
in a horizontal crack in the retaining wall approximately 1 to 1.5
centimetres wide;
within a few days, the two metre long section of the main retaining wall
closest to the street collapsed due to vehicles driving up and down the
access route; and
the rest of the main retaining wall remains standing only because
timber props have been installed to prevent its collapse.
15. After the Applicants lodged their complaint, the FSP appointed an assessor
(“PS”) to attend the property and assess the damage. PS attended the
property on 18 April 2013 and reported that the Applicants’ daughter had
advised him that:
Case No: 330696 Determination Page 4 of 6
on the day earth moving works for the new house were scheduled to
commence, she had returned home to find that a 12 tonne excavator
had run over the front retaining wall, thereby destroying the wall. As this
wall is connected to the main retaining wall, the brick work and the
render to the front corner of the main retaining wall were also damaged;
a bigger excavator was then brought in and the weight of this and the
trucks used to remove the earth caused the ground to sink; and
the Applicants arranged for a builder to attend and install props to
prevent the retaining wall from collapsing completely. The builders put
down rubble on the access route so that vehicles could continue to
access the construction site.
16. In his report, PS accepted that the excavator had caused damage to the
front retaining wall and a section of the main retaining wall. However, he
considered that the further damage to the main retaining wall and the render
in other areas of the house was caused by the soil at the side of the house
having been compacted by the earth moving equipment and trucks using the
side access route.
17. On this basis, PS’s view was that the initial damage caused by the impact of
the excavator would be subject to cover, but the further damage would be
excluded as it had not been caused by impact. However, PS recommended
that an engineer be appointed before a final decision on the claim was
made.
18. Following receipt of PS’s report, the FSP contacted the Applicant s to obtain
details of the driver of the excavator which had impacted the retaining wall.
However, the Applicants unadvised that they were unable to provide these
details.
19. The structural engineer (“JH”) engaged by the FSP attended the property on
16 May 2013 and reported that:
the retaining wall had large cracks throughout it and sections of the wall
had completely collapsed, with the remainder being very unstable.
There were also cracks to the front corner of the house and the balcony
column;
the retaining wall was constructed from a combination of concrete
masonry blocks and rendered bricks . The wall was “double skin” with a
total thickness of 230 millimetres. The inner skin was built using 100
millimetre thick masonry blocks and the outer skin was built using
standard face bricks, with a cavity between the two;
there was significant erosion in the area of the access route and tyre
tracks indicated that this had been caused by heavy vehicles and
machinery; and
the retaining wall had been braced with timber planks and props. The
section of the wall which had collapsed showed signs of timber prop
failure, suggesting that the props were placed in anticipation of the
extra load from the machinery.
Case No: 330696 Determination Page 5 of 6
20. Based on his observations, JH concluded that:
the primary cause of the damage was due to the heavy trucks and
machinery driving beside the retaining wall;
the weight of the machinery had increased the load placed on the
retained soil which had exceeded the walls maximum load capacity;
and
the retaining wall had not been designed or constructed to support the
high load from the machinery, as it was not concrete core filled and
contained no reinforcement steel.
21. It is not clear to what extent JH considered whether the damage to the
retaining wall could have been caused by impact, as he did not specifically
refer to this possibility in his report.
22. In its submissions to FOS, the FSP says that the Applicants have failed to
establish that an impact occurred which caused damage to the retaining
wall. The FSP suggests that PS’s initial view that the FSP should accept
liability for the damage to the front retaining wall was incorrect. It suggests
that, rather than the front retaining wall having been damaged by impact, this
part of the wall was deliberately removed by the Applicants in order to
provide greater access to the construction site, before the damage to the
main retaining wall occurred. In support of its position, the FSP refers to
photographs of the area, which it says indicate that the trucks and other
machinery did not pass close enough to either section of the retaining wall to
have directly impacted it.
Analysis
23. I have carefully reviewed the information provided by the parties in relation to
the cause of damage, including the various photographs of the damage
contained in the reports of the FSP’s contractors and provided to FOS by the
Applicants.
24. In my view, the information provided by the Applicants is insufficient to
establish that the damage to their retaining wall was caused by the impact of
a motor vehicle. In this regard, I note that:
the Applicants have not provided any photographs or independent
eyewitness accounts of the impact, and have been unable to provide
the details of the driver of the motor vehicle involved;
while the photographs of the retaining wall and the surrounding area
(and, in particular, the tyre tracks visible in the earth) indicate that the
heavy vehicles involved in the construction works passed close to the
retaining wall, they are inconclusive as to whether any of these vehicles
actually impacted the retaining wall;
the FSP’s structural engineer (JH) concluded that the damage to the
wall was caused by heavy vehicles driving up and down the access
route. As a structural engineer, I consider that JH is suitably qualified to
Case No: 330696 Determination Page 6 of 6
determine the cause of the damage to the retaining wall. I have
reviewed JH ’s report and consider that it provides a logical and
reasonable explanation of how the damage to the retaining wall (and
other areas of the house) occurred; and
the Applicants’ initial report of the damage is consistent with it having
been caused in the manner outlined by JH (ie by vehicles driving up
and down the access route). It was not until later that the Applicants
referred to the wall having been impacted by a heavy vehicle.
25. For the reasons outlined above, I consider that the Applicants have not
established that the damage to their retaining wall was caused by the
insured event of impact. I consider that, on the balance of probabilities, the
cause of damage was the load on the soil imposed by vehicles driving up
and down the access route alongside the retaining wall, which exceeded the
wall’s load bearing capacity. Damage caused in this manner is not subject to
cover under the Applicant’s policy.
Determination
26. On the basis of the available information I determine that the FSP is entitled
to deny the Applicants’ claim.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.