Home / Financial Firm (Unknown - Insurer) / Determination 305444

Determination 305444

Denial of retaining wall damage claim (exclusion/condition)

FirmFinancial Firm (Unknown - Insurer)
Decided2013-10-09
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

Applicant's retaining wall was damaged after heavy rain and he claimed under his home policy, later attributing it to a broken stormwater pipe. The FSP denied under the rainwater run-off, soil movement and workmanship exclusions; AFCA agreed and made no award.

The insured must prove on the balance of probabilities that an insured event caused the loss, and the dominant cause here was inadequate wall construction and drainage, which the policy excludes.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 305444 Determination Page 1 of 10 Case number: 305444 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim-Exclusion/ condition 08 October 2013 Background 1. This Determination follows the review of a Recommendation issued on behalf of the Financial Ombudsman Service (FOS) on 1 August 2013. The Recommendation was rejected by the Financial Services Provider (FSP). 2. The Applicant held a home insurance policy with the FSP which was current at the time of the loss. 3. On 4 June 2012, the Applicant lodged a claim under the policy for damage to a retaining wall/foundation under his house which was starting to lean and through which water was seeping after many days of rain. 4. After investigating the Applicant’s claim, the FSP denied liability on t he basis that the damage to the retaining wall had been caused by rainwater run-off and therefore fell within an exclusion under the policy. The FSP noted that the policy also contained exclusions for loss or damage caused directly or indirectly by inherent defects, faulty design, structural defects or poor workmanship. 5. The Applicant disputes the FSP’s denial of his claim and seeks indemnity for the damage to the retaining wall. Summary of Applicant’s position 6. The Applicant says:  his claim is for water damage to the retaining wall caused by a broken storm water pipe located directly under the house;  prior to the broken pipe, the retaining wall in question had been in place for approximately 37 years without any issues; and  since the pipe was repaired by a plumber, there have been no further problems with water entering around the retaining wall. 7. The Applicant says that he has provided evidence from his builders and engineer in support of his claim, but the FSP has chosen to disregard this. 8. Accordingly, the Applicant seeks indemnity under the policy for the damage to the retaining wall. Determination Case No: 305444 Determination Page 2 of 10 Summary of FSP’s position 9. The FSP says the onus rests on the Applicant to establish that a loss has occurred as a result of an insured event. 10. The FSP relies on the report of its engineer (“MC”) which states that:  when he attended the property, there was no evidence of leaking plumbing in the area around the retaining wall;  the only possible source of the water which had caused damage to the Applicant’s retaining wall was ground water seepage or overland surface flows; and  these were deficiencies in the construction of the retaining wall which led to the soil behind it expanding due to increased moisture, resulting in damage to the retaining wall. 11. Accordingly, the FSP says that the Applicant has failed to establish that the claimed damage to the retaining wall was caused by the leaking pipe. 12. Further, the FSP says that the claimed damage falls within exclusions under the policy for:  damage to retaining walls caused by rainwater run-off;  damage caused by soil movement, subsidence etc; and/or  damage caused through inherent defects, faulty design, structural defects or poor workmanship. Issue 13. Whether the FSP is entitled to deny the Applicant’s claim. Reasons for decision 14. I am satisfied that there has been a full exchange of material between the parties and that each party has had an opportunity to address the issues raised therein. 15. This dispute concerns the cause of damage to the retaining wall under the Applicant’s house and the application of the policy in the circumstances. 16. The onus is on the Applicant to establish, on the balance of probabilities, that he has suffered a loss caused by a risk insured against under the policy. This is known as a prima facie claim. If such a claim is established, the onus shifts to the FSP to show, on the balance of probabilities, that the claim falls within an exclusion under the policy. Case No: 305444 Determination Page 3 of 10 Insured events and relevant exclusions 17. The Applicant’s policy is an insured events policy, under which cover is provided for damage caused by certain specified events. The insured events under the policy include “Storm, rainwater or run- off damage” and “Water or other liquid damage”. 18. When the Applicant lodged his claim, he advised that a retaining wall/foundation under his split level house was starting to lean and water had been seeping through after many days of rain. Accordingly, the claim was considered under the insured event of “Storm, rainwater or run - off”. 19. There is a specific exclusion under the insured event of “Storm, rainwater or run- off” for loss or damage to retaining walls. Further, there is an exclusion for any loss or damage caused by:  soil movement including erosion, landslide, mudslide or subsidence;  shrinkage or expansion of earth or land; or  hydrostatic pressure. 20. After the FSP denied his claim, the Applicant advised that, following further investigations, he believed that the damage to the retaining wall had in fact been caused by a broken stormwater drain. On this basis, it appears that the Applicant sought indemnity under the insured event of “Water or other liquid damage” which provides cover for damag e resulting directly from events including the leaking of fixed pipes. 21. Under the policy, a general exclusion applies to damage (arising under any insured event) which is “caused directly or indirectly through inherent defects, faulty design, structural defects or poor workmanship”. Evidence as to cause of damage Source of water 22. The FSP appointed a loss adjuster (“CC”) who attended the Applicant’s property on 5 June 2012 and reported that:  the Applicant had advised him that when he entered the storage area beneath the house on 1 June 2012, he noticed there was rainwater on the concrete floor of the storage area, the concrete block on the flat retaining wall was severely bowing and three of the timber stumps had shifted and collapsed;  the Applicant’s proper ty was located on a slope and would be susceptible to rainwater running down the gradient towards the house. The Applicant advised that agricultural piping had been installed at the rear of the property some years previously, to drain excess water away from the house; and Case No: 305444 Determination Page 4 of 10  it appeared that any drainage that was installed had now become blocked or defunct leading to excessive moisture in the soil under the house. However, a structural engineer should be appointed to determine the cause of the damage. 23. The structural engineer (MC) appointed by the FSP inspected the property on 6 June 2012 and reported that:  the storage area was located in an area under the front section of the house created as a result of the steep slope down towards the road. To make the area larger, part of the soil had been removed and a concrete retaining wall had been constructed to retain the earth embankment. The timber stumps that were previously in line with the retaining wall had subsequently been relocated to sit on top of the wall;  the retaining wall was designed to transfer the lateral loads from the retained soil to the foundation slab. When constructing this type of retaining wall, it was critical to ensure that adequate strength was achieved at the connection between the wall and the foundation, which is where the Applicant’s retaining wall had failed. The retaining wall did not appear to have been professionally constructed but may have been built by a handyman;  the backfill soil behind the retai ning wall appeared to be clay soil from the area and was extremely damp. Retaining walls are generally designed to carry lateral loads from the retained soil as well as some loads applied on top of the soil behind the wall (“overburden loads”), but the design does not cater for lateral loads from groundwater. Accordingly, walls of this type need to be backfilled with free draining material and agricultural drains installed behind the wall at the base to extract any water or moisture. The use of incorrect backfill material in the Applican t’s retaining wall and the lack of subsoil drainage had caused an overload due to the backfill soil becoming saturated;  there was no evidence of any leaking plumbing so the only potential source of the water in the area was ground water seepage or overland surface flows. The external brick wall at the rear of the house would prevent any overland surface flows from entering the sub-floor area and the height of the air vents in this wall made the entry of surface water unlikely. This left ground water seepage as the only other possible source of the water;  the Applicant’s yard was overgrown which would promote seepage rather than surface run-off. However, MC believed that the majority of the groundwater was coming from the larger surrounding area. This occurs when an excavation cuts into relatively pervious layers of soil, thereby creating an exit point for any ground water that naturally flows through these layers; and  the city had previously been in a long term drought during which groundwater flows were non-existent, but groundwater flows had recommenced after the return of normal to above average rainfalls. This would explain why damage had not occurred previously. The wall Case No: 305444 Determination Page 5 of 10 had withstood normal design loads and therefore was probably adequate for that purpose. 24. Based on his observations, MC concluded that:  the retaining wall failed due to the additional loads from excess ground water following the return of normal to above average rainfall conditions;  had the wall been correctly backfilled with free draining material and adequate drainage installed, the additional loads from excess water would not have been applied; and  the additional moisture was from ground water seepage as there was no evidence of plumbing leaks or surface water flows. 25. Following receipt of MC’s findings, the FSP denied the Applicant’s claim on the basis that the damage to the retaining wall was not caused directly by an insured event and fell within an exclusion for damage caused through poor workmanship or building defects. 26. In an email dated 4 August 2012 disputing the denial, the Applicant stated that:  he was positive that the damage had been caused by the unprecedented rainfall and seepage of water from the neighbouring property, which had seeped into the built up soil behind the retaining wall. At times, there was an inch or two of water above ground level draining through the back yard from the hill. The water flow occurred only during the heavy downpour;  after MC’s inspection, he has had all the water pipes, sewer and stormwater drains checked by a qualified plumber to confirm that there was no damage or leaks under the building which would cause the flow of water; and  he did not agree that the construction of the wall was defective, given that there had been no problems with the wall since he purchased the house over 37 years ago. 27. The Applicant’s claim was subsequently reviewed by the FSP’s Internal Disputes Resolution (IDR) department, which confirmed the denial by way of a letter dated 17 August 2012, on the basis that the claimed damage fell within an exclusion for damage to retaining walls caused by stormwater run- off (as well as the previously advised exclusion for poor workmanship). The FSP apologised for not referring to this exclusion in its original denial letter. 28. The Applicant s ubsequently clarified that the plumber’s inspection which he had referred to in his email of 4 August 2012 was a visual inspection only and no detailed exploratory investigations had been undertaken at this time. The Applicant says that, after his claim wa s denied, his builder (“JM”) and plumber (“DM”) undertook a more thorough investigation. In early 2013, the Applicant provided further materials to FOS in relation to these investigations. Case No: 305444 Determination Page 6 of 10 29. In a report dated 28 September 2012, the builder (JM) states that:  an inspection of the stormwater pipes with a camera on 28 August 2012 identified breakages and blockages in the stormwater pipe on the left hand side of the rear of the house , which caused water to run through the soil and penetrate through the left hand side of the retaining wall in the basement area;  tests with the garden hose found that water was coming through the corner of the retaining wall causing the floor to flood and in turn causing the retaining wall to sink into the soil and tilt over;  a machine was used to clear the blocked stormwater pipe from the footpath to the rear of the house and the damaged and blocked stormwater pipe at the left side was disconnected and replaced with a suspended water pipe under the house; and  since these repairs to the drainage system were carried out, no water has been coming through the retaining wall, despite many rainy days. 30. In a statutory declaration dated 16 January 2013, the plumber (DM) confirmed that he carried out the inspection and repairs referred to in JM’s report. 31. The FSP provided JM’s report to its engineer (MC) for comment. MC advised that:  while the stormwater blockage referred to by JM could have resulted in some water ending up in the corner of the retaining wall, it would not explain all the water along the length of the retaining wall or the damp soil along the length of the old section of the house;  if the blockages were along the left side of the house (as stated by JM), it was doubtful that the leaking water would travel across the slope to the retaining wall, due to the fall of the land and the distance to the retaining wall;  as the majority of the stormwater drainage system was across slope or down slope from the damaged area, the blocked stormwater pipes would not have contributed to the damage to the retaining wall to any significant extent;  the reduced flow of water noted by JM since repairs were carried out could be explained by recent low rainfall in the area; and  as stated in his initial report, the failure of the retaining wall was primarily due to its inability to cope with the increase in soil moisture due to lack of drainage behind the wall as a result of its inadequate design and construction. 32. The Applicant disputes MC’s statement that water was flowing from along the entire rear wall of the house in June 2012 and maintains that there has been no water at the rear of the house or in the basement since the broken stormwater pipe was repaired in August 2012. Case No: 305444 Determination Page 7 of 10 33. The Applicant subsequently provided a copy of a report dated 3 June 2013 from his engineer (“ES”) which states that:  he inspected the property on 5 September 2012; and  he considered that the damage to the retaining wall was the result of a substantial increase in the loading on the wall (ie hydrostatic pressure), which would have contributed to approximately 30% more load than the original design loading (being earth pressure only). 34. In his report, ES noted that he understood that the excess water was caused by the damaged stormwater drain which had been rectified and since then, no signs of dampness had been detected. However, the FSP has advised that ES subsequently confirmed in a conversation with the FSP’s engineer (MC) that the scope of his initial brief in September 2012 was to prepare plans to rectify the damage only, and he had only recently been asked to comment on the cause of the damage. However, ES said that he felt that there was no reason to doubt that the blocked stormwater drain had contributed to the damage. 35. Following the issue of the Recommendation, the FSP provided a further report from MC dated 14 August 2013, in which MC:  provided a plan of the house, showing the location of the leaking stormwater drain (on the left side of the house) and the location of the damaged retaining wall (parallel to the rear of the house and towards the right hand side);  confirmed that when he inspected the property, it was evident that moisture was flowing from the back wall of the house on the right hand side;  confirmed that the Applicant’s property had a slope of approximately 3 metres over the length of the block and approximately 1 metre over the length of the house and therefore any leakage from the stormwater pipe would most likely flow downhill rather than across the slope;  stated that the side retaining wall closest to the leaking stormwater drain had not suffered any damage, other than cracking damage to the corner (which, in MC’s opinion, was due to a load bearing stump being placed on the wall and the wall cracking as it tried to resist the rotation of the back retaining wall); and  included a photograph showing that the sub-floor soil was moist on the right side of the house up to the back wall, while the areas closer to the damaged stormwater drain on the left side of the house appeared drier. Construction of retaining wall 36. During the course of the dispute, the FSP’s engineer (MC) provided further information in relation to the construction of the retaining wall. In an email dated 23 May 2013, MC advised that: Case No: 305444 Determination Page 8 of 10  the retaining wall was not adequate at any stage, even before rainfall patterns returned to normal after the period of prolonged drought. However, the drought meant that there were insufficient hydrostatic loads during this period to cause the wall to collapse;  provisions of the current Building Code of Australia (introd uced around 2002) required the designer of a retaining wall to consider, and allow for, the need for drainage systems to be provided behind the retaining wall;  prior to 2002, Australian civil engineers used a British civil engineering code of practice in relation to earth retaining walls as a guide, which specified the need for a drainage system behind a retaining wall to prevent hydrostatic back-up; and  the need for drainage systems behind retaining walls was recognised as long ago as the 1880 ’ s. 37. The further report from MC dated 14 August 2013 (as referred to in paragraph 35 above) provided further commentary in relation to the construction of the retaining wall. MC noted that:  structural engineers have a responsibility to design retaining walls adequately, regardless of the existence of a building code of practice (which provides guidance only). Accordingly, in considering whether the Applicant’s retaining wall was appropriately designed, it is irrelevant whether an Australian standard was in place at the time;  further investigations of the retaining wall undertaken by MC in relation to a separate claim by the Applicant for earthquake damage, indicated that the retaining wall was not adequately reinforced with steel and therefore relied on its own weight to counteract lateral loads. A retaining wall of this nature could never be structurally adequate to withstand design loads from the soil, let alone surcharge loading from stumps and hydrostatic loads. Accordingly, the wall was structurally inadequate when first constructed;  additional loading in the way of surcharge loads had been applied to the wall within the last four years, including the stacking of items on the fill behind the wall and the installation of timber stumps on the wall and immediately behind the wall. The removal of stumps in the basement (to expand the usable area) and the introduction of a beam would also have placed extra loading on the stumps on and behind the wall as additional floor loads were transferred to the new beam; and  the recent failure of the retaining wall had occurred when the structurally inadequate wall had been subject to the additional surcharge loading referred to above, together with hydrostatic loading from water collecting behind the wall due to the lack of drainage and the increase in ground water since the breaking of the ten year drought in 2010. Case No: 305444 Determination Page 9 of 10 Analysis 38. I have carefully reviewed the various consultants’ reports referred to above, together with the numerous photographs of the damage provided by the parties. 39. The courts have determined that in order to identify whether particular damage is covered by a policy of insurance, it is necessary to establish the proximate cause of the damage. This is generally done by determining the dominant or effective cause of the damage. 40. I note that both the Applicant and the FSP have changed their position at various stages during this dispute. The Applicant initially lodged his claim on the basis that the damage to the retaining wall was caused by rainwater (and maintained that position following the FSP’s initial denial), but later said the damage arose as a result of a broken stormwater pipe. The FSP also amended its basis for denial during the claim handling process. 41. Further, it was not until after the issue of the Recommendation that either party provided a plan of the Applicant’s house, which in my view , was critical in forming a view as to the likely cause of the damage 42. The Applicant has the onus of establishing, on the balance of probabilities, that a leaking pipe caused the damage to the retaining wall. 43. The Applicant has provided evidence from his plumber (DM) and builder (JM) confirming that a leak was discovered in a stormwater pipe on the left side of the house on 28 August 2012. 44. The FSP notes that, in his email dated 4 August 2012, the Applicant stated that a plumber had inspected the water, storm and sewer pipes and confirmed that there were no leaks which would cause the water observed in the basement area. The FSP suggests that this, together with MC’s comments that he did not see any evidence of leaks when he inspected the property on 6 June 2012, suggests that the leak may have occurred after the damage to the retaining wall. 45. I accept the explanation provided by the Applicant that a detailed plumbing investigation was not undertaken until after the FSP denied his claim. The Applicant engaged tradesmen within a few days of receiving the FSP’s final denial letter, which is consistent with the explanation provided. However, it remains possible that the leak in stormwater pipe developed after the damage to the retaining wall was observed. 46. In any event, even if I accept that there was a leak in the stormwater drain, I do not accept that the Applicant has established that this caused or contributed to the claimed damage to the retaining wall, for the following reasons:  the plans provided by the FSP’s engineer (MC) (which the Applicant has not disputed) show that the leaking stormwater drain was located on the opposite side of the building from the damaged retaining wall. Case No: 305444 Determination Page 10 of 10 MC has also stated that the retaining wall nearest the leaking pipe did not sustain any damage consistent with the leak;  the slope of the Applicant’s property makes it un likely that water leaking from the damaged stormwater drain would run across the property towards the damaged retaining wall;  the photographs taken by MC at the time of his initial inspection clearly show moisture throughout the right hand side of the sub-floor area, while the left hand side is noticeably drier. This supports MC’s view that it is unlikely that the water from the leaking stormwater drain affected the damaged retaining wall;  MC who, as a structural engineer and a registered builder, is qualified to determine the cause of the damage, has put forward a detailed and logical alternative explanation as to the cause of the damage (ie that it arose as a consequence of additional loading on the retaining wall). The engineer (ES) appointed by the Applicant agreed with MC that the retaining wall had failed as a result of a substantial increase in loading. However, it appears that ES did not conduct a detailed investigation to identify the underlying cause of the damage, given that he was initially engaged to advise on fixing the damage only; and  MC’s report provides a credible explanation (consistent with the known facts) as to why the wall collapsed despite having been in place without incident for over 30 years. 47. Accordingly, based on the available evidence, I am not satisfied that the Applicant has established, on the balance of probabilities, that the leaking stormwater drain caused the claimed damage to the retaining wall. In my view, it is more likely that the damage to the retaining wall was caused by the factors identified in MC’s report. 48. Therefore, I consider that the FSP is entitled to deny the Applicant’s claim. Determination 49. On the basis of the available information I determine that the FSP is entitled to deny the Applicant’s claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.