Cyclone Yasi home building claim: extent of liability
Summary
The applicant claimed for Cyclone Yasi damage to his home. The FSP had paid $14,860.89 and accepted some further items, and AFCA largely upheld the denial of the rest as excluded, but required a cash settlement for the ridge capping, floor sanding and kitchen tiles, with interest from 28 October 2011.
Once the insured establishes a prima facie claim the insurer must prove an exclusion applies, and rust, corrosion, wear and tear, structural defects and faulty workmanship are excluded.
Subjects and remedies
home or building damagenatural disasterpay claimpay interest
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Claim
amount
Determination
Case No: 313391 Determination Page 1 of 6
Case number: 313391 4 September 2014
1 Overview
1.1 Dispute
The Applicant lodged a claim with the Financial Services Provider (FSP) for
damage to his home building caused by Tropical Cyclone Yasi in 2011.
While it accepted liability for part of the damage, the FSP denied liability for the
majority of the claimed damage on the basis it was excluded from cover under the
Applicant‟s home building insurance policy.
The Applicant disagrees with the FSP‟s decision and wants a revi ew by the
Service. Submissions made by the Applicant‟s representative are taken to have
been made by the Applicant.
1.2 Issue and key findings
What is the extent of the FSP’s liability with respect to the Applicant’s
claim?
The FSP‟s liability with respect to the Applicant‟s claim is limited to:
the damage to the ridge capping of the roof of the Applicant‟s home
an amount for repair of damage to the floor boards and replacement of kitchen
wall tiles
the amount the FSP has already paid to the Applicant.
This is because the evidence indicates that the cause of most of the remaining
damage claimed was either structural defects or faulty workmanship or design, or
corrosion, rust, gradual deterioration or wear and tear, which are excluded from
cover under the policy.
1.3 Determination
This Determination is substantially in favour of the FSP.
The Applicant is required to provide the FSP with a quotation for the reasonable
cost of repair to the roof‟s ridge capping, along with the cost to sand the timber
floors and replace the kitchen tiles.
The FSP is required to provide a cash settlement based on this assessment, with
interest payable on this settlement, calculated from 28 October 2011.
Case No: 313391 Determination Page 2 of 6
2 Reasons for Determination
2.1 What is the extent of the FSP’s liability for the claim?
FSP has accepted liability for certain damage to the home
It is accepted that Tropical Cyclone Yasi affected the Applicant‟s home building in
February 2011 and caused some damage.
The FSP arranged for a builder and subsequently two engineers to inspect the
damage to establish the cause and the extent of its liability.
The FSP accepted liability for certain damage, including that resulting from water
entry to the building and some building damage caused by the cyclone. It has
paid the Applicant an amount of $14,860.89 (plus interest and less the claim
excess) for cleaning to various rooms of the home and repair of damage to:
the garden shed
a section of roof guttering
the ceiling in the front room
wall panels and window glazing in the living/dining rooms.
The FSP has also agreed to pay for the sanding of wooden flooring to repair
cupping damage caused by water entry from the roof and replacement of the
kitchen wall tiles, although it is understood that the Applicant has yet to provide a
quotation for this repair work.
Evidence establishes that other damage claimed is excluded from cover
It is an accepted principle of general insurance law that an insured bears the onus
to show that they have suffered a loss caused by an event to which the policy
responds. This is known as a prima facie claim. Once so established, the onus
shifts to the insurer to prove the application of an exclusion if it seeks to deny or
limit its liability for the loss.
The policy provides cover for accidental loss or damage and noting that the FSP
has already accepted liability for some of the claimed damage, it is accepted that
a prima facie claim has already been established. The onus therefore is on the
FSP to prove the application of one or more exclusions.
Both the FSP and the Applicant have provided various reports in support of their
respective positions:
Party Report
Applicant Pre - purchase home inspection report by “FB” (undated -
understood to be from 2009)
Applicant Quotation for new roof by “D” (20 May 2011)
Applicant Roof structure report by “FRC” (7 June 2012)
Applicant Engineer‟s inspection report by “KBC” (11 June 2013)
Applicant Report from builder by “G” (undated - understood to be circa
June/July 2014)
Case No: 313391 Determination Page 3 of 6
FSP Assessment report by builder “JL” (undated - understood to be
mid 2011)
FSP Engineer‟s inspection report and scope of works by “S”
(28 October 2011)
FSP Engineer‟s inspection report by “K” (5 August 2013)
FSP Engineer‟s second report by “K” (14 July 2014)
The report by FB provides information to the Applicant about the general condition
of the home at the time he was considering purchasing the property. The
Applicant says that based on this report, he had “good faith belief” that the home
was in sound repair with no abnormality in the ceiling cavity.
While it is accepted that the 2009 report by FB identified no major issues in the
home building, this cannot be seen as a guarantee that:
no other issues were present in the building but not observed at the time
issues may not have occurred or developed over the subsequent months and
years.
The report by FB therefore cannot be seen as definitive with respect to the
claimed damage from Cyclone Yasi two years later.
The quotation by D and the report by FRC indicate that the roof requires
replacement but do not provide any information with respect to the cause or
causes of the damage and are of limited value for the purpose of establishing any
liability under the policy.
The report by JL indicates the extent of the damage to the Applicant‟s building but
notes that not all the damage was caused by the cyclone and that there appeared
to be pre-existing damage. It recommends the appointment of a building
consultant and engineer. While this report provides an indication that the FSP
may be liable for some of the observed damage , but not all, this report is similarly
of limited value.
The report by KBC includes clear observations of the damage and provides
opinions as to its cause. While the opinions provided by KBC are la ter challenged
in the report from K, the report by KBC is considered to be valuable in
establishing the presence, extent and cause of the damage.
Of all the reports, those provided by K provide the most comprehensive and
reasoned explanations for the dama ge to the Applicant‟s home. It is noted that the
views of K generally accord with the views of S.
On the basis of these reports, it is accepted that on the balance of probabilities:
the bowing of the northern wall was not due to strong winds or water entry
caused by the cyclone, but due to previous repairs which involved the
installation of cable ties in the roof cavity. This is considered to be a structural
defect and/or faulty workmanship, which is excluded under the policy and the
FSP is therefore not liable for the damaged northern wall.
the water which caused the damage to the ceiling (among other things) was
allowed to enter the roof cavity due to the valleys on the exterior roof being
Case No: 313391 Determination Page 4 of 6
inappropriately designed or constructed. While the FSP has accepted liability
for the resultant water damage inside the building, it is not liable for the
rectification of the exterior roof valleys.
the denting to some roof sheets was due to foot traffic on the roof, either at
installation or when the fixings have been checked but in any event, this
damage was not caused by the cyclone event. While there would appear to be
no policy exclusion applicable to this damage, coverage under the policy
would need to be considered under the auspices of a separate claim, if the
Applicant were prepared to lodge one with the FSP (noting that a separate
excess would apply if the FSP accepted liability for such a claim).
although K has noted that the damage to the ridge capping is unusual for
various reasons, the FSP has not established that an exclusion applies and is
therefore liable for this damage.
with respect to the remaining damage to the roof, it is accepted that corrosion
of the roof sheets and screws, along with wear and tear, was the proximate
cause. Although KBC has indicated that sandblasting brought about by the
cyclone and salt water contamination may have contributed to the damage, K
has provided satisfactory reasons why this is unlikely. As the policy excludes
rust, corrosion, gradual deterioration and wear and tear, the FSP is not liable
for this remaining damage to the roof.
The Applicant is required to provide a quotation for the reasonable cost of repairs
to the damage to the ridge capping (along with the quotation which has already
been requested for the cost to sand the timber floors and the cost to replace the
kitchen wall tiles). The FSP is required to provide a cash settlement to the
Applicant based on the quotations so provided.
Interest at the statutory rate is applicable to this settlement, calculated from 28
October 2011, being the date upon which S provided its report to the FSP.
3 Supporting information
3.1 Policy provisions
Accidental damage cover
We will cover your buildings … f or any accidental loss or damage.
…
Any cover we provide is subject to exclusions.
Exclusions to your cover
Accidental Damage cover …
We will NOT cover any loss or damage as a result of, or caused by
…
erosion, rust, corrosion, gradual deterioration, depreciation, wear or tear
Case No: 313391 Determination Page 5 of 6
…
a defect in an item, structural defects, or faulty workmanship or design .”
3.2 Relevant evidence from parties
Document Key points
Applicant’s engineer
(KBC)
Report 11 June 2013
dislocation of wall tiles in the kitchen and cover strips to
dining room and kitchen
the north wall of the Applicant‟s home building showed signs
of severe deformity as a result of pressure exerted by high
winds
the building‟s roof was fairly old but showed no signs of
damage except to the west facing section wh ich bore the
brunt of the storm
damaged ridge capping, sandblasting effect and salt water
contamination which has led to corrosion to numerous roof
sheets
areas of impact damage to the west elevation
uplift to areas of roof sheets due to high winds
corrode d roofing ridge screws
the use of incorrect valley irons in the initial construction
minor separation between the rafters and battens in areas
but suggested that this could be attributed to shrinkage of the
timbers
Applicant’s builder
(G)
Report (undated)
Photos showing water ingress along wall studs to an area
behind kitchen tiles.
Water ingress plus strong winds (as detailed in KBC report)
contributed to buckling of north wall frame and popping of
wall tiles.
FSP’s Building
consultant (S)
Report 28 Oct 2011
Majority of water has entered interior at termination of valley
flashing where it meets lower section of roof
Valley at this location is virtually flat rather than „V‟ shaped
and allows water to flow to the outer edges
There is a significant void in the roof space at this location
and S opines that strong winds would drive water into roof
space
Traffic damage observed to roof sheets on several planes
Damage to several sections of ridge capping consistent with
being caused by cyclone
Some roof fasteni ngs had loosened – not consistent with
cyclone damage
No recent uplift of roof frame. Evidence that 50mm
separation of one batten from rafter was present when
cladding installed and therefore pre - dated cyclone.
Several window panels and small section of gutter damage in
cyclone and garden shed destroyed
However apart from ridge, condition of roof is age related
wear and tear, not from cyclone.
Case No: 313391 Determination Page 6 of 6
FSP’s engineer (K)
Report 5 Aug 2013
wind pressures to the north wall may have created vibrations
which damaged the kitchen wall tiles (replacement of tiles
recommended) but no other indicators of frame movement
warping of the north wall was not due to the cyclone (but
perhaps due to the cladding being installed before cable ties
in the roof cavity were tightened, or the use of undried or
semi - dried wood in the construction)
corrosion had created holes of significant size through roof
sheeting on southern elevation, under laps between sheets
due to a lack of long - term maintenance and not sandblasting
lifting of rid ge capping from wind pressures possible but
location of lifting observed unusual. Also no deformity to
softer lead flashings from event.
Denting to roof sheeting did not show typical signs of impact
damage from storm debris – likely from foot traffic at
in stallation or when checking sheet fixings
Drainage issues – agreed with findings of report by S.
Missing guttering may have been caused by rusted brackets
Batten lift – agreed with findings of report by S
Cupping of timber floors caused by water entry – sa nding
recommended
FSP’s engineer (K)
Report 14 July 2014
water ingress shown in report by G only minor
no other indicators of movement to wall framing
no evidence that winds caused removal of television aerials
or guttering (apart from a small section) so winds not strong
enough to warp wall
warping of wall most likely due to previous repairs (which
seem to have included installation of cables in roof cavity) or
use of undried or semi - dried wood (which twists and bends
as it dries over time)
photos with re port by G show studs used in kitchen wall are
of different timber (suggesting previous replacement) and
90x90mm dimensions (prone to warping as drying takes
place).
photos also show lining of kitchen wall is Masonite – a
dimensionally unstable material that shrinks and swells with
moisture change. Water ingress may have caused tiles to
pop, although incorrect installation may also have caused the
wall sheeting to fai l.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.