Home / Financial Firm (Unknown - Insurer) / Determination 310901

Determination 310901

Denial of building damage claim after January 2011 severe weather

FirmFinancial Firm (Unknown - Insurer)
Decided2014-08-18
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

A homeowner's claim for building damage after the January 2011 severe weather was denied as gradual damage. AFCA found the policy covered accidental damage and the FSP had not proven an exclusion, so it must pay the claim with interest on any cash settlement and contribute up to $3,000 to an engineer's report.

Once the insured establishes a prima facie accidental damage claim, the insurer bears the onus of proving an exclusion, which it did not discharge given conflicting expert evidence.

Issues

Subjects and remedies

home or building damagenatural disasterpay claimpay compensationpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim Determination Case No: 310901 Determination Page 1 of 6 Case number : 310901 14 August 2014 1 Overview 1.1 Dispute The Applicant lodged a claim against his home building insurance policy held with the Financial Services Provider (FSP) following the severe weather events in January 2011. The FSP denied the Applicant’s claim for building damage on the basis it was not caused by a single insured event but occurred over a period of time and was due to events which are excluded from cover. The Applicant disagrees with the FSP’s decision and seeks a review by the Service. 1.2 Issues and key findings Is the FSP liable for the damage to the Applicant’s building ? The FSP is liable for the damage to the Applicant’s building because:  the policy covers accidental loss or damage  the Applicant has established that, on the face of the facts, his home was accidentally damaged  the FSP has not satisfactorily shown that a policy exclusion applies to defeat the Applicant’s claim. 1.3 Determination This Determination is in favour of the Applicant. The FSP is liab le for the damage to the Applicant’s home building. Should the FSP cash settle any part of the Applicant’s claim, in accordance with policy provisions, the FSP is to pay interest on the cash settlement amount, in accordance with the Insurance Contracts Act 1984, from the date of denial of the claim, until the date of settlement. Case No: 310901 Determination Page 2 of 6 2 Reasons for Determination 2.1 Is the FSP liable for the damage to the Applicant’s building ? Applicant’s policy was for accidental loss or damage Section Three of the Product Disclosure Statement booklet provided by the FSP explains the Accidental Insurance Cover of the policy. It states that:  if the Applicant has home accidental cover, it will be shown on their certificate of insurance  under this accidental cover, if accidental loss of or accidental damage to the Applicant’s home occurs, the FSP will either repair or replace the lost or damaged portion of the home, or pay him the amount it would have paid for the repair or replacement (less the applicable excess). The Certificate of Insurance confirms coverage for accidental loss or damage to the home and contents. The FSP’s argument that the Applicant’s policy was for defined events is not accepted. Sections One and Two describe the Home Insurance Cover and Contents Insurance Cover respectively and there is no doubt that those covers are both for defined events. The material provided by the FSP indicates that the Applicant’s level of cover was for “Classic with Accidental Damage option” (for both building and contents). However, the policy wording does not indicate that the Accidental Insurance Cover is an optional extra to the Home or Contents Insurance Covers. Rather, it appears that it can be selected as an alternative to the Home Insurance Cover and/or the Contents Insurance Cover. It is therefore accepted that the Applicant’s policy provided him with cover for accidental loss and accidental damage, as described in Section Three of the policy booklet. On that basis the specific exclusions of the defined event covers for Home and/or Contents Insurance would not apply to the Applicant’s policy. Applicant has established a prima facie claim under the policy It is an accepted principle of general insurance law that an insured bears the onus to establish, on the face of the facts, that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. Once so established, the onus shifts to the insurer to prove the application of an exclusion if it seeks to deny or limit its liability for the loss. According to the definition section of the policy, accidental damage means damage that is sudden, unforseen and occurs without intent. The Applicant has stated that when he arrived back from Sydney after the severe weather events in January 2011, he found that his home building had been significantly damaged and the Applicant has provided photographs to show the nature and extent of this damage. Case No: 310901 Determination Page 3 of 6 It is therefore accepted that the Applicant has established a prima facie claim for accidental damage and the onus now shifts to the FSP to prove the application of an exclusion. FSP has not satisfactorily shown that an exclusion applies The FSP r elies on reports from engineers “J” and “C” and contends that the damage to the Applicant’s building:  was due to foundation settlement over time  was due to structural defects and faulty workmanship  has been happening over an extended period of time and well prior to the claimed event. J provided reports dated 11 April 2012 and 11 September 2012, a letter dated 14 February 2012 (assumed to be 2013) providing additional information about the penetrometer testing performed and a supplementary report dated 13 December 2013. J argued that:  there are differences in the density of the fill and the natural ground upon which the home is located and could be the cause of differential foundation movement over time  the retaining wall of the building was not constructed in accordance with standard engineering practices. C provided a report dated 4 January 2013 which, in the main, supported the position of J. The report by C also noted that:  the 2007 pre-purchase inspection report for the property noted that there were a number of settlement cracks to the front retaining wall and heavy bindings to doors in the house at that time  the absence of cross bracings to the lower floor, which were specified on the original house plans but were not installed by the builder, means the building would have little capacity in resisting wind loads and ground movement. Many of the statements put forward by J and C have been contradicted by engineer “R”, who provided a report dated 21 November 2013, with respect to the home and the damage to it. It is noted that J later provided additional information in February 2012 (assumed to be 2013) which stated that the foundation soil bearing capacities (both fill and non-fill areas) were satisfactory for the type of construction, contrary to the position J took in earlier reports. Further reports by J and C were provided (dated 13 and 17 December 2013 respectively) in response to the report by R:  J conceded that it had altered its opinion and conclusions but maintained that the movement of the timber framed structure was the result of poor construction practices and the omission of cross-bracing between the steel support posts  C referred to the approved plans for the building and noted that the actual building works were different to these plans. Case No: 310901 Determination Page 4 of 6 It is clear that the experts engaged by both parties have differing opinions with respect to the damage and its cause. Based on the evidence provided with respect to the soil testing and the floor levels, it seems highly unlikely that ground movement (settli ng, subsidence, shrinkage) caused the damage claimed. Further, C argues the retaining wall did not reveal any degree of deviation from its original position and was not out of alignment but also argues that the retaining wall was not properly constructed. It is not disputed that the local council approved the construction of the house, including the revised wall and in light of this and the inconsistencies in the logic of the arguments put forward by C, it is therefore difficult to accept that a structural defect in the retaining wall caused the claimed damage. C has stated that cross bracing to the lower floor of the home was not installed by the builder. However, the Applicant has provided photographs of walls in the lower floor area which show cross bracing in place, albeit to a lesser degree than shown on the depictions of the plans provided by C. In addition, while C has stressed the importance of cross bracing to the stability of the home, it cannot be concluded that the absence of cross bracing caused the claimed damage to the building. After a consideration of the evidence presented, it is concluded that the FSP has not proven the application of any of the exclusions relevant to the Accidental Insurance Cover. Accordingly, the FSP is liable for th e damage to the Applicant’s home. Further, the FSP is required to contribute up to a maximum of $3,000 towards the Applicant’s cost for the report by R dated 21 November 2013, subject to the Applicant producing appropriate proof of the costs incurred. 3 Supporting information 3.1 Expert reports Report Key points FSP’s engineer J Reports: - 11 April 2012 and - 11 Sept ember 2012  there are difference s in the density of the fill and the natural ground upon which the home is located  the retaining wall of the building was not constructed in accordance with standard engineering practices: o the original site plans show the wall was to be constructed in a different location and was to retain about half the soil it is now retaining o the size of the footings were less than expected for the wall size and retained load o horizontal steel was not able to be located in places where it would reasonably be expected o there was no drainage medium at the base and no base drain at the Case No: 310901 Determination Page 5 of 6 bottom of the wall o the waterproofing behind the wall is non compliant . FSP’s engineer J Letter 14 Feb 2013 The results of dynamic cone penetrometers testing of the home’s foundation soil indicates that the bearing capacities of both fill and non - fill area are acceptable for the type of construction. FSP’s engineer C Report 4 January 2013  the 2007 pre - purchase inspection report noted a number of settlement cracks to the front retaining wall, and heavy bindings to doors at that time  the building would have little capacity in resisting wind loads and ground movement due to the absence of cross bracings. Applicant’ s engineer R Report 21 November 2013  the floor levels show that vertical movements have not occurred and the rise in the central part of the house is normal for slab - on - ground construction  t he southern side of the home, which is located on fill, has not experienced any movement and this area is in fact slightly higher than the northern side (which is located it the cut ground)  the bearing capacities of the foundation soils (both fill and natu ral ground) are satisfactory  cracking to the retaining wall, noted in the pre - inspection report, is normal for buildings on reactive clay soils and construction standards of 1981  there is a plastic membrane present behind the wall and agricultural drainage pipe at the bas e  the central bow in the retaining wall, the southerly lean of the supporting posts and the lateral translation of the upper floor diaphragm are consistent with lateral pressures to the back of the retaining wall  local council approval of c onstruction in 1981 indicates that the work complied with the standards at the time FSP engineer J Supplement ary report 13 December 2013 Maintained previous position that the movement in the timber framed structure is a result of poor construction practices plus the omission of any cross - bracing . FSP engineer C Supplement ary report 17 December 2013  Comparison of house plans to construction: o plans show cross bracing to several walls on lower level, yet the builder “simply did not install them during construction” o plans show retaining wall locat ed at in the cent re of the home, retaining fill to 600mm. However the constructed wall is located at the front of the home retaining soils to 1.9m o plans show f ooting s of 500mm x 400mm (for fill height to 600mm) but structural analysis shows footing for wall “is far from adequate to support 1.9m high fill obs erved” and movement would have occurred over life of structure o plans show 75mm agric ultural pipe at the bottom of rubble fill at base of wall, but inspection s show only PVC pipe and thin layer of pebble fill.  at southern elevation, PVC pipe connected to small drain which is also collecting overland flow from higher up and water from retaining wall Case No: 310901 Determination Page 6 of 6 would not drain effectively.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.