Insurer denied water damage claim to bathrooms as excluded gradual process and inherent defect
Text of the determination
Case No: 320303 Determination Page 1 of 9
Case number: 320303
General Insurance - Domestic Insurance - Home Building - FSP Decision -
Denial of claim
08 January 2014
Summary
Description: A claim under a home building insurance policy for loss as a result of
water damage to the home.
Basis of Determination: A consideration of the circumstances of the Applicant‟s
loss as it applies to the relevant policy provisions.
Determination: The Applicant has not established that the loss arose from an event
covered by the terms of the policy and the exclusions within the policy entitle the
FSP to deny the claim. Finally, section 46 of the Insurance Contracts Act (1984)
does not apply.
Background
1. The Applicant holds a home building insurance policy issued by the Financial
Services Provider (FSP) on a defined events basis.
2. The Applicant lodged a claim for water damage to his main and en-suite
bathrooms on 3 July 2012. The FSP refused liability for repairs on the basis
they were excluded from cover under the policy.
3. The Applicant does not agree that the FSP is entitled to reject the claim and
seeks full indemnity for his losses of approximately $24,100.
Summary of Applicant’s position
4. The leakages in the bathrooms did not appear until two years after he took
possession of the property.
5. He does not accept that a breakdown of the water proofing membrane could
be regarded a building defect. The claim should be accepted as resultant
damage caused by the sudden escape of water on 17 November 2012.
Determination
Case No: 320303 Determination Page 2 of 9
6. He did not lodge the claim earlier because he was attempting to pursue the
claim through his builder and building warranty insurer.
7. He continues to use the bathrooms because he has no other choice.
8. The FSP‟s engineer‟s report is bias and his finding with respect to the
bathrooms‟ design being defective has not been proven.
9. If the bathrooms‟ damage was caused by faulty design and gradual seepage
then the damage would have been evidenced earlier. However, the
discovery of the leakages did not occur until two years after handover of the
property.
10. He was unaware of the defects in the bathrooms and therefore the FSP
should be precluded from relying on the policy‟s inherent defect exclusion to
deny his claim.
11. The FSP relied on the incorrect policy wording to deny his claim. The claim
denial was based on product disclosure statement (PDS) numbered
QM1886-0208, but he was provided with a PDS numbered QM2423-0510.
S ummary of FSP’s position
12. It has conducted enquiri es into the Applicant‟s concerns regarding the
versions of the policy wording on which the claim assessment was based.
Although the policy wordings are not identical, there is no significant
difference which would change the policy response to the claim.
13. Regardless of which version of the policy wording was used, the policy will
only respond when the loss or damage was caused by an insured event.
14. Its expert evidence supports the view that the dominant and effective cause
of the damage was due to inherent defects with the shower screen and
gradual deterioration of the waterproofing membrane, allowing for seepage
of water over time.
15. The damage to the bathrooms was a gradual process and not the result of a
sudden escape of water. Such damage is not covered by t he Applicant‟s
policy.
16. The onus is on the Applicant to establish on the balance of probabilities that
a loss claimed falls within a defined event listed in his policy.
17. The Applicant has not provided any expert evidence to refute the FSP‟s
expert evidence. Therefore, it is entitled to rely on its experts‟ opinions,
which support its denial decision of the claim.
18. Section 46(2) of the Insurance Contract Act 1984 (the Act) does not apply
because the Applicant‟s ignorance of a pre -existing defect is not, by itself,
sufficient to attract protection under section 46(2). The section is only
Case No: 320303 Determination Page 3 of 9
triggered where an insurer has relied upon a provision which excludes or
limits its liability by reference to an object‟s condition at a time before the
contract was entered into.
19. The FSP relies on the following policy provisions:
“ SECTION 1
INSURED EVENTS CAUSING LOSS OR DAMAGE YOUR BUILDING
AND/OR YOUR CONTENTS
...
1.7 Water Or Other Liquid
You are insured for damage to your building and/or your contents caused
when water or another liquid suddenly escapes from:
You or your neighbours;
Plumbing system,
Bath, fixed basin or sink,
Fixed heating or cooling system,
Roof gutter, downpipe,
Shower recess,
Tank
Toilet system,
Washing machine, dishwasher; or
Above ground swimming pool or spa, or
The
Road gutter or curbing,
Water main or pipe.
...
What you are not covered for
There are certain times when this insurance may not provide cover.
Some events we may not cover include:
...
Damage to your building and/or contents caused by water or another liquid
escaping as the result of a gradual process
Wear and tear, depreciation, deterioration, atmospheric condition, mould,
mildew, insects, vermin, action of light, rot or inherent defect ” .
Issue
20. Whether the FSP is entitled to deny the disputed loss.
Case No: 320303 Determination Page 4 of 9
Reasons for decision
21. Due to the nature of this dispute, FOS has considered it appropriate to
expedite the dispute in accordance with the Operational Guidelines to the
FOS Terms of Reference. This dispute has not been the subject of a FOS
Recommendation and has proceeded directly to Determination. The parties
have been previously advised that a Determination will be issued in this
case.
22. I am satisfied a full exchange of information has taken place between the
parties and each party has had the opportunity to address any issues raised.
23. The policy provides cover for defined events. Accordingly, the onus is on the
Applicant to establish, on the balance of probabilities, that he suffered a loss
caused by a risk insured against. Once it has been established that the loss
was prima facie caused by a risk insured against, the onus shifts to the FSP
to show that the loss is excluded from cover by the policy.
24. Prior to lodging the claim with the FSP, the Applicant engaged his plumber
“ RL ” to provide an opinion on the bathrooms‟ damage. RL‟s report of 12 July
2011 provides the following:
“We inspected the ensuite floor. The shower base is built up above floor level
and the water proofing installed in the shower is not working. When the
shower is used it is allowing water to run right across the entire bathroom floor
causing the vanity to swell and heating duct covers to rust. This needs urgent
attention. The shower should have been installed lower than the remainder of
the floor, allowing any excess water through tiles to run to the leak control
flange.
On inspection of the bathrooms floor, it appears the entire floor has been
waterproofed then the poly marble base installed. I believe the shower door
opening and perhaps the screen is leaking, allowing lots of water onto the top
of tiles. This water is running through gaps in the tiles, around the poly base,
vanity, heating duct and pooling in the waterproofing. It is causing a
dampness problem, swelling of vanity and rusting of heating duct cover. This
also needs urgent attention” .
25. Upon receipt of the Applicant‟s claim notification and plumber RL‟s report,
the FSP appointed an assessor, who in turn, engaged building consulting
firm “ MBC ” to report on the cause of the damage.
26. MBC Concluded:
“ En suite
Typically shower floor levels are lower than the ensuite or bathroom floor
levels itself as shown in the BCA Part 3.8.1.10.
However at this site the shower floor is higher, creating a bath type
arrangement between the shower enclosure and the en suite floor.
In respect to the en suite seepage problem, this presents as a gradual failure
in the water proofing membrane between the hob of the shower and the
ensuite floor.
Case No: 320303 Determination Page 5 of 9
This damage is not from a leaking pipe as shown by blocking of the water
waste outlet and obtaining seeping leaking through the grout at the shower
floor/hob junction. (sic)
The grouting at the junction should have been a flexible caulking called for in
the BCA which is designed to mitigate potential movement in the structure
and remain water proof. (sic)
These are inherent defects in the building which as eventually become
problematic around 3 1/2 year after original construction. (sic)
The matter of staining on some areas of the 4 year old grouting relates to a
combination of wear and tear and seepage from a failed water proofing
membrane allowing water to seep and soak into the grout.
The insured can check the actual design of this shower recess with their
approved building plans and then speak with the relevant building surveyor
who gave approval for this wet area of the building comparing the „as built”
building works with the “as approved drawings and specifications” of this area
of the dwelling (sic).
...
Bathroom
This shower screen appears to have been seeping water from original
construction and subsequent attempts by the shower screen contractor have
not stopped the seepage.
This was demonstrated by our onsite testing showing seepage every time was
directed against the internal corners, the two corners simply leaked onto the
floor tiles outside the enclosed shower recess.
There is now some wear and tear to the actual grout and subsequent sealant
that was installed by the shower screen contractor, however in our opinion the
original defects pre dates the current wear and tear.
This visually obvious inherent defect in the building was claimed to be seeping
from just after original construction some 4 years ago and has not been
rectified by the builder or his sub-contractor. As time has passed the extent of
the damage has increased to cause further staining and damage to sections
of the yellow tongue sheet flooring around the ducted heating vent in the
bathro om” .
27. A civil engineer (RH) was engaged by the FSP to conduct further
investigation into the cause of the damage.
28. RH concluded as follows:
“ En Suite Shower Recess
Our investigations indicate that water is leaking from the en suite shower
recess underneath the raised hob and onto the floor of the en suite bathroom.
It is also apparent that water is migrating underneath the tiles, and possibly
underneath the waterproofing membrane, causing damage to the particle
board flooring and skirting boards/architraves.
We also note that the base of the shower recess has been installed
approximately 30mm (at the highest point) above the floor level of the
bathroom. It is therefore apparent that the waterproofing membrane should
Case No: 320303 Determination Page 6 of 9
have been installed over the hob, and should have extended underneath the
floor tiles of the bathroom for a minimum distance of 50mm.
The insured has noted that the damage became apparent between 8 to 10
months ago. The damage was not apparent immediately following handover
of the residence.
In view of the above, we note our opinion that the cause of the water leak
within the en suite bathroom is likely to be one or both of the occurrences
noted below.
The shower recess waterproofing has not been correctly installed and is
therefore defective, or
The waterproofing membrane has gradually deteriorated over time, and is
now leaking.
..
With reference to the Policy Exclusions, we note that the waterproofing
membrane is most likely defective. We also consider other elements of the
construction to be defective, with reference to AS3740-2004, as follows:
The shower recess is considered to be “unenclosed”, as the glass screen has
no frame and is not continuous.
The bathroom floor should therefore be waterproofed and should be graded to
fall to a separate floor waste.
We also note that the resulting damage has most likely become worse over
time; we note that the leak has been apparent to the insured for a period of
between 8 and 10 months.
Main Bathroom Shower Recess
The shower base within the main bathroom shower recess has been
incorrectly installed. We note that the floor tiling has been installed above the
level of the floor; however, no hob or barrier has been constructed between
the shower recess flooring and the bathroom flooring.
Furthermore, we note that the grade of the tiles within the shower recess is
defective in that the tiles in front of the drainage outlet had been installed with
no fall towards the outlet; and along the left hand side of the shower base,
these tiles slope towards the front of the shower recess – i.e. away from the
drainage outlet.
Given that the shower recess has been installed without a hob, we note that
the bathroom floor should have contained a drainage outlet, and should have
been graded to slope towards the drainage outlet. Instead, the bathroom floor
slopes towards the front door, allowing water to flow into the central heating
duct, located adjacent to the left hand wall.
AS 3740 also requires that the entire bathroom floor is waterproofed, as the
level of the shower base is higher than the floor, and there is no raised hob to
prevent the spread of water onto the bathroom floor.
We note that the leaks from the shower recess have been apparent to the
Insured since the property was purchased, and that subsequent repairs have
not been successful.
The resulting leaks have caused damage to the central heating duct,
bathroom floor tiling, and the vanity unit.
...
Case No: 320303 Determination Page 7 of 9
With reference to the policy, we consider that the base of the shower recess
including the waterproofing (if this exists) and the shower recess have all
been installed as defective items. If one considers that the shower recess
should have been constructed as “enclosed” recess (as defined is AS3740 -
2004 – i.e. the shower screen/ shower base/ waterproofing should have been
constructed so as to prevent moisture from escaping onto or under the
bathroom floor), then the bathroom floor and the floor tiles would be
considered to be „not defective.
We also note that the damage has been occurring since completion of the
residenc e”.
29. The Applicant has not disputed the expert evidence. However, it is central to
his submission that:
the FSP is not entitled to deny his claim because it had relied on the
incorrect policy wording.
the policy exclusions relied upon by the FSP should not apply to his
case because the damage did not occur gradually, but arose from a
sudden escape of water/liquid.
he was unaware of the bathrooms‟ defects and as such, the FSP
should be precluded from relying on the inherent defect exclusion to
deny his claim.
The Applicable Policy Wording
30. The FSP acknowledged that it has cited exclusions from an incorrect version
of the PDS. It has since corrected this error and provided the version
applicable for the relevant policy period.
31. I have examined both PDS ‟ and I accept the FSP‟s explanation that while the
wordings were not identical, they both contained exclusions pertaining to
loss or damage caused by water or another liquid as the result of a gradual
process. Both PDS ‟ also contain a general exclusion for loss or damage
resulting from inherent defects.
32. Accordingly, I am satisfied that regardless of which PDS version was used, if
the damage is shown to have been caused by one the above mentioned
exclusions, then the FSP is entitled to deny the claim.
33. I acknowledge that while the FSP could have paid better attention to this
issue, I accept that human errors do occur at times. I am also satisfied that
the FSP‟s citing of the incorrect version of the policy wording has not
changed the policy‟s response to the Applicant‟ s claim.
Whether the Damage Was Caused by a Sudden Escape of Water or another
Liquid
34. The Applicant disputes the FSP‟s contention that the damage occurred as a
result of a gradual process. He says that it was due to the sudden escape of
water, which he only became aware of on 17 November 2010.
Case No: 320303 Determination Page 8 of 9
35. Although the Applicant holds this belief, he has not provided any evidence to
support the proposition.
36. On the other hand, I note that it is common ground among the parties‟
experts that the bathrooms‟ damage arose from a combination of faulty
design and installation of the shower base / screen and a gradual breakdown
of the waterproofing membrane, all of which were in existence since
construction of the building.
37. As a result, I am not satisfied the Applicant has established, on the balance
of probabilities, that the waterproofing membrane failed due to a sudden
escape of water or other liquid.
38. Waterproofing membranes are designed for the purpose of preventing water
penetration into the subfloor areas. It is not plausible for a single leakage
from the shower to cause the failure in the waterproofing me mbrane. For this
damage to occur, the water leak must have been happening gradually over a
period of time.
39. The expert evidence clearly establishes that the bathrooms‟ damage arose
from defective design and installation of the shower base and shower
screen, which had led to the failure of the waterproofing membranes. Thus, I
am satisfied that any loss or damage caused by the escape of the liquid from
these defective areas of the bathrooms is excluded from cover by the policy.
Whether Section 46(2) of the Act Applies
40. Section 46 of the Act provides that if a claim is made in respect of a loss that
occurred in whole or in part as a result of a defect or imperfection in a thing
and the insured was not aware of the defect or a reasonable person in the
circumstances could not be expected to have been aware of the defect or
imperfection, the insurer may not rely on an exclusion clause that refers to
the condition of the thing before the contract was entered into.
41. Case law on section 46 currently holds the view that the section only applies
to exclusions that have a temporal aspect. That is to say, it only applies to a
policy clause that makes reference to a defect or imperfection that existed
before an insurance contract was entered into. It does not apply to exclusion
clauses that seek to exclude liability for defects generally.
42. I note that within the relevant policy there was no temporal aspect to the
exclusions that relates to defects. Therefore, I am satisfied that section 46
does not apply.
43. After considering the material, I am persuaded that the claimed damage to
the Applicant‟ s property was not a result of any of the insured events defined
in the PDS. Instead, it was likely to have been caused by a combination of
faulty installation of the shower base and screen, which led to the gradual
breakdown of the waterproofing membrane. All these causes are specifically
excluded from the scope of cover under the policy.
Case No: 320303 Determination Page 9 of 9
Determination
44. On the basis of the available information, I determine that the FSP is entitled
to deny lia bility for the bathrooms‟ damage.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.