Text of the determination
Case No: 298253 Determination Page 1 of 9
Case number: 298253
General Insurance - Domestic Insurance - Home Building - FSP Decision -
Denial of Claim - No Insured Event
26 August 2013
Background
1. The Applicants held a home building insurance policy with the Financial
Services Provider (FSP) which provided cover for their rental property. The
policy was current at the time of the loss.
2. In April 2009, the Applicants lodged a claim with the FSP for damage to
various parts of the house caused by a water leak in the bathroom. The FSP
accepted the claim and authorised repairs to internal areas of the house.
However, the FSP denied liability for cracking damage to the external
brickwork.
3. On 13 July 2012 the Applicants lodged a claim with the FSP for cracking
damage to the external walls of the house which they said occurred on or
about 1 March 2012 and was caused by heavy rain over time.
4. After investigating the Applicants’ claim, the FSP denied liability on the basis
that the damage was caused by the age of the house and the failure of the
footings and therefore fell within exclusions under the policy.
5. The Applicants dispute the FSP’s decision to decline their claim and seek
indemnity for the cracking damage to the external brickwork of the house.
6. The Applicants also seek rectification of repairs to the bathroom undertaken
by the FSP in connection with the 2009 claim.
Summary of Applicants ’ position
7. The Applicants say that the water leak in 2009 was due to a burst pipe and
caused significant damage to the interior of the house, as well as cracking
damage to the brick wall outside the bathroom.
8. The Applicants say that the cracks currently evident in the exterior brickwork
arose as a result of the leak in 2009 and should have been addressed by the
FSP at that time.
Determination
Case No: 298253 Determination Page 2 of 9
9. The Applicants h ave obtained an engineer’s report which confirms that the
cracking damage occurred as a result of the water leak. The Applicants have
also obtained a report from an aboriculturalist which disputes the
conclusions of the FSP’s engineer that a large tree loc ated near the house
contributed to the cracking damage.
10. Accordingly, the Applicants seek indemnity under the policy for the cracking
damage to the exterior brickwork of the house.
11. Additionally, the Applicants seek rectification of the repairs to the bathroom
undertaken by the FSP in 2009. The Applicant says that the bathroom tiles
are separating, the grout is falling apart and the vanity is moving away from
the wall. The Applicants say that the FSP should rectify this faulty
workmanship as their policy provides for a lifetime guarantee of all repairs.
Summary of FSP’s position
12. The FSP says that:
the report provided by its building consultant (“IT”) in connection with
the 2009 claim, indicated that the cracking damage evident at that time
was due to the depletion of foundation moisture by tree roots and was
not related to the water leak; and
a subsequent report provided by a structural engineer (“SC”) in
February 2013 confirmed that the cracking damage to the house was
not caused by the water leak in 2009 but was due to foundation
movement, most likely caused by the effect of tree roots on the reactive
foundation soil.
13. Accordingly, the FSP says that the damage was not caused by an ins ured
event, but falls within the general exclusion under the policy for settling,
shrinkage or expansion in buildings, foundations, walls or pavements.
14. The FSP says that the problems with the external walls of the house have
been evident for over four years. At no time during this period have the
Applicants taken any action to address this issue. Accordingly, the damage
also falls within the general exclusion for the insured failing to maintain the
property in good repair and condition.
15. In relation to the repairs to the bathroom carried out in 2009, the FSP says
that the issues currently being experienced are not due to faulty
workmanship but are the result of continuing movement of the house and/or
neglect by the tenant.
Issues
16. Whether the FSP is entitled to decline the Applicants’ claim for cracking
damage to the exterior walls of the house.
Case No: 298253 Determination Page 3 of 9
17. Whether the FSP is liable to rectify the bathroom repairs undertaken in 2009.
Reasons for Decision
18. As advised to the parties, FOS has considered it appropriate to expedite this
dispute in accordance with the Operational Guidelines to the FOS Terms of
Reference. Accordingly, this dispute has not been the subject of a
Recommendation but has proceeded directly to a Determination.
19. I am satisfied that a full exchange of information has taken place between
the parties and that each party has had the opportunity to address any
issues raised therein.
20. It is an established principle of insurance law that an insured bears the onus
of establishing, on the balance of probabilities, that they have suffered a loss
caused by a risk insured under the policy. Should such a prima facie claim
be established, the onus then shifts to the FSP to show, on the balance of
probabilities, that the loss falls within an exclusion under the policy or is
otherwise not covered.
21. The primary issue in dispute between the parties concerns the cause of the
cracking damage to the exterior walls of the house.
Cracking damage to exterior walls
Evidence as to cause of damage
22. When the Applicants lodged their claim in July 2012, they stated that the
cracking damage was due to heavy rainfall over a period of time. However,
in their subsequent submissions to FOS, the Applicants have identified the
cause of the damage as a burst water pipe in 2009.
23. Following lo dgement of the Applicants’ claim , the FSP appointed a builder
(“SG”) to inspect the damage to the property. SG attended the property on
16 July 2012 and reported that:
the house was in poor condition with cracks to all external brick
elevations; and
in SG’ s opinion, the damage was caused by movement and was due to
the age and footing failure of the house.
24. In considering the 2012 claim, the FSP also had regard to a report prepared
in May 2009 by its building consultant, IT, who was engaged to inspect and
advise on the extent of damage resulting from the water leak. The Applicants
had expressed concern at this time that the escaping water had caused
cracks in the external wall of the bathroom. IT reported that:
it appeared that the water leak originated from the tap spindles and/or
the feeder pipe between the shower tap T-section and the shower rose,
Case No: 298253 Determination Page 4 of 9
as water leakage only became apparent when the shower taps were
turned on;
there was significant water leakage within the brick veneer wall of the
bathroom and into the bathroom underfloor area. Escaping water was
flowing across the ground underneath the floor of the house, following
the natural gradient towards the rear yard. Elsewhere , the ground
underneath the house was dry and displayed “significant surface
f issures indicative of foundation moisture depletion”;
a survey of the external wall revealed no evidence of wall heave, as
one would reasonably expect in the event of ground saturation of the
foundation soil beneath the external wall footings. There was also no
evidence of shear failure of the foundation soil as one would expect in
the event of loss of foundation support following prolonged soil
saturation;
the crack in the bathroom wall was consistent with ground settlement in
the far east corner of the house because of the depletion of foundation
moisture by tree roots. The escaping water from the bathroom leak had
not tracked towards this corner of the house and in fact, the foundation
soil beneath the house was bone dry;
all corners of the external walls of the house were experiencing similar
cracking because of the depletion of foundation moisture by trees
growing in the property and/or neighbouring properties; and
the investigations conducted did not support a relationship between the
wall cracks and the water leak. The cracking damage was consistent
with ground settlement because of moisture depletion by tree roots.
25. Following the FSP’s decision to deny their 2012 claim, the Applicants
engaged their own engineer (“MJ”) to report on the cracking damage t o the
external brickwork in the bathroom area. MJ reported that:
the male Applicant had advised that the 2009 leak was due to a burst
water pipe in the bathroom which could have been undetected for some
time and resulted in the saturation of the underfloor area underneath
the bathroom and extending down the slope towards the south east
corner of the house. The male Applicant advised that cracks in the
external wall had developed from that time onwards;
there were moderate to severe cracks in the south east quarter of the
building which appeared to be reasonably clean and sharp, suggesting
they were relatively new;
in MJ’s opinion, given the width and extent of the cracks, the damage
was the result of substantial differential movement of the foundations.
The pattern of cracks indicated that the south east corner of the house
had subsided; and
the escape of water from the burst pipe was liable to be a significant
factor in the movement of the foundations. The cause of movement
was likely to be one or a combination of the softening of the soil due to
the escape of water in a confined area (possibly over a long period),
Case No: 298253 Determination Page 5 of 9
shrinkage and hence loss of volume whe n the soil dries out (particularly
if the sub-soils are reactive clays), and the wash out and loss of fine
material which could be transported by defective drainage.
26. Following receipt of MJ’s report, the FSP engaged a structural engineer, SC,
who reviewed the reports provided by MJ and IT and attended the property
to inspect the damage. SC’s report states that:
MJ did not appear to have accessed the underfloor foundation area to
any great extent and his report does not include any photographs of the
underfloor areas;
the information provided to MJ by the male Applicant (as reflected in
MJ’s report) appeared to be inaccurate and misleading in the following
respects:
- the 2009 water leak was caused by a breach in a non-pressure
supply pipe to the shower rose and not a burst water pipe;
- accordingly, the leak was an intermittent leak which was only
activated by use of the shower, not a continuous pressure leak; and
- the statement that the south-east corner of the foundation was
completely saturated in 2009 was inconsistent with the photographs
included in IT’s report which showed the underfloor area to be
completely dry.
MJ’s report did not refer to the potential impact of several large trees
located on or near the property;
SC observed severe cracking in the rear south east and the north east
walls of the property, and less severe cracking in the remaining walls.
Checks on vertical wall alignments showed all external walls to have a
general outward leaning tendency;
SC’s inspection of the underfloor of the house revealed a superficially
dry clay soil foundation with large drying shrinkage fissures, indicating a
moderately to highly reactive soil condition subject to substantial
surface movements related to varying moisture content. The wall and
pier footings were shallowly embedded and therefore would be subject
to foundation movements;
the foundation inside the rear wall directly under the bathroom shower
was dry and there was no evidence of moisture on the underside of the
floor framing anywhere in the bathroom. Accordingly, the intermittent
leakage identified in 2009 appeared to have been fixed at that time;
the south-east corner of the foundation was also bone dry on the
surface. This was below the external ground level and therefore would
be the ideal location for escaping water to collect (and be trapped) after
draining downhill over the surface of the foundation. Not only was there
no evidence of surface moisture in this location, there was no evidence
of water borne residue, either soil silt or vegetable detritus;
SC’s conclusion was that the movement and cracking damage affecting
the house was unrelated to the water leak in 2009. SC considered that
Case No: 298253 Determination Page 6 of 9
the underlying cause of the damage was the vulnerability of the original
construction to inherent movements in an actively moving foundation,
combined with a total lack of precautionary measures to protect the
supporting foundation from exposure to variable moisture conditions,
and a general lack of building care and maintenance ;
SC considered that the house was susceptible to movement because
of the shallow embedment of the wall and pier footings in moderate to
highly reactive foundation soil. The greatest influence on the moisture
content of the foundations was the activity of root systems from nearby
trees (including a large tree located at the front of the property), which
were clearly abundant in the foundation soil and acted to deplete the
moisture content;
the introduction of moisture into unprotected foundation areas by lack
of protection measures (such as well-maintained paths etc) and the
uncontrolled and variable extraction of moisture by tree roots led to an
unpredictable sequence of building distortions which could accumulate
over time; and
the Applicants’ contention that the walls around the south -east corner
of the house were in original, undisturbed condition prior to the leak in
2009 was unacceptable because the staggered, ground tapering cracks
were inconsistent with the loss of foundation strength because of
ground saturation or ground heave from foundation wetting. The
cracking damage was characteristic of depletion of foundation moisture
by tree roots. The fact that the cracking damage was ongoing since
2009 (as noted by the male Applicant) was due to the ongoing tree root
interference in the moisture stability and resulting volume changes of
the foundation soil.
27. The Applicants subsequently obtained a report from an arborist (“MH”) in
relation to SC’s conclusion that the large tree located at the front of the
property had contributed to the soil movement. MH’s report notes that while
it is possible that the soil movement was due to depletion of foundation
moisture by tree roots, the available evidence was not sufficient to support
this with any level of certainty because:
soil testing had not been undertaken to determine the soil class and
SC’s classification of the soil as moderately to highly reactive was
based on physical observation only;
the effect of trees usually decreases based on distance, and the south-
east corner of the house where the damage occurred was almost twice
as far from the tree as a corner of the house which showed almost no
damage; and
the exposed root in the foundations identified by SC was a thick woody
root which would not absorb water from the surrounding soil (as it has
small roots located at the ends of the woody roots which absorb water).
Case No: 298253 Determination Page 7 of 9
28. MH noted that it was outside his expertise to determine the cause of damage
to the house, and there were numerous gaps in the evidence that prevented
a comprehensive check from an arboricultural perspective.
29. The FSP provided MH’s report to SC, who reviewe d it and confirmed his
earlier findings, noting that:
all walls of the house showed an outward leaning tendency and
cracking damage, the most severe of which was in the south-east
corner and the north-east corner (ie facing the large tree);
the root system of the large tree could easily extend under and beyond
the house to affect the south-east corner;
SC had over 40 years experience in foundation matters and therefore
was sufficiently experienced to recognise the signs of shrink/swell
movement in aged clay foundations. He considered that it was not
necessary to determine the precise degree of soil reactivity to identify
the cause of the damage; and
SC’s conclusions were supported by direct observations of the soil and
a thorough on-site inspection.
30. In their submissions, the Applicants have also referred to a report by a
builder (“EC”) engaged by the FSP in 2009, who concluded that the external
wall cracking appeared consistent with water damage.
Analysis of evidence
31. I have carefully considered the expe rt evidence provided by both parties and
have also reviewed the photographs included in the reports of the various
consultants.
32. I consider that SC and MJ, as engineers, are more appropriately qualified to
assess the cause of the cracking damage to the Appl icant’s property than
the other consultants. Both SC and MJ attribute the cause of the cracking as
being due to foundation movement, although MJ attributes this to the water
leak in 2009. However, I have concerns about MJ’s report, on the basis that:
his conclusions were based on inaccurate information provided by the
male Applicant. In particular, the male Applicant’s statements regarding
the nature of the water leak and the fact that the ground under the
south-east corner of the house was fully saturated by the water leak in
2009 are inconsistent with the report prepared (and photographs taken)
by IT at that time. I consider that this information is likely to have
affected MJ’s conclusion as to the significance of the water leak; and
MJ’s report expressly states that his observations were limited to the
damage to the south-east corner of the house (where the bathroom
was located). Had MJ observed the cracking damage to other areas of
the house, this may well have impacted his conclusions as to the effect
of the 2009 leak (which did not affect the whole house).
Case No: 298253 Determination Page 8 of 9
33. I consider that SC’s report is based on a thorough investigation of the
damage to the Applicants’ property by an experienced professional and
provides a logical explanation as to the cause of this damage. SC’s
conclusions are consistent with photographs taken in 2009 which show the
soil in the underfloor area as dry and exhibiting fissures due to moisture loss.
Although MH has disputed certain of SC’s findings, he himself acknowledges
that he is not qualified to determine the cause of the damage. Further, I
consider that the observed damage (including the presence of cracking in all
corners of the house and the outward leaning of the walls) supports the
conclusion that there has been ongoing foundation movement caused by
variations in the moisture content of the foundation soil.
Application of policy
34. The Applicants’ policy contains a general exclusion for loss or damage
arising from “the settling, shrinkage or expansion in buildings, foundations,
w alls or pavements” . For the reasons outlined above, I am satisfied that the
cracking damage to the exterior walls of the Applicants’ property was caused
by ongoing foundation movement and not by the water leak in 2009.
35. Accordingly, I consider that the FSP is entitled to rely on the general
exclusion to deny the Applicants’ claim for damage to the exterior walls.
Bathroom repairs
36. The Applicants say that the repairs to the bathroom carried out in 2009 are
now failing with fissures in the grouting and tiling, and the vanity having
moved away from the wall. The Applicants seek to have these repairs
rectified pursuant to the lifetime guarantee of repairs provided under the
policy.
37. The FSP has provided a copy of an email from its assessor (“ST”) who
inspected the bathroom on 24 May 2013. In her email, ST states that:
the damage to the bathroom for which the Applicants are seeking
rectification is consistent with the continuing movement of the house;
and
there is evidence of water damage and tenant neglect, which may be
exacerbating this damage.
38. The FSP says that until the Applicants have the issues with the foundations
rectified, the bathroom will continue to experience damage.
39. While the Applicants have disputed the FSP’s findings, they have not
provided any evidence from suitably qualified persons to suggest the
damage for which they are now claiming is due to the quality of the
workmanship undertaken by the FSP’s contractors or any other event which
is covered by the policy.
Case No: 298253 Determination Page 9 of 9
40. In the absence of evidence to the contrary, I accept that the FSP is entitled
to rely on the findings of its assessor to conclude that the damage now
evident to the bathroom has not arisen as a result of a ny event which would
be covered by the policy. Further, I consider that the expert evidence
presented regarding the foundation movement issues (as outlined above)
supports the assessor’s findings in this regard.
41. The lifetime guarantee provided under the policy only applies to defects
caused by poor workmanship. As the Applicants have not established that
the current issues with the bathroom repairs were caused by poor
workmanship, I consider that, under the terms of the policy, the FSP is not
obliged to rectify the repairs.
Determination
42. On the basis of the available information I determine that:
the FSP is entitled to decline the Applicants’ claim for cracking to the
exterior walls of the house; and
the FSP is not obliged to rectify the repairs to the bathroom pursuant to
the lifetime guarantee.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.