Determination 305766

Tile damage claim denied under faulty workmanship exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2013-06-26
ProductGeneral Insurance · Strata
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

A unit owner claimed for tiles that lifted throughout his unit under a body corporate strata policy, and the insurer denied the claim as faulty workmanship. AFCA accepted the expert evidence of faulty installation and found no breach in failing to provide the policy to him, so the denial stands.

Once a prima facie claim is shown the insurer must establish the exclusion, and the expert evidence of non-compliant installation met that onus.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 305766 Determination Page 1 of 6 Case number: 305766 General Insurance - Domestic Insurance - Residential Strata Title - FSP Decision - Denial of claim 25 June 2013 Background 1. This Determination follows the review of a Recommendation issued on behalf of the Service on 14 May 2013. The Applicant has rejected the Recommendation. 2. The Applicant is a unit owner within a multi storey unit complex. The body corporate for the complex entered into a residential strata insurance policy with the Financial Services Provi der (FSP). The policy covered “Building including Common Contents” for a sum insured of $14,877,796, and was current at the time of the loss. 3. The Applicant lodged a claim in relation to tiles that “erupted” throughout his unit in June 2012. 4. After assessing the claim, the FSP denied liability on the basis that the loss was caused by faulty workmanship, which is excluded under the policy. 5. The Applicant disputes the FSP‟s denial and seeks indemnity under the policy. Summary of Applicant’s position 6. The Applicant disputes the FSP‟s denial of his claim on the basis that:  the FSP breached its contract as a copy of the policy was not provided to the Applicant prior to the loss and therefore he was not aware of the policy terms and conditions;  a number of similar claims for damage to tiles in other units in the complex have been accepted by the FSP;  during the building of the complex, all stages of construction were inspected and approved and a certificate of occupancy was issued. This is inconsistent with the FSP‟s submission that the loss was due to faulty workmanship; Determination Case No: 305766 Determination Page 2 of 6  one of the contractors (“ATS”) whose opinion as to the cause of the damage is being relied upon by the FSP never inspected the Applicant‟s unit but based his report on an inspection of other units in the complex; and  the Applicant has provided a report from another tiler (“JS”) that supports his position that the loss was not caused by faulty workmanship. 7. The Applicant seeks to be indemnified for the damage to the tiles in his unit. Summary of FSP’s position 8. The FSP relies on reports by two experts (ATS and MS) to support its view that the damage to the tiles was caused by faulty workmanship. 9. Based on these reports, the FSP considers that the Applicant‟s claim falls within the exclusion under the policy for “[t]he failure of or a defect in any item, faulty workmanship, structural defect or fau lty design”. 10. In response to the other issues raised by the Applicant, the FSP says that:  the policy was held by the body corporate and arranged through an insurance broker. Accordingly, the FSP was not required to provide a copy of the policy to each of the unit owners;  it has only accepted claims for tile damage in other units in the complex where the insured has established that the damage was caused by an event covered by the policy (eg storm damage). Where the damage was caused by incorrect installatio n, it has denied the claims;  it acknowledges that its handling of the Applicant‟s claim has fallen below an acceptable standard. It has apologised for its failure to respond to some of the Applicant‟s enquiries as a result of technical issues and administrative errors, which have now been corrected; and  it accepts that inspections of the building were carried out during construction, but submits that this does not discredit the conclusions reached by its experts that the damage to the Applicant‟s tiles was caused by faulty workmanship. Issues 11. Whether the FSP is entitled to deny the Applicant‟s claim. Case No: 305766 Determination Page 3 of 6 Reasons for decision 12. I am satisfied that there has been a full exchange of information between the parties and that each party has had an opportunity to address the issues raised therein. Non-receipt of policy 13. The Applicant says that he did not receive a copy of the policy prior to the loss and this constitutes a breach of contract. 14. The insurance policy was taken out by the body corporate and therefore the parties to the insurance contract were the body corporate and the FSP. As the owner of an individual unit, the Applicant was not a party to the contract, although he clearly benefitted under the policy. 15. As the Applicant was not a party to the contract, there was no obligation on the FSP to provide a copy of the policy to him. The obligation on an FSP is generally limited to sending a copy of the policy to the insured, which in this case was the body corporate. There is nothing to indicate that the body corpora te did not receive a copy of the policy. 16. Accordingly, I consider that the FSP has not breached its contract by not providing a copy of the policy to the Applicant prior to the loss. Policy provisions 17. It is established law that the onus falls on a policyholder to establish a prima facie claim under the policy. Once a prima facie claim has been established, the onus shifts to the insurer to establish that an exclusion applies. 18. The policy provides cover for any damage to the insured property which is not excl uded, where:  “damage” is defined to mean accidental physical loss or destruction; and  “accidental” is defined to mean something not intended or expected by the insured or a reasonable person in the insured‟s position. 19. In my view, the Applicant has established a prima facie claim under the policy. Accordingly, the onus is on the FSP to establish, on the balance of probabilities, that the claim falls within an exclusion under the policy. 20. The FSP argues that the damage falls within the policy exclusion for faulty workmanship. Cause of damage 21. The FSP relies on reports by ATS (a tiler) and MS (a building consultant) to establish that the damage to the tiles was caused by faulty workmanship. Case No: 305766 Determination Page 4 of 6 22. In his report dated 29 June 2012, ATS states that: “The cause of the tile issues at this property have been a ongoing problem that I have been involved in for the last couple of years, the lack of expansion joints and the tropical climate are the no 1 cause for this problem, but with suitable expansion this problem can be overcome. The reason for the tiles lifting in the main living area first (in all the units I have inspected) Is this is where the sun hits first causing a rapid gain in temp causing a rapid expansion of the ceramic tile. ”(sic) 23. The FSP acknowledged that ATS did not inspect the damage to the Applicant‟s unit, but relied on his inspection of tile damage to other units in the complex for the purpose of preparing his report. However, the FSP considers that ATS had sufficient knowledge to prepare his report as the tiles in all the units were installed in a similar manner. 24. I consider that the evidentiary value of ATS‟s report is significantly diminished by the fact that he did not inspect the damage which is the subject of the A pplicant‟s claim, either in person or by reviewing photographs of the damage. I consider that, for the purposes of assessing the claim, it is not reasonable for the FSP to rely on the assumption underlying ATS‟s report that the tiles in the Applicant‟s unit are identical to, and therefore subject to the same issues as have been identified in respect of, those in other apartments in the complex. 25. However, the FSP also engaged MS who conducted an inspection of the Applicant‟s unit. In his report dated 21 Septe mber 2012, MS states that: “Through the centre of the open planned living area on the southern side of the kitchen two rows of tiles have „tented‟ as a result of the stresses placed on them by the lack of control and expansion joints to the tiles. … It appears the tile have been installed tight to the masonry walls on the right hand side of the unit. … found it to measure approximately .315m indicating the tile was installed tight against the separating masonry wall between units, with no allowance for expansion or movement. … From my inspection it is my opinion the tiles have not been installed so as to comply with Australian Standards, AS:-3958.1-1991 Ceramic Tiles- Guide to the installation of ceramic tiles. This is clearly a workmanship related issue having not complied with current Australian Standards which are dated 1991, and the standard which was current when this dwelling was constructed. I also found no visible evidence of any event related issued which could have had an influence on this claim, such as water ingress. I found the tiles throughout the unit area appear to be have become drummy as a result of adhesive failure caused by the lack of control joints and or expansion joints. I found no control or expansion joint across the entire floor area, and it appears the tiles have been installed tight to the walls on all sides of the room. … Case No: 305766 Determination Page 5 of 6 The pressure / stresses which caused the tiles to „Tent‟ are caused simply by the lack of expansion and control relief measures which are required to be installed as per the standard. The floor was under stress as can be seen from the 2 rows of „Tented‟ tiles to the floor. These tented tiles are the result of stresses releasing in these areas and can be simply explained as being the weakest link in the chain and they have given way or cracked under the pressure and stress of the movement.”(sic) 26. MS ‟s opinion as to the cause of the damage was prepared following an inspection of the tiles in the Applicant‟s unit and is supported by photographic evidence and references to the applicable Australian Standard. MS‟s report clearly states that in his view the cause of the damage is the absence of control and expansion joints, which breaches the relevant Australian Standard and has resulted in pressure on the tiles causing the m to “tent” as shown in the photographs. 27. I am satisfied that MS has the necessary expertise to opine on the cause of the tile damage, and consider his report to be persuasive. 28. The Applicant has provided a copy of a report by JS (a tiler) dated 10 August 2012 which states that: “I have been doing warranty work for [J&A] Tiles for 25 years. I do not believe a silicone movement joint would have prevented this defect, I believe it is due to excessive moisture or thermal growth. Defects occur more in cold weather and ceramics grow over time. I recommend that the tile and adhesive be tested by the C.S.I.R.O. to find the cause of the defect.” 29. However, JS does not provide any explanation as to the reasons for his view that the installation of silicon movement joints would not have prevented the damage occurring and does not address the fact that the installation of the tiles does not comply with the relevant Australian Standard. Further, based on the materials provided to the Service, there does not appear to be any evidence of the “excessive moisture or thermal growth” referred to by JS and there is nothing to indicate that this was actually observed by JS. 30. Accordingly, after considering the expert evidence as a whole, I am satisfied on the balance of probabilities that the cause of the damage was due to faulty workmanship in relation to the installation of the tiles, particularly the failure to install appropriate control and expansion joints. Certificate of occupancy 31. The Applicant argues that the fact that during construction the building passed relevant inspections and a certificate of occupancy was issued indicates that there cannot have been any faulty workmanship. 32. However, I do not consider that the conduct of building inspections and the issue of a certificate of occupancy necessarily establishes that all aspects of Case No: 305766 Determination Page 6 of 6 the building work were conducted to an appropriate standard of workmanship. It is not clear that the installation of the tiles was specifically reviewed and approved by the relevant inspector, and the applicant has not provided any evidence to support this. Generally, building inspections are limited in scope and do not of themselves provide comfort that no defects or faulty workmanship exist in relation to any aspect of the building. Conclusion 33. A fter careful consideration of all of the available evidence and arguments, for the reasons set out above, I am satisfied on the balance of probabilities that the damage to the tiles in the Applicant‟s unit was caused by faulty workmanship. 34. Accordingly , the FSP is e ntitled to rely on the exclusion for faulty workmanship to deny the Applicant's claim. Determination 35. On the basis of the available information I determine that the FSP is entitled to deny the Applicant‟s claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.