Home / Financial Firm (Unknown - Insurer) / Determination 320303

Determination 320303

Insurer denied water damage claim to bathrooms as excluded gradual process and inherent defect

FirmFinancial Firm (Unknown - Insurer)
Decided2014-01-14
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$24,100
SourceAFCA PDF

Summary

The applicant claimed about $24,100 for water damage to bathrooms that the insurer declined. AFCA found the damage was caused by defective installation and gradual failure of the waterproofing, which the policy excludes, and that citing the wrong PDS version did not change the outcome.

Under a defined events policy the applicant must show a covered event, and the experts' evidence established gradual deterioration and inherent defects, both excluded.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 320303 Determination Page 1 of 9 Case number: 320303 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim 08 January 2014 Summary Description: A claim under a home building insurance policy for loss as a result of water damage to the home. Basis of Determination: A consideration of the circumstances of the Applicant‟s loss as it applies to the relevant policy provisions. Determination: The Applicant has not established that the loss arose from an event covered by the terms of the policy and the exclusions within the policy entitle the FSP to deny the claim. Finally, section 46 of the Insurance Contracts Act (1984) does not apply. Background 1. The Applicant holds a home building insurance policy issued by the Financial Services Provider (FSP) on a defined events basis. 2. The Applicant lodged a claim for water damage to his main and en-suite bathrooms on 3 July 2012. The FSP refused liability for repairs on the basis they were excluded from cover under the policy. 3. The Applicant does not agree that the FSP is entitled to reject the claim and seeks full indemnity for his losses of approximately $24,100. Summary of Applicant’s position 4. The leakages in the bathrooms did not appear until two years after he took possession of the property. 5. He does not accept that a breakdown of the water proofing membrane could be regarded a building defect. The claim should be accepted as resultant damage caused by the sudden escape of water on 17 November 2012. Determination Case No: 320303 Determination Page 2 of 9 6. He did not lodge the claim earlier because he was attempting to pursue the claim through his builder and building warranty insurer. 7. He continues to use the bathrooms because he has no other choice. 8. The FSP‟s engineer‟s report is bias and his finding with respect to the bathrooms‟ design being defective has not been proven. 9. If the bathrooms‟ damage was caused by faulty design and gradual seepage then the damage would have been evidenced earlier. However, the discovery of the leakages did not occur until two years after handover of the property. 10. He was unaware of the defects in the bathrooms and therefore the FSP should be precluded from relying on the policy‟s inherent defect exclusion to deny his claim. 11. The FSP relied on the incorrect policy wording to deny his claim. The claim denial was based on product disclosure statement (PDS) numbered QM1886-0208, but he was provided with a PDS numbered QM2423-0510. S ummary of FSP’s position 12. It has conducted enquiri es into the Applicant‟s concerns regarding the versions of the policy wording on which the claim assessment was based. Although the policy wordings are not identical, there is no significant difference which would change the policy response to the claim. 13. Regardless of which version of the policy wording was used, the policy will only respond when the loss or damage was caused by an insured event. 14. Its expert evidence supports the view that the dominant and effective cause of the damage was due to inherent defects with the shower screen and gradual deterioration of the waterproofing membrane, allowing for seepage of water over time. 15. The damage to the bathrooms was a gradual process and not the result of a sudden escape of water. Such damage is not covered by t he Applicant‟s policy. 16. The onus is on the Applicant to establish on the balance of probabilities that a loss claimed falls within a defined event listed in his policy. 17. The Applicant has not provided any expert evidence to refute the FSP‟s expert evidence. Therefore, it is entitled to rely on its experts‟ opinions, which support its denial decision of the claim. 18. Section 46(2) of the Insurance Contract Act 1984 (the Act) does not apply because the Applicant‟s ignorance of a pre -existing defect is not, by itself, sufficient to attract protection under section 46(2). The section is only Case No: 320303 Determination Page 3 of 9 triggered where an insurer has relied upon a provision which excludes or limits its liability by reference to an object‟s condition at a time before the contract was entered into. 19. The FSP relies on the following policy provisions: “ SECTION 1 INSURED EVENTS CAUSING LOSS OR DAMAGE YOUR BUILDING AND/OR YOUR CONTENTS ... 1.7 Water Or Other Liquid You are insured for damage to your building and/or your contents caused when water or another liquid suddenly escapes from: You or your neighbours;  Plumbing system,  Bath, fixed basin or sink,  Fixed heating or cooling system,  Roof gutter, downpipe,  Shower recess,  Tank  Toilet system,  Washing machine, dishwasher; or  Above ground swimming pool or spa, or The  Road gutter or curbing,  Water main or pipe. ... What you are not covered for There are certain times when this insurance may not provide cover. Some events we may not cover include: ... Damage to your building and/or contents caused by water or another liquid escaping as the result of a gradual process Wear and tear, depreciation, deterioration, atmospheric condition, mould, mildew, insects, vermin, action of light, rot or inherent defect ” . Issue 20. Whether the FSP is entitled to deny the disputed loss. Case No: 320303 Determination Page 4 of 9 Reasons for decision 21. Due to the nature of this dispute, FOS has considered it appropriate to expedite the dispute in accordance with the Operational Guidelines to the FOS Terms of Reference. This dispute has not been the subject of a FOS Recommendation and has proceeded directly to Determination. The parties have been previously advised that a Determination will be issued in this case. 22. I am satisfied a full exchange of information has taken place between the parties and each party has had the opportunity to address any issues raised. 23. The policy provides cover for defined events. Accordingly, the onus is on the Applicant to establish, on the balance of probabilities, that he suffered a loss caused by a risk insured against. Once it has been established that the loss was prima facie caused by a risk insured against, the onus shifts to the FSP to show that the loss is excluded from cover by the policy. 24. Prior to lodging the claim with the FSP, the Applicant engaged his plumber “ RL ” to provide an opinion on the bathrooms‟ damage. RL‟s report of 12 July 2011 provides the following: “We inspected the ensuite floor. The shower base is built up above floor level and the water proofing installed in the shower is not working. When the shower is used it is allowing water to run right across the entire bathroom floor causing the vanity to swell and heating duct covers to rust. This needs urgent attention. The shower should have been installed lower than the remainder of the floor, allowing any excess water through tiles to run to the leak control flange. On inspection of the bathrooms floor, it appears the entire floor has been waterproofed then the poly marble base installed. I believe the shower door opening and perhaps the screen is leaking, allowing lots of water onto the top of tiles. This water is running through gaps in the tiles, around the poly base, vanity, heating duct and pooling in the waterproofing. It is causing a dampness problem, swelling of vanity and rusting of heating duct cover. This also needs urgent attention” . 25. Upon receipt of the Applicant‟s claim notification and plumber RL‟s report, the FSP appointed an assessor, who in turn, engaged building consulting firm “ MBC ” to report on the cause of the damage. 26. MBC Concluded: “ En suite Typically shower floor levels are lower than the ensuite or bathroom floor levels itself as shown in the BCA Part 3.8.1.10. However at this site the shower floor is higher, creating a bath type arrangement between the shower enclosure and the en suite floor. In respect to the en suite seepage problem, this presents as a gradual failure in the water proofing membrane between the hob of the shower and the ensuite floor. Case No: 320303 Determination Page 5 of 9 This damage is not from a leaking pipe as shown by blocking of the water waste outlet and obtaining seeping leaking through the grout at the shower floor/hob junction. (sic) The grouting at the junction should have been a flexible caulking called for in the BCA which is designed to mitigate potential movement in the structure and remain water proof. (sic) These are inherent defects in the building which as eventually become problematic around 3 1/2 year after original construction. (sic) The matter of staining on some areas of the 4 year old grouting relates to a combination of wear and tear and seepage from a failed water proofing membrane allowing water to seep and soak into the grout. The insured can check the actual design of this shower recess with their approved building plans and then speak with the relevant building surveyor who gave approval for this wet area of the building comparing the „as built” building works with the “as approved drawings and specifications” of this area of the dwelling (sic). ... Bathroom This shower screen appears to have been seeping water from original construction and subsequent attempts by the shower screen contractor have not stopped the seepage. This was demonstrated by our onsite testing showing seepage every time was directed against the internal corners, the two corners simply leaked onto the floor tiles outside the enclosed shower recess. There is now some wear and tear to the actual grout and subsequent sealant that was installed by the shower screen contractor, however in our opinion the original defects pre dates the current wear and tear. This visually obvious inherent defect in the building was claimed to be seeping from just after original construction some 4 years ago and has not been rectified by the builder or his sub-contractor. As time has passed the extent of the damage has increased to cause further staining and damage to sections of the yellow tongue sheet flooring around the ducted heating vent in the bathro om” . 27. A civil engineer (RH) was engaged by the FSP to conduct further investigation into the cause of the damage. 28. RH concluded as follows: “ En Suite Shower Recess Our investigations indicate that water is leaking from the en suite shower recess underneath the raised hob and onto the floor of the en suite bathroom. It is also apparent that water is migrating underneath the tiles, and possibly underneath the waterproofing membrane, causing damage to the particle board flooring and skirting boards/architraves. We also note that the base of the shower recess has been installed approximately 30mm (at the highest point) above the floor level of the bathroom. It is therefore apparent that the waterproofing membrane should Case No: 320303 Determination Page 6 of 9 have been installed over the hob, and should have extended underneath the floor tiles of the bathroom for a minimum distance of 50mm. The insured has noted that the damage became apparent between 8 to 10 months ago. The damage was not apparent immediately following handover of the residence. In view of the above, we note our opinion that the cause of the water leak within the en suite bathroom is likely to be one or both of the occurrences noted below. The shower recess waterproofing has not been correctly installed and is therefore defective, or The waterproofing membrane has gradually deteriorated over time, and is now leaking. .. With reference to the Policy Exclusions, we note that the waterproofing membrane is most likely defective. We also consider other elements of the construction to be defective, with reference to AS3740-2004, as follows: The shower recess is considered to be “unenclosed”, as the glass screen has no frame and is not continuous. The bathroom floor should therefore be waterproofed and should be graded to fall to a separate floor waste. We also note that the resulting damage has most likely become worse over time; we note that the leak has been apparent to the insured for a period of between 8 and 10 months. Main Bathroom Shower Recess The shower base within the main bathroom shower recess has been incorrectly installed. We note that the floor tiling has been installed above the level of the floor; however, no hob or barrier has been constructed between the shower recess flooring and the bathroom flooring. Furthermore, we note that the grade of the tiles within the shower recess is defective in that the tiles in front of the drainage outlet had been installed with no fall towards the outlet; and along the left hand side of the shower base, these tiles slope towards the front of the shower recess – i.e. away from the drainage outlet. Given that the shower recess has been installed without a hob, we note that the bathroom floor should have contained a drainage outlet, and should have been graded to slope towards the drainage outlet. Instead, the bathroom floor slopes towards the front door, allowing water to flow into the central heating duct, located adjacent to the left hand wall. AS 3740 also requires that the entire bathroom floor is waterproofed, as the level of the shower base is higher than the floor, and there is no raised hob to prevent the spread of water onto the bathroom floor. We note that the leaks from the shower recess have been apparent to the Insured since the property was purchased, and that subsequent repairs have not been successful. The resulting leaks have caused damage to the central heating duct, bathroom floor tiling, and the vanity unit. ... Case No: 320303 Determination Page 7 of 9 With reference to the policy, we consider that the base of the shower recess including the waterproofing (if this exists) and the shower recess have all been installed as defective items. If one considers that the shower recess should have been constructed as “enclosed” recess (as defined is AS3740 - 2004 – i.e. the shower screen/ shower base/ waterproofing should have been constructed so as to prevent moisture from escaping onto or under the bathroom floor), then the bathroom floor and the floor tiles would be considered to be „not defective. We also note that the damage has been occurring since completion of the residenc e”. 29. The Applicant has not disputed the expert evidence. However, it is central to his submission that:  the FSP is not entitled to deny his claim because it had relied on the incorrect policy wording.  the policy exclusions relied upon by the FSP should not apply to his case because the damage did not occur gradually, but arose from a sudden escape of water/liquid.  he was unaware of the bathrooms‟ defects and as such, the FSP should be precluded from relying on the inherent defect exclusion to deny his claim. The Applicable Policy Wording 30. The FSP acknowledged that it has cited exclusions from an incorrect version of the PDS. It has since corrected this error and provided the version applicable for the relevant policy period. 31. I have examined both PDS ‟ and I accept the FSP‟s explanation that while the wordings were not identical, they both contained exclusions pertaining to loss or damage caused by water or another liquid as the result of a gradual process. Both PDS ‟ also contain a general exclusion for loss or damage resulting from inherent defects. 32. Accordingly, I am satisfied that regardless of which PDS version was used, if the damage is shown to have been caused by one the above mentioned exclusions, then the FSP is entitled to deny the claim. 33. I acknowledge that while the FSP could have paid better attention to this issue, I accept that human errors do occur at times. I am also satisfied that the FSP‟s citing of the incorrect version of the policy wording has not changed the policy‟s response to the Applicant‟ s claim. Whether the Damage Was Caused by a Sudden Escape of Water or another Liquid 34. The Applicant disputes the FSP‟s contention that the damage occurred as a result of a gradual process. He says that it was due to the sudden escape of water, which he only became aware of on 17 November 2010. Case No: 320303 Determination Page 8 of 9 35. Although the Applicant holds this belief, he has not provided any evidence to support the proposition. 36. On the other hand, I note that it is common ground among the parties‟ experts that the bathrooms‟ damage arose from a combination of faulty design and installation of the shower base / screen and a gradual breakdown of the waterproofing membrane, all of which were in existence since construction of the building. 37. As a result, I am not satisfied the Applicant has established, on the balance of probabilities, that the waterproofing membrane failed due to a sudden escape of water or other liquid. 38. Waterproofing membranes are designed for the purpose of preventing water penetration into the subfloor areas. It is not plausible for a single leakage from the shower to cause the failure in the waterproofing me mbrane. For this damage to occur, the water leak must have been happening gradually over a period of time. 39. The expert evidence clearly establishes that the bathrooms‟ damage arose from defective design and installation of the shower base and shower screen, which had led to the failure of the waterproofing membranes. Thus, I am satisfied that any loss or damage caused by the escape of the liquid from these defective areas of the bathrooms is excluded from cover by the policy. Whether Section 46(2) of the Act Applies 40. Section 46 of the Act provides that if a claim is made in respect of a loss that occurred in whole or in part as a result of a defect or imperfection in a thing and the insured was not aware of the defect or a reasonable person in the circumstances could not be expected to have been aware of the defect or imperfection, the insurer may not rely on an exclusion clause that refers to the condition of the thing before the contract was entered into. 41. Case law on section 46 currently holds the view that the section only applies to exclusions that have a temporal aspect. That is to say, it only applies to a policy clause that makes reference to a defect or imperfection that existed before an insurance contract was entered into. It does not apply to exclusion clauses that seek to exclude liability for defects generally. 42. I note that within the relevant policy there was no temporal aspect to the exclusions that relates to defects. Therefore, I am satisfied that section 46 does not apply. 43. After considering the material, I am persuaded that the claimed damage to the Applicant‟ s property was not a result of any of the insured events defined in the PDS. Instead, it was likely to have been caused by a combination of faulty installation of the shower base and screen, which led to the gradual breakdown of the waterproofing membrane. All these causes are specifically excluded from the scope of cover under the policy. Case No: 320303 Determination Page 9 of 9 Determination 44. On the basis of the available information, I determine that the FSP is entitled to deny lia bility for the bathrooms‟ damage.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.