Denial of commercial property claim for soot contamination from ventilation works, and handling of the claim
Text of the determination
Case No: 309530 Determination Page 1 of 12
Case number: 309530
General Insurance - Small Business - Commercial Property - Service - Delay in
claim handling
9 December 2013
Background
1. The Applicant is a Lot Owner under a Commercial Strata Insurance policy
held with the Financial Services Provider (FSP) since 14 July 2010.
2. From late 2009, the Applicant’s premises suffered from soot contamination
associated with the air conditioning. Despite various attempts to rectify the
problem, the Applicant’s tenant in Lot 1 who opera ted an art gallery was
unable to continue operating the business. Gallery stock was damaged by
soot and contaminants and there were also health issues associated with the
use of the space.
3. In March 2012, the Applicant in his then capacity as Secretary of the Owners
Corporation and as the Insurance Broker who arranged the policy on behalf
of the Corporation lodged a claim with the FSP seeking the following:
Unspecified items of damage to the building (covering both common
property and Lot owners property) and other items said to be in excess
of $98,000, pursuant to the FSP’s Policy 1;
A potential liability to a tenant for amounts of approximately $740,796
which related to a possible claim by ‘AG’ the tenant of Lot 1 of the
Strata Plan, pursuant to the FSP’s Policy 2;
Health issues to unidentified occupiers and owners of Lots in the Strata
Plan as a result of exposure to poor air quality – quantum as yet not
estimated, pursuant to the FSP’s Policy 2.
4. The Applicant subsequently lodged a claim in his capacity as the Lot Owner
of Lot 1. The Applicant notified the FSP (through its Solicitors MA) that he
sought indemnity for the loss sustained as a result of the contamination of
his premises.
5. The FSP whilst acknowledging the Applicant has standing as a Lot Owner
under the policy, maintains the Applicant only has standing as per the policy
in respect of Policy 1 – Insured Property – Special Benefits 1, 2, 12, 14, 19,
23, 24.
Determination
Case No: 309530 Determination Page 2 of 12
6. The FSP raised the issue of the jurisdiction of FOS to deal with this dispute
in view of the magnitude and variability of the claims made by the Owners
Corporation, the tenant and the Applicant.
7. On 30 July 2013, FOS issued a jurisdictional ruling determining that the
dispute before FOS as lodged by the Applicant can only proceed in respect
of the Applicant’s claim for damages to the Applicant’s premises and related
costs under Policy 1 and Policy 10.
8. Insofar as there may be other claims made by the Applicant or by the
Applicant in his former capacity as the Secretary of the Owners Corporation,
those claims are outside the jurisdiction of FOS under the Terms of
Reference.
Summary of Applicant’s position
9. The Applicant has provided detailed submissions to the Service and through
his lawyers. The relevant submissions that relate to his claim for benefits
under Policy 1 and 10 can be summarised as follows:
As a Lot Owner, he suffered damage to his unit and other direct
financial loss as a result of the defective ventilation system. The
defective ventilation system rendered Lot 1 unfit for occupation by his
tenant under a commercial lease which had commenced on 5 October
2009. As a result of the defective ventilation system, he was in breach
of his commercial lease with his tenant and seeks compensation for
loss of rent in respect of Lot 1 and also temporary accommodation.
Temporary accommodation was provided via an upstairs unit which the
Applicant had previously owned. He was permitted to retain space
whilst his unit Lot 1 remained unfit for occupation. He offered this space
to his tenant as a sign of good faith in anticipation issues with Lot 1
would be resolved.
In relation to the FSP’s allegation that the problems with the air
conditioning and ventilation system were pre-existing, the Applicant
maintains that at the time of inception of the policy, there were no
known defects or damage as inferred by the FSP that pre-dated the
inception of the policy.
10. The Applicant specifically denies any allegation that he has failed to provide
requested information and material and maintains he has made every effort
to assist the FSP. It was the FSP’s loss assessor who derailed the
investigative process.
11. The Applicant maintains he is entitled to cover as a beneficiary under the
policy as per Policy 1 and Policy 10 for his losses; and as per Annexure A to
the claim form submitted by the Applicant to the FSP on 21 February 2013
he claims total losses of $210,805.45, under the provisions.
Case No: 309530 Determination Page 3 of 12
Summary of FSP’s position
12. The FSP says that the Applicant has not provided the required material to
substantiate a claim under Policy 1 and Policy 10, despite repeated requests
for further information.
13. The FSP says that there is a non-disclosure issue with the policy as the
problems with the soot and contamination had been occurring since 2009,
before the policy was incepted with the Owners Corporation in July 2010.
14. When the policy was incepted in 2010 neither the Owners Corporation (with
Applicant as secretary) nor the broker (with the Applicant as the principal),
disclosed the issues with the soot and contamination. It was not disclosed at
the renewal of the policy in 2011.
15. Further, Policy 1 excludes loss or damage caused by the ‘non -rectification of
an Insured Property defect’ and the costs of ‘rectifying faulty or defective
materials or workmanship’.
16. The Applicant also failed to promptly notify it of the damage which has
prejudiced its ability to properly investigate the claim.
17. It has not admitted a claim under Policy 1 and the Applicant has failed to
establish that Lot 1 was unfit for occupation.
18. The Applicant has no entitlement to bring a claim under Policy 10 as he does
not fall under the definition of ‘You’ in Policy 10.
19. Further, the items claimed under Policy 10 do not fall within the definition of
‘Lot Owners’ Fixtures and Improvements’.
20. There is no cover for loss of income.
Issues
21. Whether the Applicant has established the policy responds to the claimed
damage?
22. Whether the FSP has established any policy exclusions apply to defeat the
claim?
23. Whether the Applicant has established the claimed damage rendered Lot 1
unfit to be occupied for its intended purpose?
24. Whether there was a disclosure issue at policy inception or renewal in terms
of the ventilation system?
25. Whether the Applicant failed to promptly notify the FSP of the alleged
damages and loss and whether that has prejudiced the FSP’s ability to
properly investigate the claim?
Case No: 309530 Determination Page 4 of 12
26. Whether the Applicant has failed to comply with the FSP’s requests for
information?
27. Whether the Applicant has standing under the policy in respect of Policy 10?
Reasons for decision
28. As advised to the parties, FOS has considered it appropriate to expedite the
dispute in accordance with the Operational Guidelines to the Terms of
Reference. This is because of the issues to be considered. This dispute has
not been the subject of a FOS Recommendation and has proceeded directly
to Determination.
29. The decision has been made by a Panel of three decision makers, including
an Ombudsman and decision makers with experience in the insurance
industry and consumer rights.
30. Both parties have submitted a substantial body of materials in respect of
their respective positions, all of which has been exchanged. The Panel has
carefully considered all of the material submitted by the parties, prior to
making its determination and makes the following findings.
Has the Applicant established the policy responds to the claimed damage?
31. The policy provides broad form accidental loss/damage indemnification; as
the relevant PDS states: ‘Policy 1 – Insured Property. This policy is designed
to cover you for accidental loss or damage to your insured property (building
and common area contents) that occurs during the period of insurance. ’
32. Policy 1 incorporates ‘Special Benefits’ ; of which the following are relevant to
this dispute: ‘1a Temporary accommodation’; ‘1b Rent’ and ‘1f Lot Owners’
contributions and fees’. Broadly, these provisions allow for the individual lot
owners to be indemnified under the policy for the period of time their lot/unit
‘is damaged and made unfit to be occupied for its intended purpose by any
Event not excluded under Policy 1 or General Exclusions’ . Monetary limits
also apply; in respect of 1a and b ‘up to 15% of the Property sum insured’
(which in this matter is stipulated on the Certificate of Insurance as
$394,500) and 1f up to a total of $1,000.
33. Policy 10 provides indemnification: ‘against ACCIDENTAL LOSS or
DAMAGE to Lot Owners’ Fixtures and Improvements’ ; the definition of what
constitutes same is: ‘any item or structure installed by a Lot Owner for their
exclusive use and which is permanently attached to or fixed to Your building
so as to become legally part of it, including any improvements made to an
existing fixture’.
34. In order for the Applicant to establish a prima facie claim under Policy 1 -
Special Benefits he must demonstrate the damage was accidental. The
policy does not define “accidental”, however it is generally accepted that the
term “accidental” means “an unlooked for mishap or untoward event which
Case No: 309530 Determination Page 5 of 12
was not expec ted or designed.” In other words, the question is whether any
damage represented an unexpected and unintended mishap?
35. The Panel notes the letter from lawyers (HH) acting on behalf of the tenant,
in her damages claim against the air conditioning specialists PH dated 28
November 2011, in which the following appears: ‘AL (trading name of
enterprise – Panel note) entered into a commercial lease for Shop 1 of the
premises on 5 October 2009……..Within a couple of months of entering the
shop, black sooty granules and black pollutant residue were identified on the
walls and the art works……In late 2009 PH was retained to investigate and
identify the source of the soot ingressing Shop 1 and to take the required
corrective action to resolve the problem.’
36. The Applicant i n his letter to the FSP’s loss assessor F, dated 02/05/2012
noted:
PH attended the premises on a number of occasions carrying out a
series of what turned out to be ‘band aid works’ to correct the problem;
After several attempts to correct the problem PH returned to the site in
July 2010 for re-evaluation;
PH provided a scope of works in July 2010 as a result of investigations
recommending changes to the existing air conditioning system;
The scope of works presented in July 2010 recommended the removal
of all the flexible internal ductwork and renew, clean the fan coil and
reroute the outside air supply to the rear of the building and install a
new outside air grill and filter box;
PH relocated the outside air supply of shop 1 tenancy to a semi
enclosed street level car park;
This car park has no mechanical ventilation and relies upon natural air
circulation to exhaust vehicular emissions;
PH failed to connect the filter box for the new outside air supply on the
inside wall of shop 1 tenancy to the filter box on the outside wall in the
car park with hard duct which then allowed for the source of outside air
supply to be drawn directly from a cavity between the two brick walls;
The double brick wall is connected to a riser which runs up the back of
shop 1 tenancy and is connected to an underground car park exhaust
system;
Compromised air supplied to shop 1 tenancy from the new outside air
installation was distributed throughout the tenancy via the air
conditioning system and severely polluted the tenancy;
PH was made aware of the deteriorating situation within shop 1
tenancy on a number of occasions and after many frustrated attempts
finally attended the premises in May 2011;
By virtue of qualification and industry experience PH would have made
the same observations as contained in the NDY report yet he made no
comment other than recommend the tenancy be positively pressurised;
Case No: 309530 Determination Page 6 of 12
On 28 June 2011 according to “HH” PH positively pressurised the
tenancy by adding a fan unit into the outside air supply duct inside the
shop 1 premises which was commissioned to operate 24/7 regardless
of whether the air conditioning within shop 1 premises was operational
or not which then accelerated the ingress of contaminated air from the
cavity and new outside air installation.
37. Following an inspection of the property, NDY reported on 24 August 2011:
‘The Outside Air supply intake to the space has been relocated from the front
of the building on Victoria road to the rear above ground car park area. Its
current location is in breach of the separation requirements of supply and
exhaust air systems as they are located within 6 meters (sic) of each other.
An additional axial inline booster fan has been installed to increase the
volume of outside air to the system.’
38. Having considered the information provided, it appears to the Panel that up
until PH’s ‘relocation of the outside air supply of shop 1 tenancy to a semi
enclosed street level car park’, that the work undertaken by PH, represented
various attempts (apparently unsuccessful) to solve a technical problem,
namely the continuing infestation of the interior of shop 1 tenancy with
carbon deposits.
39. The Panel has difficulty in determining from the material exactly when the
relocation occurred. According to the FSP and supported by invoices
provided by PH, recommended the relocation of the air supply intake on 28
July 2010 and this work was completed by 3 August 2010.
40. The Panel is satisfied that whilst the shop was experiencing contamination
from pollutants prior to inception of the policy on 14 July 2010, the work
performed at the property between 28 July 2010 and 3 August 2010 and
again when the tenancy was positively pressurised on 28 June 2011 most
likely resulted in unintended and unexpected damage and accordingly, the
Panel is satisfied based on the information exchanged the damage
sustained to the property was accidental.
41. Further, the Panel is satisfied based on the information exchanged that it
was not until 24 August 2011 when the Applicant received the report from
NDY that the Applicant properly understood the cause of the damage.
Whether there was a disclosure issue at policy inception or renewal in terms of
the ventilation system?
42. There is no dispute between the parties that there were issues with the
ventilation from as early as late 2009 with soot ingress into Lot 1.
43. PH was engaged to investigate and repair the source of the problem. The
information exchanged establishes that PH performed a number of
rectification works prior to inception of the policy in July 2010 and following
continued problems, performed work through to renewal of the policy in July
2011.
Case No: 309530 Determination Page 7 of 12
44. There were a number of documents from PH which identified work
performed on or about 17 October 2009, 21 January 2010, 28 July 2010, 3
August 2010, 20 July 2011 and 28 July 2011.
45. There is no dispute that the Applicant as the then Secretary of the Owners
Corporation, Landlord of Lot 1 and the insurance broker responsible for the
inception of the policy, was aware of issues with the air conditioning prior to
inception of the policy.
46. The FSP maintains that the Applicant has not provided relevant answers to
allow it to determine whether or not there has been a non-disclosure. It is
unclear what other material the FSP was awaiting to enable it to properly
investigate this issue as there appears to have been a very full exchange of
material between the parties.
47. It is clear from the policy quotation slip that the Applicant has identified
machinery breakdown and identified the air conditioner fan as being an
issue. It identifies the air con ditioning fan as ‘not finalised’ and ‘with u/w’
(presumably u/w is underwriter). The Panel is satisfied that at the time of
inception of the policy, the Applicant had informed the FSP of an ongoing
issue with the air conditioning fan. Based on the information provided, the
Applicant’s notification with respect to this problem has been provided to the
FSP prior to inception of the policy. There is no reason based on the
information exchanged, for the Applicant to believe that the rectification work
conducted by PH prior to inception of the policy was not successful.
48. The Panel further notes that prior to renewal of the policy on 14 July 2011,
the work conducted by PH on 28 June 2011 suggests it would be reasonable
for the Applicant to believe the problem had been resolved.
49. The duty of disclosure required under Section 21 of the Act requires an
insured to disclose before a relevant contract of insurance is entered into,
every matter that is known to the insured being a matter that the insured
knows or a reasonable person in the circumstances could be expected to
know to be a matter relevant to the decision of whether the insurer will
accept the risk and if so on what terms.
50. The Applicant in this case as insurance broker, Secretary of the Owners
Corporation and Landlord clearly knew prior to the inception of the policy on
14 July 2010 that there were issues with the air conditioning that was
causing soot contamination of his unit at Lot 1.
51. In his capacity as Secretary of the Owners Corporation and the insurance
broker responsible for the inception of the policy, he was aware that issues
relating to the soot contamination would be issues relevant to the
consideration as to whether the FSP would offer insurance.
52. The Panel accepts however that the Applicant did in fact inform the FSP of
the issues with the air conditioning. It would appear from the information
exchanged that he has informed the FSP that the issues had not been
finalised. Whilst the proposal does not precisely document the soot
Case No: 309530 Determination Page 8 of 12
contamination, the Panel is satisfied that the identification of the air
conditioning fan being an issue and not finalised, was sufficient to alert the
FSP and insofar that it may have been an incomplete notification, did not
serve to mislead the FSP as to the nature of the ongoing issues.
53. The Panel is further satisfied that on renewal of the policy, it was reasonable
for the Applicant to believe the ongoing issues had been resolved.
Has the Applicant established the claimed damage rendered Lot 1 unfit to be
occupied for its intended purpose?
54. The NSW WorkCover Authority issued an ‘Improvement Notice’ dated
03/04/2012 which provided that on that date, Strata Plan 55966 was
contravening the Work Heath and Safety Act 2011. The report states:
‘Workers may be exposed to risk to health, safety and welfare as a result of
atmospheric contaminants (e.g. carbon dioxide) due to outside air being
taken from the rear above ground car park area and supplied into Lot 1 via
the current ventilation system. e.g. Consultation advice from NDY (dated 24
August 2011) indicated that “ the outside air supply intake to the space has
been relocated from the front of the building on Victoria Road to the rear
above ground car park area. Its current location is in breach of the
separation requirements of supply and exhaust air systems as they are
located within 6 meters (sic) of each other. ”’
55. According to HH’s letter of 28 November 2011:
‘[trading name of company] wrote a letter of demand to you on 4 July 2011
notifying [name of PH] that she could no longer operate her business due to
the damage sustained to her artworks, fixtures, fittings, contents, general
unclean appearance of the inside of the tenancy (blackened walls, ceilings
etc) and of the potential health problems presented to clients attending Shop
1, her employees and self. Most importantly, she notified you she was holding
[name of PH] responsible for any damages and losses suffered as a
consequence of [name of PH]’s negligent actions including inaction’.
56. Some confusion arises from the letter of HH in reference to the letter of
demand on 4 July 2011 as to the date on which the Applicant’s tenant was
no longer able to operate her business. The Panel is concerned that the
information provided in HH’s letter implies that the tenant was no longer able
to operate her business due to the damage from on or about 4 July 2011. If
this were the case, it would appear that the tenant was no longer able to
operate in her premises after the additional work performed by PH on 28
June 2011 caused additional damage accelerating the ingress of
contaminated air from the cavity. If this were the case then there well may be
a claim for accidental damage and loss of rent from that date.
57. The Applicant however is adamant that the tenant left the property on 5
October 2010. In response to the query from the Panel, the Applicant
confirmed his claim that the tenant had moved out on 5 October 2010. When
informed that other information on the file indicates the gallery may have
been operating after October 2010, the Applicant advised following the
installation of the filter box to the rear car park, the problem was
exacerbated. According to the Applicant what they did not know at that time,
Case No: 309530 Determination Page 9 of 12
was that PH had failed to complete the installation and had left out a piece of
duct that would have connected the two filter boxes. The tenant had to move
out in October 2010 because of the contamination.
58. According to the Applicant, the tenant’s stock and contents remained on the
premises despite the premises not being fit for use or occupancy and the
tenant was unable to remove the stock and contents due to the
investigations and testing conducted.
59. This seems at odds with other information, such as the tenant having a
clairvoyant operating out of the business in November 2010, the delay in any
claim being made and the letter of 4 July 2011.
60. The Applicant has been unable to supply a copy of the letter of 4 July 2011.
The FSP has provided no information to clarify the relevant period the unit
was vacant.
61. Whilst the Panel is satisfied on balance the tenancy was vacated and the
evidence suggests that the premises were capable of reoccupation in or
about July 2012, the Panel is unable to determine the precise period the unit
was unfit for occupation by the tenant.
Has the FSP established any policy exclusions apply to defeat the claim?
62. The FSP asserts that ‘Exclusion 1 d’ operates to defeat the claim. The
exclusion reads: ‘We will not pay for loss or damage : caused by non-
rectification of an Insured Property defect, error or omission that You were
aware of, or should reasonably have been aware of.’
63. There is no dispute that issues existed with the air conditioning prior to
inception of the policy. It is clear based on the information exchanged that
soot h ad been ingressing into the Applicant’s unit since late 2009. The
Applicant in his own letter to the FSP’s loss assessor on 2 May 2012
confirmed that he believed PH had carried out a series of what turned out be
bandaid works to correct the problem. It is apparent from the information
exchanged that the Applicant had notified PH shortly prior to inception of the
policy of the ongoing issues. It is not clear however that the Applicant was
aware of the nature of the property defect. In fact, based on the Appl icant’s
information, he believed that PH was properly qualified and was attending to
the repairs. It was not in fact until the inspection of the property by NDY and
the subsequent supply of that report to the Applicant that the Applicant
became aware that the defect was in fact caused by the outside air supply
intake being relocated from the front of the building to the rear above the car
park area. The Applicant became aware that the current location was in
breach of the separation requirements.
64. The Panel accepts on balance that the intervention of PH in rerouting the
outside air supply intake space to the rear of the building above the car park
area was the proximate cause of the soot contamination that caused the
premises to be vacated and in these circumstances, the Panel is not
Case No: 309530 Determination Page 10 of 12
satisfied that this was an insured property defect that the Applicant was
aware of or should reasonably have been aware of.
Whether the Applicant failed to promptly notify the FSP of the alleged
damages and loss and whether that has prejudiced the FSP’s ability to
properly investigate the claim?
65. The Panel notes the Applicant lodged a claim on behalf of Strata 55966 on
27 March 2012, in which he flagged that individual Lot Owners may also
have been affected by the ventilation issues. On 28 August 2012, MA on
behalf of the FSP responded by letter to E law firm who were then acting on
behalf of the Owners Corporation of Strata 55966. MA’s letter makes no
mention of any such prejudice and in fact refers to the investigations into the
claim by the insurer being ongoing; it is also relevant that F, the loss adjuster
appointed by the FSP to assess the claim, had been actively engaged in that
task from 4 April 2012 until 7 August 2012.
66. In the circumstances, the Panel is satisfied that the FSP having been aware
of the nature of the potential claim from 27 March 2012 has not been
prejudiced by an alleged late notification of the Applicant’s actual claim. The
Panel accepts that the FSP was put on notice from March 2012 that the Lot
Owner’s rig hts may have been affected and accordingly, no prejudice arises
from the Applicant’s lodgement of the claim as an individual Lot owner in
February 2013.
Whether the Applicant has failed to comply with the FSP’s requests for
information?
67. The FSP’s loss assessor F first attended on site on 4 April 2012 with the
Applicant and his tenant; on 10 April 2012 F by letter requested information
from the Applicant. The Applicant responded by email dated 24 April 2012,
enclosing 61 pages of relevant information; F by letter dated 27 April 2012,
requested clarification of some matters and the Applicant responded by letter
dated 02 May 2012, responding to F’s queries and enclosing another 19
pages of relevant documentation. F by email dated 7 May 2012 sought more
clarification of some issues, which the Applicant attended to by email on 7
August 2012. On 28 August 2012, the FSP briefed its lawyers MA, who then
assumed carriage of the matter. From that time on, the FSP through its
lawyers has maintained the Applicant has failed to comply with its requests
for information relevant to its claim assessment process.
68. The Panel is satisfied that the information on file does not support such an
allegation being levelled at the Applicant; rather it would appear the FSP
disengaged from the claim assessment process in August 2012, by way of
briefing MA. From that stage on there does not appear to have been any
effort by the FSP to elicit information from the Applicant in a manner
conducive to assessing his claim.
Whether the Applicant has standing as a Lot Owner under Policy 10?
69. The FSP asserts the policy precludes individual Lot Owners from claiming
under Policy 10 as the definition of ‘You’ is confined to: the Body Corporate,
Case No: 309530 Determination Page 11 of 12
Corporation, Owners Corporation, Plan or Company named in the Schedule
including…the interest therein of Members’. Further, the FSP asserts the
items claimed by the Applicant pursuant to Policy 10, venetian blinds,
paintwork and carpet do not fall within the relevant definition in respect of
‘Lot Owners’ fixtures and improvements’ which requires: ‘any item or
structure installed by a Lot Owner for their exclusive use and which is
permanently attached to or fixed to Your building so as to become legally
part of it, including any improvements made to an existing fixture.’
70. ‘You, Your and Yours’ is defined in respect of Policies 1, 8 and 10 to mean
the Body Corporate, Corporation, Owner’s Corporation, Plan or Company
Name in the schedule and only includes Lot Owners in respect of special
benefits 1, 2, 12, 14, 19, 23 and 24 of policy 1 and Special Benefits 1, 2, 4 of
policy 8. The definition does not include Lot Owners for the purpose of policy
10.
71. In the circumstances, policy 10 does not extend to provide cover to the
Applicant.
72. For the sake of completeness the Panel notes there is no Special Benefit
capable of responding to the Applicant’s claim for $22,000 as loss of income
incurred while attending to this matter.
Quantum
73. The Applicant held a properly executed lease in respect of the tenant which
provided for tenancy from 5 October 2009 to 7 October 2011 at a monthly
rent of $5,500 plus GST.
74. From the documentation on file the Panel cannot identify the exact period for
which Lot 1 was unfit for occupation for its intended purpose. The Applicant
maintains the tenant vacated the premises on 5 October 2010. The Applicant
concedes that the premises were capable of re-occupation in or about July
2012. Other information suggests the tenant may not have vacated until July
2011. The separate statement of claim for the tenant against PH supports a
view that the tenant did not vacate until July 2011. Under the policy, the FSP
is liable to pay special benefits 1b – Rent including any GST obligations
during the period for which the premises were vacated. The Applicant is
required to provide confirmation of the period the premise were vacated and
subject to confirmation being provided, the FSP is to assess its liability and
pay the Applicant the benefits as per Special Benefits 1b of policy 1 of the
terms of the policy.
75. In respec t of the Applicant’s claim for reimbursement of payments made by
him for temporary accommodation for his tenant, the Panel notes Special
Benefits 1 a ‘Temporary Accommodation’ arises ‘When you occupy Your
Lot/Unit We will pay the reasonable cost of Temporary Accommodation You
necessarily incur.’ As the Applicant did not occupy his Lot/Unit, no
entitlement accrues to the Applicant pursuant to this benefit.
76. In respect of Special Benefits 1 f ‘Lot owners’ contributions and fees’, the
Panel notes the benefit reads: ‘We will pay up to $1,000 a Lot/Unit, for
Case No: 309530 Determination Page 12 of 12
contributions, levies, maintenance and other fees You are required to pay
during the period Your Lot/Unit is made unfit to be occupied for its intended
purpose by any Event not excluded by Policy 1 or General Exclusions’.
77. The Panel determines the Applicant is entitled to the maximum benefit
available under this provision namely, $1,000.
Determination
78. Accordingly, the Panel determines the FSP is to meet its liability under policy
1 to pay the Applicant’s claim for Special Benefits 1b Rent in accordance
with the terms of the policy.
79. The Panel further determines that the FSP is entitled to deny liability for
reimbursement of the temporary accommodation costs for his tenant as the
policy does not extend to cover such costs.
80. Insofar as the Applicant’s claim for Lot owners’ contribution and fees, the
Panel determines the FSP is to pay the Applicant the maximum benefit
under the terms of the policy of $1,000.
81. The Panel further determines that policy 10 does not extend to cover the
Applicant’s loss as claimed.
82. The Panel determines the FSP pay interest on any cash settlement in
accordance with Section 57 of the Insurance Contracts Act 1984 from 21
April 2013 being two months from lodgement of the Applicant’s claim to date
of payment of the claim.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.